0% found this document useful (0 votes)
49 views10 pages

Datasheet RPE3-06 Ha4010 EN 01

This document provides specifications for a solenoid-operated directional control valve. The valve is a 4-way valve in size D06 with a maximum pressure of 350 bar and flow of 80 L/min. It uses a 4-land spool design and can be operated with push button manual override if solenoids fail.

Uploaded by

angel silva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views10 pages

Datasheet RPE3-06 Ha4010 EN 01

This document provides specifications for a solenoid-operated directional control valve. The valve is a 4-way valve in size D06 with a maximum pressure of 350 bar and flow of 80 L/min. It uses a 4-land spool design and can be operated with push button manual override if solenoids fail.

Uploaded by

angel silva
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

HA 4010

Directional Control Valves


Solenoid Operated RPE3-06 11/2011
Replaces
Size D 06 (03) ·350 bar (5076 PSI) · 80 L/min(21 GPM) HA 4010 12/2009
Size D 06 (03) • pmax 320 bar (4641PSI) according to CSA 80 L/min(21 GPM)

q 4/3-, 4/2- way directional control valves

q Solenoids can be turned around their axis


to any position

q Four-land spool - reduced functional dependence


on fluid viscosity

q Push button manual override

q Installation dimensions to DIN 24 340 /


ISO 4401 / CETOP RP121-H

q Subplates see data sheet HA 0002

q CSA Upon request

Functional Description
The RPE3 directional control valves consist of housing are integrated in the DIN connector socket as part of the
(1), a control spool (5) with two centering springs (4) and solenoid. The connectors (6, 7) can be turned by 90°. By
cylindrical operating solenoids (2, 3). loosening the nut (8), the solenoids can be turned or
The three-position directional control valves are fitted replaced without interfering with any seals of the valve.
with two solenoids and two springs. Two-position In the case of solenoid malfunction or power failure, the
directional control valves have either one solenoid and spool of the valve can be shifted by manual override (9),
one return spring or two solenoids and a detent provided the pressure in T-port does not exceed 25 bar.
assembly. The valve housing (1) is phosphate coated and the
The operating solenoids are DC solenoids. For AC solenoids (2, 3) are zinc coated.
supply the solenoids are provided with a rectifiers which

‰ˆ‚† ‡ƒˆ‰
„ „
A B

a A B b

1
HA 4010
Ordering Code

RPE3-06 /

Directional Control
Valves Solenoid
Operated
Sensing of the end position
no designation without sensor
S1 normally-open sensor to 50 bar
Valve size (725PSI)
S2 normally-open sensor to 210bar
(3045 PSI)
S4 normally-closed sensor to 50bar
(725 PSI)
Number of valve positions
two positions 2 Seals
three positions 3 no designation NBR
V FPM (Viton)

Spool symbols Orifice in P port


see the table spool symbols no designation without orifice
D1 Æ1.0 mm (0.039 inch)
D2 Æ1.5 mm (0.059 inch)
Rated supply voltage of solenoids D3 Æ2.0 mm (0.079 inch)
(at the coil terminals) D4 Æ2.2 mm (0.087 inch)
12 V DC / 2.72 A 01200 D5 Æ2.5 mm (0.098 inch)
24 V DC / 1.29 A 02400
205 V DC / 0.15 A 20500
230 V AC / 0.17 A / 50 (60) Hz 23050
The AC coils correspond with E5 type Soft Shift -
Spool speed control orifice
CSA Upon request
no designation without damping
T1 orifice Æ 0.7 mm (0.03 inch) in solenoid

Type of solenoid coil


with terminal for the connector, EN 1745301-803 E1
with integrated quenching diode and terminal E2
for the connector, EN 1745301-803
with AMP-Junior-Timer-connector E3A
with integrated quenching diode and terminal E4A Manual overide
for AMP-Junior-Timer connector
no designation Standard
with integrated rectifier and terminal E5 N1 covered with retaining nut
for the connector, EN 1745301-803
N2 covered with rubber boot
Other coils on demand see catalog HA8007 N3 with detent assembly

Note: Connector of the position sensor is not supplied


(see ordering number on page 10)

FOR PREFERRED TYPES SEE BOLD TYPING IN ORDERING CODE, FUNCTIONAL SYMBOLS
AND TABLE OF PREFERRED TYPES ON PAGE 10

2
HA 4010
Technical Data
Valve size mm (US) D 06 (03)
Maximum flow L/min (GPM) see p-Q characteristics
Max. operating pressure at porte P, A, B bar (PSI) standard 350 (5076), according to CSA 320 bar (4641PSI)
50 (725) for version S1, S4
Max. operating pressure at port T bar (PSI)
and 210 (3000) for version S2
Pressure drop bar (PSI) see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range for NBR seals °C (°F) -30 ... +80 (-22 ... +176)
Fluid temperature range for FPM seals °C (°F) -20 ... +80 (-4 ... +176)
Ambient temperature max. °C (°F) +50 (+122)
Viscosity range mm2/s (SUS) 20 ... 400 (98 ... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Max. allowable voltage variation % DC: ±10 AC: ±10
-1
Max. switching frequency h 15 000
2 -1
Switching time, on: at n=32 mm .s (156 SUS) ms DC: 30 ... 50 AC: 30 ... 40
2 -1
Switching time, off: at n=32 mm .s (156 SUS) ms DC: 10 ... 50 AC: 30 ... 70
Duty cycle % 100
7
Service life cycles 10
Enclosure type to EN 60 529 IP 65
Weigt - valve with 1 solenoid 1.6 (3.52)
kg (lbs)
- valve with 2 solenoids 2.2 (4.84)
Mounting position unrestricted

Spool Symbols
Type Symbol Crossover Type Symbol Crossover

3
HA 4010
p-Q Characteristics 2
Measured at n = 32 mm /s (156 SUS)

Operating limits for maximum hydraulic power transferred by the directional valve. Z11 1
For respective spool type - see spool symbols. C11 7
H11 4
P11 1
Y11 3
L21 6
B11 9
Operating pressure p [bar (PSI)]

Y41 7
Z21 1
C41 6
F11 6
R11 4
R21 5
A51 6
P51 1
Y51 3
C51 7
Z51 1
Z71 8
Z81 8
Z91 8
R31 6
H51 8
F51 8
X11 4
K11 8
N11 8
Flow Q [L/min (GPM)] X25 11
J15 1
J75 10

Dp-Q Characteristics 2
Measured at n = 32 mm /s (156 SUS)

Pressure drop Dp related to flow rate. P-A P-B A-T B-T P-T
Z11 2 2 3 3
C11 5 5 5 6 3
H11 2 2 2 3 3
P11 1 1 3 3
Y11 2 2 2 2
L21 2 2 3 3
B11 2 2 3 3
Pressure drop Dp [bar (PSI)]

Y41 3 3 3 3
Z21 2 3
C41 4 4 5
F11 1 2 3 3
R11 2 2 3 3
R21 2 2 3 3
A51 2 2
P51 1 3
Y51 2 2
C51 2 3 4
Z51 2 3
Z71 3 3
Z81 3 3
Z91 3 3 3
R31 2 3
H51 2 3
F51 2 3
X11 2 2 3 3
K11 2 3
Flow Q [L/min (GPM)] N11 2 2 3 3
X25 3 3 3
J15 2 2 3 3
J75 2 2

4
HA 4010
Valve Dimensions Dimensions in milimeters (inches)

40,5 (1.594)
Valve with two solenoids 12,5 (0.492) 33 (1.231)
30,2 (1.189)

45,5 (1.791)
32,5 (1.280)
0,75 (0.030)
5,1 (0.201)
7 (0.276)

21,5 (0.846)
)
6
2
12,7 (0.512) 0.1
3(
P
31 (1.220)

A
B
T
15,5 (0.610)
25,9 (1.019)

73,5 (2.894) 68 (2.677) 52 (2.047)

12 (0.472)
215 (8.465)

8
7
4

Æ9,5 (0.374)

Æ5,3 (0.209)

92,5 (3.641)
56,5 (2.224)
49,3 (1.940)

Æ45 (1.772)
P
a b
1,4 (0.055)
1,25 (0.049)
37,3 (1.468)
24 (0.945)

3 1 Æ8 (0.315)
5 2 9 3
Æ12,4 (0.488)

1 Solenoid a
Valve with one solenoid "a" 2 Solenoid b
Spool symbols R11, R21, A51, P51, 3 Manual override
Y51, Z51, C51, Z71, Z81, Z91, 4 Name plate
R31, H51, F51, X25 5 Square ring (4 pcs.)
9.25 x 1.68 supplied with valve
6 4 mounting holes
7 Electrical connecto, EN 1745301-803
P
8 Space required to remove connector
a
9 Solenoid fixing nut
8 (0.315) [Nut torque 2.95 ft-lbs (4 Nm)]

149,5 (5.886) 0.0004 / 4.0 [ in [


0.01 / 100 [ mm [
Rmax 6,3(248)[mm(min)]
0,8(32)

Valve with one solenoid "b" Required surface finish of


Spool symbols X11, Z11, C11, H11, interface
K11, N11, F11

P
b

5
HA 4010
Type of the Solenoid Coil
Designation Dimensional sketch Description

Solenoid coil with terminal for the electrical


E1 connector, EN 1745301-803.

Solenoid coil with integrated quenching diode


E2 (bipolar transil diode) and terminal for the
electrical connector, EN 1745301-803.

Solenoid coil with terminal for


E3A AMP-Junior-Timer electrical connector.

Solenoid coil with integrated quenching diode


E4A (bipolar transil diode) and terminal for
AMP-Junior-Timer electrical connector.

Solenoid coil with integrated rectifier and


terminal for the electrical connector,
EN 1745301-803.
E5

Manual Override
STANDARD CLOSED NUT

no designation Type N1
Dimensions Dimensions

Standard model of the manual override. Manual override with retaining nut.
Standard retaining nut of the solenoid. Can be used after removing nut.
RUBBER BOOT DETENT ASSEMBLY

Type N2 Type N3
Dimensions Dimensions

a
a
38 (1.259)
32 (1.259)
45 (1.772)

Manual override protected by rubber boot. Manual override holds the spool in the shiftet position.

6
HA 4010
Spool Speed Control Orifice
Type Dimension Description

Important: This directional valve provides control spool


2 soft shifting by means of orifice situated in the solenoid
armature.To ensure the proper function of the valve,
1 perfect air bleeding of the solenoid is required (by us of
bleeding plug (1). The plugs are accessible after
removing the rubber boot (2) from the solenoid retaining
T1 nut (3).

Switching times

Switching time, on and off ms 300 ... 800

2
The switching times shown are valid for viscosity n = 32 mm /s (156 SUS) and nominal
voltage. They are dependent upon working pressure and flow rate of the directional control valve

Orifice in P-Port
Type ÆD mm (inch) Dimensions Description

D1 1,0 (0.039)
P-port orifices limit the flow into the directional
control valve.
D2 1,5 (0.059)
Attention:
When the orifice in P port is additionally
D3 2,0 (0.079) mounted the standard used square ring NBR
Seal ring is replaced with O-ring from Viton.
D4 2,0 (0.087)

D5 2,0 (0.098)

7
HA 4010
Spool Ship Position Sensor
S1, S2 - Circuit diagram of the S4 - Circuit diagram of the
normally-open sensor normally-closed sensor The proximity sensor transforms
the spool position into an
Connector Connector
electrical step signal. It can be
PNP Sensor PNP Sensor
used with directional control
valves with one or two solenoids.
2

Technical Data of the Sensor S1, S4 S2


Rated power supply voltage V 24 DC
Power supply voltage range V 10 ... 30 DC
Rated current mA 200
Enclosure type of sensor to EN 60529 IP 67
Max. operating pressure bar (PSI) 50 (725) 210 (3046)
Switching frequency Hz 1000
Ambient temperature range °C (°F) -25 ... +80 (-13 ... +176)
Technical Data of the Connector
Power supply voltage range V 10 ... 30 DC
Ambient temperature range °C (°F) -25 ... +80 (-13 ... +176)
Indication yellow LED
Two-Position Directional Control Valve Dimensions in millimeters (inches)
Signal of solenoid a (b) Signal of sensor Sa (Sb) LED
S1, S2 - normally-open S4 - normally-closed S1, S2 S4
0 1 0 ON OFF
1 0 1 OFF ON

Sa (Sb)

a (b)

Three-Position Directional Control Valve Dimensions in millimeters (inches)


Signal of solenoid Signal of sensor Sa (Sb) LED
S1, S2 - normally-open S4 - normally-closed S1, S2 S4
a b Sa Sb Sa Sb Sa - LED Sb - LED Sa - LED Sb - LED
0 0 1 1 0 0 ON ON OFF OFF
1 0 0 1 1 0 OFF ON ON OFF

a Sa Sb b

8
HA 4010
Spare Parts
8
1 Electrical connector
B
2 Solenoid coil
3 Nut with seal 1
4 Orifice in P port with seal ring
5 Sensor
2
6 Connector of position sensor with LED
7 Seal kit
8 Mounting bolts
A

6
1 5 b
2
T 3

a A B

4 7
Solenoid coil
Coil type
Solenoid type E1 E2 E3A E4A E5
Order number
01200 16211400 24156100 24159600 24159700
01200* 24154300 - - -
02400 - 24157400 24159800 24159900
02400* 24154400
20500 -
23500 18849000
23500* 24154600
*CSA Upon request
Solenoid retaining nut with seal
Type of the nut Seal ring Order number
Standard nut 15844600
Closed nut 15844700
22 x 2
Nut with rubber boot 15844800
Nut with detent assembly 15844900
Connector of position sensor
Type designation Model Max. input voltage Ordering number
K02 connector of position sensor with LED 10...30 V DC 17364800
S1 normally-open sensor 10...30 V DC 16688500
S2 normally-open sensor 10...30 V DC 18961900
S4 normally-closed sensor 10...30 V DC 20725300
Orifice in P-port
Type ÆD mm (inch) Seal ring Order number
D1 1,0 (0.039) 15845600
D2 1,5 (0.059) 15845700
D3 2,0 (0.079) 9.25 x 1.75 15845800
D4 2,2 (0.087) 15846000
D5 2,5 (0.098) 15845900
Bolt kit
Dimensions, quantity Bolt torque Order number
M5 x 45 DIN 912-10.9 (4 pcs.) 8.9 Nm (6.6 ft-Ibs) 15845100
Seal kit
Type Dimensions, quantity Order number
Standard - NBR70 9,25 x 1,68 x 1,68 (4 pcs.) 17 x 1.8 (2 pcs.) 15845200
Viton 9,25 x 1,78 (4 pcs.) 17,17 x 1,78 (2 pcs.) 15845400
9
HA 4010
Electrical connector, EN 1745301-803
Connector A grey Connector B black
Type
Ordering number
K1 16202200 16202100
K5 16202600 16202500
K2 16202800 16202700
K3 16202400 16202300
K4 16203000 16202900
Electrical Connector, EN 175301-803
Connector B (black) without rectifier - M16x1.5
K1 230 V AC/DC
Connector A (grey) ( bushing bore Æ 6-8 mm)
Connector B (black) without rectifier - M16x1.5
K5 230 V AC/DC
Connector A (grey) ( bushing bore Æ 4-6 mm)
Connector B (black) without rectifier with LED
K2 and quenching diode - M16x1.5 12 ... 24 V DC
Connector A (grey) ( bushing bore Æ 6-8 mm)
Connector B (black) with rectifier - M16x1.5
K3 230 V AC
Connector A (grey) ( bushing bore Æ 6-8 mm)
with rectifier with LED
K4 Connector B (black) and quenching diode - M16x1.5 230 V AC
( bushing bore Æ 6-8 mm)

Recommended solenoid coils used with electrcial connector with rectifiers - type designation K3, K4
Rated supply source voltage
Type designation of the solenoid voltage
(permissible rated voltage variation ±10 %)
230 V AC / 0.17 A / 50 (60) Hz 20500

Preferred Types of Valves


Type Ordering Number Type Ordering Number
RPE3-062Z11/01200E1 15720300 RPE3-063Y11/02400E1 15728400
RPE3-063Z11/01200E1 15711300 RPE3-062R11/02400E1 15731100
RPE3-062Z51/01200E1 15719300 RPE3-062R21/02400E1 15734500
RPE3-063C11/01200E1 15712600 RPE3-062A51/02400E1 15732800
RPE3-062C51/01200E1 15719600 RPE3-062Y51/02400E1 15737400
RPE3-063H11/01200E1 15713500 RPE3-062J15/02400E1 15733500
RPE3-063Y11/01200E1 15714300 RPE3-062Z11/23050E5 15768800
RPE3-062R11/01200E1 15716000 RPE3-063Z11/23050E5 15747100
RPE3-062R21/01200E1 15717100 RPE3-062Z51/23050E5 21262800
RPE3-062A51/01200E1 15716700 RPE3-063C11/23050E5 15748900

Caution!
Ÿ When the distributor contains two electromagnets any of the two electromagnets can be switched on only after the
other one switches off. The electromagnets switching time on distributors with locking arrangement must not be
shorter than 60 ms.With directional valves with cushioned spool shifting, the switching time must correspond
with the shifting time.
Ÿ Distributors with other interconnections than those shown in the catalogue can be supplied on request.
Ÿ The packaging foil can be recycled
Ÿ The transport base plate can be returned to the manufacturer.
Ÿ Mounting screws M5 x 45 DIN 912-10.9 or bolts must be ordered separately.
The screws tightening torque is 8.9 Nm (6.6 ft-Ibs).
Ÿ The mentioned data only serve to describe the product and in no case are to be understood in terms of law as
guaranteed characteristics.

ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí


Tel.: +420-499-403 111
E-mail: [email protected]
www.argo-hytos.com

10 Subject to alteration without notice!