TECHNICAL DATASHEET P 21 FOX
P 21 FOX
FOX “FOX” MAIN DATA
Continuous power (PRP) 24.00 kVA
Continuous power (PRP) 19.20 kW
Stand-by power (LTP) 26.60 kVA
Stand-by power (LTP) 21.28 kW
VAC - HZ - cos(fi) 208 - 60 - 0.8
DIMENSIONS AND WEIGHT
Width 770 mm
Length 1660 mm
For illustrative purposes only
Height 1350 mm
ENGINE Weight 730 kg
Description PERKINS
Engine model 404A-22G1
Cylinders 4 ALTERNATOR
RPM speed 1800 Description STAMFORD
Cubic capacity 2.22 l Alternator model S0L2-P
Air intake Aspirated P.R.P. Power 31.7 kVA
Standard voltage 12 Vdc L.T.P. Power 34.8 kVA
Optional voltage Vdc Connection Parallel star
Sae 4-7 Phases 3FN
BMEP 658 kPa Winding 311
Cooling Water Terminal Number 12 nr.
Flywheel P.R.P. Power net 21.6 kW IP Protection 23
Flywheel Stand-by Power net 23.9 kW Electronic regulator AS540
Fuel Cons. at 100% (L.T.P.) 7.3 l/h Precision 1 ±%
Fuel Cons. at 100% (P.R.P) 6.4 l/h
BASEFRAME
Fuel Cons. at 75% (P.R.P.) 4.8 l/h
Model FOX
Fuel Cons. at 50% (P.R.P.) 3.5 l/h
Standard tank 50 l
Fuel Cons. at 25% (P.R.P.) 0.0 l/h
Optional tank 600 l
Electronic regulator On request
Oversized tank* 0 l
Precision class G2
Oil quantity 10.6 l CANOPY & SILENCER
Engine Antifreeze capacity 3.6 l Canopy model FOX
Radiator type TR Silencer model F50/02
Heat from radiator 19.9 kW Silencer outlet diameter 50 mm
Standard reference conditions temperature 25°C, altitude 100m asl, relative humidity 30%,
Heat from exhaust 16.6 kW atmospheric pressure 100 kPa (1 bar), power factor 0.8 lag, balanced load - non
distortional. Fuel consumption is nominal and refers to specific weight 0,850kg/l. Sound
Heat from radiation 3.8 kW power values refer to free field conditions: the installation site may influence the values.
Dimensions, weights and other specifications contained in the technical data sheet and
Exhaust temperature 440 °C related attachments are nominal, subject to tolerances and refer to the model with standard
equipment; any optional and additional equipment/accessories can modify weight,
Cooling air flow 39.6 m³/min dimensions, performance.
P.R.P. Prime Power-Continuous power at variable load: The power that a genset can
Combustion air flow 1.7 m³/min supply in continuous service at a variable load for an unlimited number of hours per year
while respecting the maintenance intervals established in the environmental conditions
Exhaust gas flow 4.3 m³/min stated by the Manufacturer. according to ISO8528-1. The average power supplied over time
and any applicable overload must be less than the percentages stated by the Manufacturer.
TA Luft N L.T.P. Limited-time running power-Limited power: The maximum power that a genset
can supply for a limited time respecting the maintenance intervals established in the
TA Luft/2 N environmental conditions stated by the Manufacturer according to ISO 8528-1.The number
of hours per year is stated by the Manufacturer. Overload is not permitted.
EPA N
Stage N
The data contained in this document is nominal and refers to the standard equipped model and is not binding. Visa S.p.A. reserves the
right to revise the information without notice per our policy of continuous product development and improvement.
VISA S.p.A. - ITALY- CERTIFIED ISO 9001-2015, 14001-2015, 3834 and EN 1090 - www.visa.it
Visa S.p.A. is subject to management and coordination of ENERGY S.p.A. - Milano, via Dante 14 - Milano Company registration Office n. 12616930967
Powered by TCPDF (www.tcpdf.org)