0% found this document useful (0 votes)
54 views1 page

Part68 Catalog ELMARK 2015 WEB

The document describes low voltage contactors with direct current coils called LP-1D. The contactors are used to switch on and off alternating current circuits and consumers operating in AC-3 conditions with frequent switching. They are suitable for consumers using 9A to 225A of power. The contactors have technical specifications including rated operating voltages of 12V to 220V DC for the coil and up to 690V for the power circuit. Dimensions and catalog numbers are provided for different models of the contactors.

Uploaded by

Dino Bradaric
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views1 page

Part68 Catalog ELMARK 2015 WEB

The document describes low voltage contactors with direct current coils called LP-1D. The contactors are used to switch on and off alternating current circuits and consumers operating in AC-3 conditions with frequent switching. They are suitable for consumers using 9A to 225A of power. The contactors have technical specifications including rated operating voltages of 12V to 220V DC for the coil and up to 690V for the power circuit. Dimensions and catalog numbers are provided for different models of the contactors.

Uploaded by

Dino Bradaric
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CONTACTORS

Low voltage contactors- LP-1D

Documents corresponding to the Low voltage contactors with direct current coil
product:
Standard EN60947-1; EN 60947-4-1 LP-1D 5 YEAR
WARRANTY
*for industrial
usage, 3 years
warranty

The products are in accordance


with the directives of EC “Low voltage The contactors LP1 D are alternating current contac- ƒƒ insulation voltage: 690V
directives (LVD) no. 2006/95/EC” and tors with DC operating of coil for control. The power ƒƒ Surge voltage wear resistance: >8000V
“Electromagnetic Compatibility Direc- plugs of the contactor are designed for control of ƒƒ Limits of the controlling coil voltage: operating
tives (EMC) no. 2004/108/EC” alternating current circuits and consumers operat- range of coil
ing in normal operating class AC-3 with frequently ƒƒ Joining terminal: screw terminal
switching on/off the consumer and dirty working en- ƒƒ Connecting:
vironment. The contactors are suitable for consumers àà flexible conductors with or without cable
with electrical power consumption from 9A to 225A. terminal
àà rigid conductors
Functions: ƒƒ Electrical wear resistance (number of cy-
ƒƒ switching on/off alternating current consumers in cles):≥10000000
direct current controlling schemes at controlling ƒƒ Mechanical wear resistance (number of cy-
signal to the coil cles):≥10000000
ƒƒ making of systems for consumers’ control ƒƒ Number of cycles per hour: 1200 up to 32A; 600
ƒƒ used as an operating element in process control for 40-95A
panels ƒƒ Pole leaking power: up to 13W
ƒƒ remarkable with high reliability of current charac-
teristics Mounting:
ƒƒ reliable separation of power contacts ƒƒ on DIN-rail
ƒƒ secured cover of the movable part of the contactor ƒƒ with bolts to the surface
ƒƒ mounting position: vertical gradient – maximum± 5°
Technical data: ƒƒ Plastic: wear resistance of UV rays and non-flamma-
ƒƒ Rated operating voltage of the coil: from 12V DC ble (self-extinguishing material)
to 220V DC ƒƒ Ambient temperature: -10°C + 65°C
ƒƒ Rated operating voltage of the power circuit: up to ƒƒ Altitude: up to 2000m
690V DC
Overall dimensions (mm)
Type
A B C a b
LP 1 D0910 47 76 95 34/35 50/60
LP 1 D1210 47 76 95 34/35 50/60
LP 1 D1810 47 76 95 34/35 50
LP 1 D2510 57 86 101 40 50
LP 1 D3210 57 86 101 40 50
LP 1 D4011 77 129 176 40 100
CONTACTORS

LP 1 D5011 77 129 176 40 100


LP 1 D6511 77 129 176 40 100
LP 1 D9511 87 129 182 40 100
LP 1 F115 163.5 170 171 40 150
LP 1 F150 163.5 170 171 40 150
LP 1 F225 168.5 197 181 48 172

68 Rated Auxiliary Pack-


Rated capacity of the consumer (kW) Catalogue number according to the coil voltage (V DC)
Type current contact ing/Box
(А) (pcs.) 230V 400V 415V 440V 690V (pcs) 12V 24V 36V 48V 110V 230V
LP 1 D0910 9 1NO 2.20 4.00 4.00 4.00 5.50 1/40 23962 23098 23130 23971 23980 23139
Low voltage contactors- LP-1D

LP 1 D1210 12 1NO 3.00 5.50 5.50 5.50 7.50 1/40 23963 23128 23131 23972 23981 23140
LP 1 D1810 18 1NO 4.00 7.50 7.50 7.50 10.0 1/40 23964 23188 23132 23973 23982 23141
LP 1 D2510 25 1NO 5.50 11.0 11.0 11.0 15.0 1/30 23925 23258 23133 23974 23983 23142
LP 1 D3210 32 1NO 7.50 15.0 15.0 15.0 18.5 1/30 23966 23328 23134 23975 23984 23143
LP 1 D4011 40 1NO+1NC 11.0 18.5 18.5 18.5 30.0 1/10 23967 23408 23135 23976 23985 23144
LP 1 D5011 50 1NO+1NC 15.0 22.0 22.0 22.0 33.0 1/10 23968 23508 23136 23977 23986 23145
LP 1 D6511 65 1NO+1NC 18.5 30.0 30.0 30.0 37.0 1/10 23969 23658 23137 23978 23987 23146
LP 1 D9511 95 1NO+1NC 25.0 45.0 45.0 45.0 45.0 1/10 23970 23958 23138 23979 23988 23147
LP 1 F115 115 1NO 30.0 55.0 59.0 59.0 80.0 1/4 23911 23118 23914 23917 23989 23148
LP 1 F150 150 1NO 40.0 75.0 80.0 80.0 100 1/4 23912 23158 23915 23918 23990 23149
LP 1 F225 225 1NO 63.0 110 110 110 129 1/2 23913 23228 23916 23919 23994 23201