SU:M Series features
vvacy ° ° °
acy e e e
sv ° e °
SPONT ° ° e
‘Apnea Backup ° e e
Mask Ventilation ° ° .
(Non-Invasive)
PRC ° i
18i-Level e e
Anstovent e °
HEV °
(SHFV/OHFV)
ery Tend (72 hs) ° ° °
(Graphic & Tabular
‘Auto Nebulizer ° ° e
CS | 02 streamo e ° °
(with Nasal Cannula)
Hemo-Dynamics e e e
(with SpO2 & EtCO2)
Proximal Sensor e °
(Adult & Neonate)
Head Office Sales Office Customer Service
+82 70 7119 2500 +82 707119 2520 +82 707119 2510
| 21, Sangjseok-gil, Paju-si, Gyeonggi-do, 10911, Korea | wwwmek-ics.com |
[email protected]>
Intensive Care Ventilator
SU:M series
Innovative Technology
‘Advanced Proportional Solenoid Teehnology(PSOL)
Active exhalation valve
Block type pneumatic sytem
Mat-sfety mechanism
Tube-Piston HFVIHigh Frequency Ventilation)
User Friendly
User friendly pop-up menu with rotary encoder & touch screen
See arenes corn -
se ee
Se ney
High Resolution Graphic Interface
‘lows set & monitored parameters tobe vewed on a singe screen
‘Smutaneous play of 5 Waveform 8 Loops
CGomprenesive alm monitoring
Graphical Tabular tends up to 72 hours
12" touch screen LCD Display
Advanced Features Nu
‘Apnea backup
Manual / Auto Nebulizer
Lung Mechanics functions-Compliance and Resistance, Auto PEEP
Heated Exhaltion Valve
Mask (Non-Invasive) Ventilation
Measurement of Atmosphere and Temperatures (BTPS)
Maintenance, System Check & Monitoring with an unique program
Optional Features
Mode — : AutoVenta, SHFV, DHFV,tBiLevel , PRVC, Or Stream@
Module: Hemo-Dynamics with SpO> and £tCO>
Accessory ; Proximal sensor
NMiSK intensive care systemian
Intelligent Ventilator for ICU
‘The ineligent Ventilator has its functions to be adaptable for ICU. However, MEK ICS's ICU Ventilatoy,
SUM series, is compatible to cover all ages from an Adult to @ Neonate in an Intensive Care Unit, All
in One.
Intelligent
1 Block Type Pneumatic System
High performance Block type pneumatics and
microprocessor controled electronic hardware
system allows sensitive and precise breath deliv
ery for critically ill patients
| Advanced Proportional Solenoid Valve
(PSOL) Technology
Ensures faster safer and accurate gas delivery
hich also reduces. the Werk of Breathing and
helps in improving Synchrony.
|= Active Exhalation Valve
‘Actively controls and maintains the target
pressure. It allows unrestricted breathing during
booth inspiratory as well as expiratory phases of
the breathing cycles. This valve also vents excess
pressure due to Pressure overshoot, patients
ough, etc. This promotes better Patient - Venti-
lator Synchrony and potentially decreases the
need for sedation,
© Differential Type Flow Sensor
Sensor is very rugged and reliable offering
exceptional response, as well as, accurate moni
toring, even when used with a Nebulizer
Designed with a high end pneumatic base, and
Using a Differential Type Flow Sensor, the
assures the user of long service time intr:
vals, The low cost of spares and very few
consumables provides the customer with very
affordable cost of ownership.
V Standby
Trend
Trend mode simultaneously displays the past
records of patient's statues in numeric, as well
2s, graphical form. By adjusting the cursor, the
user can revew the monitored data for any
specific time, in the past 72 hours. The built in
trend function record up to 11 parameters such
2 Volume, Pressure, Flow etc, with a selectable
time interval if 1/10/30/60 breaths.
V Trend‘Automatic Measurement of both Altitude and
Temperature: An Aritifcial Intelligence internal
sensor to measure Altitude and Temperature
The volume of atmosphere is changeable
depending on Height, Humidity and Temperature.
Its measurement result is relative considering the
environments condition. Most conventional Venti-
Mask Ventilation is the most basic yet the most
essential, skill in airway management. It is the
primary technique of ventilation tracheal intuba-
tion or insertion of any airway device. Its most
Unique role, however, is as a rescue technique for
ventilation should tracheal intubation fail or prove
dificult, MEK Mask Ventilation on/off mode maxi-
lators measures Temperature and Altitude by each rmizs its leakage compensation up to SOLPM.
Users which can be inaccurate, however with
MEKICS's internal acute Atimeter and Thermo
ter, a volume for each patient will hve absolute
precision,
‘Auto Peak Flow: Automatic setup for its conve- 02 stream
rience. 1m Proximal Sensor
Every person has a different weight, lung capac | Hemo-Dynamic function
ity and breathing period, Until now,
has its auto measruement function to calculate
Ideal Body Weight, Breathing Volume and Inspira-
tion period for each patient to indicate a Auto Peak
Flow data. Just touch the screen for results.
Maintenance and System Check with an unique
program: Susceptible Maintenance Program for
Technical Support.
Due to its feature, life-saver, the accuracy is the
most significant fact to handle, For 2 fine data
adjustment, MEK ICS provides the strong mainte
nance program for easy access and control,
TA)
bePatient Safety: It employs lung- protective rules and
adjusts the ventilator pattern based on the patient's
pulmonary mechanics and spontaneous respiratory
activity to maintain preset minute ventilation
Patient comfort AutoVent® mode promotes free
breathing for patients in all ventilation modes and
phases. It encourages spontaneous activity right
from the start of ventilation and promotes weaning
from fist deployment
‘AutoVent@® delivers the optima tidal volume safely
at the lowest pressure possible, combining the
benefits of pressure-contralled ventilation with @
volume guarantee. It optimizes and synchronizes
With lung compliance and airway resistance allow-
ing the clinician to concentrate on the patient
rather than on the device.
‘AutoVent® mode searches by itself for monitoring
‘8 graphic for target and current breathing to
synchronize on the patient
It preserves the low Alveolar Ventilation limit when
the breathing time decrease to control apnea limit
‘automatically for 10 seconds.
{Bi-Level Mode is @ true mixed mode of ventilation
that combines the attributes of mandatory and
spontaneous breathing in which the patient has the
ablity to breathe spontaneously at two levels of
PEEP(PL and PH) with or without Pressure Support
Due to its ability to allow unrestricted spontaneous
breathing at any moment of the ventilation phase,
it improves Patient Ventilator Synchrony,
This feature enables efficient cost management
and quick recovery of the patient by reducing
sedation ‘so. provides Pressure
Support if required. This assures a more comfort
able environment to the patient by providing
Pressure Support Ventilation, to all spontaneous
breaths.
Pr phk ‘\
IGE
‘The PRVC mode provides adaptive response and
the stable volume to patient in changing patient's
compliance and airway resistance,
1m TCPL (Time- Cycled Pressure Limited) for
minute volume ventilator
Adaptive support to patients change
complance.High Frequency Ventilator
Nine] oar] ual High Frequency Ventilatio
SHFV and DHFV:
‘The Safest Respiratory Care Process in High Frequency Ventilation.
For a immature baby who has a tiny lung, the universal ventilator has not been developed well to give them a proper treat-
‘ment. However, with MEKICS's single and dual high frequency ventilation, it reduces lung injury, proved by medical
research,
Wide range
Single High Frequency Ventilation mood covers from neonate to
adult patients with a wide range of frequency (5-30Hz, 2-1800bpm)
Unlike the conventional ventilators.
[Pressure & Flow)
PEEP high HFU low
SHFqV Mode
\
Monitoring PEEP
PEEP Jow Base Flow
Assist the shortage on the device
Leak compensating capabilties difer markedly between ventilators,
but pressure-targeted ventilators are preferred for noninvasive
positive pressure ventilation in patients with substantial air leaking,
‘Adequate inspiratory flows and durations should be used. Dual
High Frequency Ventilation mode prevents the air leakage to
‘compensate between the actual breathing volume to a patient and
‘the setup tidal volume providing by the exhalation period
DHFaV Mode
+ BaseFlow [| Rate fom
& N apirle Motoring PEP
‘cng Cue
Intl oparaton of PRC ft Btn) Pressure Repulation operation at Compan ange of Patent
MEKICS
beSU:M Series Additional Options
Additional Options
O2 Stream®
‘This function is similar to Nasal CPAP and controls a
‘micro-miniature flow along with adjusting O2 flow. The
conventional CPAP must be used with a humidifier in order
‘to a patient’ breathing air should be moisture but O2
Stream® flows 02 atthe same time with air the breathing
air willbe easy fora patient’ nasal and lung. 02 Stream®
supports 2 positive airway pressure on the control flow to
teduce the dead space at a patient’ lung
Hemo-Dynamic function
EtCO2 and SpO2
The partial CO2 rebreathing technique has been demon-
strated to accurately measure the effective pulmonary
capilary blood flow (PCBF) indifferent clinical situations.
Usually, PCBF is calculated from changes in C02 elimina
tion (VCO2) and end-tidal partial pressure of COZ
(PexCO2), which can be obtained noninvasively. The
performance ofthe partial CO2 rebreathing technique can
bbe improved by means of arterial blood gas sampling and
fan algorithm that takes in account the effects of non-
equbration of PetCO2 during rebreathing and the varia~
tion of PeCO2 to PetCO2 differences from the on
rebreathing to the rebreathing period, Such an algorithm
‘may prove useful under moderately increased alveolar
dead space and normal to hypo-dynamic ca
Proximal flow measured at the patient's air way can be
‘substantially different from flow measured inside or at the
ventilator. Many Ventilators measure flow, not at the proxi-
‘mal airway, but close to the ventilator. This can result in 2
‘substantial difference between what is delivered to the
patient and what the ventilator reports as delivered due to
‘the wasted compression volume and differences due to
humidification. Thus for more accurate monitoring of
delivered volume and of the patient's expired volume, the
flow sensor should be placed between the breathing
Circuit wye and the endotracheal tube. MEK proximal
‘sensor has its essential functions for a patient, especially
for both premature and neonate, to use an accurate flow
measurement and tube compensation needs. Its assist
safest breathing is up to 200m,
INTEN:
VE CARE SYSTEM(
MC200
Air Compressor Uni
1MC200 is originally designed to use our ICU ventilators. In case of using other manufacturers ventilator to M200, itis
recommended to check the maximum capacity of flow consumption of the connected ventilator and the maximum capacity
of flow production of MC200.
1 Compact size
1m Portable type for easy install and move
1m Low noise by double slencer system
Absorption of vibration & _dust-protection
applied structure enable MC200 to perform
superior vibration coefficient with extremely
quiet operation
1 User convenient display
1% Total used time display enable timely effective
‘maintenance efforts
1m Easy maintenance by cartridge type replacement
of service parts
1m Parallel connection to WALL AIR is avalable
1 Safety solution useful for preventive maintenance
(eg. Temperature warning system & manual shut
down is available)
© Available to operate in connection with maximum
2 units of ventilatr simultaneously
(Use on MEKICS ICU ventilator series)
MEKICS