For efficient air movement, look no further than Greenheck’s AER direct drive and BAER belt drive
sidewall fan offering! With up to 30% higher maximum airflow compared to existing options, the two
models serve all of your clean air application needs. Constructed from corrosion-resistant galvanized
steel and incorporating high efficiency fabricated steel and cast aluminum airfoil propellers, the AER
and BAER outclass the competition. Package with any of our standard sidewall options or accessories
for all of your wall-mounted fan needs!
n Direct drive sizes from n Direct drive up to n Horizontal or vertical n Clean air applications
20 - 60 78,600 cfm n Wall housing n Industrial environments
n Belt drive sizes from n Direct drive up to 3.4 in.
n Wall collar n Factories
24 - 36 wg of static pressure
n Warehouses
n Belt drive up to
33,000 cfm n Data centers/data
management
n Belt drive up to 3.3 in.
wg of static pressure n Mission critical
2
Standard Construction
3
Dimensions
BC C
B B B
C
L C C
L C
L
L
A A C
L C
L
C C C C
C C
A A LA
C C
L A C
L C
L
C C C C
E E
A A D D C
L C
L
Exhaust
Exhaust
E E E E
A A D D A A D D
ExhaustExhaust Exhaust Exhaust
B B
C
L C
L
BC C
B
C
L C
L
A A C
L C
L
C C
C C
A A C
L C
L
C C E E
A A D D
Supply
E Supply
E
A A D D
Supply Supply
Direct To Wall
Fan D E Damper Approx.
A B C Recommended
Size Max. Max. Size Fan Weight*
Wall Opening Sq.
AER Direct Drive
20 26.03 4.00 9.02 20.48 16.50 23.2 22 x 22 190
24 32.10 4.00 12.05 22.88 18.50 26.10 26 x 26 295
30 38.10 5.00 14.05 23.14 18.25 32.10 32 x 32 305
36 44.10 5.00 17.05 27.06 18.13 38.10 38 x 38 410
42 50.14 5.00 13.38 28.95 22.88 44.14 44 x 44 640
48 56.10 5.00 14.38 29.26 22.25 42.00 50 x 50 650
54 62.00 5.38 12.81 8.60 3.13 56.00 56 x 56 840
60 68.00 5.38 11.45 8.60 2.13 62.00 62 x 62 880
BAER Belt Drive
24 32.10 4.00 12.05 21.50 20.75 26.10 26 x 26 307
30 38.10 5.00 14.05 26.00 25.25 32.10 32 x 32 323
36 44.10 5.00 17.05 28.00 27.25 38.10 38 x 38 436
All dimensions in inches and weight is shown in pounds, does not include accessories. *Varies with motor selection.
4
Performance
AER Direct Drive
AER-20 Performance
AER-20
Coverage
Performance Coverage AER-24 Performance
AER-24
Coverage
Performance Coverage
3.00 3.00 4.00 4.00
3.50 3.50
2.50 2.50
3.00 3.00
Static Pressure [in wg]
1.50 1.50
1.00 1.00
1.00 1.00
0.50 0.50
0.50 0.50
3.00 3.00
2.00 2.00
2.50 2.50
Static Pressure [in wg]
1.50 1.50
1.00 1.00
1.00 1.00
0.50 0.50
0.50 0.50
AER-42
AER-42 Performance Performance Coverage
Coverage AER-48 Performance
AER-48
Coverage
Performance Coverage
2.5 2.5 2.0 2.0
1.8 1.8
1.4 1.4
Static Pressure [in wg]
1.0 1.0
0.6 0.6
0.2 0.2
5
Performance
AER Direct Drive
AER-54 Performance Coverage
AER-54 Performance Coverage AER-60 Performance
AER-60
Coverage
Performance Coverage
2.5 2.5 2.5 2.5
6
Performance
BAER Belt Drive
BAER-24 Performance
BAER-24
Coverage
Performance Coverage BAER-30 Performance
BAER-30
Coverage
Performance Coverage
3.0 3.0 4.0 4.0
3.5 3.5
2.5 2.5
3.0 3.0
Static Pressure [in wg]
1.5 1.5
1.0 1.0
1.0 1.0
0.5 0.5
0.5 0.5
BAER-36 Performance Coverage Fan Motor HP Fan RPM CFM Max. Static
3.5
Size Max. Max. Max. Pressure in. wg
3.0
Cast Aluminum Airfoil Prop
2.5 24 2 1750 10,800 2.60
Static Pressure [in wg]
1.0
0.5
0.0
0 5000 10000 15000 20000 25000 30000 35000
Volume [cfm]
Cast Aluminum
7
Options and Accessories
Disconnect Switches
Toggle-type and heavy-duty disconnect
switches are available for positive
electrical shutoff and safety in servicing fans.
Wall
Options include aluminum construction, insect INTERIOR EXTERIOR
for field installation to
screen and painted finish. Shipped unassembled in close off the interior wall
kit form for field assembly. Cannot be used with the opening for a finished
damper guard option. (More details on page 10.) appearance. Shipped in
crate unattached.
Wall Collar with Guard Combo
Wall collar with guard combo offers a method for Filtered Housing
mounting sidewall propeller fans while leaving the Filtered wall housings allow for a wide range of
motor and fan protected. Standard construction is of mounting arrangements to meet specific
galvanized steel (painted steel is optional) with heavy- applications. Constructed of galvanized steel with
Wall
gauge mounting flanges and prepunched mounting heavy-gauge mounting flanges and prepunched
holes. (More details on page 11.) mounting holes. Fan filters are permanent 2-inch
washable aluminum filters which can be accessed
OSHA Motor Side Guard through a bolted panel for easy removal and
cleaning. (More details on page 14.)
Protective guards of expanded metal screen in
structural steel frames are available to completely
enclose the motor and drive side of the fan. (More
Damper Guard
details on page 12.) Meets the OSHA requirements to completely enclose
the damper or wall openings on the discharge side
Wall Collar of the fan. Constructed of expanded galvanized steel
screen in galvanized steel frames. Mounting flanges
Wall collars offer a method for mounting sidewall
have prepunched mounting holes. Options include
propeller fans while leaving the motor and fan frame
aluminum construction and painted finish. The
exposed for easier access to the motor and fan
damper guard cannot be used with the weatherhood
propeller. Standard construction is of galvanized steel
option. (More details on page 15.)
(painted steel is optional) with heavy-gauge mounting
flanges and prepunched mounting holes. (More
Dampers
details on page 13.)
Used in a stand-alone manner or in conjunction
with the wall housing or wall collar, a complete
line of dampers are available for exhaust or supply
configurations. (More details on page 16.)
9
Weatherhood Kit
Weatherhoods shield wall openings and dampers from rain and snow. Construction is of galvanized steel
or optional aluminum. Standard with wire mesh birdscreen and optional insect screen. Available in 45 or
90 degree turndown. Shipped knocked-down and loose from the factory. Available with decorative or
45 Degree Weatherhood
protective Side
coatings. 45 Degree Weatherhood Front
B A
B A
C
90 Degree Weatherhood Side 90 Degree Weatherhood Front
90°90KIT
Degree Weatherhood Side 90 Degree Weatherhood Front
F
D G
D G
Fan
A Sq. B C D E F G Gauge
Size
20 25.00 23.63 25.00 24.38 30.88 25.13 25.63 18
24 32.00 30.50 27.25 31.13 36.75 31.88 32.50 18
30 37.88 36.50 29.38 37.38 41.00 37.88 38.75 18
36 43.88 42.50 33.38 43.38 46.38 43.88 44.63 18
42 49.88 48.50 36.00 49.25 50.25 49.88 50.63 18
48 56.13 54.75 40.75 55.50 56.75 56.00 57.00 18
54 62.25 61.00 44.88 62.00 62.63 62.25 63.38 16
60 68.38 67.00 48.00 68.50 68.00 68.38 69.88 16
All dimensions in inches.
10
Wall Collar With Guard Combo
Wall collar with guard combo offers a method for mounting sidewall propeller fans while leaving the motor
and fan protected. Removable screens allow easier maintenance access to the fan without having to remove
the entire guard. Standard construction is of galvanized steel (painted steel is optional) with heavy-gauge
mounting flanges and prepunched mounting holes. Factory installed to fan.
SIZES 20-48
0.63 in.
0.63 in.
A B
A B
C B
D
C B
D
1.63 in.
SIZES 54 AND 60
1.63 in.
A B
A B
C
D
C
D
Fan C D Recommended
A Sq. B Sq. Gauge
Size Supply Exhaust Supply Exhaust Wall Opening Sq.
20 26.33 32.08 32.42 32.42 33.05 33.05 27.33 18
24 32.40 38.15 43.48 43.48 44.11 44.11 33.40 18
30 38.40 44.15 46.75 46.75 47.37 47.37 39.40 18
36 44.40 50.15 52.00 52.00 52.62 52.62 45.40 18
42 50.43 56.18 54.00 54.00 54.62 54.62 52.58 18
48 56.40 62.15 55.49 55.49 56.11 56.11 57.40 18
54 62.38 68.13 62.25 57.13 63.75 58.63 63.38 16
60 68.38 74.38 62.38 57.38 63.88 58.88 69.38 16
All dimensions in inches.
11
OSHA MSG 20-48
A
A
A
B
B A
A
C B A
C
C
SIZE 54 OSHA
OSHA MSG
MSG 54
54 SIZE 60 OSHA MSG 60
A
A A
B
B A
A
B
C
C A
C
OSHA
OSHA MSG
MSG 60
60
Fan B C
A Sq. Gauge
Size Supply Exhaust Supply Exhaust
20 26.33 22.70 22.70 27.58 27.58 18
24 32.40 23.63 23.63 33.65 33.65 18
A
A 30 38.40 26.75 26.75 39.65 39.65 18
36 44.40 32.33 32.33 45.65 45.65 18
42 50.43 34.38 34.38 51.68 51.68 18
48 56.40 35.87 35.87 57.65 57.65 18
B
B
54 62.38 39.00 A
A
34.00 40.50 35.50 16
C
C
60 68.38 39.00 34.00 40.50 35.50 16
All dimensions in inches.
12
Wall Collar and Wall Housing
WALL COLLAR
The wall collar provides an easy way to mount the sidewall propeller
fan and its accessories. Standard construction is of galvanized steel
(painted steel is optional) with heavy-gauge mounting flanges and
prepunched mounting holes. Factory installed to fan. Available with
decorative or protective coatings.
Fan Recommended
A Sq. B C Gauge
Size Wall Opening Sq.
20 26.33 32.08 21.22 27.33 18
24 32.40 38.15 21.35 33.40 18
30 38.40 44.15 21.35 39.40 18
36 44.40 50.15 21.67 45.40 18 A B
42 50.43 56.18 21.72 51.43 18
48 56.40 62.15 21.72 57.40 18
54 62.38 68.13 22.88 63.38 16
60 68.38 74.38 23.13 69.38 16 C
B
All dimensions in inches.
WALL HOUSING
A wall housing allows for a wide range of mounting arrangements to meet specific applications. It is
constructed of galvanized steel (painted steel optional) with heavy-gauge mounting flanges and prepunched
mounting holes. Protective guards completely protect the drive side of the wall housing. Factory installed to
fan, reference pages 18 and 19 for installation options offered. Available with decorative or protective coatings.
Wall
FRONT
housing guards that meet OSHA requirements are also available.
LONG SIDE SHORT SIDE
LONG HOUSING SHORT HOUSING
0.63 in. 0.63 in.
A B
B D C
E F
Fan Recommended
A Sq. B C D E F Gauge
Size Wall Opening Sq.
20 26.33 31.98 32.43 38.43 39.06 33.06 27.33 18
24 32.40 38.15 37.30 43.30 43.93 37.93 33.40 18
30 38.40 44.15 38.24 45.24 45.87 38.87 39.40 18
36 44.40 50.15 39.24 46.24 46.87 39.87 45.40 18
42 50.43 56.18 43.97 48.24 48.87 44.59 51.43 18
48 56.40 62.15 43.70 51.97 52.59 44.32 57.40 18
54 62.38 68.38 52.00 58.00 58.63 52.63 63.38 18
60 68.38 74.38 54.00 60.00 60.63 54.63 69.38 18
All dimensions in inches.
13
Filtered Housing
A B
C
D
Fan Recommended
A Sq. B C D Gauge
Size Wall Opening Sq.
24 32.63 38.50 63.50 64.13 33.40 18
30 38.63 44.50 65.38 66.00 39.40 18
36 44.63 50.50 67.75 68.38 45.40 18
42 50.63 56.50 73.38 74.00 51.43 18
48 56.63 62.50 73.50 74.13 57.40 18
54 62.63 70.88 80.50 81.13 63.38 18
All dimensions in inches.
Replacement 2-inch
washable filter
14
Damper Guard
Meets the OSHA requirements to completely enclose the damper or wall openings on the discharge side of
the fan. Constructed of expanded galvanized steel screen in galvanized steel frames. Mounting flanges have
prepunched mounting holes. Options include aluminum construction and painted finish. Factory installed to
fan with wall housing and wall collar. Shipped in crate unattached with stand-alone fan. The damper guard
cannot be used with the weatherhood option.
Sizes 42&48 Sizes 54&60
Sizes 20-36
SIZES 20-36
C A
C
A B
A
A
Fan
A Sq. B C Gauge
Size
20 25.00 6.63 22.38 18
24 29.00 6.38 26.38 18
30 34.88 6.63 32.38 18
36 40.88 6.88 38.38 18
42 46.88 10.00 44.38 18
48 52.88 9.13 50.38 18
54 58.88 7.63 56.38 18
60 64.88 7.38 62.38 18
All dimensions in inches.
15
Damper Options
BACKDRAFT DAMPERS
Used as a stand-alone accessory or in conjunction
with a wall housing or wall collar accessory,
backdraft dampers are available for exhaust or
supply configurations. Backdraft dampers are
constructed with aluminum or galvanized frames
and blades and vinyl blade seals. Actuators are
available in 24, 115, 208, 230, or 460 volts.
Actuators for 50 cycle voltages are also available.
Backdraft damper model availability will be limited EM-31 Series
if fan velocity exceeds maximum damper catalog
WD-320/430 Series
velocity.
Damper
EM-31 VCD-20 VCD-23 VCD-33 VCD-34 VCD-42 VCD-43 WD-320 WD-430
Availability
Exhaust
Supply
Ship Loose Only Factory Attached or Ship Loose
TYPICAL INSTALLATION
24 26 x 26 13 26.1
MINIMUM DISTANCES DETERMINED BY MAXIMUM
30 32 x 32 13 32.1 CATALOG DAMPER VELOCITY LIMITS
36 38 x 38 14 38.1
42 44 x 44 15 44.14
MINIMUM
48 50 x 50 16 42 WALL
DISTANCE
54 56 x 56 17 56 OPENING
60 62 x 62 19 62
Damper size is nominal. All dimensions in inches.
WALL OPENING IS MINIMUM REQUIRED DIMENSION TO
Wall housing length increases by 6 inches when an ALLOW THE FAN VENTURI TO FIT INTO THE WALL OPENING
actuated damper or heavy-duty backdraft damper is
selected.
Backdraft damper availability will be limited by
maximum catalog velocity and maximum fan motor
power rating of 5 hp.
16
Vari-Green® Options
Model AER (direct drive) is available with Greenheck’s Vari-Green® technology. Greenheck’s Vari-Green
products are designed for efficiency, controllability and low maintenance.
MOTORS
The Greenheck Vari-Green motor is an electronically commutated
(EC) motor that operates on single or three phase AC power
input and internally converts it to DC power providing better
speed control capabilities (up to an 80% turndown) and higher
efficiencies than standard motors. The Vari-Green motor
blends technology, controllability and energy efficiency in a low
maintenance package that has changed the way the industry
designs, specifies and operates air movement equipment.
Depending on power rating, Vari-Green motors are available
in both single and three phase with either a dial-mounted
potentiometer (speed control) or wired to accept a 0-10 VDC
control signal from an external source.
CONTROLS
For expanded controllability, Greenheck offers many different
solutions to fit any need. Controls are designed specifically for
Vari-Green motors. These controls are available for applications
requiring manual operation or demand-controlled ventilation
(DCV). Applications utilizing DCV controls provide only the desired
amount of ventilation, delivering building owners savings on their
energy bills.
Manual Controls
• Dial-on Motor
• Remote Dial
• Touch Remote
17
Mounting Options
Sidewall propeller housings can be oriented in 1. Will the fan and housing be placed inside the
eight horizontal and eight vertical configurations. building or outside of the building?
The two main considerations for determining which 2. How will the motor and drives be most easily
orientation the project requires are: accessed, from inside of the building or from
outside of the building?
MOTOR
MOTOR ACCESSED FROM ACCESSED
BUILDING INTERIOR FROM
BUILDING
EXTERIOR
MOTOR
MOTOR ACCESSED FROM ACCESSED
BUILDING INTERIOR FROM
BUILDING
EXTERIOR
Wall housing or wall collar should be tipped
slightly to the outside for water drainage.
18
Mounting Options
Flush Interior: The fan and housing will Motor Access: The motor and drives can be placed on
be outside the building and the end of the either side of the propeller for access to grease bearings,
housing will be flush with the interior wall. check or change belts and inspect the motor/wiring
Flush Exterior: The fan and housing will be connections. Failure to assess the best access point can
inside the building and the end of the housing place maintenance personnel in extreme danger if they
will be flush with the exterior wall. must reach through the propeller.
MOTOR
ACCESSED MOTOR ACCESSED FROM
FROM BUILDING EXTERIOR
BUILDING
INTERIOR
MOTOR
ACCESSED MOTOR ACCESSED FROM
FROM BUILDING EXTERIOR
BUILDING
INTERIOR
19
Model Nomenclature
AER - 24 - 03 - 0625 - VG
Drive Type
AER = Direct Drive Direct Drive Only
Number of Blades
Propeller Blade Material
3, 6, 9, 12
02 = Fabricated Steel
03 = Cast Aluminum
The QD program has more than 1000 of the most in-demand products in stock, ready to
ship. Some products require specific customization to meet the demands of a project, The
QB program offers an even larger assortment of configure-to-order products built just for
you, in the time frame you need!
Greenheck’s Quick Build (QB) program ensures these products can be manufactured as
needed in 1, 3, 5, 10, 15, and 25-day manufacturing cycles.
Our Commitment
As a result of our commitment to continuous improvement, Greenheck reserves the right to change
specifications without notice.
Product warranties can be found online at Greenheck.com, either on the specific product page or in the
literature section of the website at Greenheck.com/Resources/Library/Literature.
00.F&V.1030 R1 3-2023
P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com Copyright © 2023 Greenheck Fan Corp.