Infologic Manual
Infologic Manual
0 Basic Controller
Control panel
Introduction
In general, the Air Control 5.0 Basic controller has following functions:
• Controlling the compressor;
• Protecting the compressor;
• Monitoring service intervals;
• Automatic restart after voltage failure (made inactive);
Shut-down
If the compressor element outlet temperature exceeds the programmed shut-down level or the overload relay of main
motor trips, the compressor will be stopped. This will be indicated on the display of the regulator. For details see page 6.
Service warning
If the service timer exceeds the preset value, the controller advise the operator via the display, to carry out the service
maintenance. For details see page 8.
Detailed description
• Motor stopped
• Running unloaded
• Running unloaded (blinking for manual stop)
Machine control mode • Remote start /stop active
Automatic restart after
• Automatic restart after voltage failure is active
voltage failure
Active protection
• Emergency stop
functions
Service • Service required
MPa • Pressure unit (mega Pascal)
bar • Pressure unit
PSI • Pressure unit
A time / delay parameter is displayed. NOTE:
• x1000: ON if the displayed value is in thousands of
• hrs: ON if the displayed value is in hours
• s: ON if the displayed value is in sec
°C • Temperature unit
°F • Temperature unit
• Motor
• Element outlet temperature.
• Wrong rotation input is active
From Main screen is possible with up and down buttons (4-8) to change view from pressure to temperature of element
outlet.
• To switch on the compressor, press for 3 seconds (s) start/stop button (3), compressor starts and status is shown:
• To stop the compressor, push start/stop button (3), compressor running unload:
When unload time elapsed, compressor is stopped and back to main screen:
• To enter in main menu (starting from the Main screen) press for 3 seconds (s) enter button (7), main menu is shown:
Is possible to scroll in menu with up or down buttons (4-8), to select one item push enter button (7) and to go to the
previous screen or to end the current action push start/stop (3) button. For details see page 9.
• If emergency stop button is pushed, compressor stops immediately and the following screen will appear:
Emergency stop
When emergency push button is restored, to reset alarm press for 5 seconds enter button (7), than you will see <rSt> on display:
Alarm reset
Description
A shut-down warning will appear in case of:
• Too high a temperature at the outlet of the compressor element.
Compressor element outlet temperature
• If the outlet temperature of the compressor element exceeds the shut-down warning level (factory set at 110 ˚C / 230 ˚F),
warning LED (5) is on and the element temperature pictograph blinking.
• Press Scroll up or down buttons (4-8). The screen shows the temperature at the compressor element outlet.
It remains possible to enter in menu with press enter button (7) for 3s to check the actual status of other parameters. Press
button (3) to stop the compressor and wait until the compressor has stopped. The warning message will disappear as soon
as the warning condition disappears.
1.6 Shut-down
Description
The screen shows that the temperature at the outlet of the compressor element is 115 ˚C.
• When the shut-down condition has been solved, the compressor could be restarted.
Motor overload
• In case of motor overload, the compressor will be shut-down, alarm LED (5) will flash automatically and the following
screen will appear:
Description
A service warning will appear when the service timer has reached the preset time interval.
• If the service timer exceeds the programmed time interval, alarm LED (6) is blinking with a following screen:
Blinking screen
• Select <dAtA> and press Enter button (7) to enter in data menu.
• Scroll up or down buttons (4-8) to <d.6> and the service symbol is shown.
• Press enter button (7): the actual reading of the service timer appears and is shown in <hrs>
From the Main screen press for 3s enter button (7) to enter in Menu and then you will find the following items:
• Data menu: Data counters parameters
• Programming menu: Submenu of regulation pressure, Timer, Display setting and Control setting.
• Test menu: Display test.
• Info menu: Information of firmware release.
MENU
<dAtA> Data menu
<d.1> Calling up running hours
<d.2> Calling up motor starts
<d.3> Calling up module hours
<d.4> Calling up loading hours
<d.5> Calling up load solenoid valve
<d.6> Calling up service timer
The screen shows the unit used (x1000 hrs) and the value (11.25): the running hours of the compressor are
11250 hours.
This screen shows the number of motor starts (x 1 or - if <x1000> lights up - x 1000). In the above example, the number of
motor starts is 10100.
In the example shown, the screen shows the unit used (hrs) and the value (5000): the regulator module has
been in service during 5000 hours.
The screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1755>: the compressor has been running loaded
during 1755 hours.
This screen shows the number of unload to load actions (x 1 or - if <x1000> lights up - x 1000). In the above example, the
number of unload to load actions is 10100.
This screen shows the unit used <hrs> (or <x1000 hrs>) and the value <1191>. In the example shown, the compressor has
run 1191 hours since the previous service.
For reset timer contact your dealer.
• Press Scroll up or down button (4-8) to <PrSL> is shown and then press Enter button (7). Pressure band 1 (<SEL.1>) is
shown on the display. Button (4-8) can be used to scroll to pressure band 2 (<SEL.2>).
• Scroll up or down buttons (4-8) to (<LPr.1> / <uPr.1> / <LPr.2> / <uPr.2>) to select parameter to see or modify and press
enter button (7).
•The actually used pressure is shown, than scroll up or down buttons (4-8) to set pressure value and press Enter button (7)
to confirm, unit blinking and saved into memory.
Description
This function allows the compressor to restart automatically after voltage failure. The activation can be done only by your
dealer. Please contact him for further details.
In this submenu <CtrL> is possible to setting lead time of automatic restart after power failure.
• Scroll up or down buttons (4-8) to <Ar.d> is shown and press enter button (7). The actually delay time of automatic restart
after voltage failure is shown. Is possible to set delay time from 30s to 240s.
• Scroll up or down buttons (4-8) for change this value and press enter button (7) to confirm, state blinking and saved into
memory.
After any power failure, before restarting the compressor will wait for a fixed time. When delay time is running, the display
will show the related countdown value as below:
Description
Once this parameter is activated, the physical digital input can be used to switch the compressor between start and stop
Please contact your dealer for activation.
The activation of local/remote control can be only changed when compressor is stopped.
Starting from the Main screen:
• Press Enter button (7) until enter in main menu.
• Select <ProG> and press Enter button (7) to enter in data menu.
• After PASS blinking insert a code and confirm with Enter button (7).
• Scroll up or down buttons (4-8) to <CtrL> for control settings and press Enter button (7) to enter in submenu.
• Scroll up or down buttons (4-8) to <Lo.rE> is shown and press Enter button (7). The actually of remote start stop is shown.
• Scroll up or down buttons (4-8) for active/deactivate this function from <YES> or <no> and press Enter button (7) to
confirm, state blinking and saved into memory.
• After <PASS> blinking is possible insert password, for standard users is 0 and press enter buttons (7) to confirm.
Keep both UP + DOWN buttons pressed more than 3s to lock and unlock the keyboard.
• The display will show the label “LocK” blinking for 3s if the keyboard has been locked;
• The display will show the label “UnLo” blinking for 3s if the keyboard has been unlocked.
Table of contents
Introduction 1
1.1 Control panel 2
1.2 Icons used on the display 3
1.3 Main screen 4
1.4 Main function 4
1.5 Shut-down warning 6
1.6 Shut-down 6
1.7 Service warning 8
1.8 Scrolling through all screens 9
1.9 Calling up running hours 10
1.10 Calling up motor starts 10
1.11 Calling up module hours 10
1.12 Calling up loading hours 11
1.13 Calling up load relay 11
1.14 Calling up/resetting the service timer 12
1.15 Calling up/modifying pressure band selection 12
1.16 Calling up modifying pressure band settings 13
1.17 Calling up modifying Number of hourly compressor Activation 13
1.18 Calling up modifying the unit of temperature 13
1.19 Calling up modifying the unit of pressure 14
1.20 Calling up modifying time backlight 14
1.21 Activating automatic restart after voltage failure 14
1.22 Activating Local / remote start/stop 15
1.23 Calling up Maintenance warning 15
1.24 Activating password protection 16
1.25 Keyboard Lock 16