Datasheet RPE3-06 Ha4010 EN 01
Datasheet RPE3-06 Ha4010 EN 01
Functional Description
The RPE3 directional control valves consist of housing are integrated in the DIN connector socket as part of the
(1), a control spool (5) with two centering springs (4) and solenoid. The connectors (6, 7) can be turned by 90°. By
cylindrical operating solenoids (2, 3). loosening the nut (8), the solenoids can be turned or
The three-position directional control valves are fitted replaced without interfering with any seals of the valve.
with two solenoids and two springs. Two-position In the case of solenoid malfunction or power failure, the
directional control valves have either one solenoid and spool of the valve can be shifted by manual override (9),
one return spring or two solenoids and a detent provided the pressure in T-port does not exceed 25 bar.
assembly. The valve housing (1) is phosphate coated and the
The operating solenoids are DC solenoids. For AC solenoids (2, 3) are zinc coated.
supply the solenoids are provided with a rectifiers which
A B
a A B b
1
HA 4010
Ordering Code
RPE3-06 /
Directional Control
Valves Solenoid
Operated
Sensing of the end position
no designation without sensor
S1 normally-open sensor to 50 bar
Valve size (725PSI)
S2 normally-open sensor to 210bar
(3045 PSI)
S4 normally-closed sensor to 50bar
(725 PSI)
Number of valve positions
two positions 2 Seals
three positions 3 no designation NBR
V FPM (Viton)
FOR PREFERRED TYPES SEE BOLD TYPING IN ORDERING CODE, FUNCTIONAL SYMBOLS
AND TABLE OF PREFERRED TYPES ON PAGE 10
2
HA 4010
Technical Data
Valve size mm (US) D 06 (03)
Maximum flow L/min (GPM) see p-Q characteristics
Max. operating pressure at porte P, A, B bar (PSI) standard 350 (5076), according to CSA 320 bar (4641PSI)
50 (725) for version S1, S4
Max. operating pressure at port T bar (PSI)
and 210 (3000) for version S2
Pressure drop bar (PSI) see Dp-Q characteristics
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range for NBR seals °C (°F) -30 ... +80 (-22 ... +176)
Fluid temperature range for FPM seals °C (°F) -20 ... +80 (-4 ... +176)
Ambient temperature max. °C (°F) +50 (+122)
Viscosity range mm2/s (SUS) 20 ... 400 (98 ... 1840)
Maximum degree of fluid contamination Class 21/18/15 to ISO 4406
Max. allowable voltage variation % DC: ±10 AC: ±10
-1
Max. switching frequency h 15 000
2 -1
Switching time, on: at n=32 mm .s (156 SUS) ms DC: 30 ... 50 AC: 30 ... 40
2 -1
Switching time, off: at n=32 mm .s (156 SUS) ms DC: 10 ... 50 AC: 30 ... 70
Duty cycle % 100
7
Service life cycles 10
Enclosure type to EN 60 529 IP 65
Weigt - valve with 1 solenoid 1.6 (3.52)
kg (lbs)
- valve with 2 solenoids 2.2 (4.84)
Mounting position unrestricted
Spool Symbols
Type Symbol Crossover Type Symbol Crossover
3
HA 4010
p-Q Characteristics 2
Measured at n = 32 mm /s (156 SUS)
Operating limits for maximum hydraulic power transferred by the directional valve. Z11 1
For respective spool type - see spool symbols. C11 7
H11 4
P11 1
Y11 3
L21 6
B11 9
Operating pressure p [bar (PSI)]
Y41 7
Z21 1
C41 6
F11 6
R11 4
R21 5
A51 6
P51 1
Y51 3
C51 7
Z51 1
Z71 8
Z81 8
Z91 8
R31 6
H51 8
F51 8
X11 4
K11 8
N11 8
Flow Q [L/min (GPM)] X25 11
J15 1
J75 10
Dp-Q Characteristics 2
Measured at n = 32 mm /s (156 SUS)
Pressure drop Dp related to flow rate. P-A P-B A-T B-T P-T
Z11 2 2 3 3
C11 5 5 5 6 3
H11 2 2 2 3 3
P11 1 1 3 3
Y11 2 2 2 2
L21 2 2 3 3
B11 2 2 3 3
Pressure drop Dp [bar (PSI)]
Y41 3 3 3 3
Z21 2 3
C41 4 4 5
F11 1 2 3 3
R11 2 2 3 3
R21 2 2 3 3
A51 2 2
P51 1 3
Y51 2 2
C51 2 3 4
Z51 2 3
Z71 3 3
Z81 3 3
Z91 3 3 3
R31 2 3
H51 2 3
F51 2 3
X11 2 2 3 3
K11 2 3
Flow Q [L/min (GPM)] N11 2 2 3 3
X25 3 3 3
J15 2 2 3 3
J75 2 2
4
HA 4010
Valve Dimensions Dimensions in milimeters (inches)
40,5 (1.594)
Valve with two solenoids 12,5 (0.492) 33 (1.231)
30,2 (1.189)
45,5 (1.791)
32,5 (1.280)
0,75 (0.030)
5,1 (0.201)
7 (0.276)
21,5 (0.846)
)
6
2
12,7 (0.512) 0.1
3(
P
31 (1.220)
A
B
T
15,5 (0.610)
25,9 (1.019)
12 (0.472)
215 (8.465)
8
7
4
Æ9,5 (0.374)
Æ5,3 (0.209)
92,5 (3.641)
56,5 (2.224)
49,3 (1.940)
Æ45 (1.772)
P
a b
1,4 (0.055)
1,25 (0.049)
37,3 (1.468)
24 (0.945)
3 1 Æ8 (0.315)
5 2 9 3
Æ12,4 (0.488)
1 Solenoid a
Valve with one solenoid "a" 2 Solenoid b
Spool symbols R11, R21, A51, P51, 3 Manual override
Y51, Z51, C51, Z71, Z81, Z91, 4 Name plate
R31, H51, F51, X25 5 Square ring (4 pcs.)
9.25 x 1.68 supplied with valve
6 4 mounting holes
7 Electrical connecto, EN 1745301-803
P
8 Space required to remove connector
a
9 Solenoid fixing nut
8 (0.315) [Nut torque 2.95 ft-lbs (4 Nm)]
P
b
5
HA 4010
Type of the Solenoid Coil
Designation Dimensional sketch Description
Manual Override
STANDARD CLOSED NUT
no designation Type N1
Dimensions Dimensions
Standard model of the manual override. Manual override with retaining nut.
Standard retaining nut of the solenoid. Can be used after removing nut.
RUBBER BOOT DETENT ASSEMBLY
Type N2 Type N3
Dimensions Dimensions
a
a
38 (1.259)
32 (1.259)
45 (1.772)
Manual override protected by rubber boot. Manual override holds the spool in the shiftet position.
6
HA 4010
Spool Speed Control Orifice
Type Dimension Description
Switching times
2
The switching times shown are valid for viscosity n = 32 mm /s (156 SUS) and nominal
voltage. They are dependent upon working pressure and flow rate of the directional control valve
Orifice in P-Port
Type ÆD mm (inch) Dimensions Description
D1 1,0 (0.039)
P-port orifices limit the flow into the directional
control valve.
D2 1,5 (0.059)
Attention:
When the orifice in P port is additionally
D3 2,0 (0.079) mounted the standard used square ring NBR
Seal ring is replaced with O-ring from Viton.
D4 2,0 (0.087)
D5 2,0 (0.098)
7
HA 4010
Spool Ship Position Sensor
S1, S2 - Circuit diagram of the S4 - Circuit diagram of the
normally-open sensor normally-closed sensor The proximity sensor transforms
the spool position into an
Connector Connector
electrical step signal. It can be
PNP Sensor PNP Sensor
used with directional control
valves with one or two solenoids.
2
Sa (Sb)
a (b)
a Sa Sb b
8
HA 4010
Spare Parts
8
1 Electrical connector
B
2 Solenoid coil
3 Nut with seal 1
4 Orifice in P port with seal ring
5 Sensor
2
6 Connector of position sensor with LED
7 Seal kit
8 Mounting bolts
A
6
1 5 b
2
T 3
a A B
4 7
Solenoid coil
Coil type
Solenoid type E1 E2 E3A E4A E5
Order number
01200 16211400 24156100 24159600 24159700
01200* 24154300 - - -
02400 - 24157400 24159800 24159900
02400* 24154400
20500 -
23500 18849000
23500* 24154600
*CSA Upon request
Solenoid retaining nut with seal
Type of the nut Seal ring Order number
Standard nut 15844600
Closed nut 15844700
22 x 2
Nut with rubber boot 15844800
Nut with detent assembly 15844900
Connector of position sensor
Type designation Model Max. input voltage Ordering number
K02 connector of position sensor with LED 10...30 V DC 17364800
S1 normally-open sensor 10...30 V DC 16688500
S2 normally-open sensor 10...30 V DC 18961900
S4 normally-closed sensor 10...30 V DC 20725300
Orifice in P-port
Type ÆD mm (inch) Seal ring Order number
D1 1,0 (0.039) 15845600
D2 1,5 (0.059) 15845700
D3 2,0 (0.079) 9.25 x 1.75 15845800
D4 2,2 (0.087) 15846000
D5 2,5 (0.098) 15845900
Bolt kit
Dimensions, quantity Bolt torque Order number
M5 x 45 DIN 912-10.9 (4 pcs.) 8.9 Nm (6.6 ft-Ibs) 15845100
Seal kit
Type Dimensions, quantity Order number
Standard - NBR70 9,25 x 1,68 x 1,68 (4 pcs.) 17 x 1.8 (2 pcs.) 15845200
Viton 9,25 x 1,78 (4 pcs.) 17,17 x 1,78 (2 pcs.) 15845400
9
HA 4010
Electrical connector, EN 1745301-803
Connector A grey Connector B black
Type
Ordering number
K1 16202200 16202100
K5 16202600 16202500
K2 16202800 16202700
K3 16202400 16202300
K4 16203000 16202900
Electrical Connector, EN 175301-803
Connector B (black) without rectifier - M16x1.5
K1 230 V AC/DC
Connector A (grey) ( bushing bore Æ 6-8 mm)
Connector B (black) without rectifier - M16x1.5
K5 230 V AC/DC
Connector A (grey) ( bushing bore Æ 4-6 mm)
Connector B (black) without rectifier with LED
K2 and quenching diode - M16x1.5 12 ... 24 V DC
Connector A (grey) ( bushing bore Æ 6-8 mm)
Connector B (black) with rectifier - M16x1.5
K3 230 V AC
Connector A (grey) ( bushing bore Æ 6-8 mm)
with rectifier with LED
K4 Connector B (black) and quenching diode - M16x1.5 230 V AC
( bushing bore Æ 6-8 mm)
Recommended solenoid coils used with electrcial connector with rectifiers - type designation K3, K4
Rated supply source voltage
Type designation of the solenoid voltage
(permissible rated voltage variation ±10 %)
230 V AC / 0.17 A / 50 (60) Hz 20500
Caution!
When the distributor contains two electromagnets any of the two electromagnets can be switched on only after the
other one switches off. The electromagnets switching time on distributors with locking arrangement must not be
shorter than 60 ms.With directional valves with cushioned spool shifting, the switching time must correspond
with the shifting time.
Distributors with other interconnections than those shown in the catalogue can be supplied on request.
The packaging foil can be recycled
The transport base plate can be returned to the manufacturer.
Mounting screws M5 x 45 DIN 912-10.9 or bolts must be ordered separately.
The screws tightening torque is 8.9 Nm (6.6 ft-Ibs).
The mentioned data only serve to describe the product and in no case are to be understood in terms of law as
guaranteed characteristics.