0% found this document useful (0 votes)
161 views2 pages

Catalog Cable Glands

These cable glands provide increased safety and flameproof protection for armored cables in hazardous locations. They feature an elastomer seal and detachable armor cone that allows inspection and disconnection of cables without losing enclosure protection. The glands are available in a range of sizes for different cable diameters and thread types.

Uploaded by

Alejandro Jose
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
161 views2 pages

Catalog Cable Glands

These cable glands provide increased safety and flameproof protection for armored cables in hazardous locations. They feature an elastomer seal and detachable armor cone that allows inspection and disconnection of cables without losing enclosure protection. The glands are available in a range of sizes for different cable diameters and thread types.

Uploaded by

Alejandro Jose
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

E1FW Nickel Plated Brass Cable Glands

Increased Safety and Flameproof


With Elastomer Seal for Armored Cables.
NEC/CEC: ATEX/IECEx:
Class I, Division 2, Groups A, B, C, D II 2GD, II 1D Ex d IIC Gb, Ex e IIC Gb,
Class II, Division 2, Groups E, F and G Ex ta IIIC Da
Class III II 3G Ex nR IIC Gc, I M2 Ex d I Mb, Ex e I Mb
Class I, Zone 1, AEx e II, AEx nR II
Ex d IIC, Ex e IIC, Ex nR II
Type 3, 4 and 4X
Hazardous Location Fittings: ATEX/IECEx Flameproof Cable Glands

Applications • Inspection of the armor can be carried out while still


maintaining the protection mode of the enclosure.
• Cable gland for Single Wire Armored cables (SWA with wire
and lead sheath) certified for enclosures with the following Standard Materials
protection modes: • Body: nickel plated brass
— Ex d flameproof IIB or IIC (as per §10.4.2 of IEC 60079-14) • Seal: LSF (Low Smoke Fume) thermoplastic elastomer
(Refer to the ATX Guide for Use of Electrical Products in — Inner displacement seal and LRS (Load Retention seal)
Hazardous Locations) outer seal
— Ex e increased safety
— Ex nR restricted breathing Options
— D dust environment • Lead sheath version – Replace digit E1 with E2;
• Hazardous areas (gas and dust). Example: 32E1FW5 - 32E2FW5
• Onshore and offshore. • Copper-free aluminum: replace last digit 5 with 1
Features • Shroud, locknut, earth tag, entry thread seal, serrated washers,
adaptors and reducers: see Cable Gland Accessories pages.
• Cable gland with elastomer seal for use in hazardous areas with
Single Wire Armor (SWA) cable. NEC/CEC Certifications and Compliances
• The cable gland allows mechanical cable retention and • cCSAus Certified: 101909
earth continuity via cable armor termination.
• A detachable armor cone and AnyWay clamping ring
arrangement facilitates remote make off and enables
cable to be disconnected from the equipment.

Catalog Numbers
Cable
Gland Metric Standard PT Optional NPT
Size Thread C Standard Metric  C Standard NPT  C Optional NPT Thread 

20S16 M20 2016E1FW5 1/2 2016E1FW0505 3/4 2016E1FW0755

20S M20 20SE1FW5 1/2 20SE1FW0505 3/4 20SE1FW0755

20 M20 20E1FW5 1/2 20E1FW0505 3/4 20E1FW0755

25S M25 25SE1FW5 3/4 25SE1FW0755 1 25SE1FW1005

25 M25 25E1FW5 3/4 25E1FW0755 1 25E1FW1005

32 M32 32E1FW5 1 32E1FW1005 1-1/4 32E1FW1255

40 M40 40E1FW5 1-1/4 40E1FW1255 1-1/2 40E1FW1505

50S M50 50SE1FW5 1-1/2 50SE1FW1505 2 50SE1FW2005

50 M50 50E1FW5 2 50E1FW2005 2-1/2 50E1FW2505

63S M63 63SE1FW5 2 63SE1FW2005 2-1/2 63SE1FW2505

63 M63 63E1FW5 2-1/2 63E1FW2505 3 63E1FW3005

75S M75 75SE1FW5 2-1/2 75SE1FW2505 3 75SE1FW3005

75 M75 75E1FW5 3 75E1FW3005 3-1/2 75E1FW3505

90 M90 90E1FW5 3 90E1FW3005 3-1/2 90E1FW3505

100 M100 100E1FW5 4 100E1FW4005 5 100E1FW5005

115 M115 115E1FW5 4 115E1FW4005 5 115E1FW5005

130 M130 130E1FW5 5 130E1FW5005 6 130E1FW6005

 Entry thread seal not supplied, see Cable Gland Accessories and Tools.

618 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© September 2017
E1FW Nickel Plated Brass Cable Glands
Increased Safety and Flameproof
With Elastomer Seal for Armored Cables.
NEC/CEC: ATEX/IECEx:
Class I, Division 2, Groups A, B, C, D II 2GD, II 1D Ex d IIC Gb, Ex e IIC Gb,
Class II, Division 2, Groups E, F and G Ex ta IIIC Da
Class III II 3G Ex nR IIC Gc, I M2 Ex d I Mb, Ex e I Mb
Class I, Zone 1, AEx e II, AEx nR II
Ex d IIC, Ex e IIC, Ex nR II
Type 3, 4 and 4X

Hazardous Location Fittings: ATEX/IECEx Flameproof Cable Glands


ATEX/IECEx Certifications and Compliances
• Certification Type E1FX/Z - E2FX/Z
— Gas: Zones 1 and 2
– Type of Protection: Ex d IIC Gb, Ex e IIC Gb, Ex nR IIC Gc
— Dust: Zone 20
– Type of Protection: Ex ta IIIC Da
• Conforming to ATEX 94/9/CE: II 2G 3G 1D
• Ambient Temperature: -60 °C to +130 °C (-76 °F to +266 °F) Dimensions in Millimeters (Inches)
• CE Declaration of Conformity: DC07001
• ATEX Certificate: Sira 13ATEX1071X, Sira 13ATEX4077X E2FW Series
• IECEx Certificate: IECEx SIR 13.0026X, IECEx SIM 14.0007X
Optional Lead
• Other Certifications: KCC, CCOE/PESO (India)
D Sheath
• Marine Approval: LLOYDS, DNV, ABS B A C
• Index of Protection according EN/IEC 60529: IP66
• Deluge Protection Compliance: DTS01:91 (option available on
request only) 15 mm (0.59”)
F Minimum
INMETRO Certification Ring for lead sheath
• INMETRO Certificate: TUV 12.0618X
EURASEC Certification
• TC RU C-GB.ГБ05.B.00138

Cable Bedding Diameter Outer Cable Capacity


Nominal
mm (in) A mm (in) B
Cable Across Across Protrusion
Gland Corners Flats Length Optional Weight
Size Min Max Min Max mm (in) D mm (in) D mm (in) F PVC Shroud kg (oz)
20S16 3.1 (0.12) 8.6 (0.34) 6.1 (0.24) 13.2 (0.52) 26.4 (1.04) 24.0 (0.94) 58.5 (2.30) PVC04 0.16 (5.64)

20S 6.1 (0.24) 11.6 (0.46) 9.5 (0.37) 15.9 (0.63) 26.4 (1.04) 24.0 (0.94) 58.5 (2.30) PVC04 0.16 (5.64)

20 6.5 (0.26) 13.9 (0.55) 12.5 (0.49) 20.9 (0.82) 33.6 (1.32) 30.5 (1.20) 60.5 (2.38) PVC06 0.21 (7.41)

25S 11.1 (0.44) 19.9 (0.78) 14.0 (0.55) 22.0 (0.87) 41.3 (1.63) 37.5 (1.48) 67.5 (2.66) PVC09 0.33 (11.64)

25 11.1 (0.44) 19.9 (0.78) 18.2 (0.72) 26.2 (1.03) 41.3 (1.63) 37.5 (1.48) 67.5 (2.66) PVC09 0.33 (11.64)

32 17.0 (0.67) 26.2 (1.03) 23.7 (0.93) 33.9 (1.33) 50.6 (1.99) 46.0 (1.81) 69.5 (2.74) PVC11 0.45 (15.87)

40 22.0 (0.87) 32.1 (1.26) 27.9 (1.10) 40.4 (1.59) 60.5 (2.38) 55.0 (2.17) 780.0 (3.07) PVC15 0.66 (23.28)

50S 29.5 (1.16) 38.1 (1.50) 35.2 (1.39) 46.7 (1.84) 66.0 (2.60) 60.0 (2.36) 75.5 (2.97) PVC18 0.73 (25.75)

50 35.6 (1.40) 44.0 (1.73) 40.4 (1.59) 53.1 (2.09) 77.0 (3.03) 70.0 (2.76) 80.5 (3.17) PVC21 0.75 (26.45)

63S 40.1 (1.58) 49.9 (1.96) 45.6 (1.80) 59.4 (2.34) 82.5 (3.25) 75.0 (2.95) 91.5 (3.60) PVC23 1.34 (47.27)

63 47.2 (1.86) 55.9 (2.20) 54.6 (2.15) 65.9 (2.59) 88.0 (3.46) 80.0 (3.15) 92.0 (3.62) PVC25 1.44 (50.44)

75S 52.8 (2.08) 61.9 (2.44) 59.0 (2.32) 72.1 (2.84) 97.9 (3.85) 89.0 (3.50) 99.0 (3.90) PVC28 2.07 (73.02)

75 59.1 (2.33) 67.9 (2.67) 66.7 (2.63) 78.5 (3.09) 108.9 (4.29) 99.0 (3.90) 102.0 (4.02) PVC30 2.62 (92.42)

90 66.6 (2.62) 79.9 (3.15) 76.2 (3.00) 90.4 (3.56) 125.4 (4.94) 114.0 (4.49) 120.0 (4.72) PVC32 4.17 (147.09)

100 76.0 (2.99) 90.9 (3.58) 86.1 (3.39) 101.5 (4.00) 135.3 (5.33) 123.0 (4.84) 148.0 (5.83) LSF33 4.52 (159.44)

115 86.0 (3.39) 97.9 (3.85) 101.5 (4.00) 110.3 (4.34) 146.7 (5.78) 133.4 (5.25) 169.0 (6.65) LSF34 6.86 (241.98)

130 97.0 (3.82) 114.9 (4.52) 114.2 (4.50) 123.3 (4.85) 160.7 (6.33) 146.1 (5.75) 183.0 (7.20) LSF35 8.12 (286.42)