0% found this document useful (0 votes)
30 views24 pages

RAID

RAID systems use multiple disks to provide increased storage capacity and redundancy. RAID levels differ in how data is striped or mirrored across disks and how parity is used for error checking. Higher RAID levels like RAID 5 provide improved read/write performance over RAID 4 by distributing parity across all disks.

Uploaded by

Armani Zalih
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views24 pages

RAID

RAID systems use multiple disks to provide increased storage capacity and redundancy. RAID levels differ in how data is striped or mirrored across disks and how parity is used for error checking. Higher RAID levels like RAID 5 provide improved read/write performance over RAID 4 by distributing parity across all disks.

Uploaded by

Armani Zalih
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

RAID Systems

By: Mohamed Ishraque


Mass Storage
• Many systems today need to store
many terabytes of data
• Don’t want to use single, large disk
– too expensive
– failures could be catastrophic
• Would prefer to use many smaller disks
RAID
• Redundant Array of Inexpensive Disks
• Basic idea is to connect multiple disks
together to provide
– large storage capacity
– faster access to reading data
– redundant data
• Many different levels of RAID systems
– differing levels of redundancy, error
checking, capacity, and cost
Striping
• Take file data and map it to different
disks
• Allows for reading data in parallel
file data block 0 block 1 block 2 block 3

Disk 0 Disk 1 Disk 2 Disk 3


Parity
• Way to do error checking and correction
• Add up all the bits that are 1
– if even number, set parity bit to 0
– if odd number, set parity bit to 1
• To actually implement this, do an exclusive
OR of all the bits being considered
• Consider the following 2 bytes
byte parity
10110011 1
01101010 0
• If a single bit is bad, it is possible to correct it
Mirroring
• Keep to copies of data on two separate
disks
• Gives good error recovery
– if some data is lost, get it from the other
source
• Expensive
– requires twice as many disks
• Write performance can be slow
– have to write data to two different spots
• Read performance is enhanced
– can read data from file in parallel
RAID Level-0
• Often called striping
• Break a file into blocks of data
• Stripe the blocks across disks in the
system
• Simple to implement
– disk = file block % number of disks
– sector = file block / number of disks
• provides no redundancy or error
detection
– important to consider because lots of disks
means low Mean Time To Failure (MTTF)
RAID Level-0
file data block 0 block 1 block 2 block 3 block 4

0 block 0 0 block 1
1 block 2 1 block 3
sectors 2 block 4 2
sectors
3 3
4 4
5 5

Disk 0 Disk 1
RAID Level-1
• A complete file is stored on a single disk
• A second disk contains an exact copy of the
file
• Provides complete redundancy of data
• Read performance can be improved
– file data can be read in parallel
• Write performance suffers
– must write the data out twice
• Most expensive RAID implementation
– requires twice as much storage space
RAID Level-1
file data block 0 block 1 block 2 block 3 block 4

0 block 0 0 block 0
1 block 1 1 block 1
sectors 2 block 2 2 block 2
sectors
3 block 3 3 block 3
4 block 4 4 block 4
5 5

Disk 0 Disk 1
RAID Level-2
• Stripes data across disks similar to
Level-0
– difference is data is bit interleaved instead
of block interleaved
• Uses ECC to monitor correctness of
information on disk
• Multiple disks record the ECC
information to determine which disk is
in fault
• A parity disk is then used to reconstruct
corrupted or lost data
RAID Level-2
file data block 0 block 1 block 2 block 3 block 4

Data Disk Data Disk ECC Disk ECC Disk Parity Disk
RAID Level-2
• Reconstructing data
– assume data striped across eight disks
– correct data: 10011010
– parity: 0
– data read: 10011110
– if we can determine that disk 2 is in error
– just use read data and parity to know which
bit to flip
RAID Level-2
• Requires fewer disks than Level-1 to provide
redundancy
• Still needs quite a few more disks
– for 10 data disks need 4 check disks plus parity
disk
• Big problem is performance
– must read data plus ECC code from other disks
– for a write, have to modify data, ECC, and parity
disks
• Another big problem is only one read at a
time
– while a read of a single block can be done in
parallel
RAID Level-3
• One big problem with Level-2 are the
disks needed to detect which disk had
an error
• Modern disks can already determine if
there is an error
– using ECC codes with each sector
• So just need to include a parity disk
– if a sector is bad, the disk itself tells us, and
use the parity disk to correct it
RAID Level-4
• Big problem with Level-2 and Level-3 is
the bit interleavening
– to access a single file block of data, must
access all the disks
– allows good parallelism for a single access
but doesn’t allow multiple I/O’s
• Level-4 interleaves file blocks
– allows multiple small I/O’s to be done at
once
RAID Level-4
• Still use a single disk for parity
• Now the parity is calculated over data
from multiple blocks
– Level-2,3 calculate it over a single block
• If an error detected, need to read other
blocks on other disks to reconstruct
data
Level-4 vs. Level-2,3
0 1 2 3
a

b 4 different disks
Transfer Units
c

a0 b0 c0 d0 a1 b1 c1 d1 a2 b2 c2 d2 a3 b3 c3 d3
L3
a b c d
L3 Parity

a0 a1 a2 a3 b0 b1 b2 b3 c0 c1 c2 c3 d0 d1 d2 d3
L4

0 1 2 3
L4 Parity
RAID Level-4
• Reads are simple to understand
– want to read block A, read it from disk 0
– if there is an error, read in blocks B,C, D,
and parity block and calculate correct data
• What about writes?
– it looks like a write still requires access to
4 data disks to recalculate the parity data
– not true, can use the following formula
• new parity = (old data xor new data) xor old
parity
– a write requires 2 reads and 2 writes
RAID Level-4
• Doing multiple small reads is now
faster than before
• However, writes are still very slow
– this is because of calculating and writing
the parity blocks
• Also, only one write is allowed at a time
– all writes must access the check disk so
other writes have to wait
RAID Level-5
• Level-5 stripes file data and check data
over all the disks
– no longer a single check disk
– no more write bottleneck
• Drastically improves the performance of
multiple writes
– they can now be done in parallel
• Slightly improves reads
– one more disk to use for reading
RAID Level-5
Level-4 Level-5
check
data disks disk data and check disks

1 2 3 4 5 1 2 3 4 5

S0 S0

S1 S1

S2 S2

S3 S3

S4 S4

S5 S5
RAID Level-5
• Notice that for Level-4 a write to sector 0 on
disk 2 and sector 1 on disk 3 both require a
write to disk five for check information
• In Level-5, a write to sector 0 on disk 2 and
sector 1 on disk 3 require writes to different
disks for check information (disks 5 and 4,
respectively)
• Best of all worlds
– read and write performance close to that of RAID
Level-1
– requires as much disk space as Levels-3,4
RAID Level-10
• Combine Level-0 and Level-1
• Stripe a files data across multiple disks
– gives great read/write performance
• Mirror each strip onto a second disk
– gives the best redundancy
• The most high performance system
• The most expensive system