0% found this document useful (0 votes)
82 views23 pages

OilGas en Brochure

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
82 views23 pages

OilGas en Brochure

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

Industrial Fluid Solutions

High Pressure Flexible Lines


Drilling Applications

www.continental-industry.com
High Performance
Flexible Hoses Contents
General Construction of a High Pressure Hose . . . . . . . . . . . . . . . . . . . . . 4
Continental is a global leader in the Engineering Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
design, manufacture and supply of High Pressure Hoses for Drilling & Well Service . . . . . . . . . . . . . . . . . . . . 8
flexible lines. We have over 50 years Bonded & Swaged Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
of experience in the field of bonded Drilling Hose Application Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
FSL Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
flexible pipes, and we are continuously General Information About Our Drilling Products . . . . . . . . . . . . . . . . 13
striving to extend the performance Rotary & Vibrator Hose
boundaries of our products in order with bonded coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
with swaged coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
to meet the ever more challenging
for high temperature & sour service . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
demands of our global customers. Tauro™ Cool for Arctic drilling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Continental Prospector™ Mud & Cementing Hose . . . . . . . . . . . . . . . 18
All of our high performance hose Underbalanced Drilling Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Managed Pressure Drilling Hose
products are certified to all relevant
Mud return line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
API standards for high pressure rubber Bleed off line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
hoses and flexible pipes — API 7K, API Cementing Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
16C and API 17K. Flexible Choke & Kill Lines
NEW with Tauroflon™ liner (266°F/130°C) . . . . . . . . . . . . . . . . . . . . . . . 23
with PA liner (266°F/130°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Using top quality raw materials, with PA liner (212°F/100°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
sophisticated process control and Subsea LMRP Hoses for Choke & Kill
and Hydraulic Conduit Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
the very latest R&D systems and
Mud Booster Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
processes, our expert teams are Hydraulic Conduit Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
able to draw on a comprehensive Blowout Preventer Control Hose Fireshield 5000 . . . . . . . . . . . . . . . . 29
knowledge base, ranging from Well Test Production Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Offshore Well Stimulation / Intervention / Acidizing Hose . . . . . . . . 31
material science, mathematics, and
NEW Onshore Well Stimulation Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
physics to advanced engineering and Burner/Flare Boom Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
work together with our customers Riser Tensioner Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
to offer viable solutions for the most Drill String Compensator Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Chemical Compatibility Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
demanding applications. Hose Management Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Our hose designs assure long service Continental Hose Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
life and outstanding operational and
environmental safety.
4 5
6
5
4

General construction
of a high pressure bonded hose
The flexible hose lines are a bonded construction comprising
steel and elastomeric materials. The principal characteristic
of bonded construction is the build-up of individual layers in
the flexible hose wall, which are then combined into one unit
through vulcanization. Hose assemblies are manufactured
either as a single bonded unit to specified lengths where the
couplings are an integral part of the hose, or they can be 7 8 9
mechanically assembled to the cured hose.

1 Stainless steel interlock stripwound tube


\ 4 Elastomeric cushion plies 8 Elastomeric cover
Protects the polymer lining from mechanical damage, prevents blistering in case of high pressure gas service and
To ensure adhesive bonding between different plies. Protects the flexible hose line from impact, abrasion,
decompression with vacuum service, supports the wall of the flexible hose and facilitates pigging. The material can be AISI
weather, seawater, oil, etc.
316L or 254 SMO grade stainless steel, depending on the conveyed medium.
5 High strength steel cable reinforcements
2 These are the most important load-bearing elements, as 9 Outer stainless steel stripwound protection
Polymer lining
they determine internal pressure resistance. The cables Protects the hose against external mechanical damage,
Fluid barrier of the flexible line. Protects the hose construction from corrosive and abrasive effects of the conveyed medium.
are either zinc or brass coated to provide exceptional material AISI 316L.
The thickness of lining depends on the internal pressure, the inside diameter and the conveyed medium. The lining material
corrosion resistance.
is selected to withstand chemical and heat effects of crude oil, seawater, gases, hydraulic fluid or whatever substance is
10 Stiffening spiral (not shown in the figure)
conveyed through the hose.
6 Gas leading plies To protect the hose against collapse under axial pulling
To allow diffused gases to migrate to venting points. force and/or as a result of external pressure. Prevents
3 Textile plies
kinking even in sharp bends.
To distribute the forces of internal pressure.
7 Fire resistant plies
Protects the hose in case of exposure to flame at 1300°F
(704°C) for at least 30 minutes.
6 Industrial Hose High Pressure Flexible Lines Industrial Hose High Pressure Flexible Lines 7

Tailor-made Solutions
engineering services
FINITE ELEMENT ANALYSIS EXTERNAL PROTECTION
Our in-house design software has been improved and refined Several types of external protection are available depending on the application, such as:
over many years and is used in conjunction with the most recent
finite element analysis (FEA) systems to handle even the most
difficult technical demands.

Different FEA solutions allow you to adapt the configuration of


your system to a given application and to ensure safe and reliable
operation under all conditions:

› Static, quasi-static hose length analysis


Determines the optimal hose length while allowing for any
surrounding objects that may affect the hose routing.

› Hydrodynamic analysis
Used to simulate the dynamic behavior of a given Built-in neck reinforcement
configuration when exposed to the expected environmental All hoses with bonded couplings are built with neck
conditions. reinforcement, but in strong dynamic configurations a custom
designed extra neck reinforcement might be necessary to avoid
› Survival analysis overbending of the hose. The local bending stiffness can be
Based on the hydrodynamic analysis, the suitability of the hose increased to several times of that of the hose body.
components is checked against the harshest environmental
1 Outer wrap 3 Heavy duty moonpool protection
conditions. Variable bending stiffness
Fully interlocking steel outer wrap is the most widely used A steel helix fully embedded in rubber, recommended for
Upon request, the bending stiffness of the complete hose body
external protection, able to absorb impacts and friction the harshest conditions. Exceptional impact absorption
› Fatigue analysis can be increased by a factor of 10 or more. In some cases a
and thus providing additional mechanical protection to the and abrasion resistance.
Based on the hydrodynamic analysis, the minimum design life reduction in bend stiffness is also possible.
hose body.
of a hose can be calculated by accumulating the fatigue of the
load bearing metal components. Swivels
If the hose is subject to severe twist (e.g. in the moonpool),
By their nature, bonded flexible pipes offer a high degree of swivels may be required.
design freedom: their properties can be designed and adjusted
according to the needs of your system – based on the results of Heat traced hoses
the FEA. For extreme cold conditions, or if fluid might freeze in the hose, a
self-regulating electric heating cable can be incorporated into the
hose body.

Tauro™ Fit Preformed hoses


The increasing specifications of today’s drilling rigs and floating
production facilities result in more and more equipment being
packed into the available space. Installation of a conventional
straight rubber hose in a very restricted space can impose a
considerable bending moment to keep the hose in the desired
configuration.

Such extreme bending moments can in turn transfer high end


loads to the coupling and the connected rigid piping and possibly
Bumpers
2 4 Plastic spiral
other equipment. These end loads may have a detrimental effect
If the exact location of impact between the hose and its Helps to protect the hose cover when dragging on the
on the service life of connected equipment, such as in-line swivels.
surroundings is known (e.g. in the moonpool), a plastic rig floor during handling and installation. Also suitable for
For such demanding applications, Continental has developed
bumper is advised to absorb the impact energy. static applications.
a range of pre-formed flexible hoses to make installation
easier, reduce system loads and extend service life. For more
information, see Flexible Tauro™Fit Choke & Kill Line for subsea
BOPs and Tauro™Fit Preformed Production Line.
Industrial Hose Hoses For Drilling & Well Service 9

High Pressure Hoses For Bonded & Swaged Couplings


Drilling & Well Service Applications Our bonded couplings and built-in bend stiffeners are the strongest parts of hoses produced by Continental. Our company was the first
to patent a coupling where the bonding strength between the coupling and hose body increases in proportion to the internal pressure.

The patented bonded couplings, developed in-house, the special hose construction with integral neck reinforcement and the fire-
resistant cover layer are all unique features that contribute to a high degree of chemical resistance, fatigue resistance, heat insulation
and result in a light compact hose construction with excellent flexibility and low bending radius.

Continental also supplies Rotary and Vibrator hoses with swaged couplings in accordance with API Spec. 7K (FSL1 - FSL2) on
demand delivery.

SWAGED

BONDED

TITLE NAME BONDED COUPLING SWAGED COUPLING

Only outer reinforcement layer, (and in some cases the


All reinforcement cables are adhesively
Technology innermost reinforcement layer) is directly in contact with
bonded to the coupling body
the coupling
Never full bore, there is always a flow restriction. In
Bore type Full bore, no flow restriction Choke Lines it may lead to dangerous erosion in case of
a kick
Based on pressure buildup when the coupling is
Chemical and mechanical bond between metal and
Sealing mechanism mounted, subject to stress relaxation at elevated
rubber
temperatures

Field experience 50+ years Limited, relatively new technology

Temperature limits Suitable for high fluid temperatures Limited fluid temperatures

Meets high pressure rating requirements, Limited pressure capability, max. 10,000 psi
Pressure limits
up to 20,000 psi (1,380 bar) working pressure (690 bar) working pressure

High frequency pulsations Always suitable Not suitable, unless properly designed

Coupling rigid length Shorter coupling Longer coupling

Built-in neck reinforcement, with the ability Does not have neck reinforcement, which might lead to
Neck reinforcement
to customize shortened service life

Generally longer lead time, but patented Continental


Lead time post assembling technology available in dedicated Generally shorter lead time
workshops significantly cuts lead time

Service life Generally longer service life Generally shorter service life
10 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 11

Drilling Hose
Application Guide

1 Drill string compensator hose 7 MPD hose – Bleed-off line 13 Flexible Tauro™Fit choke line
for subsea BOPs
2 Rotary hose 8 MPD hose – Mud return line

3 Cementing hose 9 Flexible choke line 14 Flexible Tauro™Fit kill line


for subsea BOPs
4 Riser tensioner hose 10 Hydraulic conduit hose

5 Flexible kill line 11 Well test hose 15 Well stimulation / Acidizing hose

6 Mud booster hose 12 Burner / Flare boom hose 16 Blowout preventer control hose

17 Vibrator hose
12 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 13

FSL Levels for High Pressure General Information


Mud & Cement Hoses and Flexible Choke & Kill Lines about products for drilling applications
The API standards 7K (mud and cement hoses) and API 16C (flexible choke and kill lines) define Flexible Specification Levels HOSE BODY FEATURES GENERAL END TERMINATION TYPES
(or FSL). For the safety of drilling operations, it is imperative for the purchaser and operator to choose the proper FSL level. › Multiple liner materials are available for different applications:
NBR, NBR/CR, Taurocool, HNBR, PA and Tauroflon™. For chemical
compatibility comparison see page 46.
FSL LEVELS FOR MUD AND CEMENT HOSES IN API 7K
› Minimum Bending Radius (MBR) is with reference to the center-line
FSL 0 — for cement hoses only Flange Type
of the hose
To meet the FSL 0 requirements, a deformation test under pressure, and ambient
and low temperature bending tests need to be performed. No pressure pulsation › Maximum recommended flow velocities: 20 m/s for dry gas
prototype test is required. 15 m/s for liquid
8 m/s for gaseous liquid
FSL 1 — for rotary, vibrator, and jumper hoses in normal service conditions
› Fire rating available at 1,300 °F (704°C) for 30 minutes on request for all Hub Type
To meet the FSL 1 requirements, in addition to FSL 0 prototype tests a low frequency
hoses with bonded couplings. This complies with both Lloyd’s Register
pressure pulsation prototype test is required - 1,000 pressure cycles (max. 5 min/
OD 1,000/499 and API 16C requirements
cycle) at maximum operating temperature.
› Additional external protection available upon request
FSL 2 — for rotary, vibrator, and jumper hoses that are likely to see high frequency
› Prod. Length Tolerance: Up to 6.4 m hose length +/– 64 mm
pressure pulsations in operation, as in directional drilling
Above 6.4 m hose length +/– 1 % Hammer Lug Union Type
To meet the FSL 2 requirements, in addition to FSL 0 prototype tests a high
frequency pressure pulsation prototype test is required - 10,000 pressure cycles
(max. 10 sec/cycle) at maximum operating temperature.

For further information on API 7K FSL levels and prototype tests, see API 7K 6th SAFETY CLAMP AND LIFTING COLLAR FITTING INSTRUCTIONS Lifting Collar
Edition Section 9.7.3.2. and 9.7.10. Each hose has a location mark on the outer cover at each end with the Safety Clamp
text “ATTACH SAFETY CLAMP HERE”. This band indicates the location
for the safety clamps.
FSL LEVELS FOR FLEXIBLE CHOKE AND KILL LINES IN API 16C
The lifting equipment supplied with the hoses includes a two-part
FSL 0 — To meet FSL 0 requirements, a hydrostatic internal pressure test, a bending lifting device at each hose end. These lifting devices are called element C’s. Element C
flexibility test, a burst test and an exposure test shall be passed. In the gas exposure The normal procedure for handling and lifting the hose involves securing
test, 3 rapid decompressions are followed by internal diameter check, and a hold the lifting collar around the element C.
period of 7 days at design pressure and maximum operating temperature. Then after Safety Chain
30 days hold at design pressure and ambient temperature, the hose performance is
validated by a 30 min pressure test at 1.5 times the design pressure.
TRANSPORTATION
FSL 1 — To meet FSL 1 requirements, in addition to FSL 0 prototype tests a fire test is
Method of packaging depending on the diameter and length of hose can be as follows:
necessary at design pressure and 1,300°F (704°C) external temperature for 30 min
› Short units: in straight position, on pallets or in wooden crates
without leakage.
› Long units: reeled onto drum, on pallets or in wooden crates
FSL 2 — To meet FSL 2 requirements, in addition to FSL 0 prototype tests a
high temperature exposure test must be performed. The test reproduces a high
temperature kick situation with the hose heated slowly to 350°F (177°C) internally
at design pressure, where it has to survive one hour without leakage. After that the
internal temperature is raised until failure of the line.

FSL 3 — To meet FSL 3 requirements, in addition to FSL 2 prototype tests a fire test is
necessary at design pressure and 1,300°F (704°C) external temperature for 30 min
without leakage.

For further information on API 16C FSL levels and prototype tests, see API 16C 2nd
Edition Section 10.8.10. and B.12.

Note: For more detailed information please request a copy of the Continental User Guide for High Pressure Flexible Lines.
14 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 15

Rotary & Vibrator Hose Rotary & Vibrator Hose


bonded coupling swaged coupling

STANDARD STANDARD
API Spec. 7K FSL 1 - FSL 2 API 7K Spec. FSL 1 - FSL 2

CONSTRUCTION CONSTRUCTION
Bore type Bore type
full flow, smooth bore not full flow, smooth bore
Liner material Liner material
NBR or NBR/CR NBR or CR
Operating temperature Operating temperature
-13°F to 212°F (-25°C to 100°C) for NBR FSL 1 -22°F to 180°F (-30°C to 82°C)
-22°F to 180°F (-30°C to 82°C) for NBR/CR FSL 2 -22°F to 212°F (-30°C to 100°C)
Max. available length Max. available length
60m (200 ft) 40m (131ft)

FEATURES & COMMENTS FEATURES & COMMENTS


› See Underbalanced Drilling Hoses for Gas, Air and Foam drilling › Generally shorter lead time
› See Managed Pressure Drilling Hoses for Managed Pressure Drilling › Swaged end fittings are protected with an all-weather
(MPD) and Dual Gradient Drilling (DGD) coating to Continental standards

TECHNICAL DATA TECHNICAL DATA

Inside Rated Working Test API Safety Outer MBR Inside Rated Working Test API Safety Outer MBR
Diameter Pressure Pressure Grade Factor Diameter (operation) Weight Diameter Pressure Pressure Grade Factor Diameter (operation) Weight
mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft. mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft.
51 2.0 276 4,000 414 6,000 C 2.5 104 4.1 0.7 2.3 15 10 76 3.0 345 5,000 517 7,500 D 2.5 126 5.0 0.8 2.6 18 12
345 5,000 517 7,500 D 2.5 104 4.1 0.7 2.3 15 10 89 3.5 345 5,000 517 7,500 D 2.5 140 5.5 0.9 3.0 21 14
64 2.5 276 4,000 414 6,000 C 2.5 111 4.4 1.7 5.6 15 10 517 7,500 776 11,250 E 2.5 138 5.4 8 2.6 28 18
345 5,000 517 7,500 D 2.5 111 4.4 0.7 2.3 15 10 101.6 4.0 345 5,000 517 7,500 D 2.5 149 5.9 1 3.3 21 14
517 7,500 776 11,250 E 2.5 136 5.4 0.8 2.6 31 21 517 7,500 776 11,250 E 2.5 150 5.96 0.9 3.0 30 21
76 3.0 276 4,000 414 6,000 C 2.5 126 5.0 0.8 2.6 18 12
345 5,000 517 7,500 D 2.5 126 5.0 0.8 2.6 18 12
517 7,500 776 11,250 E 2.5 148 5.8 1.1 3.6 34 23
89 3.5 276 4,000 414 6,000 C 2.5 140 5.5 0.9 3.0 21 14
345 5,000 517 7,500 D 2.5 140 5.5 0.9 3.0 21 14
517 7,500 776 11,250 E 2.5 162 6.4 1.3 4.3 39 26
102 4.0 276 4,000 414 6,000 C 2.5 144 5.7 0.9 3.0 21 14
345 5,000 517 7,500 D 2.5 144 5.7 0.9 3.0 21 14
517 7,500 776 11,250 E 2.5 174 6.9 1.4 4.6 42 28
127 5.0 345 5,000 517 7,500 D 2.5 213 8.4 1.5 4.9 67 45
517 7,500 776 11,250 E 2.5 213 8.4 1.5 4.9 67 45
152 6.0 345 5,000 517 7,500 D 2.25 224 8.8 1.7 5.6 57 38*
517 7,500 776 11,250 E 2.25 248 9.8 1.8 5.9 93 63*
* API 7K not labeled
16 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 17

Rotary & Vibrator Hose Tauro™Cool Rotary & Vibrator Hose


for high temperature drilling & sour service for Arctic drilling

STANDARD STANDARD
API Spec. 7K FSL 1 - FSL 2 API Spec. 7K FSL 1 - FSL 2

CONSTRUCTION CONSTRUCTION
Bore type Bore type
full flow, smooth bore full flow, smooth bore
Liner material Liner material
H2S resistant HNBR Tauro™Cool
Operating temperature Operating temperature
-22°F to 250°F (-30°C to 121°C) -40°F to 180°F (-40°C to 82°C)
Max. available length Max. available length
60m (200 ft) 60m (200 ft)

FEATURES & COMMENTS FEATURES & COMMENTS


› Designed for high working temperature and sour service mud delivery › Designed for extreme low working temperature mud delivery
› The hose is capable of handling 20% H2S (Hydrogen Sulphide) for › Additional heat tracing is available on request
1 hour at 250°F (121°C) at rated working pressure › Larger sizes are available without API label
› See Underbalanced Drilling Hoses for Gas, Air and Foam drilling › See Underbalanced Drilling Hoses for Gas, Air and Foam drilling
› See Managed Pressure Drilling Hoses for Managed Pressure Drilling › See Managed Pressure Drilling Hoses for Managed Pressure Drilling
(MPD) and Dual Gradient Drilling (DGD) (MPD) and Dual Gradient Drilling (DGD)
› Also available for 10,000 PSI (690 bar) cementing application with
Taurus design.

TECHNICAL DATA TECHNICAL DATA

Inside Rated Working Test API Safety Outer MBR Inside Rated Working Test API Safety Outer MBR
Diameter Pressure Pressure Grade Factor Diameter (operation) Weight Diameter Pressure Pressure Grade Factor Diameter (operation) Weight
mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft. mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft.

51 2.0 276 4,000 414 6,000 C 2.5 104 4.1 0.7 2.3 15 10 51 2.0 276 4,000 414 6,000 C 2.5 103 4.1 0.7 2.3 14 9
345 5,000 517 7,500 D 2.5 104 4.1 0.7 2.3 15 10 345 5,000 517 7,500 D 2.5 103 4.1 0.7 2.3 14 9
64 2.5 276 4,000 414 6,000 C 2.5 111 4.4 1.7 5.6 15 10 64 2.5 276 4,000 414 6,000 C 2.5 111 4.4 1.7 5.6 15 10
345 5,000 517 7,500 D 2.5 111 4.4 0.7 2.3 15 10 345 5,000 517 7,500 D 2.5 111 4.4 0.7 2.3 15 10
517 7,500 776 11,250 E 2.5 136 5.4 0.8 2.6 31 21 517 7,500 776 11,250 E 2.5 136 5.4 0.8 2.6 31 21
76 3.0 276 4,000 414 6,000 C 2.5 126 5.0 0.8 2.6 18 12 76 3.0 276 4,000 414 6,000 C 2.5 126 5.0 0.8 2.6 18 12
345 5,000 517 7,500 D 2.5 126 5.0 0.8 2.6 18 12 345 5,000 517 7,500 D 2.5 126 5.0 0.8 2.6 18 12
517 7,500 776 11,250 E 2.5 148 5.8 1.1 3.6 34 23 517 7,500 776 11,250 E 2.5 148 5.8 1.1 3.6 34 23
89 3.5 276 4,000 414 6,000 C 2.5 140 5.5 0.9 3.0 21 14 89 3.5 276 4,000 414 6,000 C 2.5 140 5.5 0.9 3.0 21 14
345 5,000 517 7,500 D 2.5 140 5.5 0.9 3.0 21 14 345 5,000 517 7,500 D 2.5 140 5.5 0.9 3.0 21 14
517 7,500 776 11,250 E 2.5 162 6.4 1.3 4.3 39 26 517 7,500 776 11,250 E 2.5 162 6.4 1.3 4.3 39 26
102 4.0 276 4,000 414 6,000 C 2.5 153 6.0 1.0 3.3 24 16 102 4.0 276 4,000 414 6,000 C 2.5 150 5.9 1.0 3.3 22 15
345 5,000 517 7,500 D 2.5 153 6..0 1.0 3.3 24 16 345 5,000 517 7,500 D 2.5 150 5.9 1.0 3.3 22 15
517 7,500 776 11,250 E 2.5 174 6.9 1.4 4.6 42 28 517 7,500 776 11,250 E 2.5 174 6.9 1.4 4.6 42 28
127 5.0 345 5,000 517 7,500 D 2.5 213 8.4 1.5 4.9 67 45
517 7,500 776 11,250 E 2.5 213 8.4 1.5 4.9 67 45
152 6.0 345 5,000 517 7,500 D 2.25 224 8.8 1.7 5.6 57 38*
517 7,500 776 11,250 E 2.25 248 9.8 1.8 5.9 93 63*
* API 7K not labeled
18 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 19

Continental Prospector™ Underbalanced Drillng Hose


mud & cementing hose

STANDARD STANDARD
API Spec. 7K FSL 1 and FSL 0 API Spec. 7K FSL 1

CONSTRUCTION CONSTRUCTION
Bore type Bore type
not full flow, smooth bore full flow, smooth bore
Liner material Liner material
Neoprene H2S resistant PA
Operating temperature Operating temperature
API 7K FSL1 -22°F to 180°F (-30°C to 82°C) -4°F to 180°F (-20°C to 82°C)
API 7K FSL0 -22°F to 250°F (-30°C to 121°C) Max. available length
Reinforcement 60m (200 ft)
Six alternating layers of spiraled high-tensile steel wire
Cover FEATURES & COMMENTS
Black Neoprene › Used for gas, air and foam drilling
Branding › Further constructions are available on request
Continental Prospector™ › Not suitable for operations where the hoses are likely to
Max. available length be exposed to well bore effluents. For such applications,
60m (200 ft) see Managed Pressure Drilling Hoses

FEATURES & COMMENTS


› Designed for extreme low and high working temperature mud delivery
› Additional heat tracing is available on request
› Bite-to-Wire one-piece crimp couplings provide maximum coupling TECHNICAL DATA
retention on 6-spiral hoses. Serrations penetrate the cover with a powerful
bite into the wire reinforcement, resulting in even hose compression. Inside Rated Working Test Safety Outer MBR
Diameter Pressure Pressure Factor Diameter (operation) Weight
› Couplings integrated with Hammer Lug Union Fig. 1502
mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft.
54 2.0 276 4,000 414 6,000 2.5 94 3.7 0.9 3.0 10 7
345 5,000 517 7,500 2.5 94 3.7 0.9 3.0 10 7
64 2.5 276 4,000 414 6,000 2.5 108 4.3 1.0 3.3 13 9
TECHNICAL DATA Rotary & Vibration Application / Cementing Application
345 5,000 517 7,500 2.5 110 4.3 1.0 3.3 15 10
Inside Rated Working Test Safety Outer MBR 517 7,500 776 11,250 2.5 124 4.9 1.2 3.9 22 15*
Diameter Pressure Pressure Factor Diameter (operation) Weight
76 3.0 276 4,000 414 6,000 2.5 122 4.8 1.2 3.9 15 10
mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft. 345 5,000 517 7,500 2.5 124 4.9 1.2 3.9 17 11
51 2.0 350 5,000 517 7,500 2.5 71.1 2.8 0.7 2.0 7.3 4.93 517 7,500 776 11,250 2.5 142 5.6 1.3 4.3 31 21*
51 2.0 690 10,000 1,035 15,000 2.5 71.1 2.8 0.7 2.0 7.3 4.93 89 3.5 276 4,000 414 6,000 2.5 138 5.4 1.4 4.6 20 13
345 5,000 517 7,500 2.5 138 5.4 1.4 4.6 20 13
517 7,500 776 11,250 2.5 156 6.1 1.5 4.9 35 24*
Supplied with Crimped Couplings
102 4.0 276 4,000 414 6,000 2.5 154 6.1 1.5 4.9 22 15*
2" 7K CRIMP x2" FIG 1502 MALE WITH NUT
345 5,000 517 7,500 2.5 164 6.5 1.5 4.9 32 22*
2" 7K CRIMP x2" FIG 1502 FEMALE
517 7,500 776 11,250 2.5 168 6.6 1.6 5.3 39 26*
* API 7K not labeled
20 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 21

Managed Pressure Drilling Hose Managed Pressure Drilling Hose


mud return line bleed off line

STANDARD STANDARD
API Spec. 17K API Spec. 17K

CONSTRUCTION CONSTRUCTION
Bore type Bore type
full flow, smooth bore full flow, smooth bore
Liner material Liner material
H2S resistant PA H2S resistant PA
Operating temperature Operating temperature
-4°F to 158°F (-20°C to 70°C) -4°F to 158°F (-20°C to 70°C)
Max. available length Max. available length
60m (200 ft) 60m (200 ft)

FEATURES & COMMENTS FEATURES & COMMENTS


› Used in both deepwater, shallow water and onshore MPD systems › Used in both deepwater, shallow water and onshore MPD systems
› Fit for purpose hoses and hoses for Dual Gradient Drilling (DGD systems) › Fit for purpose hoses and hoses for Dual Gradient Drilling (DGD systems)
are also available upon request are also available upon request
› Further sizes and pressure ratings are available upon request › Further sizes and pressure ratings are available upon request
› Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition › Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition

TECHNICAL DATA TECHNICAL DATA

Inside Type Rated Working Test Safety Outer MBR MBR Weight Inside Type Rated Working Test Safety Outer MBR MBR Weight
Diameter Pressure Pressure Factor Diameter (static) (dynamic) Diameter Pressure Pressure Factor Diameter (static) (dynamic)
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft. mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
102 4.0 Fire rated c/w st. st. wrap 345 5,000 518 7,500 2.5 191 7.52 1.2 3.94 1.7 5.58 45 30.2 53 2.0 Fire rated c/w st. st. wrap 345 5,000 517 7,500 2.25 141 5.53 0.8 2.62 1.0 3.28 29.4 19.7
Fire rated c/w Fire rated c/w
moonpool protection 210 8.27 1.2 3.94 1.7 5.58 63 42.3 156 6.14 0.8 2.62 1.0 3.28 38.4 25.8
moonpool protection
127 5.0 Fire rated c/w st. st. wrap 276 4,000 414 6,000 2.5 216 8.5 1.3 4.26 1.8 5.9 52 34.9
Fire rated c/w 236 9.29 1.3 4.26 1.8 5.9 72 48.4
moonpool protection
139 5.5 Fire rated c/w st. st. wrap 250 3,630 376 5,445 2.5 226 8.9 1.55 5.08 1.8 5.9 55 37
Fire rated c/w 246 9.69 1.55 5.08 1.8 5.9 76 51.1
moonpool protection
152 6.0 Fire rated c/w st. st. wrap 230 3,330 345 4,995 2.5 239 9.41 1.55 5.08 1.8 5.9 59 39.6
Fire rated c/w 259 10.2 1.55 5.08 1.8 5.9 82 55.1
moonpool protection
22 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 23

Cementing Hose Flexible Choke & Kill Line


with Tauroflon™ liner (up to 266°F/130°C)

STANDARD STANDARD STANDARD


API Spec. 7K FSL 0 API Spec. 16C up to FSL 3 API Spec. 16C up to FSL 3

CONSTRUCTION CONSTRUCTION CONSTRUCTION


Bore type Bore type Survival temperature
full flow, smooth bore Full flow, rough bore 350°F (177°C) for at least 1 hour
Liner material Liner material Max. available length
NBR H2S resistant Tauroflon™ 60m (200 ft)
Operating temperature Operating temperature
-13°F to 212°F (-25°C to 100°C) -4°F to 266°F (-20°C to 130°C)
Max. available length
60m (200 ft) FEATURES & COMMENTS
› Suitable for well completion
FEATURES & COMMENTS › Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition
› Hoses with a temperature rating of -22°F to 250°F (-30°C to 121°C) › See Flexible Tauro™Fit Choke & Kill Lines for subsea BOPs and for
and -40°F to 180°F (-40°C to 82°C) are available upon request Flexible Choke & Kill Lines with extremely small MBRs
› See Well Test Hoses for well test applications
› Saudi Aramco approved

TECHNICAL DATA
TECHNICAL DATA
Inside Inside Type Rated Working Test Safety Outer MBR MBR Weight
Diameter
Diameter Pressure Pressure Factor Diameter (storage) (dynamic)
Inside Rated Working Test Safety Outer MBR MBR Weight
Diameter Pressure Pressure Factor Diameter (storage) (operation) mm in. in.
mm bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.

mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft. 54 2.0 Fire rated 345 5,000 517 7.500 2.25 159 6.26 0.9 2.95 0.9 2.95 46 30.9
54 2.0 345 5,000 517 7.500 2.25
Fire rated c/w st. st. wrap 165 6.50 0.9 2.95 0.9 2.95 52 34.9
54 2.0 345 5,000 690 10,000 2.5 72 2.83 0.6 1.97 0.6 1.97 15 10.0
Fire rated 690 10,000 1,035 15.000 2.25 159 6.26 0.8 2.62 0.8 2.62 46 30.9
104 4.09 0.6 1.97 0.7 2.30 690 10,000 1,035 15.000 2.25
Fire rated c/w st. st. wrap 165 6.50 0.8 2.62 0.8 2.62 52 34.9
690 10,000 1,035 15,000 2.25 72 2.83 0.6 1.97 0.6 1.97 27 18.1
Fire rated 1,035 15,000 1,552 22.500 2.25 188 7.40 0.8 2.62 0.8 2.62 79 53.1
123 4.84 0.9 2.95 1.0 3.28 1,035 15,000 1,552 22.500 2.25
Fire rated c/w st. st. wrap 194 7.64 0.8 2.62 0.8 2.62 86 57.8
1,035 15,000 1,552 22,500 2.25 140 5.51 1.1 3.61 1.4 4.59 40 26.9
Standard 1,380 20,000 2,070 30.000 2.25 201 7.91 0.9 2.95 0.9 2.95 92.2 62.0
64 2.5 345 5,000 690 10,000 2.5 111 4.37 0.6 1.97 0.7 2.30 15 10.1 1,380 20,000 2,070 30.000 2.25
Standard c/w st. st. wrap 207 8.15 0.9 2.95 0.9 2.95 99.8 67.1
690 10,000 1,035 15,000 2.25 136 5.35 1.0 3.28 1.1 3.61 31 20.8
65 2.5 Fire rated 345 5,000 517 7.500 2.25 172 6.77 1.0 3.28 1.0 3.28 52 34.9
1,035 15,000 1,552 22,500 2.25 153 6.02 1.2 3.94 1.5 4.92 45 30.2 65 2.5 345 5,000 517 7.500 2.25
Fire rated c/w st. st. wrap 178 7.01 1.0 3.28 1.0 3.28 59 39.6
76 3.0 345 5,000 690 10,000 2.5 126 4.96 0.7 2.30 0.8 2.62 18 12.1
Fire rated 690 10,000 1,035 15.000 2.25 172 6.77 1.0 3.28 1.0 3.28 52 34.9
690 10,000 1,035 15,000 2.25 148 5.83 1.1 3.61 1.2 3.94 34 22.8 690 10,000 1,035 15.000 2.25
Fire rated c/w st. st. wrap 178 7.01 1.0 3.28 1.0 3.28 59 39.6
1,035 15,000 1,552 22,500 2.25 166 6.54 1.4 4.59 1.6 5.25 53 35.6
Fire rated 1,035 15,000 1,552 22.500 2.25 202 7.95 0.9 2.95 0.9 2.95 88 59.1
1,380 20,000 2,070 30,000 2.25 210 8.27 1.6 5.25 1.6 5.25 109 73.2 1,035 15,000 1,552 22.500 2.25
Fire rated c/w st. st. wrap 207 8.15 0.9 2.95 0.9 2.95 96 64.5
102 4.0 345 5,000 517 7.500 2.25 166 6.54 1.0 3.28 1.2 3.94 33 22.2
Standard 1,380 20,000 2,070 30.000 2.25 211 8.31 1.1 3.61 1.1 3.61 99.1 66.6
690 10,000 1,035 15,000 2.25 192 7.56 1.5 4.92 1.7 5.58 61 41 1,380 20,000 2,070 30.000 2.25
Standard c/w st. st. wrap 217 8.54 1.1 3.61 1.1 3.61 107 71.9
1,035 15,000 1,552 22,500 2.25 222 8.74 1.4 4.59 1.4 4.59 108 72.6
78 3.0 Fire rated 345 5,000 517 7.500 2.25 202 7.95 1.0 3.28 1.0 3.28 88 59.1
78 3.0 345 5,000 517 7.500 2.25
Fire rated c/w st. st. wrap 207 8.15 1.0 3.28 1.0 3.28 96 64.5
Fire rated 690 10,000 1,035 15.000 2.25 202 7.95 1.0 3.28 1.0 3.28 88 59.1
690 10,000 1,035 15.000 2.25
Fire rated c/w st. st. wrap 207 8.15 1.0 3.28 1.0 3.28 96 64.5
Fire rated 1,035 15,000 1,552 22.500 2.25 218 8.58 1.0 3.28 1.0 3.28 103 69.2
1,035 15,000 1,552 22.500 2.25
Fire rated c/w st. st. wrap 223 8.78 1.0 3.28 1.0 3.28 111 74.6
Standard 1,380 20,000 2,070 30.000 2.25 231 9.09 1.2 3.94 1.2 3.94 118 79.3
1,380 20,000 2,070 30.000 2.25
Standard c/w st. st. wrap 237 9.33 1.2 3.94 1.2 3.94 126.6 85.1
104 4.0 Fire rated 345 5,000 517 7.500 2.25 237 9.33 1.5 4.92 1.5 4.92 104 69.9
104 4.0 345 5,000 517 7.500 2.25
Fire rated c/w st. st. wrap 243 9.57 1.5 4.92 1.5 4.92 112 75.3
Fire rated 690 10,000 1,035 15.000 2.25 237 9.33 1.5 4.92 1.5 4.92 104 69.9
690 10,000 1,035 15.000 2.25
Fire rated c/w st. st. wrap 243 9.57 1.5 4.92 1.5 4.92 112 75.3
24 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 25

Flexible Choke & Kill Line Flexible Choke & Kill Line
with PA liner (up to 266°F/130°C) with PA liner (up to 212°F/100°C)
STANDARD CONSTRUCTION (Continued) STANDARD
API Spec. 16C up to FSL 3 Survival temperature API Spec. 16C up to FSL 3 FEATURES & COMMENTS
350°F (177°C) for at least 1 hour › Coupling materials meet NACE MR 01-75
CONSTRUCTION Max. available length CONSTRUCTION / ISO 15156 latest edition
Bore type 60m (200 ft) Bore type › See Flexible Tauro™Fit Choke & Kill Lines
Full flow, rough bore Full flow, smooth bore for subsea BOPs and for Flexible Choke &
Liner material FEATURES & COMMENTS Liner material Kill Lines with extremely small MBRs
H2S resistant PA › Coupling materials meet NACE MR 01-75 H2S resistant PA
Operating temperature / ISO 15156 latest edition Operating temperature
-4°F to 266°F (-20°C to 130°C) › See Flexible Tauro™Fit Choke & Kill Lines -4°F to 212°F (-20°C to 100°C)
for subsea BOPs and for Flexible Choke & Survival temperature
Kill Lines with extremely small MBRs 350°F (177°C) for at least 1 hour
Max. available length
TECHNICAL DATA 60m (200 ft)

Inside Type Rated Working Test Safety Outer MBR MBR Weight
Diameter Pressure Pressure Factor Diameter (storage) (operation)
TECHNICAL DATA
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft. Inside Type Rated Working Test Safety Outer MBR MBR Weight
54 2.0 Standard 345 5,000 517 7,500 2.25 142 5.6 0.8 2.6 0.8 2.6 38 26 Diameter Pressure Pressure Factor Diameter (storage) (operation)
Standard c/w st. st. wrap 152 6.0 0.8 2.6 0.8 2.6 42 28
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
Fire rated 155 6.1 0.9 3.0 0.9 3.0 44 30
Fire rated c/w st. st. wrap 167 6.6 0.9 3.0 0.9 3.0 50 34 51 2.0 Standard 345 5,000 517 7,500 2.25 113 4.5 0.8 2.6 0.8 2.6 24 16
Standard 690 10,000 1,035 15,000 2.25 142 5.6 0.8 2.6 0.8 2.6 38 26 Standard c/w st. st. wrap 123 4.8 0.8 2.6 0.8 2.6 28 19
Standard c/w st. st. wrap 152 6.0 0.8 2.6 0.8 2.6 42 28 Fire rated 128 5.0 0.9 3.0 0.9 3.0 29 20
Fire rated 155 6.1 0.8 2.6 0.8 2.6 44 30 Fire rated c/w st. st. wrap 138 5.4 0.9 3.0 0.9 3.0 33 22
Fire rated c/w st. st. wrap 167 6.6 0.8 2.6 0.8 2.6 50 34 Standard 690 10,000 1,035 15,000 2.25 113 4.5 0.8 2.6 0.8 2.6 24 16
Standard 1,035 15,000 1,552 22,500 2.25 177 7.0 1.2 3.9 1.2 3.9 69 46 Standard c/w st. st. wrap 123 4.8 0.8 2.6 0.8 2.6 28 19
Standard c/w st. st. wrap 188 7.4 1.2 3.9 1.2 3.9 76 51 Fire rated 128 5.0 0.9 3.0 0.9 3.0 29 20
Fire rated 190 7.5 1.3 4.3 1.3 4.3 76 51 Fire rated c/w st. st. wrap 138 5.4 0.9 3.0 0.9 3.0 33 22
Fire rated c/w st. st. wrap 202 8.0 1.3 4.3 1.3 4.3 84 56 Standard 1,035 15,000 1,552 22,500 2.25 136 5.4 1.0 3.3 1.1 3.6 40 27
65 2.5 Standard 345 5,000 517 7,500 2.25 155 6.1 0.9 3.0 0.9 3.0 43 29 Standard c/w st. st. wrap 146 5.8 1.0 3.3 1.1 3.6 45 30
Standard c/w st. st. wrap 167 6.6 0.9 3.0 0.9 3.0 49 33 Fire rated 150 5.9 1.1 3.6 1.2 3.9 46 31
Fire rated 169 6.7 1.0 3.3 1.0 3.3 49 33 Fire rated c/w st. st. wrap 162 6.4 1.1 3.6 1.2 3.9 53 36
Fire rated c/w st. st. wrap 180 7.1 1.0 3.3 1.0 3.3 56 38 64 2.5 Standard 345 5,000 517 7,500 2.25 127 5.0 0.9 3.0 0.9 3.0 28 19
Standard 690 10,000 1,035 15,000 2.25 155 6.1 0.9 3.0 0.9 3.0 43 29 Standard c/w st. st. wrap 137 5.4 0.9 3.0 0.9 3.0 32 22
Standard c/w st. st. wrap 167 6.6 0.9 3.0 0.9 3.0 49 33 Fire rated 141 5.6 1.0 3.3 1.0 3.3 34 23
Fire rated 169 6.7 1.0 3.3 1.0 3.3 49 33 Fire rated c/w st. st. wrap 151 5.9 1.0 3.3 1.0 3.3 38 26
Fire rated c/w st. st. wrap 180 7.1 1.0 3.3 1.0 3.3 56 38 Standard 690 10,000 1,035 15,000 2.25 127 5.0 0.9 3.0 0.9 3.0 28 19
Standard 1,035 15,000 1,552 22,500 2.25 191 7.5 1.3 4.3 1.3 4.3 77 52 Standard c/w st. st. wrap 137 5.4 0.9 3.0 0.9 3.0 32 22
Standard c/w st. st. wrap 202 8.0 1.3 4.3 1.3 4.3 85 57 Fire rated 141 5.6 1.0 3.3 1.0 3.3 34 23
Fire rated 204 8.0 1.4 4.6 1.4 4.6 85 57 Fire rated c/w st. st. wrap 151 5.9 1.0 3.3 1.0 3.3 38 26
Fire rated c/w st. st. wrap 215 8.5 1.4 4.6 1.4 4.6 94 63 Standard 1,035 15,000 1,552 22,500 2.25 149 5.9 1.1 3.6 1.3 4.3 46 31
78 3.0 Standard 345 5,000 517 7,500 2.25 168 6.6 0.9 3.0 0.9 3.0 49 33 Standard c/w st. st. wrap 159 6.3 1.1 3.6 1.3 4.3 51 34
Standard c/w st. st. wrap 180 7.1 0.9 3.0 0.9 3.0 56 38 Fire rated 164 6.5 1.2 3.9 1.4 4.6 53 36
Fire rated 182 7.2 1.0 3.3 1.0 3.3 56 38 Fire rated c/w st. st. wrap 175 6.9 1.2 3.9 1.4 4.6 60 40
Fire rated c/w st. st. wrap 193 7.6 1.0 3.3 1.0 3.3 63 42 76 3.0 Standard 345 5,000 517 7,500 2.25 141 5.6 0.9 3.0 0.9 3.0 32 22
Standard 690 10,000 1,035 15,000 2.25 168 6.6 0.9 3.0 0.9 3.0 49 33 Standard c/w st. st. wrap 151 5.9 0.9 3.0 0.9 3.0 37 25
Standard c/w st. st. wrap 180 7.1 0.9 3.0 0.9 3.0 56 38 Fire rated 155 6.1 1.0 3.3 1.0 3.3 39 26
Fire rated 182 7.2 1.0 3.3 1.0 3.3 56 38 Fire rated c/w st. st. wrap 167 6.6 1.0 3.3 1.0 3.3 45 30
Fire rated c/w st. st. wrap 193 7.6 1.0 3.3 1.0 3.3 63 42 Standard 690 10,000 1,035 15,000 2.25 141 5.6 0.9 3.0 0.9 3.0 32 22
Standard 1,035 15,000 1,552 22,500 2.25 208 8.2 1.4 4.6 1.4 4.6 90 61 Standard c/w st. st. wrap 151 5.9 0.9 3.0 0.9 3.0 37 25
Standard c/w st. st. wrap 219 8.6 1.4 4.6 1.4 4.6 98 66 Fire rated 155 6.1 1.0 3.3 1.0 3.3 39 26
Fire rated 218 8.6 1.5 4.9 1.5 4.9 97 65 Fire rated c/w st. st. wrap 167 6.6 1.0 3.3 1.0 3.3 45 30
Fire rated c/w st. st. wrap 230 9.1 1.5 4.9 1.5 4.9 106 71 Standard 1,035 15,000 1,552 22,500 2.25 164 6.5 1.2 3.9 1.4 4.6 52 35
104 4.0 Standard 345 5,000 517 7,500 2.25 219 8.6 1.4 4.6 1.4 4.6 89 60 Standard c/w st. st. wrap 175 6.9 1.2 3.9 1.4 4.6 59 40
Standard c/w st. st. wrap 230 9.1 1.4 4.6 1.4 4.6 98 66 Fire rated 178 7.0 1.4 4.6 1.7 5.6 59 40
Fire rated 232 9.1 1.5 4.9 1.5 4.9 98 66 Fire rated c/w st. st. wrap 190 7.5 1.4 4.6 1.7 5.6 67 45
Fire rated c/w st. st. wrap 243 9.6 1.5 4.9 1.5 4.9 108 73 102 4.0 Standard 345 5,000 517 7,500 2.25 184 7.2 1.4 4.6 1.4 4.6 54 36
Standard 690 10,000 1,035 15,000 2.25 219 8.6 1.4 4.6 1.4 4.6 89 60 Standard c/w st. st. wrap 190 7.5 1.4 4.6 1.4 4.6 61 41
Standard c/w st. st. wrap 230 9.1 1.4 4.6 1.4 4.6 98 66 Fire rated 198 7.8 1.5 4.9 1.5 4.9 66 44
Fire rated 232 9.1 1.5 4.9 1.5 4.9 98 66 Fire rated c/w st. st. wrap 204 8.0 1.5 4.9 1.5 4.9 70 47
Fire rated c/w st. st. wrap 243 9.6 1.5 4.9 1.5 4.9 108 73 Standard 690 10,000 1,035 15,000 2.25 184 7.2 1.4 4.6 1.4 4.6 54 36
104 4.0 Standard 1,035 15,000 1,552 22,500 2.25 244 9.6 1.6 5.2 1.6 5.2 126 85 Standard c/w st. st. wrap 190 7.5 1.4 4.6 1.4 4.6 61 41
Standard c/w st. st. wrap 250 9.8 1.6 5.2 1.6 5.2 135 91 Fire rated 198 7.8 1.5 4.9 1.5 4.9 66 44
Fire rated 254 10.0 1.7 5.6 1.7 5.6 135 91 Fire rated c/w st. st. wrap 204 8.0 1.5 4.9 1.5 4.9 70 47
Fire rated c/w st. st. wrap 260 10.2 1.7 5.6 1.7 5.6 144 97
26 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 27

Subsea LMRP Hoses Subsea LMRP Hoses


for Choke & Kill and Hydraulic for Choke & Kill and Hydraulic
Conduit Application Conduit Application, Cont.
STANDARD HYDRAULIC CONDUIT (PA, LINING)
API Spec. 16C up to FSL 3
Inside Type Rated Working Test Safety Outer MBR MBR Weight
Diameter Pressure Pressure Factor Diameter (storage) (operation)
CONSTRUCTION
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
Bore type
full flow, rough bore 54 2.0 Standard 345 5,000 517 7,500 2.25 142 5.6 0.8 2.6 0.8 2.6 38 26
Liner material Standard c/w st. st. wrap 152 6.0 0.8 2.6 0.8 2.6 42 28
H2S resistant PA or Tauroflon™ Standard 690 10,000 1,035 15,000 2.25 142 5.6 0.8 2.6 0.8 2.6 38 26
Shape Standard c/w st. st. wrap 152 6.0 0.8 2.6 0.8 2.6 42 28
Pre-formed hose available if necessary Standard 1,035 15,000 1,552 22,500 2.25 177 7.0 1.2 3.9 1.2 3.9 69 46
Operating temperature Standard c/w st. st. wrap 188 7.4 1.2 3.9 1.2 3.9 76 51
-4°F to 250°F (-20°C to 121°C) 65 2.5 Standard 345 5,000 517 7,500 2.25 155 6.1 0.9 3.0 0.9 3.0 43 29
Max. available length
Standard c/w st. st. wrap 167 6.6 0.9 3.0 0.9 3.0 49 33
60m (200 ft)
Standard 690 10,000 1,035 15,000 2.25 155 6.1 0.9 3.0 0.9 3.0 43 29

FEATURES & COMMENTS Standard c/w st. st. wrap 167 6.6 0.9 3.0 0.9 3.0 49 33
› Easy installation in confined spaces Standard 1,035 15,000 1,552 22,500 2.25 191 7.5 1.3 4.3 1.3 4.3 77 52
Used on Lower Marine Riser Package (LMRP) at subsea BOPs Standard c/w st. st. wrap 202 8.0 1.3 4.3 1.3 4.3 85 57
› Extended service life as a result of reduced risk of over-bending and › Opens up new design opportunities to reduce 78 3.0 Standard 345 5,000 517 7,500 2.25 168 6.6 0.9 3.0 0.9 3.0 49 33
reduced stress on hose body and on coupling the size and weight of oil field equipment Standard c/w st. st. wrap 180 7.1 0.9 3.0 0.9 3.0 56 38
› Transfers less load to adjacent equipment or pipework › Coupling materials meet NACE MR 01-75 / ISO Standard 690 10,000 1,035 15,000 2.25 168 6.6 0.9 3.0 0.9 3.0 49 33
› New short coupling design increases flexible length with no reduction 15156 latest edition Standard c/w st. st. wrap 180 7.1 0.9 3.0 0.9 3.0 56 38
in bonding strength › Hose length analysis is available upon request Standard 1,035 15,000 1,552 22,500 2.25 208 8.2 1.4 4.6 1.4 4.6 90 61
Standard c/w st. st. wrap 219 8.6 1.4 4.6 1.4 4.6 98 66
TECHNICAL DATA
CHOKE & KILL HOSES (TAUROFLON™ LINING)

Inside Type Rated Working Test Safety Outer MBR MBR Weight
Diameter Pressure Pressure Factor Diameter (storage) (operation)
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
51 2.0 Standard 690 10,000 1,035 15,000 2.25 146 5.75 0.8 2.62 0.8 2.62 40 26.9
Standard c/w st. st. wrap 151 5.94 0.8 2.62 0.8 2.62 46 30.9
Standard 1,035 15,000 1,552 22,500 2.25 175 6.89 0.8 2.62 0.8 2.62 72 48.4
Standard c/w st. st. wrap 181 7.13 0.8 2.62 0.8 2.62 78 52.4
Standard 1,380 20,000 2,070 30,000 2.25 201 7.91 0.9 2.95 0.9 2.95 92.2 62
Standard c/w st. st. wrap 207 8.15 0.9 2.95  0.9 2.95 99.8 67.1
65 2.5 Standard 690 10,000 1,035 15,000 2.25 159 6.26 0.9 2.95 0.9 2.95 46 30.9
Standard c/w st. st. wrap 165 6.50 0.9 2.95 0.9 2.95 52 34.9
Standard 1,035 15,000 1,552 22,500 2.25 195 7.68 0.9 2.95 0.9 2.95 81 54.5
Standard c/w st. st. wrap 201 7.91 0.9 2.95 0.9 2.95 88 59.3
Standard 1,380 20,000 2,070 30,000 211 8.31 1.1 3.61 1.1 3.61 99.1 66.6
Standard c/w st. st. wrap 217 8.54 1.1 3.61 1.1 3.61 107 71.9
78 3.0 Standard 690 10,000 1,035 15,000 2.25 188 7.40 0.9 2.95 0.9 2.95 80 53.8
Standard c/w st. st. wrap 194 7.64 0.9 2.95 0.9 2.95 87 58.5
Standard 1,035 15,000 1,552 22,500 2.25 204 8.03 1.0 3.28 1.0 3.28 95 63.8
Standard c/w st. st. wrap 210 8.27 1.0 3.28 1.0 3.28 102 68.5
Standard 1,380 20,000 2,070 30,000 2.25 231 9.09 1.2 3.94 1.2 3.94 118 79.3
Standard c/w st. st. wrap 237 9.33 1.2 3.94 1.2 3.94 126.6 85.1
28 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 29

Mud Booster Hose Hydraulic Conduit Hose

STANDARD STANDARD
API Spec. 7K FSL1 - FSL 2 & API SPec. 16C - up to FSL 3 API Spec. 7K FSL1 - FSL 2 & API Spec. 16C - up to FSL 3

CONSTRUCTION CONSTRUCTION
API 16C - UP TO FSL 3 API 7K FSL 1 - FSL 2 API 7K FSL 1 - FSL 2 API 16C - UP TO FSL 3
Bore type Bore type
full flow, rough bore full flow, smooth bore full flow, smooth bore full flow, smooth bore
Liner material Liner material
H2S resistant Tauroflon™ & PA NBR NBR H2S resistant PA
Operating temperature Operating temperature
-4°F to 250°F (-20°C to 121°C) -13°F to 212°F (-25°C to 100°C) -13°F to 212°F (-25°C to 100°C) -4°F to 212°F (-20°C to 100°C)
Max. available length Max. available length
60m (200 ft) 60m (200 ft) 60m (200 ft) 60m (200 ft)

FEATURES & COMMENTS FEATURES & COMMENTS


› The construction with Tauroflon™ liner is suitable for well completion › Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition
› Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition

TECHNICAL DATA
TECHNICAL DATA
AS PER API SPEC. 7K
AS PER API SPEC. 16C WITH TAUROFLON™ LINING
Inside Working Test API Safety Outer MBR MBR Weight
Inside Type Rated Working Test Safety Outer MBR MBR Weight Diameter Pressure Pressure Grade Factor Diameter (storage) (operation)
Diameter Pressure Pressure Factor Diameter (storage) (operation) mm in. bar psi bar psi WP WP mm in. m ft. m ft. kg/m lb./ft.
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft. 51 2.0 345 5,000 517 7,500 D 2.5 104 4.09 0.6 1.97 0.7 2.30 15 10.1
104 4.0 Standard 345 5,000 517 7,500 2.25 124 4.88 1.4 4.6 1.4 4.6 94 63 64 2.5 345 5,000 517 7,500 D 2.5 111 4.37 0.6 1.97 0.7 2.30 15 10.1
Standard c/w st. st. wrap 130 5.12 1.4 4.6 1.4 4.6 103 69 76 3.0 345 5,000 517 7,500 D 2.5 126 4.96 0.7 2.30 0.8 2.62 18 12.1
Fire rated 237 9.33 1.5 4.9 1.5 4.9 104 70 89 3.5 345 5,000 517 7,500 D 2.5 140 5.51 0.8 2.62 0.9 2.95 21 14.1
Fire rated c/w st. st. wrap 243 9.57 1.5 4.9 1.5 4.9 112 75

AS PER API SPEC. 16C


AS PER API SPEC. 16C WITH PA LINING
Inside Type Rated Working Test Safety Outer MBR MBR Weight
Inside Type Rated Working Test Safety Outer MBR MBR Weight Diameter Pressure Pressure Factor Diameter (storage) (operation)
Diameter Pressure Pressure Factor Diameter (storage) (operation) mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft. 51 2.0 Standard 345 5,000 517 7,500 2.25 113 4.45 0.8 2.6 0.8 2.6 24 16
104 4.0 Standard 345 5,000 517 7,500 2.25 219 8.6 1.4 4.6 1.4 4.6 89 60 Standard c/w st. st. wrap 123 4.84 0.8 2.6 0.8 2.6 28 19
Standard c/w st. st. wrap 230 9.1 1.4 4.6 1.4 4.6 98 66 Fire rated 128 5.04 0.9 3.0 0.9 3.0 29 20
Fire rated 232 9.1 1.5 4.9 1.5 4.9 98 66 Fire rated c/w st. st. wrap 138 5.43 0.9 3.0 0.9 3.0 33 22
Fire rated c/w st. st. wrap 243 9.6 1.5 4.9 1.5 4.9 108 72 64 2.5 Standard 345 5,000 517 7,500 2.25 127 5.00 0.9 3.0 0.9 3.0 28 19
Standard c/w st. st. wrap 137 5.39 0.9 3.0 0.9 3.0 32 22
Fire rated 141 5.55 1.0 3.3 1.0 3.3 34 23
AS PER API SPEC. 7K
Fire rated c/w st. st. wrap 151 5.94 1.0 3.3 1.0 3.3 38 26
Inside Type Working Test API Safety Outer MBR Weight 76 3.0 Standard 345 5,000 517 7,500 2.25 141 5.55 0.9 3.0 0.9 3.0 32 22
Diameter Pressure Pressure Grade Factor Diameter (operation)
Standard c/w st. st. wrap 151 5.94 0.9 3.0 0.9 3.0 37 25
mm in. bar psi bar psi WP WP mm in. m ft. kg/m lb./ft. Fire rated 155 6.10 1.0 3.3 1.0 3.3 39 26
102 4.0 Standard 345 5,000 517 7,500 D 2.5 159 6.3 1.0 4.0 29 20 Fire rated c/w st. st. wrap 167 6.57 1.0 3.3 1.0 3.3 45 30
Standard 517 7,500 446 11,250 E 2.5 174 6.9 1.4 4.6 42 28
127 5.0 Standard 345 5,000 517 7,500 D 2.5 213 8.4 1.5 4.9 67 45
Standard 517 7,500 776 11,250 E 2.5 213 8.4 1.5 4.9 67 45
30 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 31

Blowout Preventer Control Hose Well Test Production Hose


Fireshield 5000
STANDARD
CONSTRUCTION API Spec. 17K & API Spec. 16C - up to FSL 3
Bore type
not full flow, smooth bore CONSTRUCTION
Liner material API 16C - UP TO FSL 3 API 17K
NBR Bore type
Reinforcement full flow, rough bore full flow, rough bore full flow, rough bore
2 wire braid (up to 3/8”) Liner material
4 or 6 wire spirals (above 3/8”) H2S resistant Tauroflon™ H2S resistant PA H2S resistant PA
Cover Operating temperature
Red flame retardant CR rubber over layers of heat resistant fiber -4°F to 266°F -4°F to 212°F -4°F to 194°F
Operating temperature (-20°C to 130°C) (-20°C to 100°C) (-20°C to 90°C)
-4°F to 212°F (-20°C to 100°C) Max. available length
Max. available length 60m (200 ft) 60m (200 ft) 60m (200 ft)
60m (200 ft)
FEATURES & COMMENTS
FEATURES & COMMENTS › Suitable for both Drill Stem test (DST) and Production Test (PT)
› Used in onshore and offshore drilling operations on the Blow Out › Designed to withstand continuous periods of operation with a high risk of rapid decompression
Preventer (BOP) to provide hydraulic power to seal the well head in case › There is no recognized industry standard for Well Test Production Hoses. However, in view of
of a kick or an emergency situation where operation is critical during the typical operating conditions, the API specifications for Flexible Choke & Kill Lines (API 16C)
exposure to fire and high temperature or Bonded Flexible Pipes (API 17K) used for production should be considered. Flexible Choke &
› Fire rating meets and exceeds Lloyd’s Register OD/1000/499 at 1292°F Kill Lines are designed to withstand short-term high pressure and high temperature operation,
for 5 minutes in accordance to the guidelines of API 16D while production hoses must withstand continuous periods of operation with a high risk of
› The QR74 Quick Release valved couplings also fully comply to Lloyd’s decompression
Register OD/1000/499 fire rating › Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition
› Stainless steel armor is available upon request to protect the hose
against external mechanical damage
TECHNICAL DATA
AS PER API SPEC. 16C WITH TAUROFLON™ LINING

Inside Type Rated Working Test Safety Outer MBR Weight


TECHNICAL DATA Diameter Pressure Pressure Factor Diameter (operation)
mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft.
Minimum Minimum
Inside Diameter Working Pressure Burst Pressure Outer Diameter Bend Radius Weight 78 3.0 Fire rated c/w st. st. wrap 690 10,000 1,035 15,000 2.25 207 8.2 1.0 3.3 96 65
mm in. bar psi bar psi mm in. mm in. kg/m lb./ft. Fire rated c/w st. st. wrap 1,035 15,000 1,552 22,500 2.25 223 8.8 1.5 4.9 111 75

6.5  1/4 345 5,000 1,380 20,000 20.0 0.8 110 4.3 0.75 0.50 104 4.0 Fire rated c/w st. st. wrap 690 10,000 1,035 15,000 2.25 243 9.6 1.5 4.9 112 75

9.5  3/8 345 5,000 1,380 20,000 24.0 0.9 150 5.9 0.80 0.54
12.7  1/2 345 5,000 1,380 20,000 30.0 1.2 250 9.8 1.22 0.82 AS PER API SPEC. 16C WITH PA LINING
19.1  3/4 345 5,000 1,380 20,000 37.0 1.5 330 13.0 1.82 1.22
25.1 1  345 5,000 1,380 20,000 44.0 1.7 375 14.8 2.53 1.70 Inside Type Rated Working Test Safety Outer MBR Weight
Diameter Pressure Pressure Factor Diameter (operation)
31.7 1 1/4 345 5,000 1,380 20,000 58.0 2.3 460 18.1 4.20 2.82
38.1 1 1/2 345 5,000 1,380 20,000 63.0 2.5 520 20.5 6.29 4.23 mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft.

50.8 2  345 5,000 1,380 20,000 77.0 3.0 700 27.6 8.90 5.98 78 3.0 Fire rated c/w st. st. wrap 690 10,000 1,035 15,000 2.25 193 7.6 1.0 3.3 63 42
Fire rated c/w st. st. wrap 1,035 15,000 1,552 22,500 2.25 230 9.1 1.5 4.9 106 71
104 4.0 Fire rated c/w st. st. wrap 690 10,000 1,035 15,000 2.25 243 9.6 1.5 4.9 108 73

AS PER API SPEC. 17K WITH PA LINING

Inside Type Rated Working Test Safety Outer MBR Weight


Diameter Pressure Pressure Factor Diameter (static)
mm in. bar psi bar psi WP mm in. m ft. kg/m lb./ft.
78 3.0 Fire rated c/w st. st. wrap 517 7500 690 11250 2.25 201 7.9 1.5 4.9 67 45
104 4.0 Fire rated c/w st. st. wrap 251 9.9 1.8 5.9 112 75
32 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 33

Offshore Well Stimulation / Onshore Well Stimulation Hose


Intervention / Acidizing Hose
STANDARD
API Spec. 16C - up to FSL 3 CONSTRUCTION
Bore type
CONSTRUCTION full flow, smooth bore
Bore type Liner material
full flow, rough bore Erosion resistant elastomer
Liner material Operating temperature
H2S resistant Tauroflon™ -22°F to 158°F (-30°C to 70°C)
Operating temperature Max. available length
-4°F to 266°F (-20°C to 130°C) 60m (200 ft)
Max. available length
60m (200 ft) FEATURES & COMMENTS
› High pressure hoses used to transport slickwater to enhance
FEATURES & COMMENTS onshore shale well performance.
› Designed to withstand a large range of acidizing liquids and fracturing solutions › Designed to withstand high velocity slickwater for a long period of time
› Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition › Great chemical resistance against HCl
› Liner suitable for well test/flowback applications › Fewer connections than traditional iron and piping, reducing the risk of leaks and assembly time
› Reduced maintenance and longer service life compared to traditional iron and piping
› Extends service life of adjacent piping, valves and elbows due to reduced turbulence
› Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition
TECHNICAL DATA

Inside Type Rated Working Test Safety Outer MBR MBR Weight
Diameter Pressure Pressure Factor Diameter (storage) (operation)
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
54 2.0 Standard 690 10,000 1,035 15,000 2.25 146 5.75 0.8 2.62 0.8 2.62 40 26.9
Standard c/w st. st. wrap 151 5.94 0.8 2.62 0.8 2.62 46 30.9
TECHNICAL DATA
Fire rated 159 6.26 0.9 2.95 0.9 2.95 46 30.9 Inside Type Rated Working Test Safety Outer MBR MBR Weight
Fire rated c/w st. st. wrap 165 6.50 0.9 2.95 0.9 2.95 52 34.9 Diameter Pressure Pressure Factor Diameter (storage) (operation)
Standard 1,035 15,000 1,552 22,500 2.25 175 6.89 1.2 3.94 1.2 3.94 72 48.4 mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
Standard c/w st. st. wrap 181 7.13 1.2 3.94 1.2 3.94 78 52.4 Standard c/w
51 2.0 1,035 15,000 1,552 22,500 2.00 152 5.98 0.7 2.30 0.7 2.30 38 25.7
Fire rated 188 7.40 1.3 4.26 1.3 4.26 79 53.1 moonpool protection
Standard c/w
Fire rated c/w st. st. wrap 194 7.64 1.3 4.26 1.3 4.26 86 57.8 69 2.7 156 6.14 0.7 2.30 0.7 2.30 41 27.6
moonpool protection
Standard 1,380 20,000 2,070 30,000 2.25 201 7.91 0.9 2.95 0.9 2.95 92 62.0
Standard c/w st. st. wrap 207 8.15 0.9 2.95 0.9 2.95 100 67.1
Fire rated 214 8.43 0.9 2.95 0.9 2.95 101 67.5 Inside Type Rated Working Test Safety Outer MBR MBR Weight
Fire rated c/w st. st. wrap 220 8.66 0.9 2.95 0.9 2.95 109 72.9 Diameter Pressure Pressure Factor Diameter (static) (dynamic)
78 3.0 Standard 690 10,000 1,035 15,000 2.25 188 7.40 0.9 2.95 0.9 2.95 80 53.8 mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
Standard c/w st. st. wrap 194 7.64 0.9 2.95 0.9 2.95 87 58.5 102 4.0 Standard c/w plastic spiral 1,035 15,000 1,552 22,500 2.00 223 8.78 1.4 4.59 1.5 4.92 87 58.5
Fire rated 202 7.95 1.0 3.28 1.0 3.28 88 59.1 127 5.0 Standard c/w plastic spiral 262 10.31 1.8 5.90 1.8 5.90 123 82.5
Fire rated c/w st. st. wrap 207 8.15 1.0 3.28 1.0 3.28 96 64.5 150 6.0 Standard c/w plastic spiral 302 11.89 1.8 5.90 1.8 5.90 160 107.3
Standard 1,035 15,000 1,552 22,500 2.25 204 8.03 1.4 4.59 1.4 4.59 95 63.8
Standard c/w st. st. wrap 210 8.27 1.4 4.59 1.4 4.59 102 68.5
Fire rated 218 8.58 1.5 4.92 1.5 4.92 103 69.2
Fire rated c/w st. st. wrap 223 8.78 1.5 4.92 1.5 4.92 111 74.6
Standard 1,380 20,000 2,070 30,000 2.25 231 9.09 1.2 3.94 1.2 3.94 118 79.3
Standard c/w st. st. wrap 237 9.33 1.2 3.94 1.2 3.94 127 85.1
Fire rated 244 9.61 1.2 3.94 1.2 3.94 129 86.3
Fire rated c/w st. st. wrap 250 9.84 1.2 3.94 1.2 3.94 138 92.5
104 4.0 Standard 690 10,000 1,035 15,000 2.25 124 4.88 1.4 4.59 1.4 4.59 94 63.2
Standard c/w st. st. wrap 130 5.12 1.4 4.59 1.4 4.59 103 69.2
Fire rated 237 9.33 1.5 4.92 1.5 4.92 104 69.9
Fire rated c/w st. st. wrap 243 9.57 1.5 4.92 1.5 4.92 112 75.3
34 Industrial Hose Hoses For Drilling & Well Service Industrial Hose Hoses For Drilling & Well Service 35

Burner/Flare Boom Hose Riser Tensioner Hose

STANDARD STANDARD
API Spec. 17K API Spec. 17K

CONSTRUCTION CONSTRUCTION
Bore type Bore type
full flow, rough bore full flow, smooth, rough bore
Liner material Liner material
H2S resistant HNBR H2S resistant HNBR
Operating temperature Operating temperature
-22°F to 194°F (-30°C to 90°C) -22°F to 158°F (-30°C to 70°C)
Max. available length Max. available length
60m (200 ft) 60m (200 ft)

FEATURES & COMMENTS FEATURES & COMMENTS


› Designed to connect the production test manifold to the burner / flare boom › Used for transporting hydraulic fluid between gas filled accumulators
› Coupling materials meet NACE MR 01-75 / ISO 15156 latest edition and large hydraulic cylinders. Although they are not in direct contact with
› Material of the end fittings is either carbon steel or duplex pressurized gas, the hydraulic fluid will invariably contain dissolved gas
› Material of the internal carcass is either 316L or 254 SMO after some time, even in configurations with pistons between the gas and
the liquid phase. There is a clear risk that this dissolved gas can cause
collapse of the hose liner and ultimate failure following decompression.
Since API 7K does not include gas exposure testing, it should not be
considered for riser tensioner hose applications.
› Oil and glycol resistant liner
TECHNICAL DATA
Inside Type Rated Working Test Safety Outer MBR MBR Weight
Diameter Pressure Pressure Factor Diameter (static) (dynamic)
mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft. TECHNICAL DATA
76 3.0 Fire rated 207 3,000 310 4,500 2.25 179 7.05 1.1 3.6 1.5 4.9 46 31
Fire rated c/w st. st. wrap 185 7.28 1.1 3.6 1.5 4.9 53 36 Inside Bore Type Rated Working Test Safety Outer MBR MBR Weight
Fire rated 345 5,000 517 7,500 2.25 197 7.76 1.2 3.9 1.7 5.6 65 44 Diameter Pressure Pressure Factor Diameter (storage) (dynamic)

Fire rated c/w st. st. wrap 208 8.19 1.2 3.9 1.7 5.6 73 49 mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft.
102 4.0 Fire rated 207 3,000 310 4,500 2.25 205 8.07 1.4 4.6 1.8 5.9 57 38 150 6.0 Smooth Fire rated 207 3,000 310 4,500 2.5 237 9.33 1.55 5.08 1.8 5.90 53 35.6
Fire rated c/w st. st. wrap 211 8.31 1.4 4.6 1.8 5.9 64 43 207 8.0 Rough Fire rated 345 5,000 517 7,500 2.25 331 13.0 2.4 7.9 3.2 10.5 139 93
Fire rated 345 5,000 517 7,500 2.25 223 8.78 1.5 4.9 2.0 6.6 79 53
Fire rated c/w st. st. wrap 234 9.21 1.5 4.9 2.0 6.6 88 59
130 5.0 Fire rated 207 3,000 310 4,500 2.25 249 9.80 1.5 4.9 2.0 6.6 92 62
Fire rated c/w st. st. wrap 261 10.28 1.5 4.9 2.0 6.6 102 69
Fire rated 345 5,000 517 7,500 2.25 252 9.92 1.6 5.3 2.1 6.9 97 65
Fire rated c/w st. st. wrap 263 10.35 1.6 5.3 2.1 6.9 107 72
152 6.0 Fire rated 207 3,000 310 4,500 2.25 259 10.20 1.6 5.3 2.1 6.9 79 53
Fire rated c/w st. st. wrap 270 10.63 1.6 5.3 2.1 6.9 89 60
Fire rated 345 5,000 517 7,500 2.25 279 10.98 1.9 6.2 2.6 8.5 112 75
Fire rated c/w st. st. wrap 291 11.46 1.9 6.2 2.6 8.5 124 83
36 Industrial Hose Hoses For Drilling & Well Service 37

Chemical Compatibility Table

Drill String Compensator Hose MEDIUM PRODUCT LINING

Tauro™Cool NBR HNBR PA Tauroflon™

Crude oil 82°C 180°F 100°C 212°F 100°C 212°F 100°C 212°F 130°C 266°F
STANDARD Diesel oil 82°C 180°F 100°C 212°F 121°C 250°F 130°C 266°F 130°C 266°F
API Spec. 17K
Water based mud 82°C 180°F 90°C 200°F 90°C 200°F 50°C 122°F 130°C 266°F
CONSTRUCTION 90°C 200°F
Bore type
Oil based mud 82°C 180°F 100°C 212°F 121°C 250°F 130°C 266°F 130°C 266°F
full flow, rough bore
Liner material Ester based mud 82°C 180°F 90°C 200°F 130°C 266°F
H2S resistant HNBR
Operating temperature Xylene 66°C 150°F 66°C 150°F 130°C 266°F
100oC 212oF
-22°F to 194°F (30°C to 90°C)
Max. available length Methanol NR NR 25°C 75°F 25°C 75°F 50°C 122°F 130°C 266°F
60m (200 ft) 40°C 100°F 90oC 200oF

FEATURES & COMMENTS Glycol 70°C 160°F 70°C 160°F 70°C 160°F 70°C 160oF 100°C 212°F
› Used for hydro-pneumatic medium transport to the drill string compensator Hydrogen sulphide 60°C 140°F 130oC 266oF 130°C 266°F
cylinder to isolate the heaving motion of the rig from the drill string (<20%) 90°C 200°F

Zinc bromide 30°C 90°F 30°C 90°F 30°C 90°F 25°C 75°F 130°C 266°F
(40%) 82°C 180°F 90°C 200°F 50°C 122°F 50°C 122°F

Zinc bromide 30°C 90°F 30°C 90°F 30°C 90°F 25°C 125°F 130°C 266°F
(saturated) 50°C 122°F 50°C 122°F

Calcium bromide 30°C 90°F 30°C 90°F 90°C 200°F 50°C 122°F 130°C 266°F
TECHNICAL DATA (25%) 50°C 122°F 50°C 122°F 90°C 200°F

Inside Type Rated Working Test Safety Outer MBR MBR Weight Calcium bromide 30°C 90°F 30°C 90°F 90°C 200°F 50°C 122°F 130°C 266°F
Diameter Pressure Pressure Factor Diameter (static) (dynamic) (saturated) 50°C 122°F 50°C 122°F 90°C 200°F

mm in. bar psi bar psi WP mm in. m ft. m ft. kg/m lb./ft. Cesium formate 82°C 180°F 100°C 212°F 100°C 212°F 50°C 122°F 130°C 266°F
53 2.0 Standard 207 3,000 310 4,500 2.25 130 5.1 0.8 2.6 1.1 3.6 46 31 (saturated) 121°C 250°F 100°C 212°F
Standard 345 5,000 517 7,500 2.25 148 5.8 0.9 3.0 1.2 3.9 39 26
Potassium formate 82°C 180°F 100°C 212°F 100°C 212°F 50°C 122°F 130°C 266°F
65 2.5 Standard 207 3,000 310 4,500 2.25 142 5.6 0.9 3.0 1.2 3.9 29 20 (75%) 121°C 250°F 100°C 212°F
Standard 345 5,000 517 7,500  2.25 159 6.3 0.9 3.0 1.2 3.9 44 30
Acetic acid 82°C 180°F 90°C 200°F 90°C 200°F 50°C 122°F 130°C 266°F
78 3.0 Standard 207 3,000 310 4,500 2.25 158 6.2 1.0 3.3 1.4 4.6 39 26
(20%) 90°C 200°F
Standard 345 5,000 517 7,500  2.25 176 6.9 1.1 3.6 1.5 4.9 54 36
92 3.5 Standard 207 3,000 310 4,500 2.25 173 6.8 1.1 3.6 1.5 4.9 41 28 Acetic acid 50°C 122°F 50°C 122°F 50°C 122°F 25°C 75°F 130°C 266°F
(96%) 90°C 200°F 90°C 200°F 50°C 122°F
Standard 345 5,000 517 7,500  2.25 190 7.5 1.2 3.9 1.7 5.6 60 40
103 4.0 Standard 207 3,000 310 4,500 2.25 184 7.2 1.2 3.9 1.7 5.6 45 30 Formic acid 50°C 122°F 30°C 90°F 50°C 122°F 25°C 75°F 130°C 266°F
Standard 345 5,000 517 7,500  2.25 202 8.0 1.4 4.6 1.8 5.9 67 45 82°C 180°F 50°C 122°F 90°C 200°F 50°C 122°F

127 5.0 Standard 207 3,000 310 4,500 2.25 211 8.3 1.4 4.6 1.8 5.9 54 36 Hydrochloric acid 60°C 140°F 60°C 140°F 30°C 90°F 25°C 75°F 130°C 266°F
Standard 345 5,000 517 7,500  2.25 231 9.1 1.5 4.9 2.0 6.6 83 56 (15%) 82°C 180°F 90°C 200°F 60°C 140°F 50°C 122°F
152 6.0 Standard 207 3,000 310 4,500 2.25 236 9.3 1.6 5.3 2.1 6.9 63 42
Hydrochloric acid 30°C 90°F 30°C 90°F 30°C 90°F NR NR 130°C 266°F
Standard 345 5,000 517 7,500 2.25 257 10.1 1.8 5.9 2.4 7.9 96 65 (37%)

Hydrofluoric acid 30°C 90°F NR NR 30°C 90°F 25°C 75°F 130°C 266°F
(3%) 60°C 140°F

Hydrofluoric acid NR NR NR NR 30°C 90°F 25°C 75°F 130°C 266°F


(10%) 60°C 140°F

Sodium hydroxide 50°C 122°F 66°C 150°F


(20%)

Produced water 82°C 180°F 100°C 212°F 121°C 250°F 50°C 122°F 130°C 250°F
90°C 200°F

Key: max. operating temperature for unlimited application max. operating temperature for limited application NR - not recommended
38 Industrial Hose Hoses For Drilling & Well Service 39

Quality

As part of the Continental group, we are committed to quality and respect for the environment. We work closely with customers
and approved suppliers to ensure the highest quality standards. The quality management system is in accordance with ISO 9001
and API Spec. Q1. The system’s performance is regularly checked and audited by independent auditors.

Currently the Company’s Quality Management System is approved and certified by Dekra and API.

Our products fully comply with the latest edition of API Spec. 7K, API Spec. 16C and API Spec. 17K standards.

Continental was the first and for many years the only high pressure bonded hose manufacturer certified for all three relevant
standards. Hose sizes range from 2“ to 16“ with pressure ratings up to 20,000 psi.

The environmental thinking of the management and the employees is reflected by their daily activities and documented by the ISO
14001 environmental management system applied in the company.

Hose Management Services


Tailored, expert solutions for the maintenance
of your flexible hose assemblies.
Ensuring the safe and reliable operation of your flexible hose Test and inspection can be carried out in dedicated facilities in a
assemblies, whether in offshore or onshore installations, is number of strategic locations worldwide, or we can come to your
essential. Effective hose management not only ensures your preferred location. In addition, we inspect and maintain reeling
operation will continue to run smoothly, but will also eliminate systems, such as bunker stations or off-loading systems.
any potential safety or environmental issues and reduce
downtime to keep your productivity levels high. INVENTORY MANAGEMENT
An instant overview of all flexible hose assemblies on all of your
Continental is a world leader in the manufacture of high-pressure installations worldwide: ContiConnect is a web-based inventory
drilling and bonded production hoses, crude oil transfer hoses management program designed for your peace of mind. Being
as well as utility and hydraulic assemblies designed specifically able to see the current status of your FHAs at the click of a
for the oil and gas industry. Our expertise and knowledge in this button means you can schedule maintenance, order timely
field is unrivaled. With this in-depth capability we have helped to replacements and ensure trouble-free operations.
develop the industry standards and guidelines for best practice
in the field of integrity management for flexible hose assemblies. INSTALLATION AND COMMISSIONING
With our in-depth expertise in all aspects of fluid transfer in the
International oil and gas producers and operators across the oil and gas industry, we are your first-choice partner for advising
globe rely on Continental throughout the lifecycle of their flexible and assisting in the specification, installation, commissioning and
hose assemblies, from design and specification through supply change-out of flexible hose assemblies and systems, including
to full management of their fluid transfer systems in operation. high-pressure drilling, production, utility, GMPHOM 2009, turret
and FPSO seawater intake hoses and also reeling stations.
We can help you with a number of services, all designed to offer
you peace of mind as standard. These are: HOSE FAILURE ANALYSIS
We carry out various investigations on damaged high-pressure
INSPECTION, TESTING & REPAIR hoses or hose parts at our facility, to reveal the possible causes
A complete range of inspection and testing services – including: of damage and propose necessary actions to avoid similar
› inspection and repair of external protection, rubber cover and failures in the future.
end fitting painting
› high pressure hydrostatic testing,
› borescope inspection of the internal carcass or liner
› recertification
Continental
Global Leaders in Hose Solutions

Canada Hungary
Granby UK Szeged
Grimsby
Blyth

Germany
Hamburg Sea-Water Intake Systems Dredge Hose Systems Hose Management
USA Hoppegarten
Fairlawn Korbach
Houston Northeim
Mount Pleasant Oedelsheim China
Norfolk Qingdao
Sun Prairie Shanghai
Yanzhou
UAE
Dubai

Brazil
Macaé South Africa
Chile Australia
Santana de Parnaiba, Brazil Uitenhage
Santiago de Chile Bayswater Industrial Hoses Deep Sea Mining Intelligent Hoses

The global partner of choice for industrial fluid product systems and services.
For combined solutions – smart and sustainable.

Our products are created to the very specific needs of our customer’s applications in
nearly all industries. This results in hoses and hose systems for the construction industry,
the food and drinks industry, for chemical and petrochemical production operations, oil &
gas exploration, water treatment, mining, steel production and mechanical engineering.

Continental is made up of a host of sites across the globe and together boast an excellent
track record in providing customized solutions in the most diverse environmental
Marine Hoses Dock Hoses
conditions in the world.
Industrial Fluid Solutions
Market segment
Industrial Hose

Contact
Continental
www.continental-industry.com

ContiTech Fluid Oil & Marine


Middle East FZE
PO Box 261406 - Jebel Ali Free Zone
Dubai
Tel: +971 (4) 561 5990
Fax: +971 (4) 427 8809
Email: [email protected]

ContiTech Oil & Marine Corp


11535 Brittmore Park Drive
Houston, TX 77041 U.S.A.
Tel: +1 832 327 0141
Fax: +1 832 327 0148
Email: [email protected]

ContiTech Rubber Industrial Kft.


6728 Szeged, Budapesti ut 10
Tel: +36 62 566 738
Fax: +36 62 566 999
Email: [email protected]

Dunlop Oil & Marine Ltd


Blyth Workspace, Quay Road, Blyth
Northumberland, NE24 3AF, England
Tel: +44 1670 528700
Fax: +44 1670 520535
Email: [email protected]

Your local contact


www.contitech.de/contactlocator

Learn more about


the contents of this
brochure.
ES-CO-CTL-O&G 03/2021

The content of this publication is not legally binding and is provided


as information only. The trademarks displayed in this publication are
the property of Continental AG and/or its affiliates. Copyright © 2021
ContiTech AG. All rights reserved. For complete information go to:
www.contitech.de/discl_en

You might also like