0% found this document useful (0 votes)
27 views1 page

FOX - P 21 FOX - FOX - 208V - 60Hz - En-1

This document provides technical specifications for a P 21 FOX generator including its dimensions, weight, engine details, alternator details, and canopy information. It lists the generator's continuous and standby power ratings, voltage and frequency capabilities, and fuel consumption rates at various loads. Technical data on the Perkins 404A-22G1 engine and STAMFORD alternator are also given.

Uploaded by

skl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views1 page

FOX - P 21 FOX - FOX - 208V - 60Hz - En-1

This document provides technical specifications for a P 21 FOX generator including its dimensions, weight, engine details, alternator details, and canopy information. It lists the generator's continuous and standby power ratings, voltage and frequency capabilities, and fuel consumption rates at various loads. Technical data on the Perkins 404A-22G1 engine and STAMFORD alternator are also given.

Uploaded by

skl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TECHNICAL DATASHEET P 21 FOX

P 21 FOX

FOX “FOX” MAIN DATA


Continuous power (PRP) 24.00 kVA

Continuous power (PRP) 19.20 kW

Stand-by power (LTP) 26.60 kVA

Stand-by power (LTP) 21.28 kW

VAC - HZ - cos(fi) 208 - 60 - 0.8

DIMENSIONS AND WEIGHT


Width 770 mm
Length 1660 mm
For illustrative purposes only
Height 1350 mm

ENGINE Weight 730 kg

Description PERKINS
Engine model 404A-22G1
Cylinders 4 ALTERNATOR
RPM speed 1800 Description STAMFORD

Cubic capacity 2.22 l Alternator model S0L2-P

Air intake Aspirated P.R.P. Power 31.7 kVA

Standard voltage 12 Vdc L.T.P. Power 34.8 kVA

Optional voltage Vdc Connection Parallel star

Sae 4-7 Phases 3FN

BMEP 658 kPa Winding 311

Cooling Water Terminal Number 12 nr.

Flywheel P.R.P. Power net 21.6 kW IP Protection 23

Flywheel Stand-by Power net 23.9 kW Electronic regulator AS540

Fuel Cons. at 100% (L.T.P.) 7.3 l/h Precision 1 ±%

Fuel Cons. at 100% (P.R.P) 6.4 l/h


BASEFRAME
Fuel Cons. at 75% (P.R.P.) 4.8 l/h
Model FOX
Fuel Cons. at 50% (P.R.P.) 3.5 l/h
Standard tank 50 l
Fuel Cons. at 25% (P.R.P.) 0.0 l/h
Optional tank 600 l
Electronic regulator On request
Oversized tank* 0 l
Precision class G2
Oil quantity 10.6 l CANOPY & SILENCER
Engine Antifreeze capacity 3.6 l Canopy model FOX

Radiator type TR Silencer model F50/02

Heat from radiator 19.9 kW Silencer outlet diameter 50 mm


Standard reference conditions temperature 25°C, altitude 100m asl, relative humidity 30%,
Heat from exhaust 16.6 kW atmospheric pressure 100 kPa (1 bar), power factor 0.8 lag, balanced load - non
distortional. Fuel consumption is nominal and refers to specific weight 0,850kg/l. Sound
Heat from radiation 3.8 kW power values refer to free field conditions: the installation site may influence the values.
Dimensions, weights and other specifications contained in the technical data sheet and
Exhaust temperature 440 °C related attachments are nominal, subject to tolerances and refer to the model with standard
equipment; any optional and additional equipment/accessories can modify weight,
Cooling air flow 39.6 m³/min dimensions, performance.
P.R.P. Prime Power-Continuous power at variable load: The power that a genset can
Combustion air flow 1.7 m³/min supply in continuous service at a variable load for an unlimited number of hours per year
while respecting the maintenance intervals established in the environmental conditions
Exhaust gas flow 4.3 m³/min stated by the Manufacturer. according to ISO8528-1. The average power supplied over time
and any applicable overload must be less than the percentages stated by the Manufacturer.
TA Luft N L.T.P. Limited-time running power-Limited power: The maximum power that a genset
can supply for a limited time respecting the maintenance intervals established in the
TA Luft/2 N environmental conditions stated by the Manufacturer according to ISO 8528-1.The number
of hours per year is stated by the Manufacturer. Overload is not permitted.
EPA N
Stage N

The data contained in this document is nominal and refers to the standard equipped model and is not binding. Visa S.p.A. reserves the
right to revise the information without notice per our policy of continuous product development and improvement.

VISA S.p.A. - ITALY- CERTIFIED ISO 9001-2015, 14001-2015, 3834 and EN 1090 - www.visa.it
Visa S.p.A. is subject to management and coordination of ENERGY S.p.A. - Milano, via Dante 14 - Milano Company registration Office n. 12616930967

Powered by TCPDF (www.tcpdf.org)