C2000D6
C2000D6
Diesel
generator set
QSK60 series
engine
1760kVA - 2500kVA 50 Hz
1825kW - 2250kW 60 Hz
Description
Control system – The PowerCommand®
This Cummins® Power Generation commercial
generator set is a fully integrated power electronic control is standard equipment and
generation system, providing optimum provides total genset system integration
performance, reliability, and versatility for including automatic remote starting/stopping,
stationary standby, prime power, and precise frequency and voltage regulation, alarm
continuous duty applications. and status message display, AmpSentry™
protection, output metering, auto-shutdown at
Features fault detection and NFPA 110 Level 1
compliance.
Cummins® heavy-duty engine - Rugged 4-
cycle industrial diesel delivers reliable power, Cooling system - Standard integral set-
low emissions and fast response to load mounted radiator system, designed and tested
changes. for rated ambient temperatures, simplifies facility
Permanent magnet generator (PMG) - Offers design requirements for rejected heat.
enhanced motor starting and fault clearing NFPA - The genset accepts full rated load in a
short circuit capability. single step in accordance with NFPA 110 for
Alternator - Several alternator sizes offer Level 1 systems.
selectable motor starting capability with low Warranty and service - Backed by a
reactance 2/3 pitch windings; low waveform comprehensive warranty and worldwide
distortion with non-linear loads, fault clearing distributor network.
short-circuits capability, and class F or H
insulation.
Emissions
Standby rating Prime rating compliance Data sheets
50 Hz 60 Hz 50 Hz 60 Hz TA Luft – EU
Model kVA (kW) kW (kVA) kVA (kW) kW (kVA) Stage 50 Hz 60 Hz
C1760 D5e 1760 (1408) 1600 (1280) 2g TA Luft DS49-CPGK
power.cummins.com
©2016 Cummins Power Generation Inc. | SS17e-CPGK (3/16)
Generator set specifications
Transient Performance ISO 8528-5 compliant
Voltage regulation, no load to full load ± 0.5%
Random voltage variation ± 0.5%
Frequency regulation Isochronous
Random frequency variation ± 0.25%
EMC compatibility BS EN 61000-6-4 / BS EN 61000-6-2
Engine specifications
Design 4 cycle, V-black, turbo charged and low temperature after-cooled
Bore 158.8 mm (6.25 in)
Stroke 190.0 mm (7.48 in)
Displacement 60.2 L (3673 in3)
Cylinder block Cast iron, 60ºV 16 cylinder
Battery capacity 2200 amps at ambient temperature 0ºF to 32ºF (-18 °C to 0°C)
Battery charging alternator 40 amps
Starting voltage 24- volt, negative ground
Fuel system Direct injection
Fuel filter Triple element, spin on fuel filters with water separator
Air cleaner type Dry replaceable element
Lube oil filter type(s) Four spin-on, combination full flow and bypass filters
Standard cooling system 104ºF (40ºC) ambient radiator
Alternator specifications
Design Brushless, 4 pole, drip proof revolving field
Stator 2/3 pitch
Rotor Direct coupled by flexible disc
Insulation system Class H
Standard temperature rise 150 °C standby
Exciter type PMG (Permanent magnet generator)
Phase rotation A (U), B (V), C (W)
Alternator cooling Direct drive centrifugal blower fan
AC waveform total harmonic distortion No load <1.5%. Non distorting balanced linear load <5%
Telephone influence factor (TIF) < 50% per NEMA MG1-22.43
Telephone harmonic factor (THF) < 3%
Available voltages
50 Hz line – neutral / line - line 60 Hz line – neutral / line - line
220/380 1905/3300 219/380 2400/4160
230/400 3640/6300 254/440 7200/12470
240/415 3810/6600 277/480 7620/13200
254/440 6350/11000 347/600 7970/13800
Note: Consult factory for other voltages.
*Note: Some options may not be available on all models - consult factory for availability.
power.cummins.com
©2016 Cummins Power Generation Inc. | SS17e-CPGK (3/16)
PowerCommand® 3.3 control system
Engine data
DC voltage
Engine speed
Lube oil pressure and temperature
Coolant temperature
Comprehensive FAE data (where applicable)
Other data
Genset model data
Start attempts, starts, running hours, kW hours
Control system Load profile (operating hours at % load in 5%
increments)
The PowerCommand® control system is an Fault history
integrated microprocessor based generator set Data logging and fault simulation (requires
control system providing voltage regulation, engine InPower)
protection, alternator protection, operator interface
and isochronous governing.
AmpSentry – Includes integral AmpSentry protection,
Standard control functions
which provides a full range of alternator protection
Digital governing (optional)
functions that are matched to the alternator
provided. Integrated digital electronic isochronous governor
Power management – Control function provides Temperature dynamic governing
battery monitoring and testing features and smart Digital voltage regulation
starting control system. Integrated digital electronic voltage regulator
Advanced control methodology – Three phase 3-phase, 4-wire line-to-line sensing
sensing, full wave rectified voltage regulation, with a Configurable torque matching
PWM output for stable operation with all load types.
Communications interface – Control comes standard AmpSentry AC protection
with PCCNet and Modbus interface. AmpSentry protective relay
Regulation compliant – Prototype tested: UL, CSA Over current and short circuit shutdown
and CE compliant. Over current warning
Service - InPower™ PC-based service tool available Single and three phase fault regulation
for detailed diagnostics, setup, data logging and fault Over and under voltage shutdown
simulation. Over and under frequency shutdown
Reliable design – The control system is designed for Overload warning with alarm contact
reliable operation in harsh environment. Reverse power and reverse var shutdown
Multi-language support Field overload
Engine protection
Operator panel features Battery voltage monitoring, protection and testing
Over speed shutdown
Operator panel features – The operator panel, in Low oil pressure warning and shutdown
addition to the alternator, displays the Utility/AC Bus High coolant temperature warning and shutdown
data. Low coolant level warning or shutdown
Operator/display functions Low coolant temperature warning
Fail to start (over crank) shutdown
320 x 240 pixels graphic LED backlight LCD Fail to crank shutdown
Auto, manual, start, stop, fault reset and lamp Cranking lockout
test/panel lamp switches Sensor failure indication
Alpha-numeric display with pushbuttons Low fuel level warning or shutdown
LED lamps indicating genset running, remote start, Fuel-in-rupture-basin warning or shutdown
not in auto, common shutdown, common warning, Full authority electronic engine protection
manual run mode, auto mode and stop
Control functions
Paralleling control functions
Time delay start and cool down
Digital frequency synchronization and voltage Real time clock for fault and event time stamping
matching Exerciser clock and time of day start/stop
Isochronous kW and kvar load sharing controls Data logging
Droop kW and kvar control Cycle cranking
Sync check Load shed
Extended paralleling (Peak Shave/Base Load) Configurable inputs and outputs (4)
Digital power transfer control (AMF) provides load Remote emergency stop
transfer operation in open or closed transition or
soft (ramping) transfer mode Options
Alternator data Auxiliary output relays (2)
Line-to-neutral and line-to-line AC volts
3-phase AC current
Frequency
kW, kvar, power factor kVA (three phase and total)
power.cummins.com
©2016 Cummins Power Generation Inc. | SS17e-CPGK (3/16)
Emergency standby power (ESP):
Applicable for supplying power to varying electrical load
for the duration of power interruption of a reliable utility
source. Emergency Standby Power (ESP) is in
accordance with ISO 8528. Fuel Stop power in
accordance with ISO 3046, AS 2789, DIN 6271 and BS
5514.
Limited-time running power (LTP):
This outline drawing is to provide representative configuration
Applicable for supplying power to a constant electrical details for Model series only.
load for limited hours. Limited Time Running Power
(LTP) is in accordance with ISO 8528. See respective model data sheet for specific model outline
drawing number.
Prime power (PRP):
Applicable for supplying power to varying electrical load Do not use for installation design
for unlimited hours. Prime Power (PRP) is in
accordance with ISO 8528. Ten percent overload
capability is available in accordance with ISO 3046, AS
2789, DIN 6271 and BS 5514.
Base load (continuous) power (COP):
Applicable for supplying power continuously to a
constant electrical load for unlimited hours. Continuous
Power (COP) in accordance with ISO 8528, ISO 3046,
AS 2789, DIN 6271 and BS 5514.
Dim “A” Dim “B” Dim “C” Set Weight* Set Weight*
Model mm mm mm dry kg wet kg
C1760 D5e 6175 2494 3422 14825 16040
This generator set is available with CE This generator set has been designed to
ISO 8528
certification. comply with ISO 8528 regulation.
Manston Park Columbus Ave. 1400 73rd Avenue N.E. 10 Toh Guan Road #07-01
Kent CT12 5BF United Kingdom Phone 763 574 5000 Singapore 608838
Phone 44 1843 255000 Fax 763 574 5298 Phone 65 6417 2388