100% found this document useful (1 vote)
811 views6 pages

SST Pac 5000 Steam Turbine Package Interactive Presentation

The document summarizes the Siemens SST-PAC 5000 steam turbine package. Key points: - The SST-5000 is used in combined cycle power plants and coal-fired steam plants, and achieved a world-class efficiency of 61.5% in one plant. - It consists of a high-pressure/intermediate-pressure turbine and one or two low-pressure turbines. Extractions are possible for feedwater heating. - Customer benefits include world-class efficiency and flexibility, with long maintenance intervals to reduce lifecycle costs. - Technical data provided include power output ranges, steam conditions, generator details, and efficiency specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
811 views6 pages

SST Pac 5000 Steam Turbine Package Interactive Presentation

The document summarizes the Siemens SST-PAC 5000 steam turbine package. Key points: - The SST-5000 is used in combined cycle power plants and coal-fired steam plants, and achieved a world-class efficiency of 61.5% in one plant. - It consists of a high-pressure/intermediate-pressure turbine and one or two low-pressure turbines. Extractions are possible for feedwater heating. - Customer benefits include world-class efficiency and flexibility, with long maintenance intervals to reduce lifecycle costs. - Technical data provided include power output ranges, steam conditions, generator details, and efficiency specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

SST-PAC 5000

Steam Turbine Package

This PDF offers an advanced interactive experience.


For the best viewing experience, please use Acrobat Reader X or higher.

Version 2 siemens.com/steamturbines
Siemens SST-PAC 5000 Best efficiency High flexibility

Responsible fuel handling is becoming more and


Siemens Steam Turbine packages SST-PAC 5000 are Preassembled modules reduce coordination effort, on-
more important for reducing CO2 emissions.
operated in combined cycle power plants (CCPP) and in site assembly time, and technical risk.
The Organisation for Economic Co-operation and
coal-fired steam power plants (SPP). The SST-5000 steam
The SST-5000 series consists of a combined high-pres- Development (OECD) recently addressed the environ-
turbine combined with a SGT-8000H gas turbine and a
sure/intermediate-pressure (HP-IP) turbine, and one or mental requirements as a precondition for export
Siemens generator, achieved a world class efficiency
two low-pressure (LP) turbines. financing for the entire range of coal-fired power
of 61.5 percent in the CCPP Lausward.
Various extractions are possible for feedwater heating (up plants.
The steam turbine package is installed as a low- or high- Therefore the technology needs to be developed
to 9 stages), process steam, and district heating.
level arrangement. There are various exhaust configura- continuously to meet these environmental demands.
tions available to create an optimized plant layout:
bottom, single-sided and double-sided. Going forward, the good experiences gained from
existing high-end ultra-supercritical (USC) coal-fired
power plants have been transferred to power plants
4 of the 350-MW size with the SST-PAC 5000.

Siemens has extended the capability of its SST-PAC


5000 for supercritical and ultra-supercritical steam
parameters. They can now be deployed in the out-
put range of 250 to 500 MW.

2 7 6

1
5 Customer benefits

3
Performance Flexibility Availability Trusted partnership

[1] High-pressure/intermediate-
pressure turbine
• World-class efficiency and combined heat and power
[2] Low-pressure turbine
[3] Valve • Long maintenance intervals to reduce lifecycle costs
[4] Crossover pipe
[5] Bearing • Flexible steam extractions
[6] Generator
[7] Stator winding
Technical data Generator Instrumentation and
controls

Power output: Steam conditions CCPP: Siemens SGen-2000P series


• CCPP: 120 to 650 MW • Main steam pressure up to 177 bar / 2,567 psi Siemens SGen-2000P series pressurized air-cooled gen-
• SPP: 250 to 500 MW • Temperature up to 600 °C / 1,112 °F erators with ratings up to 550 MVA are used in simple
• Reheat temperature up to 610 °C / 1,130 °F cycle, combined cycle, and steam power plants.
Frequency: 50 or 60 Hz The SGen-2000P series features pressurized-air cool-
Steam conditions SPP:
Speed: 3,000 or 3,600 rpm ing with a water-cooled stator winding. Replacing
• Main steam pressure up to 260 bar / 3,771 psi
• Temperature up to 600 °C / 1,112 °F hydrogen cooling with pressurized air significantly
• Reheat temperature up to 600 °C / 1,112 °F reduces plant complexity and lowers total costs of
Efficiency: ownership (installation, service, operation).
• CCPP: 61.5 % net plant efficiency (2016 Lausward)
• SPP: 53.0 % turbine efficiency Power factor generator: The components of the SGen-2000P series have been
• 50 Hz: 0.80 proven over decades of operation.
• 60 Hz: 0.85 – 0.95
Last stage blade length:
• 50 Hz: 66 to 142 cm / 26 to 56 inches Siemens SGen-1200A series
• 60 Hz: 66 to 95 cm / 26 to 38 inches
The SGen-1200A air-cooled two-pole generator series
[1] Blade ring
has ratings up to 370 MVA for steam, gas, and com-
[2] LP turbine blading bined cycle applications.
[3] Turning gear
[4] HI turbine blading
[5] Push rod Both generators serve all operational modes, from
[6] Seals base load to peaking operation, with excellent
operational flexibility.

6 1
4
5

SGen-2000P rotor
Maintenance of SST-5000 Assembly
Combined high-pressure/intermediate-pressure
turbine modules are delivered to site completely assem-
Unit Years 3 years 6 years 9 years 12 years ** bled – this allows a fast and simple on-site installation.

The low-pressure turbine components are designed for


optimized site assembly lead time.
Minor, medium and major inspections including the generator

EOH* 25,000 50,000 75,000 100,000 **

Minor Minor
Inspection
Medium Inspection

Inspection Major
Inspection

[ ~ 2 weeks ] [ ~ 3 weeks ] [ ~ 2 weeks ] [ ~ 6 weeks ]***

First opening
*EOH = Equivalent Operating Hours of Steam Turbine
**Estimated values (base load)
Modules Auxiliaries
***Depending on shift mode and customer requirements
The core turbine modules as well as the auxiliary systems
are designed for maximum customer value:

Medium Inspection Major Inspection Lube oil system, seal oil system, seal steam system, con-
Minor Inspection
denser air removal system, and additional systems.

Visual inspection of accessible components, including These are completely preassembled modules for easy and
condenser fast connection to the related piping and electrical systems.
sy
Functional checks on valve and control components
Minor Alignment checks
Inspection
Optional: Inspection of non-accessible areas with
boroscope
Opening of HP casing:

Condenser air removal system


Reference examples Combined cycle power plant.

SCC5-8000H 1S (single shaft)


Lausward “Fortuna”, Germany

2
5
4

The power plant has broken three world records: in the


acceptance test a maximum electrical net output of
603.8 MW was achieved and the net energy conversion
[1] Lausward, Germany efficiency was around 61.5 percent.
In addition, “Fortuna” can also deliver up to around 300 MW
[2] Dangjin III, South Korea
for the district heating system of the city of Düsseldorf – a
further international peak value for a power plant equipped
[3] Nhon Trach II, Vietnam
with only one gas and steam turbine. This increases the
overall efficiency of natural gas as a fuel to 85 percent.
[4] Panda Temple, Texas, USA

[5] Yangcheng, China Commercial operation: 2016 learn more

Power output: 604 MW


Switch to printable overview

Efficiency: > 61.5%*


5

*Plant net efficiency


Published by:
Siemens AG 2017

Power and Gas Division


Freyeslebenstr. 1
91058 Erlangen
Germany

Customer Support Center:


Phone +49 / (0) 180 / 524 70 00
Fax +49 / (0) 180 / 524 24 71
(Charges depending on provider)
E-mail: [email protected]

Subject to changes and errors. The information given in


this document only contains general descriptions and/or
performance features which may not always specifically
reflect those described, or which may undergo modifica-
tion in the course of further development of the products.
The requested performance features are binding only
when they are expressly agreed upon in the concluded
contract. © 02.2017 Siemens AG