1. FEATURES
* Data record mode : Normal model or Peak hold mode.
* Normal record mode :
Set sampling time from 1 second to 8 hours.
* Peak hold record mode :
Set sampling time from 10 ms to 500 ms.
* Memory capacity of normal record mode : 1 GB to 16 GB.
* Memory capacity of peak hold record mode :
1000 data no. ( max. )
* Under Peak hold record mode, if execute the " Data
record " function, the memory circuit will store 1000
data no. ( max. ) measuring data into the SD card per
fast speed sampling time ( 10 ms to 500 ms ).
* Under Normal record mode, if execute the " Data record
" function, will save the measuring data along the real
time value ( Year/Month/ Date/Hour/Minute/Second )
into the SD card per normal sampling time ( 1 second
to 8 hours ).
* After save the data into the SD memory card, it can be
down load the data to the Excel directly, extra software
is no need. User can make the further data analysis (
graphic analysis ) by themselves.
* Large LCD display with back light.
* 5,000 g, wide capacity, high resolution, high accuracy,
high repeatability.
* 3 kind display unit : g, oz, Newton.
* Tension & compression capability .
* Peak hold ( Max. load ) can be held in display during
make tension or compression measurement.
* Zero button can operate both for normal measuring
& the " peak hold " operation.
* Full capacity zero (tare) control capability.
* Fast/Slow response time push button.
1
* Positive or reverse display direction select.
* Full line accessories ( adapters ) are included.
* Hand held & stand mounted gauges are available.
* Low power consumption gives long battery life.
* Build in low battery indicator.
* Microprocessor circuit & exclusive load cell
transducer.
* Over load protection.
* RS-232 computer interface
* Built-in DC 9V power adapter input socket.
* Professional test stand ( optional ).
2. SPECIFICATIONS
Display LCD ( Liquid crystal display ).
5 digits, 16 mm ( 0.63" ) digit size.
Back light.
Display Positive or Reverse direction, select by
Direction the push button on the front panel.
Function Tension & Compression (Push & Pull).
Normal force, Peak hold ( Max. load ).
Peak hold Will freeze the display value of the
Peak load ( Max. load ).
Zero Zero button can be operated both for
"normal force" or "peak hold" operation
Unit select g/oz/Newton
Measure 5,000 g/176.40 oz/49.03 Newton.
Capacity
Resolution 1 g/0.02 oz/0.01 Newton.
Min. Display 3 g/0.10 oz/0.03 Newton.
Accuracy ± ( 0.4 % + 1 digit ), within 23± 5℃.
* Under the test weight on 3000 g & 5000 g.
2
Update time Fast Approx. 0.2 second.
Slow Approx. 0.6 second.
Over range Display show " - - - - " when in over
Indicator range status.
Normal data Auto 1 sec to 8 hour 59 min. 59 sec.
record mode data @ Sampling time can set to 1 second,
logger but memory data may loss.
Sampling Time Manual Push the data logger button
Setting range data once will save data one time.
logger @ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Peak hold 10 mS to 500 mS.
data record * Each setting step is 10 mS.
mode * Auto data logger
Sampling Time * The memory circuit will store 1000
Setting range data no. ( max. ) measuring data.
Data error no. 0.1% of total saved data max.
Memory Card SD memory card. 1 GB to 16 GB.
Advanced * SD memory card Format
setting * Set clock time ( Year/Month/Date,
Hour/Minute/Second )
* Set sampling time ( normal data record mode )
* Set sampling time ( peak hold data record mode)
* Auto power OFF management
* Unit setting
* Set beep Sound ON/OFF
* Decimal point of SD card setting
Data output RS 232/USB PC computer interface.
* Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
* Connect the optional USB cable
USB-01 will get the USB plug.
3
Overload Max. 7 kg.
Capacity
Full Scale Approx. 0.2 mm max.
Deflection
Zero/tare Max. full capacity.
Control
Transducer Exclusive load cell.
Circuit Exclusive microprocessor LSI-circuit.
Power Supply * AAlkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
* ADC 9V adapter input. ( AC/DC power
adapter is optional ).
Power Current Normal operation ( w/o SD card save
data and LCD Backlight is OFF) :
Approx. DC 7 mA.
When SD card save the data and LCD
Backlight is OFF) :
Approx. DC 38 mA.
* AIf LCD backlight on, the power
consumption will increase approx.
3 mA.
Operating 0℃ to 50℃ ( 32℉ to 122℉ ).
Temperature
Operating Less than 80% RH.
Humidity
Dimension 215 x 90 x 45 mm ( 8.5 x 3.5 x 1.8 inch ).
Weight 650 g ( 1.43 LB )/with batteries.
Mounting Main instrument with mounting holes are
Holes provided on the back case, easy stand
mounting.
4
Accessories Operating manual .....................1 PC.
Included Flat-head adapter......................1 PC.
Hook adapter ...........................1 PC.
Cone head adapter ...................1 PC.
Chisel head adapter ..................1 PC.
120 mm extension rod...............1 PC.
Carrying case ...........................1 PC.
Optional * TSD memory card ( 2 GB )
Accessories * Test stand, Model : FS-1001
* Wedge grip, Model : WG-01
* RS232 cable, Model : UPCB-02.
* USB cable, Model : USB-01
* Software for data logging & data
recorder.
* EXCEL data acquisition software
Model : SW-E802
5
3. FRONT PANEL DESCRIPTIONS
Fig. 1
6
3-1 Universal Sensing Head
3-2 LCD Display
3-3 Power/BACKLIGHT Button
3-4 ▲/ZERO Button
3-5 Fast/SLOW/ESC Button
3-6 PEAK/ENTER Button
3-7 DISPLAY REVERSE/▼ Button
3-8 TIME/SET Button
3-9 LOGGER/SAMPLING CHECK Button
3-10 RS-232 output terminal
3-11 Reset terminal
3-12 DC 9V Power Adapter Input Socket
3-13 Mounting Holes/fixing Screws
3-14 Battery Cover/Compartment
3-15 Flat-head Adapter
3-16 Cone Adapter
3-17 Chisel Adapter
3-18 Hook Adapter
3-19 120 mm Extension Rod.
3-20 SD card socket
7
4. MEASURING PROCEDURE
4-1 Pay attention for the measurement
1) Compression measurement, the display will show the
" - " mark automatically.
Fig. 2
8
3) Rotate the SENSING HEAD is prohibited. Some certain
angles between SENSING HEAD & measuring object
are not allowed ( ref. Fig. 3 ).
Fig. 3
Power on :
Press " Power Button " ( 3-3, Fig. 1) once.
Power off :
During power on, press " Power Button " ( 3-3 , Fig. 1 )
> 2 seconds. will power off.
9
5) Start measurement by giving force (push or pull), then the
LCD will display the Average reading value.
Note :
* During the measurement, if intend to change
the display direction, just push the " Reverse
Button " ( 3-7, Fig. 1 ) once.
10
4-4 LCD Back Light On/Off
During the measurement, press the " BACKLIGHT Button "
( 3-3, Fig. 1 ) once the LCD Back Light will be ON. During
the LCD Back Light ON, press the " BACKLIGHT Button "
once again, the LCD Back Light will be OFF again.
5. DATALOGGER
5-1 Preparation before execute datalogger function
a. Insert the SD card
b. SD card Format
If SD card just the first time use into the meter, it
recommend to make the " SD card Format " at first. ,
please refer chapter 7-1, page 20.
* It recommend strongly, do not use memory cards that
have been formatted by other meter or by a computer.
Reformat the memory card with your meter.
c. Time setting
If the meter is used at first time, it should to adjust the
clock time exactly, please refer chapter 7-2, page 20.
11
d. Decimal format setting
The numerical data structure of SD card is
default used the " . " as the decimal, for
example "20.6" "1000.53" . But in certain
countries ( Europe ...) is used the " , " as the
decimal point, for example " 20, 6 "
"1000,53". Under such situation, it should
change the Decimal character at first, details
of setting the Decimal point, refer to Chapter
7-8, page 24.
Remark :
* How to set the sampling time, refer to Chapter 7-3
page 21.
* How to set the beeper sound is enable, refer to
Chapter 7-6, page 23.
12
b. Pause the datalogger
Remark :
If press the " Logger Button " ( 3-9, Fig. 1 ) once again
will execute the Datalogger again, the bottom text of
DATA RECORD " will flashing .
13
Remark :
During execute the Manual Datalogger, press the " ▲
Button " ( 3-4, Fig, 1 ) or " ▼ Button " ( 3-7, Fig. 1 ) to
set the measuring Location no. ( 1 to 99, for example
room 1 to room 99 ) to identify the measurement location
, the lower Display will show P x ( x = 1 to 99 ).
Remark :
* How to set the sampling time, refer to Chapter 7-4
page 22.
14
* When the peak value is got, the LCD indicator "
DATA RECORD " will be disappeared . The indicator
will show " PEAK " indicator only, in the same time
the peak value will freeze on the Display
* Following the bottom LCD will show the data record
no. and count down to zero, in the same time all the
memory data will save into the SD memory card.
FGA01
15
2) If the first time to execute the Datalogger,
under the route FGA01\, will generate a new
file name FGA01001.XLS.
After exist the Datalogger, then execute again,
the data will save to the FGA01001.XLS until
Data column reach to 30,000 columns, then
will generate a new file, for example FGA01002.XLS
3) Under the folder FGA01\, if the total files more
than 99 files, will generate anew route, such as
FGA02\ ........
4) The file's route structure :
FGA01\
FGA01001.XLS
FGA01002.XLS
.....................
FGA01099.XLS
FGA02\
FGA02001.XLS
FGA02002.XLS
.....................
FGA02099.XLS
FGAXX\
.....................
.....................
Remark :
XX : Max. value is 10.
16
6. Saving data from the SD card
to the computer ( EXCEL software )
1) After execute the Data Logger function, take away the
SD card out from the " SD card socket " ( 3-20, Fig. 1 ).
2) Plug in the SD card into the Computer's SD card slot
( if your computer build in this installation ) or
insert the SD card into the " SD card adapter ". then
connect the " SD card adapter " into the computer.
3) Power ON the computer and run the " EXCEL software ".
Down load the saving data file ( for example the file
name : FGA01001.XLS, FGA01002.XLS ) from the SD
card to the computer. The saving data will present into
the EXCEL software screen ( for example as following
EXCEL data screens ) , then user can use those EXCEL
data to make the further Data or Graphic analysis
usefully.
17
EXCEL data screen ( for example, peak hold record mode )
18
EXCEL graphic screen ( for example, graphic 2 )
7. ADVANCED SETTING
Under do not execute the Datalogger function,
press the " SET Button " ( 3-8, Fig. 1 ) continuously at
least two seconds will enter the " Advanced Setting " mode.
then press the " SET Button " ( 3-8, Fig. 1 ) once a while
in sequence to select the eight main function, the
display will show :
19
Remark :
During execute the " Advanced Setting " function,
if press " ESC Button " ( 3-5, Fig. 1 ) will exit the
" Advanced Setting " function, the LCD will return
to normal screen.
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button " (
3-7, Fig. 1 ) to select the upper value to " yES " or
" no ".
yES - Intend to format the SD memory card
no - Not execute the SD memory card format
2) If select the upper to " yES ", press the " Enter Button
" ( 3-6, Fig. 1 ) once again, the Display will show text
" yES Enter " to confirm again, if make sure to do the
SD memory card format, then press " Enter Button "
once will format the SD memory clear all the existing
data that already saving into the SD card.
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button "
( 3-7, Fig. 1 ) to adjust the value ( Setting start from
Year value ). After the desired value is set, press the
" Enter Button " ( 3-6, Fig. 1 ) once will going to
next value adjustment ( for example, first setting
value is Year then next to adjust Month, Date, Hour,
Minute, Second value ).
Remark : The adjusted value will be flashed.
20
2) After set all the time value ( Year, Month, Date, Hour,
Minute, Second ), press the " SET Button " ( 3-8, Fig.
1 ) once will save the time value, then the screen will
jump to Sampling time " setting screen ( Chapter 7-3 ).
Remark :
After the time value is setting, the internal clock will
run precisely even Power off if the battery is under
normal condition ( No low battery power ).
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button "
( 3-7, Fig. 1 ) to adjust the value ( Setting start from
Hour value ). After the desired value is set, press the
" Enter Button " ( 3-6, Fig. 1 ) once will going to next
value adjustment ( for example, first setting value is
Hour then next to adjust Minute, Second value ).
Remark :
The adjusted value will be flashed.
21
7-4 Set sampling time for peak record mode
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button "
( 3-7, Fig. 1 ) to adjust the value ( adjust unit is milli
seconds, each step is 10 ms, setting start from 10 ms ).
After the desired value is set, press the " Enter Button "
( 3-6, Fig. 1 ) will save the setting value with default.
Remark :
The adjusted value range is from 10 ms to 500 ms,
2) After set the sampling time value, press the " SET
Button " ( 3-6, Fig. 1 ) once the screen will jump to "
Auto power OFF " setting screen ( Chapter 7-5 ).
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button "
( 3-7, Fig. 1 ) to select the upper value to " yES " or
" no ".
2) After select the upper text to " yES " or " no ", press the
" Enter Button " ( 3-6, Fig. 1 ) will save the setting
function with default.
22
7-6 Set beeper sound ON/OFF
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button "
( 3-7, Fig. 1 ) to select the upper value to " yES " or
" no ".
2) After select the upper text to " yES " or " no ", press the
" Enter Button " ( 3-6, Fig. 1 ) will save the setting
function with default.
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button "
( 3-7, Fig. 1 ) to select the measurement unit in
" g ", " oz ", " N ", in the same time the upper LCD
will show the full scale value for the corresponding
measurement unit.
Remark :
g - Gram, full scale is 5000 g
oz - Ounce , full scale is 176.35 oz
N - Newton , full scale is 49.03 N.
23
7-8 Decimal point of SD card setting
The numerical data structure of SD card is default used
the " . " as the decimal, for example "20.6" "1000.53" .
But in certain countries ( Europe ...) is used the " , " as
the decimal point, for example " 20,6 " "1000,53".
Under such situation, it should change the Decimal
character at first.
1) Use the " ▲ Button " ( 3-4, Fig. 1 ) or " ▼ Button "
( 3-7, Fig. 1 ) to select the upper text to " bASIC " or
" Euro ".
2) After select the upper text to " USA " or " Euro ",
press the " Enter Button " ( 3-6, Fig. 1 ) will save the
setting function with default.
7-9 ESC
When the Display show the text " ESC ", then press the
" SET Button " ( 3-8, Fig. 1 ) or " ESC Button " ( 3-5, Fig. 1 )
will finish the Advanced Setting procedures.
Remark :
During execute the " Advanced Setting " function,
if press " ESC Button " ( 3-5, Fig. 1 ) will exit the
" Advanced Setting " function, the LCD will return
to normal screen.
24
8. POWER SUPPLY from DC
ADAPTER
The meter also can supply the power supply from the
DC 9V Power Adapter ( optional ). Insert the plug of
Power Adapter into " DC 9V Power Adapter Input Socket
" ( 3-12, Fig. 1 ). The meter will permanent power ON
when use the DC ADAPTER power supply ( The power
Button function is disable ).
9. BATTERY REPLACEMENT
1) When the left corner of LCD display show " ", it
is necessary to replace the battery. However, in-spec.
measurement may still be made for several hours after
low battery indicator appears before the instrument
become inaccurate.
2) Loose the screws of the " Battery Cover " ( 3-14, Fig. 1 )
and take away the " Battery Cover " from the instrument
and remove the battery.
3) Replace with DC 1.5 V battery ( UM3, AA,
Alkaline/heavy duty ) x 6 PCs, and reinstate the cover.
4) Make sure the battery cover is secured after changing batteries.
Meter PC
(9W 'D" Connector)
Center Pin..........................Pin 4
(3.5 mm jack plug)
Ground/shield.......................Pin 2
2.2 K
resister
Pin 5
26
D10 Polarity
0 = Positive 1 = Negative
D9 Decimal Point(DP), position from right to the
left
0 = No DP, 1= 1 DP, 2 = 2 DP, 3 = 3 DP
D8 to D1 Display reading, D1 = LSD, D8 = MSD
For example :
If the display reading is 1234, then D8 to D1 is : 1234
D0 End Word
27
b. WEDGE GRIP, Model : WG-01
Wedge grip, the optional accessory to install to the base
of FS-1001 be used to hold the tested material.
FS-1001
WG-01
28
13. APPLICATIONS
13-1 Electronics
* Test strength of solder points and spot welds on circuit
boards.
* Test wire wraps on clip connection.
* Test pull strength of modified wire wrap connection on
posts.
* Test spring clip insertion and withdrawal forces.
* Pull test welds in micro-electronic devices.
* Measure torque, timing belt tension, sliding friction, etc.,
on computer peripheral equipment.
* Test P.C. board insertion force.
* Test insertion and withdrawal forces of various circuit
components such as transistors and integrated circuits.
* Test actuating force of snap action switches.
29
13-3 Chemical & Plastics
* Test film bond strengths.
* Tensile test rubber, fibers and filaments.
* Measure firmness of polyurethane foam.
* Test crush strength of pills (medicine)
* Test peel strength of adhesives.
* measure compression of ceramic compounds.
* Test vacuum take-down pressure on process machines.
13-5 Automotive
* Measure force of seat belt retractors.
* Measure arm pressure of windshield wipers.
* Measure flip force in mechanical snap action switches.
* Test effort to operate hand tool.
* Test forces required to move linkages and tension cables.
* Measure force of odometer pull.
* Test peel strength of vinyl insert bonded to body side
moldings
* Evaluate physical efforts (door, look, hood, glove
compartment, brake pedal, etc.).
30
13-6 Other Industries
* Measure pedal depression force in aircraft.
* Test hardness of gypsum wallboard.
* Test keyboard and pedal contact force of organs and
pianos.
* Test force to remove cover tops of aerosol cans.
* Measure trigger pulling forces on firearms, hand tools etc.
* Test firmness of sausages in casings.
* Test integrity of seals on blister packages and plastic bags.
* Test pressure of surgical instruments (forceps, scissors).
* Test fruit removal force and fruit firmness.
* Measure force on spindles of photographic equipment
31
1403-FG6005SD