Electrical Fast Transients IEC 61000-4-4 Ed. 3.0 (2012-04) Level IV 3.5 mm
3. Installation to be done by skilled electrician.
Surge IEC 61000-4-5 Ed. 2.0 (2005-11) Level IV 4. Suitable dampers should be provided in the event of excessive vibrations during installation. 2
1 X 0.2 ....4 mm Rigid Wire
Conducted Susceptibility IEC 61000-4-6 Ed. 3 .0 (2008-10) Level III (Without wire protection)
5. Automation and control devices must be installed so that They are protected against any
Voltage Dips and interruptions IEC 61000-4-11 Ed. 2.0 (2004-03) For Class A 1 X 0.2 ....2.5 mm
2
risk of involuntary Actuation.
Power Frequency Magnetic Field IEC 61000-4-8 Ed. 2.0 (2009-09) Level IV (With wire protection)
6. While using the device with Star Delta Starter, configure the Full Load Motor Current as per
Voltage Flickers & Fluctuations IEC 61000-3-3 Ed. 3 .0 (2013-05) Class A
Conducted Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A
the current in Delta mode. AWG 1 X 22 to 12
Radiated Emission CISPR 14-1 Ed. 5.2 (2011-11) Class A NOTE: Product innovation being a continuous process, we
*Phase Reverse not applicable to 17A122OB0,222OB0,322OB0 & 422OB0 products. **Note: For products 15-45A range, IP protection is not applicable. reserve right to alter specifications without prior notice.
Current Monitoring Relay Series CMR
Functional Description: Overall Dimensions for Product with Terminal: Relay Connection Diagram: Connection Diagram for Single Phase
·Inverse Time:
·Overload protection: Manual Reset Auto Reset
Relay implements the thermal image of the motor during heating N
and cooling periods. If the motor current exceeds 1.11 times the
set value of the current, relay trips the motor as soon as the value
of thermal capacity exceeds threshold value.
L
N
L
N
This function can be used to check the trip of the relay. For
START / STOP
test sequence press and hold the TEST switch for 5 sec during 15
15
this time all LEDs glows ON. After relay trip ‘UNB’ LED starts L
16 GIC L
16 GIC
CMR
Blinking for Three Phase products & ‘OL’ LED ON for 1PH CMR
18
products.Press Reset switch for 2 sec. to come out of Test 18
function. N
N
Definite Time: Motor
· Overload Protection: Motor
1) Relay trips if the motor current exceeds 1.11 times set value of
the current for duration of set trip time for runtime ‘OL’ fault.
2) If ‘OL’ fault occurs at motor start up, relay trips after the
current exceeds 1.11 times of set nominal current, by taking Connection Diagram for Three Phase:
Connection for Terminal based products: Input connection between L1 & L3
start time plus trip time.
Relay out put : 15, 16, 18
· Test Function: Manual Reset Auto Reset
This function can be used to check the trip time of the relay. For test
sequence press and hold the TEST switch for 5 sec. Relay trips after MODE Selection:
completion of set values of start time and trip time. During test, ‘UL’
Two position DIP slide switch has been provided on the front facial of the product.
& ‘OL’ LED’s become ON. After relay trip, ‘OL’ LED remains ON.
By using these switches following protection / modes can be made On and OFF.
Press Reset switch for 2 sec. to come out of Test function.
1) Auto Reset mode.
NOTE:
2) Locked Rotor Protection (for Inverse Time products)
For ‘1A’ current, use 3A to 9A range product with 3-wire
3) Underload Protection mode (for Definite Time products)
turns through the Ct’s and select 3A range of nominal current. OR
L1
L1
L3
L3
For ‘1A’ current, use 2A to 5A range product with 2-wire
UL UL
turns through the Ct’s and select 2A range of nominal current. START / STOP
15 15
Lock Out: 16 GIC
L1
16 GIC
L1
In Auto Reset mode of operation Lockout feature enables to restrict AUTO Reset mode = OFF (Manual ON) AUTO Reset mode = ON CMR
CMR
number of restarts of motor per hour in case of continuous fault LOCKED Rotor Protection = OFF LOCKED Rotor Protection = ON 18 18
EXTERNAL CT INTERFACE:
In case of nominal current setting range requirement is higher than 45A,
MA = AUXILLIARY SUPPLY MC = AUXILLIARY CONTACT
then model with 2 to 5 A current range setting should be used with
external CT interface as shown in connection diagram. INVERSE TRIP CHARACTERISTIC CURVES:
Note:-Always use external CT having secondary rating 5A. Connection Diagram for External CT interface:
e.g.:-In case of external CT with ratio 100:5 is to be used then nominal 10000
current setting knob can be aligned at 40%, 50%, 60%, 70%, 80%
90% & 100% of rated primary current.
External CT with following ratios can also be used:- 50:5, 200:5.
Operating Time(Seconds)
1000
Motor
Crest Factor:
For pure sine wave, the crest factor is 1.414, hence for 8 times current, S1 S2
100
the peak value will be 1.414 X 8 X full scale RMS current.
17LL001_11
0 2 4 6 8 10 18
Multiples of Nominal Current
Warm Curve: Pre loading at 90% of load according to IEC 60255 - 08
L2/N