0% found this document useful (0 votes)
35 views1 page

Pefy-P140vmhs-E Rfi

This document provides specifications for four models of ceiling concealed air conditioners: PEFY-P80VMHS-E, PEFY-P100VMHS-E, PEFY-P125VMHS-E, and PEFY-P140VMHS-E. It lists technical details such as cooling/heating capacity, power input, dimensions, material composition, air flow rates and sound levels for each model. Common features across models include use of cross fin heat exchangers with aluminum fins and copper tubes, inclusion of optional long life air filters, and connection to R410A refrigerant outdoor units.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views1 page

Pefy-P140vmhs-E Rfi

This document provides specifications for four models of ceiling concealed air conditioners: PEFY-P80VMHS-E, PEFY-P100VMHS-E, PEFY-P125VMHS-E, and PEFY-P140VMHS-E. It lists technical details such as cooling/heating capacity, power input, dimensions, material composition, air flow rates and sound levels for each model. Common features across models include use of cross fin heat exchangers with aluminum fins and copper tubes, inclusion of optional long life air filters, and connection to R410A refrigerant outdoor units.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

0000005777.

BOOK 3 ページ 2020年3月11日 水曜日 午後3時25分

1. SPECIFICATIONS Ceiling concealed (High static pressure type)

Model PEFY-P80VMHS-E PEFY-P100VMHS-E PEFY-P125VMHS-E PEFY-P140VMHS-E


1-phase 220-230-240 V 50/60 1-phase 220-230-240 V 50/60 1-phase 220-230-240 V 50/60 1-phase 220-230-240 V 50/60
Power source
Hz Hz Hz Hz
Cooling capacity *1 kW 9.0 11.2 14.0 16.0
(Nominal) *1 kcal/h 7,700 9,600 12,000 13,800
*1 BTU/h 30,700 38,200 47,800 54,600

PEFY-P-VMHS-E
*2 Power input kW 0.090 0.160 0.160 0.190
*2 Current input A 0.63 - 0.61 - 0.58 1.05 - 1.01 - 0.96 1.05 - 1.01 - 0.96 1.24 - 1.19 - 1.14
Heating capacity *3 kW 10.0 12.5 16.0 18.0
(Nominal) *3 kcal/h 8,600 10,800 13,800 15,500
*3 BTU/h 34,100 42,700 54,600 61,400
*2 Power input kW 0.090 0.160 0.160 0.190
*2 Current input A 0.63 - 0.61 - 0.58 1.05 - 1.01 - 0.96 1.05 - 1.01 - 0.96 1.24 - 1.19 - 1.14
External finish Galvanized steel plate Galvanized steel plate Galvanized steel plate Galvanized steel plate
External dimension H x W x D mm 380 x 1,030 x 900 380 x 1,195 x 900 380 x 1,195 x 900 380 x 1,195 x 900
in. 15 x 40-9/16 x 35-7/16 15 x 47-1/16 x 35-7/16 15 x 47-1/16 x 35-7/16 15 x 47-1/16 x 35-7/16
Net weight kg (lbs) 45 (100) 51 (113) 51 (113) 53 (117)
Cross fin (Aluminum fin and Cross fin (Aluminum fin and Cross fin (Aluminum fin and Cross fin (Aluminum fin and
Heat exchanger
copper tube) copper tube) copper tube) copper tube)
FAN Type x Quantity Sirocco fan x 2 Sirocco fan x 2 Sirocco fan x 2 Sirocco fan x 2
External static
*4 Pa 50 - <100> - <150> - <200> 50 - <100> - <150> - <200> 50 - <100> - <150> - <200> 50 - <100> - <150> - <200>
press.
mmH2O 5.1 - <10.2> - <15.3> - <20.4> 5.1 - <10.2> - <15.3> - <20.4> 5.1 - <10.2> - <15.3> - <20.4> 5.1 - <10.2> - <15.3> - <20.4>
Motor Type DC motor DC motor DC motor DC motor
Motor output kW 0.244 0.375 0.375 0.375
Driving mechanism Direct-driven by motor Direct-driven by motor Direct-driven by motor Direct-driven by motor
Air flow rate (Low-Mid-High) (Low-Mid-High) (Low-Mid-High) (Low-Mid-High)
m3/min 18.0 - 21.5 - 25.0 26.5 - 32.0 - 38.0 26.5 - 32.0 - 38.0 28.0 - 34.0 - 40.0
Max Air Flow Rate is 667 L/s 300 - 358 - 417 442 - 533 - 633 442 - 533 - 633 467 - 567 - 667
Total LPS in RCP is 1002 cfm 636 - 759 - 883 936 - 1,130 - 1,342 936 - 1,130 - 1,342 989 - 1,201 - 1,412
Sound pressure level (measured in anechoic room) (Low-Mid-High) (Low-Mid-High) (Low-Mid-High) (Low-Mid-High)
*2 dB <A> 25-27-30 27-31-34 27-31-34 27-32-36
Polystyrene foam, Polyeth- Polystyrene foam, Polyeth- Polystyrene foam, Polyeth- Polystyrene foam, Polyeth-
Insulation material
ylene foam, Urethane foam ylene foam, Urethane foam ylene foam, Urethane foam ylene foam, Urethane foam
Option:Synthetic fiber unwo- Option:Synthetic fiber unwo- Option:Synthetic fiber unwo- Option:Synthetic fiber unwo-
ven cloth filter (long life filter) ven cloth filter (long life filter) ven cloth filter (long life filter) ven cloth filter (long life filter)
Air filter
and filter box are recommend- and filter box are recommend- and filter box are recommend- and filter box are recommend-
ed. ed. ed. ed.
Protection device Fuse Fuse Fuse Fuse
Refrigerant control device LEV LEV LEV LEV
Connectable outdoor unit R410A CITY MULTI R410A CITY MULTI R410A CITY MULTI R410A CITY MULTI
Refrigerant piping Liquid (R410A) mm (in.) 9.52 (3/8)Brazed 9.52 (3/8)Brazed 9.52 (3/8)Brazed 9.52 (3/8)Brazed
diameter Gas (R410A) mm (in.) 15.88 (5/8)Brazed 15.88 (5/8)Brazed 15.88 (5/8)Brazed 15.88 (5/8)Brazed
Field drain pipe size mm (in.) O.D.32 (1-1/4) O.D.32 (1-1/4) O.D.32 (1-1/4) O.D.32 (1-1/4)
Drawing External KL94C742 KL94C742 KL94C742 KL94C742
Wiring KL94C743 KL94C743 KL94C743 KL94C743
Refrigerant cycle - - - -
Installation Manual, Instruction Installation Manual, Instruction Installation Manual, Instruction Installation Manual, Instruction
Standard attachment Document
Book Book Book Book
Insulation pipe for refrigerant Insulation pipe for refrigerant Insulation pipe for refrigerant Insulation pipe for refrigerant
Accessory pipe, Washer, Drain hose, Tie pipe, Washer, Drain hose, Tie pipe, Washer, Drain hose, Tie pipe, Washer, Drain hose, Tie
band band band band
Optional parts Drain pump kit PAC-DRP10DP-E2 PAC-DRP10DP-E2 PAC-DRP10DP-E2 PAC-DRP10DP-E2
Long life filter PAC-KE88LAF PAC-KE89LAF PAC-KE89LAF PAC-KE89LAF
Filter box PAC-KE99TB-F PAC-KE140TB-F PAC-KE140TB-F PAC-KE140TB-F
Remarks * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred
to the Installation Manual.
* Due to continuing improvement, above specifications may be subject to change without notice.

Notes: Unit converter


1.Nominal cooling conditions kcal =kW x 860
Indoor: 27°CD.B./19°CW.B. (81°FD.B./66°FW.B.), Outdoor: 35°CD.B. (95°FD.B.) BTU/h =kW x 3,412
Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
2.The values are measured at the factory setting of external static pressure. cfm =m3/min x 35.31
3.Nominal heating conditions lbs =kg/0.4536
Indoor: 20°CD.B. (68°FD.B.), Outdoor: 7°CD.B./6°CW.B. (45°FD.B./43°FW.B.)
Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
4.The factory setting of external static pressure is shown without < >.
Refer to "Fan characteristics curves", according to the external static pressure, in DATA BOOK for the usable
range of air flow rate.
*Above specification data is