Rebitadora Rivit Riv938Manual
Rebitadora Rivit Riv938Manual
PULL-TO-PRESSURE TOOL
FOR RIVET NUTS FROM #4-40 TO 3/8” AND M3 TO M10
AND RIVET STUDS #8-32 TO 5/16” AND M4 TO M8
OPERATING INSTRUCTIONS
Instruction Manual - RIV938
2 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
PennEngineering • www.pemnet.com 3
Instruction Manual - RIV938
PROTECTIVE WING
(optional accessory)
Together with the rubber base, it creates a support for the tool, avoiding any contact of the surface with
the metal part of the tool body.
4 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
GENERAL INFORMATION
MANUFACTURER
Rivit S.r.l. was born in 1973, it produces and distributes in Fasteners and Tools for Fixings (tools for rivets and rivet
nuts). The Company boasts much technical experience and offers a wide range of products related to fastening
systems.
ASSISTANCE
In case you need any assistance concerning the use and the maintenance of the tool, or in case you need to order
any spare parts, you shall contact your local authorised dealer (or Rivit S.r.l. directly) specifying the identification/
serial numbers of the tool, written on its outer casing.
WARRANTY
The warranty has a validity of 12 months, as of the date indicated on the invoice.
The warranty only covers replaced parts; labor is not included.
The following are not covered by warranty: standard accessories (see section 2.5) and tool damages caused by:
• transport and/or handling, user’s mistakes,
• failed servicing/maintenance, as indicated in section 7 of this manual,
• faults and/or breakages that are not attributable to tool anomalies,
• normal consumption of consumables.
The warranty is invalidated both in case of unauthorized tampering/replacements of tool components and in case of
use of accessories, tools or consumables different to those recommended by the manufacturer, which could even
cause injuries to the tool’s user.
Rivit S.r.l. assumes responsibilities only if the tool is originally defective, but declines all forms of responsibility if
the user fails to follow the instructions given.
OPERATING SYSTEM
The hydro-pneumatic RIV938 tool, with oil pressure regulation, is designed to place female threaded inserts (from
#4-40 to 3/8” and M3 to M10) and male threaded inserts (from #8-32 to 5/16” and M4 to M8). The hydro-pneumatic
system and the mechanical components used inside the RIV938, when compared with other riveting tools, are more
reliable. There is less wear and tear of the components, consequently the tool will last much longer and work better.
The technical solutions adopted make the RIV938 more compact and lighter.
MANUAL STRUCTURE
This instruction manual must be read with particular attention by the Customer, as the correct pre-arrangement,
installation and use of the tool, are the correct basis for a good relationship between Manufacturer and Customer.
PennEngineering • www.pemnet.com 5
Instruction Manual - RIV938
RECEIVERS
The manual herein has been written for both the operators and the technicians enabled to service the tool.
Operators must not carry out jobs reserved to service and/or qualified technicians.
Rivit S.r.l. is not liable for any damage deriving from the failed observance of this rule.
OPERATING SYSTEM
The hydro-pneumatic RIV938 tool, with oil pressure regulation, is designed to place the following fasteners:
• Female threaded rivet nuts (from #4-40 to 3/8” and M3 to M10)
• Male threaded rivet studs (from #8-32 to 5/16” and M4 to M8)
The hydro-pneumatic system and the mechanical components used in the inside structure of the RIV938, when
compared with other riveting tools, result to be much more reliable. A tool feature is a reduction of the problems
caused by the wear and tear of the components, and consequently the tool will last much longer and work better.
The technical solutions adopted make the RIV938 more compact and lighter: the result is a very handy tool.
VIBRATION
When used correctly, the tool does not produce any dangerous vibration.
NOISE LEVEL
The tool is designed and manufactured in such a way that the noise level is very low. The weighed equivalent continu-
ous acoustic pressure level A in the operator position is indeed below 80 dB (A).
This information can allow the tool user to better evaluate the possible risks of danger.
TECHNICAL DATA
The following table provides the technical data and features of the tool, to which you must refer when contacting the
ATLAS® Technical Assistance Department at PennEngineering.
6 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
PennEngineering • www.pemnet.com 7
Instruction Manual - RIV938
OPTIONAL TOOLING
For Blind Threaded Insert Installation.
8 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
PennEngineering • www.pemnet.com 9
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
10 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
PennEngineering • www.pemnet.com 11
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
12 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
PennEngineering • www.pemnet.com 13
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
14 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
3 4
PennEngineering • www.pemnet.com 15
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
16 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
PennEngineering • www.pemnet.com 17
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
18 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
PennEngineering • www.pemnet.com 19
Instruction Manual - RIV938
KIT COMPOSITION
4 5
3
2
20 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
3 4
PennEngineering • www.pemnet.com 21
Instruction Manual - RIV938
OPTIONAL TOOLING
For Blind Threaded Stud Installation.
Kits are sold separately. A different kit is required for each thread size.
22 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
2 3 4
PennEngineering • www.pemnet.com 23
Instruction Manual - RIV938
KIT COMPOSITION
2 3 4
24 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
2 3 4
PennEngineering • www.pemnet.com 25
Instruction Manual - RIV938
KIT COMPOSITION
2 3 4 5
26 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
3 4
PennEngineering • www.pemnet.com 27
Instruction Manual - RIV938
KIT COMPOSITION
3 4
28 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
KIT COMPOSITION
3 4
PennEngineering • www.pemnet.com 29
Instruction Manual - RIV938
KIT COMPOSITION
3 4 5
30 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
PennEngineering • www.pemnet.com 31
Instruction Manual - RIV938
SPARE PARTS
32 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
REF. PART NUMBER QTY DESCRIPTION REF. PART NUMBER QTY DESCRIPTION
1 4153100 1 HANDLE CASING 21 3235600 1 O-RING
3 4172400 1 TOOTHED BLOCKING RING NUT M3-M10 23 4177400 1 GASKET KIT (3 PIECES)
6 4151500 1 ROTATING PIN AND SKIMMER 26 4151000 1 PISTON GASKET KIT (2 PIECES)
7 3093200 1 SNAP RING 28 4175600 1 AIR HOSES KIT WITH O-RING (6 PIECES)
PennEngineering • www.pemnet.com 33
Instruction Manual - RIV938
Hole Ø 8 4
34 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
REF. PART NUMBER QTY DESCRIPTION REF. PART NUMBER QTY DESCRIPTION
1 3763400 1 PLANET WHEEL HOLDER 8 3327300 1 BEARING
2 3763300 1 BEARING 9 3327400 1 REAR PLATE
3 3763200 1 PLANET WHEEL 10 3327000 1 STATOR
4 3327500 1 BEARING 11 3326900 1 FRONT PLATE
5 3523400 1 ROTOR 12 3763700 1 SPACER
6 3327100 1 FIN 13 3763600 1 CROWN WHEEL
7 3327200 1 ROLLER 14 3763500 1 SNAP RING
NOTE: When placing an order, always reference the part number and the description.
Only local authorized dealers are allowed to repair the tool. Otherwise, contact the ATLAS® Technical Assistance
Department of PennEngineering, where qualified engineers can help to solve any problems.
PennEngineering • www.pemnet.com 35
Instruction Manual - RIV938
GENERAL WARNINGS
The operator must read carefully the information given in the present manual, especially with regard to the safety
precautions listed in this chapter. The operator must also observe the warnings listed below:
INTENDED USE
The tool is designed exclusively to be used with female threaded type inserts with thread sizes #4-40 to 3/8” / M3 to
M10 and male threaded type studs #8-32 to 5/16” / M4 to M8.
UNINTENDED USE
The tool shall not be used:
• In explosive or aggressive atmosphere or when there is an excessive amount of dust or oil in the air.
• In atmosphere subject to the risk of fire.
• When it is exposed to weather conditions.
RESIDUE RISK
During the normal working cycle and when servicing the tool, the operators are exposed to some residue risks
which, due to the nature of the operations to be carried out, cannot be totally eliminated.
It is therefore absolutely crucial not to exceed the maximum pressure indicated in the technical data section on
page 6.
36 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
IDENTIFICATION/SERIAL NUMBER
HANDLING
The tool can be hand carried. It is recommended to store the tool in its case after using it.
The tool can be transported safely if is has been correctly put away in its case.
Damages to the tool caused during transport and/or handling are not covered by WARRANTY.
Repairs or replacements of damaged parts are at Customer’s charge.
STORAGE
If you are not going to use the tool for a long time, you must put it away according to the following suggestions:
• Store the tool indoors.
• Protect the tool from impacts and stresses by keeping it in its case.
• Protect the tool from damp and excessive heat.
• Keep the tool away from corrosive substances.
CONNECTIONS
To avoid problems when starting the tool, observe the following:
PNEUMATIC
The pneumatic line is connected by a quick-release coupling hose to be attached to the air connection, thread size
1/4”, supplied with the tool. The air supply hose must be flexible and must meet the safety requirements of the tool.
AIR SUPPLY
The air supply line must be free from dirt and moisture to prevent early wear of moving components on the tool.
Therefore, it is recommended to use dry air: i.e. not greased.
PRELIMINARY CHECKS
Before putting the tool into service you need to make a few inspections and checks in order to prevent errors or
accidents while starting it.
• Check if the tool has been damaged during transportation.
• Check if the compressed air hose is accurately connected to the air supply line.
• Check if the tool turns freely and if the motor runs freely.
PennEngineering • www.pemnet.com 37
Instruction Manual - RIV938
OPERATORS
The tool is designed to be used by one operator only.
Tool operators must satisfy the requirements stated hereafter (or they must be informed and trained accordingly).
They must be aware of the manual herein and of all information relevant to safety:
• They must have some general and technical education, to a sufficient level to be able to understand the manual
and to interpret the drawings and the diagrams correctly.
• They must be acquainted with the safety rules, and with the industrial-safety and technical instructions.
• They must have an overall knowledge of the line and of the factory in which the tool is installed.
• They must know how to act in case of emergency, where to find the individual protection means and how to use
them correctly.
Together with the above-mentioned requirements, the service technicians must also have appropriate technical
training.
38 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
Warning: Tool setting and screw replacement must be carried out with the tool disconnected from the air supply
line.
Ø 1.02” / 2.76” /
26 mm 70 mm
Simultaneously press
the two pins sliding
them into the hole and
unscrew the ring.
PennEngineering • www.pemnet.com 39
Instruction Manual - RIV938
WARNING!!!
Pressure (force) must
always be regulated as
Yellow per maximum thickenss
White Orange
40 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
INFORMATION
To be used in case the rivet nut gets stuck, or in case you decide that the inserted rivet nut is not the correct one
and you have to change it.
AIR DISTRIBUTOR
WARNING
The cycle of unscrewing may not occur when the rivet nut is not mounted on the screw (tie rod) or the manostat
isn’t under pressure. The manostat can not unscrew if the tool is not under pressure.
PennEngineering • www.pemnet.com 41
Instruction Manual - RIV938
42 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
MAINTENANCE
Maintenance operations must be carried out with the tool stopped and disconnected from the pneumatic supply line.
Warnings:
• The tool maintenance instructions must be followed carefully.
• To ensure safety and perfect tool efficiency, it is recommended to use exclusively ORIGINAL spare parts.
CLEANING
It is a good rule to completely clean and grease the tool on a periodic basis (depending on the type and frequency of
use). These operations must be carried out at least once a year.
Shut-off all sources of power to the tool.
The operator must wear and use suitable personal protections before starting to clean the tool.
ORDINARY MAINTENANCE
In order to prevent stoppages and faults of the tool, an ordinary maintenance (including inspections, checks and
operations) must be scheduled to keep the following under systematic control:
• State of lubrication of the tool.
• State of wear of consumable parts.
PennEngineering • www.pemnet.com 43
Instruction Manual - RIV938
CAUSE SOLUTION
When inserting the rivet nut in the tie Not enough oil in tool. Check the O-ring (B) and replace it.
rod, after pressing the trigger, tool
does not unscrew properly.
44 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
CAUSE SOLUTION
Motor screwing When the rotating pin (6 part number 4151500) is broken and you
replace it, the motor may rotate continuously, which means that the
shaft (13 part number 3761300)
is too long; in this case it will have
to be shortened by a few tenths to
obtain the closure of the ball (14
part number 3096900).
Unlike the situation above, the shaft is too short and it has to be
replaced with a new one, fitting it without end float, with the air on,
in order to obtain the closure of the ball (14 part number 3096900).
Loss of revolutions during When you are working intensely there is likely to be a loss of
unscrewing revolutions in the unscrewing; it is necessary to remove the air hose
and add a few drops of oil in the air hose connection (Ref. 34) and
re-enter the air by turning the
engine with button (P) for a
couple of minutes.
PennEngineering • www.pemnet.com 45
Instruction Manual - RIV938
REPAIRS
To ensure the operational efficiency and safety of the tool, all repair jobs shall be carried out exclusively by the local
authorized dealer or by the Technical Assistance Service of PennEngineering.
REQUESTING ASSISTANCE
For any information concerning Use, Maintenance, Installation, Repair etc., PennEngineering is at the Customer’s
full disposal for all enquiries.
When making inquiries, the customer is requested to be absolutely clear and to always refer to this Manual.
DISMANTLING INSTRUCTIONS
DISMANTLING INSTRUCTIONS
When disposing the tool you need to separate the plastic parts, which are to be disposed of in compliance with
current Regulations.
As for the bulk metal part of the tool, simply split-up the steel parts from those in other metals or alloys and send to
be melted down and recycled.
The oil drained from the tool must not be thrown outdoors but handed over to an authorized oil disposal center.
46 PennEngineering • www.pemnet.com
Instruction Manual - RIV938
PennEngineering • www.pemnet.com 47
Instruction Manual - RIV938