Data Sheet
2015 v1.0
MPM-MV24-2
DIN Rail Multifunction
Power Meter
• Milivolt Secondary Current Input
• Built In RS485 Modbus RTU
• Built In Dual Pulsed Outputs
• Configurable for Single & Three Phase Networks
• Import & Export kWh & KVArh
• 21-30V DC Auxiliary Supply
MPM-MV24-2
Multifunction Power Meter Parameters
The MPM-MV24-2 is a new generation modern design
power monitor that will measure and display electrical • Phase to Neutral • Reactive Power (kVAr)
power quality parameters. It has been engineered to Voltage (V)
cover most applications (Single Phase and Three Phase • Apparent Power (kVA)
networks / Built in Pulsed and RS485 Modbus / Import • Neutral Current (A)
and Export kWh), replacing the need for several different • Import Active Energy
models of this power meter. • Voltage Total Harmonic (kWh)
Distortion (U%THD)
• Export Active Energy
The MPM-MV24-2 is produced to the highest quality
• Current Total Harmonic (kWh)
and utilizes the latest microprocessor and technology.
It has a blue backlit display and 16 different measuring Distortion (I%THD)
• Total Active Energy
parameters. This includes a negative power reading to • Frequency (Hz) (kWh)
indicate reversal of CT installation or connection. With
built in pulsed outputs and RS485 Modbus RTU it is • Power Factor (PF) • Import Reactive Energy
fully compatible for integration with BMS and remote (kVArh)
monitoring systems. • Current Max Demand
(MD A) • Export Reactive Energy
This particular model works in comparison with milivolt (kVArh)
current transformers, unlike other mV meters, you can • Power Max Demand
configure the secondary on this meter to be 333mV or (MD kW) • Total Reactive Energy
340mV. (kVArh)
• Active Power (kW)
MPM-MV24-2 DIN Rail Smart Energy Meter for Single and Three Phase Electrical Systems | Data Sheet 2015 v1.0
Specifications
Measured Parameters
The unit can monitor and display the following parameters of a single phase two wire (1P2W), three phase three wire (3P3W) or three phase four wire (3P4W) system.
Voltage and Current
• Phase to neutral voltages 100 to 289V AC (not for 3P3W supplies).
• Voltages between phases 173 to 500V AC (three phase supplies only).
• Percentage total voltage harmonic distortion (U%THD) for each phase to N (not for 3P3W supplies).
• Percentage voltage U%THD between phases (three phase supplies only).
• Current I%THD for each phase.
Power factor, Frequency and Max. Demand
• Frequency in Hz.
• Instantaneous power:
• Power 0 to 3600 MW
• Reactive power 0 to 3600 MVAr
• Volt-amps 0 to 3600 MVA
• Maximum demand power since last Demand reset Power factor.
• Maximum neutral demand current, since the last Demand reset (three phase supplies only).
Energy Measurements
Imported/Exported active energy 0 to 9999999.9 kWh
Imported/Exported reactive energy 0 to 9999999.9 kVArh
Total active energy 0 to 9999999.9 kWh
Total reactive energy 0 to 9999999.9 kVArh
Measured Inputs
Voltage inputs through 4-way fixed connector with 2.5mm² stranded wire capacity. single phase two wire(1P2W), three phase three wire(3P3W) or three phase four wire(3P4W) unbalanced.
Line frequency measured from L1 voltage or L3 voltage. Three current inputs (six physical terminals) with 2.5mm² stranded wire capacity for connection of external CTs. Nominal rated input
current 0.333V AC or 0.340V AC.
Nominal Voltage Input (Ph+N) 100 to 289V (Ph+Ph) 173 to-500V
Max Continuous Voltage 120% of nominal
Nominal Input Current 0.333V AC or 0.340V AC (configurable)
Max Continuous Current 120% of nominal
Nominal Input Current Burden 0.5VA
Frequency 50Hz
Accuracy
Voltage 0·5% of range maximum
Current 0·5% of nominal
Frequency 0·2% of mid-frequency
Power factor 1% of unity (0.01)
Active power (W) ±1% of range maximum
Reactive power (VAr) ±1% of range maximum
Apparent power (VA) ±1% of range maximum
Active energy (Wh) Class 1 IEC 62053-21
Reactive energy (VARh) ±1% of range maximum
Total harmonic distortion 1% up to 31st harmonic
Response time to step input 1s, typical, to >99% of final reading, at 50 Hz.
| Data Sheet 2015 v1.0
MPM-MV24-2 DIN Rail Smart Energy Meter for Single and Three Phase Electrical Systems
Auxiliary Supply
Two-way fixed connector with 2·5mm² stranded wire capacity. Consumption <2W 10VA.
Operating range 21-30V DC
Interfaces for External Monitoring
Three interfaces are provided:
• RS485 communication channel that can be programmed for Modbus RTU protocol
• Relay output indicating real-time measured energy.(configurable)
• Pulse output 3200imp/kWh (not configurable)
The Modbus configuration (baud rate etc.) and the pulse relay output assignments (kW/kVArh, import/export etc.) are configured through the set-up screens.
Pulse Output
Opto-coupler with potential free SPST-NO Contact (Contact range 5-27VDC / Max current input: Imin 2mA and Imax 27mA DC).
The pulse output can be set to generate pulses to represent kWh or kVArh.
Rate can be set to generate 1 pulse per:
0.01 = 10 Wh/VArh
0.1 = 100 Wh/VArh
1 = (1000 Wh) 1 kWh/kVArh
10 = 10 kWh/kVArh
100 = 100 kWh/kVArh
Pulse width 200/100/60 ms.
RS485 Output for Modbus RTU
For Modbus RTU, the following RS485 communication parameters can be configured from the set-up menu:
Baud rate 2400, 4800, 9600, 19200, 38400
Parity none (default) / odd / even
Stop bits 1 or 2
RS485 network address – 3-digit number, 1 to 247
Modbus™ Word order Hi/Lo byte order is set automatically to normal or reverse. It cannot be configured from the set-up menu.
Reference Conditions of Influence Quantities
Influence Quantities are variables that affect measurement errors to a minor degree. Accuracy is verified under nominal value (within the specified tolerance) of these conditions.
Ambient temperature 23°C ±1°C
Input waveform 50 or 60Hz ±2%
Input waveform Sinusoidal (distortion factor < 0·005)
Auxiliary supply voltage Nominal ±1%
Auxiliary supply frequency Nominal ±1%
Auxiliary supply waveform (if AC) Sinusoidal (distortion factor < 0·05)
Magnetic field of external origin Terrestrial flux
Environment
Operating temperature -25°C to +55°C*
Storage temperature -40°C to +70°C*
Relative humidity 0 to 95%, non-condensing
Altitude Up to 3000m
Warm up time 1 minute
Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Shock 30g in 3 planes
*Maximum operating and storage temperatures are in the context of typical daily and seasonal variation.
MPM-MV24-2 DIN Rail Smart Energy Meter for Single and Three Phase Electrical Systems | Data Sheet 2015 v1.0
Mechanics
DIN rail dimensions 72 x 94.5 mm (WxH) per DIN 43880
Mounting DIN rail (DIN 43880)
Sealing IP51 indoor
Material Self-extinguishing UL 94 V-0
Dimensions
Installation
Single phase two wires Three phase three wires Three phase four wires
P1
S2
L1 P1
S2
L1
P1 L1 LOAD
P1
S2
L1 S2 P1 L1 L2 LOAD
P1 P1 P1 L1
L1 S2 L2
S2 S2 S2
LOAD P1 L1 P1 L1 LOAD L2 P1 L2 LOAD P1
L2
S2L2
P1
S2 LOAD L3 LOAD P1 L3
OAD LOAD S2 S2 S2 S2
GND
P1 P1
GND S2 L3 L3 P1 P1
GND S2 L3 L3
S2 S2
1 B A 1 B A 1 B A
GND GND GND GND GND GND
1 B A 1 B A 1 B A1 B A 1 B 1A B A
S0 RS485 Current inputs S0 RS485 Current inputs S0 RS485 Current inputs
S0 RS485
RS485 S0 Current inputs Current inputs S0 RS485S0 RS485
Current inputs Current inputs S0 S0
RS485 RS485 inputs
Current Current inputs
9 10 11 12 13 14 15 16 17 18 19 20 9 10 11 12 13 14 15 16 17 18 19 20 9 10 11 12 13 14 15 16 17 18 19 20
9 10 11 12 13 149 15
1016
11 17
12 18
13 19
14 15
20 16 17 18 19 20 9 10 11 12 13914101511161217
1318
1419
1520
16 17 18 19 20 9 10
9 10 11 12 13 14 11
1512
1613
1714
1815
19162017 18 19 20
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
1 2 3 4 5 7
6 Voltage8inputs L N L N 1 2 3 4 5 6Voltage
7 inputs
8 L N L N 1 2 3 4 5 Voltage
6 7inputs
8 L N L N
Voltage inputs L N L N Voltage inputs L N L N Voltage inputs L N L N
Voltage inputs L N L N Voltage inputs L N L N Voltage inputs L N L N
+24V 0V +24V 0V +24V 0V
L1 +24V 0V
L1 +24V 0V
L1 +24V 0V
L1 +24V 0V L1 L2
+24V 0V L1 L2 +24V 0V
L1 N L1 L1
N L2 L3 L2 L3
N L2 L3
L2
L3 N
L3 L3
N
N
Specifications are subject to change without notice.
MPM-MV24-2 | Data Sheet 2015 v1.0
DIN Rail Smart Energy Meter for Single and Three Phase Electrical Systems