0% found this document useful (0 votes)
118 views17 pages

All Static

The document provides technical specifications for Powerscreen static screening plants. It describes the key components of the screenbox, structure, and optional configurations. The screenbox uses side-tensioned, huckbolted design with spray bars and nozzles for washing. The robust structure features walkways, handrails, and a rolling chute system. Various size options are listed along with technical dimensions and specifications. Optional additions include extended heights, additional decks, wear linings, and discharge configurations.

Uploaded by

bogdanmichael
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views17 pages

All Static

The document provides technical specifications for Powerscreen static screening plants. It describes the key components of the screenbox, structure, and optional configurations. The screenbox uses side-tensioned, huckbolted design with spray bars and nozzles for washing. The robust structure features walkways, handrails, and a rolling chute system. Various size options are listed along with technical dimensions and specifications. Optional additions include extended heights, additional decks, wear linings, and discharge configurations.

Uploaded by

bogdanmichael
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

STATIC SCREENBOX

Technical Specification

INTRODUCING THE
POWERSCREEN STATIC
SCREENBOX
TECHNICAL SPECIFICATION

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

The Powerscreen static screening plant, incorporates screenbox, chutes, walkway and
support structure. All boxes are designed with the most advanced design systems available
and are huck bolted to eliminate stress areas created by welding. The static structure which
carry’s the screen unit is robust, easy to assemble and includes integrated material discharge
chutes. Walkways, access steps and rolling chute system allow easy access to view
production and carry out maintenance.

Features
• Side tensioned screen box
• Spray bars spread evenly on all decks
• Plastic fan tail spray nozzles
• Galvanized walkway & handrails
• Rolling chute system
• Manual screen angle adjustment
• Electric drive

Advantages
• Steps and walkways provide easy access for maintenance
• Steps can be placed at any corner of the structure
• Rolling chute allows greater access to screen mesh when changing
• Robust easy to assemble steel support structure
• Rubber lined wear parts
• Complies with all relevant essential health and safety requirements
• High pressure plastic fan tail nozzles deliver clean end product
• Huck bolted, four bearing, free floating vibrating system eliminates the need for
fine tuning
• High capacity (depending on mesh size and material type)
• Low maintenance

Applications
• Sand and gravel
• Coal
• Crushed materials
• Slag
• Recycled materials
• All forms of concrete, mortar and asphalt sand
• Iron Ore
• Lake and beach sand
• Silica glass

Most materials which need to be washed.

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification
Technical dimensions

20x6 16x5 12x5 10x5 8x4


6x 4.8 x 16' x 3.65 x 12' x 3x 10' x 8' x
Screen Box Size 1.8m 20'x6' 1.5m 5' 1.5m 5' 1.5m 5' 2.4 x 1.2m 4'
2 Bearing 4 Bearing 4 Bearing: 2-deck 4 Bearing 4 Bearing
2 Bearing: 3-deck
13' 13' 13'
Width 7.36m 24' 1" 2.72m 9' 4m 1" 4m 1" 4.02m 2"
17' 36' 35'
Length 15.3m 50' 2" 5.344m 7" 11.2m 9" 10.7m 1" 2.8m 9' 2"
23' 19'
Height 7.8m 25' 7" 7.09m 3" 6.3m 20' 6.2m 20' 5.99m 8"
electric motor 30HP 22Kw 20HP 15Kw 13HP 10Kw 13HP 10Kw 7.5HP 5Kw
Water feed pipe 150mm 6" 150mm 6" 150mm 6" 150mm 6" 100mm 4"
Top Deck Spraybars 10 off 8 off 6 off 5 off 5 off
Bottom Deck Spraybars 8 off 8 off 6 off 6 off 5 off
6' 6' 6'
Waste Water Discharge 1.64m 5' 5" 1.85m 6'1" 2.09m 11" 2.09m 11" 2.09m 11"
Product Discharge Height 2.35m 7' 8" 2.58m 8' 6" 2.80m 9'2" 2.80m 9'2" 2.85m 9'4"

Options
• 3 Deck Variant
• Dry, Rinser & Part Rinser
• Level frame
• Modular polyurethane decks
• Rubber side tensioned mesh
• Aluback wear plate in wash box
• 10” sand slurry pipes
• Rubber lined Catch box and Division plates
• Rubber lined Transfer box
• Adjustable Division plates
• Hydraulic Drive
• Brass or plastic nozzles
• Height extensions to feed Powerscrub and Finesmaster ranges

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification
Screen

• Side tensioned Huckbolted screen box


• Spray bars spread evenly on all decks
• Plastic fan tail spray nozzles
• Electric drive
• Mesh, Rubber decks or Polyurethane available

Side tensioned Screenbox (Quick Heavy duty springs


Huck Bolted Release wedges optional)
screenbox

Polyurethane decks High pressure


or mesh available spraybars with plastic
nozzles

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification
Structure

• Modular quick erect structure


• Galvanized handrails
• Rolling chute system
• Manual screen angle adjustment
• Non slip Flowforge panels used for walkways
• Manifold with Ball valves and heavy duty rubber hosing attached to structure
• Washbox with integrated spraybar

Integrated manifold Roll in chute for transfer of Bolt up structure with


with ball valve and material from screen to chutes, Galvanized walkways
high pressure rubber and ease of access for mesh and handrails
hosing changes

Catchbox.
Adjustable division
plates (yellow)&
Rubber lining optional

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

20 X 6 2 DECK WITH STANDARD STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

20 X 6 3 DECK WITH STANDARD STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

20 X 6 2 DECK WITH 1.3M EXTENDED STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

20 X 6 3 DECK WITH 1.3M EXTENDED STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

16 X 5 2 DECK WITH STANDARD STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

16 X 5 3 DECK WITH STANDARD STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

16 X 5 2 DECK WITH 1M EXTENDED STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

16 X 5 3 DECK WITH 1M EXTENDED STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

12 X 5 2 DECK WITH STANDARD STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

12 X 5 3 DECK WITH STANDARD STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

10 X 5 2 DECK WITH STANDARD STRUCTURE

All specifications subject to change without prior notice.


STATIC SCREENBOX
Technical Specification

8 X 4 2 DECK WITH STANDARD STRUCTURE

The material in this document is for information only and is subject to change without
notice. Powerscreen International Distribution Ltd. Assumes no liability resulting from
errors or omissions in this document or from the use of the information contained herein.
Due to continual product development we reserve the right to change specifications
without notice. Photographs are for illustrative purposes only. Some or all of the machines
in the illustrations may be fitted with optional extras. Please check with your Dealer for
details on optional extras.

Powerscreen International Distribution Ltd.


200 Coalisland Road Tel: +44(0) 28 8774 0701
Dungannon Fax: +44(0) 28 8774 6569
Co. Tyrone Email: [email protected]
N.Ireland Web: www.powerscreen.com
BT71 4DR Revised: 29/02/08

All specifications subject to change without prior notice.