EMS100 Setup 250

1. This document provides setup instructions for the Maretron EMS100 engine monitoring device and lists compatible Yanmar engines and instrument panels. 2. To enter setup mode, go to Main Menus > Configuration > Device Configuration > EMS100. 3. Compatible engines and instrument panels are identified in tables that specify available functions for gauges, senders, and alarms for each engine model.

Uploaded by

Gera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views5 pages

EMS100 Setup 250

1. This document provides setup instructions for the Maretron EMS100 engine monitoring device and lists compatible Yanmar engines and instrument panels. 2. To enter setup mode, go to Main Menus > Configuration > Device Configuration > EMS100. 3. Compatible engines and instrument panels are identified in tables that specify available functions for gauges, senders, and alarms for each engine model.

Uploaded by

Gera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

This document is provided as an aid for the setup process of the Maretron EMS100 Analog engine monitoring device.

Please refer to the EMS100 Checklist for verification of compatibility, or refer to the list below of compatible engines and
instrument panels.
To enter Ems100 Setup: Main Menus<Configuration<Device Configuration<EMS100

Step 1. 2. 3.

Set up each gauge and sender according to Yanmar tables below.


4. 5. 6.

9014 N. 23rd Avenue, Suite 10, Phoenix AZ 85021, Phone: (602) 861-1707, Fax: (602) 861-1777
1. Sender Type should be enabled as Yanmar. Example #4
2. Select your gauge type: No gauge, Yanmar/VDO, Yanmar. Example #5
3. Flywheel tachometer teeth # can be located on lower part of tachometer. Example #6(note newer instrument panels utilize an alternator signal,
this signal is amplified greatly and requires the Flywheel teeth to be configured to a lower amount ( ie 10-18 count).
4. Please refer to tables listed below provided by Yanmar.

Available
o yes x
no

Type of
instrument panel

Function Digital B-type Panel

1 Switch unit
1-1 Key switch for GLOW/OFF/ON/START (4-position
switch)
O
1-2 Push button switch for engine stop O
1-3 Moisture cap for key switch O
2 Alarm lamp unit
2-1 Battery low charge alarm O
2-2 Coolant high temperature alarm O
2-3 Lubricating oil low pressure O
2-4 Water in sail drive seal alarm O
2-5 Water in fuel filter alarm X
2-6 Sea water insufficient flow alarm X
3 Meters
3-1 Lubricating oil pressure meter X
3-2 Coolant temperature meter X
3-3 Hour meter O
3-4 Tachometer O
4 Audible alarm buzzer O

9014 N. 23rd Avenue, Suite 10, Phoenix AZ 85021, Phone: (602) 861-1707, Fax: (602) 861-1777
New C-type

New B-type New C-type New D-type

B-type
Type of instrument panel Panel New C-type Panel New D-type Panel
Function New

1 Switch unit
1-1 Key switch for GLOW/OFF/ON/START(4-position
switch) O O O
1-2 Engine stop switch O O O
1-3 Alarm buzzer(C.W.Temp. L.O. Pressure) O O O
1-4 Alarm buzzer stop switch O O O
1-5 Illumination switch for meters O O O
2 Alarm lamp unit

Battery not charging O O O


C.W. high temperature O O O
L.O. low pressure O O O

9014 N. 23rd Avenue, Suite 10, Phoenix AZ 85021, Phone: (602) 861-1707, Fax: (602) 861-1777
Boost pressure high(for 4LHA-STP) X O O
3 Tachometer with hour meter O O O
4 Sub meter unit O O O
4-1 L.O. pressure meter X O O
4-2 C.W. Temperature meter X O O
4-3 Boost meter(turbo) X X O
5 Quartz clock X X O

Engine Compatibility List

1GM10 4LHA-HTP 6LY2A

2YM15 4LHA-DTP 6CXM-GTE

3YM20 4LHA-STP

3YM30 4LHA-DTZP

3JH4E 4LHA-HTZP

4JH4E 4LHA-STZP

4JH4AE 6LPA-DTP

4JH3-TE 6LPA-STP

4JH3-THE 6LPA-STZP

4JH3-DTE 6LPA-DTZP

4JH4-TE 6LPA-STP2

9014 N. 23rd Avenue, Suite 10, Phoenix AZ 85021, Phone: (602) 861-1707, Fax: (602) 861-1777
4JH4-THE 6LYA

9014 N. 23rd Avenue, Suite 10, Phoenix AZ 85021, Phone: (602) 861-1707, Fax: (602) 861-1777