Gnode B - Conformance Testing
Gnode B - Conformance Testing
1.1 Specification:
Minimum RF requirement as Per 3GPP Doc: TS 38.104 (Base Station)/ TS 38.101-1(FR1) /TS
38.101.2 (FR2) at User Equipment.
Conformance Test: TS 38.141 -1 FR1 & TS 38.141-2 Radiating Test (FR1/FR2) both for base
Station.
1. RF Output signal form g NB is first attenuated then connect to Spectrum Analyser. (Reason:
The Maximum Output power is more than 40 dBm so to protect the instrument Attenuator
required.
2. 10 MHZ reference & Frame trigger from g NB need to connect with the Instrument.
3. Interfering Signal required for Intermodulation Test (Interfering signal got generated through
signal generator and then input to transmitter through Circulator.
4. Spectrum Analyser: Capacity to do measurements of following below:
Adjacent Channels 1. Channel Power
2. Occupied Bandwidth these two are
the Basic Measurement signal for Power /Bandwidth.
3. ACLR
Operating Band 4. OBUE
Out of band Emissions 5. Spurious Emission These 3 items for Unwanted Emission
Test but target for diff. Freq. Offset.
6. TX ON/OFF Power (Specially for TDD Signal)
7. Mod Analysis: EVM (Frequency Offset & Timing alignment
error)
8. Mod Analysis: TAE (Timing Alignment Error)
9. Mod Analysis: Frequency Error. These
three belongs to Modulation analysis that can get the g NB
demodulated with the corresponding test model and then
report various measurement result.
Test Models: it is the set of signal configuration as per 3GPP Standard for g NB Transmitter
Test.
1.3 Test Model ----Test Items: Configuration likes Cyclic Prefix /Maximum RB Number /Frame
structure /specific Channel setting. (No SSB include in the test Model Items only control
channels & Data channels).
Example:
Measured Max Power: with Full RB use & 64 QAM along with OSTP = -1.02 dBm
Minimum Power: Single RB with 64 QAM & OSTP: -26.5 dBm
So, Power Dynamic Measurement Value: 25.48 Db. :
Fig: 3GPP Test Specification about the relation b/w transmitter ON, OFF & Transient Period .
1. Verify the OFF-power level. (for <3ghz frequency power is <-83 dBm/MHz) & For FR2 (-82.5
dBm/MHz)