Design Reviewer Quiz 1
Design Reviewer Quiz 1
Quiz Instructions
WARNING: If there are conflicts between a stated word and the number/amount/figure described, the
stated/spelled word shall prevail. Should there be conflicts between two (2.0) stated quantities, the
higher figure shall prevail.
IMPORTANT NOTE: For this examination in this subject, the Examinee shall be allowed to make full use
open books) ONLY of Printed Rule VII and Rule VIII of the 2004 Revised Implementing Rules and
Regulations (IRR) of the Presidential Decree (P.D.) No. 1096, otherwise known as the 1977 National
Building Code of the Philippines (NBCP). The printed copy shall be subject to inspection during the
examination. This will be confiscated in the event that any markings are found thereon.
A newlywed couple have decided to set-up real estate development corporation. They have lot of
inherited land properties, and their initial project is to build a 2-storey duplex house in Davao City
located within subdivision of low density. With this particular project, they have envisioned to cater
markets of working couples that in junior executive positions. You have recently passed the board
examination for, and the couple was impressed by your performance being one of the topnotchers. The
design brief is to design and at the same time manage the
Each unit must contain a pave 2-carport with dimension 3.0 m x 5.0 m per car at front yard and a 2.0 m x
2m covered porch. Every unit of the duplex will equally share the total lot area. Each of the ground
floors must contain foyer, stairs, T&B, and maid's room all of which are abutting the
common wall. The entrance foyer measure 2m depth x 2.5m width. Use 100mm thick concrete slab on
grade for ground floors.
The kitchen should be located across the maid's room while living room and dining room are located
opposite the common wall.
Second floor contains stairwell/stairs, master's bedroom with 1 walk-in-closet. T&B and balcony and
bedroom 1 with walk-in-closet and T&B. The second floor will utilize the maximum allowable gross floor
area
Entrance steps or paved walkway is provided the width is the same as the porch.
The Site:
The project site is a parcel of land bounded on the SE along line 1-2 by lot 2; on the SW along 2-3 by
RROW, on the NW along line 3-4 by lot 3; on the NE along 1-4 by lot 4. The lot technical description is of:
S 76° 33 N,15.0m to point 2; N 13° 27' W,16.0m to point 3; N 76° 33' E,15.0m to point 4:S 13° 27'
E,16.0m to point 1.The lot is sloping upward SW 2-3 1/16.
Design Objectives:
The Office of the Building Official (OBO) has approved more than 60% paved front yard. Each unit of
duplex house should optimize the use of the lot. It should also have 2 carports and should not be
sacrifice because the prospective clients are working couples with their own cars. Take note that the
subdivision developer has loosen up on the use of the yard giving away to the needs of the time.
A rich businessman saw a profitable opportunity in a 3-storey old building built in a lot in Cubao, Quezon
City. His secretary researched for known architects in the area. They eventually hired the QC-based
architect partners Doloras+Partners to design a low-rise apartment building to be built in the said lot
and to manage its construction. The businessman will enter into a single prime contract with the design
firm to avoid the hassle of multiple communications with different people. The main target market of
the apartment building is the employees of the BPO companies in Cubao.
The businessman requires that the lot be maximized to its full development potential with 2 side
firewalls. He requires an apartment building with 5 floors and a roof deck. All building laws and codes
must be complied.The maximum TGFA allowable for the lot is 12 x 80%. He expects an administration
room on the ground floor and 4 units in each of the floors above. Each unit must house at least 6
employees served with one 1 full bathroom and a separate shower enclosure. An extra shared
bathroom is provided in each floor accessible to the hallway. The roof deck will have parapet walls
around. The businessman wants the roof deck accessible by the building leases for whatever uses.
The Site:
The 3-storey building is built in a 15m x 270sqm rectangular lot. One of the longer sides faces east while
the single frontage faces south and the public RROW which has a 1.2m sidewalk. The site uniformly
slopes 3% upward towards the rear. Once the old building is demolished and the new apartment
building is constructed, the businessman expects good profit from the rental of the units.
You were hired by Delos Santos family to design their house in their newly bought site located in Biñan,
Laguna. To describe the family, Mr. Delos Santos is a real estate broker who likes woodworking. His wife,
Mrs. Delos Santos is an accountant who likes gardening and collecting native or indigenous plants. Their
two daughters like weightlifting with the older one having won multiple local competitions. The siblings
are very close to each other.
The project site is a corner lot in an exclusive executive subdivision in Biñan, Laguna, cornering the
streets of Sampaguita which runs N-E and Rosas which runs S-E . Both roads serve as the primary roads
for this project. The following lot descriptions were given:
image.png
Line 1-2 is bounded by a private lot, Line 2-6 by road lot and Line 6-1 by a private lot. The site slopes
downward towards Rosas St. by 2%.
From the multiple interviews, the summary of their requirements are as follows:
a. The family likes the famous Francisco Mañosa and wants a house that embodies Filipino culture in
terms of materials and aesthetics. Wood parquet is the preferred finish for the bedrooms. The façade
shall incorporate wood finishes and natural stones which will complement the surrounding gardens.
b. A covered and paved carport is desired on the northern corner of the lot, measuring 6m x 5.5m and
abutting Sampaguita street. As much as possible all remaining open spaces will be permeable gardens.
Adding to the paved carport, a paved 1.5m x 15 sqm wide path on the front yard is provided to serve as
path from the carport to the living area.
c. The ground floor will house the 30sqm enclosed woodworking area on the northwest, a living room
on southeast, dining room and other areas.
d. The second floor will have a master bedroom facing both the roads. A shared bedroom for the two
daughters is provided along with an adjacent 34 sqm weightlifting room on the NW side. The rest will
accommodate the hallway and stairs. The second floor will maximize the allowable building footprint.
The architect is expected to satisfy the needs and requirements of the family, considering the
requirements of the code and the subdivision.
Note: this is a timed quiz. You may check the remaining time you have at any point while taking the quiz
by pressing the keyboard combination SHIFT, ALT, and T... Again: SHIFT, ALT, and T...
Question 1
Problem # 1: Based on project given data, what is the Allowable Maximum Building footprint of the
project?
104 sqm
120 sqm
52 sqm
140 sqm
Question 2
Problem # 1: Base on project given data, what is the building footprint of each unit?
104 sqm
120 sqm
52 sqm
62 sqm
Question 3
Lot 2
Lot 4
Lot 3
RROW
Question 4
Split-type
Floor-mounted
Centralized
Window-type
question 5
Problem # 1: Base on project given data, what is the highest elevation of the lot?
1m
2m
0.94m
1.5m
Question 6
Problem # 1: Base on project given data, what is the acquired floor area of second floor?
104 sqm
120 sqm
52 sqm
100 sqm
Question 7
90 x 210 cm
150 x 210 cm
100 x210 cm
75 x 210 cm
Question 8
90 x 210 cm
135 x 210 cm
180 x 210 cm
210 x 210 cm
Question 9
90 x 210 cm
100 x 210 cm
180 x 210 cm
135 x 210 cm
Question 10
Problem # 1: For kitchen storage, what will be the maximum height of wall shelving?
160 cm
90 cm
180 cm
145 cm
Question 11
Problem # 1: How many septic tank should be provided for the lot?
1 unit
2 units
1.5 unit
Question 12
Problem # 1: Given a masonry wall at the ground floor with 2.8 meters high and 4 meters wide, how
many 100mm thick concrete hollow blocks needs to be ordered? Consider 5% wastage factor.
210 pcs
147 pcs
190 pcs
162 pcs
Question 13
Problem # 1: Interior walls are to be painted. Paint with an anti-bacterial formulation that prevents the
growth of bacteria would be utilized. Which from the following qualities does not match the paint
needed?
Almost no odor
Question 14
Problem # 1: Considering a 20sqm room, approximately how much horsepower (HP) of air-conditioning
is ideal considering 12-15sqm = 1 HP?
1.5 HP
2 HP
3 HP
It doesn't matter
Question 15
Question 16
Problem # 1: Base on Rule VII & VIII of National Building Code, what is the Maximum Allowable PSO for
the project?
55%
60%
70%
80%
Question 17
Problem # 1: Base on Rule VII & VIII of National Building Code, what is the Maximum ISA for the project?
36 sqm
72 sqm
120 sqm
64 sqm
Problem # 1: Base on project given data, how many percent of front yard have been paved?
60%
40%
100%
75%
Question 19
Problem # 1: Base on Rule VII & VIII of National Building Code, what is the Minimum USA for the project?
18sqm
12sqm
36 sqm
24 sqm
Question 20
cantilever beam
overhanging beam
intermediate beam
continuous beam
Question 21
Problem # 1: Base on project given data, compute for the longest span of longspan GI roof sheets to be
ordered if the project has 1.2m eaves and a 2.1m height Hip roof.
6.55m
7.2m
6.20m
8.65m
Question 22
Problem # 1: It refers to the portion of the RROW reckoned from the finished surface of the roadway
and/or the sidewalk all the way down into the ground.
RROW at grade
Problem # 1: Subject to existing laws and regulations, who shall determine which street shall have an
open sidewalk or an arcaded (covered) sidewalk, or a combination of both?
Architect
Civil Engineer
Mayor
Question 24
Problem # 1: Which of the following is not covered in the framework of minimum standards and
requirements for buildings under PD 1096?
Aesthetic Value
Maintenance
Material Quality
Location
Question 25
Problem # 1: In a building frame, a structural element that is shorter than usual, as a stud above a door
opening or below a windowsill is
Wood stud
stirrup
scarf joint
cripple stud
Question 26
Problem # 1: In concealed construction, a material or member which fills or seals the open.
insulation
draftstop
tailpiece
backpan
Question 27
Problem # 1: Which of the given elements is NOT part of Architectural Interior Servicesby the Architect?
Question 28
Problem # 1: This design variable refers to materials and construction; thermal insulation; surface
qualities; shading and sun control.
Building Fabric
Fenestration
Air-tightness
Building shape
Question 29
Problem # 1: An incomplete form of peeling where the paint cracks into the large segments, the edges
of which breakaway from the surface while the center remains attached. Usually due to repeated
application of new coats over old coats.
Bistering
Alligatoring
Chalking
Deadening
Question 30
Problem # 1: A type of glass use in constructing vision door which must be shutter proof to be accident
free.
Glass block
Laminated Glass
Wire Glass
Pattern glass
Question 31
2592 ha.
2592 sqm
2592 sqm.
2592 hectares
Question 32
R-2 basic
R-1
R-3 maximum
C-3
Question 33
Problem # 2: If the businessman really wants to maximize the development of the lot, what is the
maximum number of floors
he can construct?
10
12
60
Question 34
Problem # 2: What is the the minimum front setback on the 4th level in meters?
Question 35
Problem # 2: What is the approximate area of the roof deck in square meters?
158
195
325
270
Question 36
Problem # 2: What is the best location of lights for activities in front of the bathroom mirror?
On the sides
Below the mirror
Problem # 2: What color of bathroom light is ideal for make-up application and which mimics outdoor
conditions?
Warm light
Daylight
Neutral
Very warm
Ancillary Permit
Accessory Permit
Building Permit
Mayor's Permit
Problem #2: Which of the following windows are usually installed in basements to admit both air and
light?
Awning window
Casement Window
Hopper window
Jalousie window
Problem #2: Which type is installed if different color temperature is desired in a single lamp?
Fluorescent
Incandescent
Metal Halide
LED
Problem #2: What is the approximate height of the north side of the property in relation to the sidewalk?
Group of answer choices
+0.54m
-0.54m
+0.45m
-0.45m
Problem #2: What is the maximum rear firewall if one is desired for this project?
12.0
16.2
13.5
18.5
Flag question: Question 43
Problem #2: What is the minimum unpaved open space for this project using Table VIII.1?
44 sqm
35 sqm
50 sqm
27 sqm
Problem #2: What is the area provided for parking in this project?
45 sqm
120 sqm
75 sqm
50 sqm
TLA = BF + TOSL
Problem #2: What is the minimum ceiling height required on the 4th level if naturally ventilated?
Group of answer choices
2.1m
2.4m
2.7m
1.8m
Problem #2: What is the building use or occupancy group of this project?
Division A-1
Division A-2
Division B-1
Division C-1
Problem #2: How many occupancy division subgroups are there in the building code?
20
22
25
27
Problem #2: What should be the minimum area for apartment rooms for this project if the ceiling height
is 2.7m?
Group of answer choices
25 sqm
84 sqm
14 sqm
32 sqm
Problem #2: How many parking car slots is required for this project?
3
Flag question: Question 51
Problem #2: What is the typical height of the soffit of wall cabinets above the kitchen countertop?
500mm
600mm
450mm
300mm
Problem #2: Which type of lighting is good for large indoor areas such as parking lots and arenas?
Fluorescent lamps
Arbitrary
Globe
Linear
PAR
Blue
Violet
Red
Black
Problem #2: A window 2m high can allow light ________ from the wall?
3 to 7 m
3 to 5 m
3 to 4 m
3 to 10
Problem #2: Which of the following methods of daylighting means two sidewalls have opposite window
openings?
Unilateral
Bilateral
Sawtooth
Clerestory
Problem #2: Which of the following describes the specifications of a particular product?
Group of answer choices
Mill certificate
Cut sheet
Installation sheet
Warranty
300mm
450mm
600mm
200mm
Problem #2: What do you call a horizontal light fixture attached to a wall and usually shielded from eye?
Cove lighting
Accent lighting
Valence lighting
Decorative lighting
Problem #2: What is the ideal color temperature in a dining table pendant light?
Group of answer choices
Cool
Neutral
Daylight
Warm
Problem #3: What is the approximate area of the front yard of this project?
64 sqm
110 sqm
160 sqm
30 sqm
Problem #3: What is the area of the provided ISA for this project?
33 sqm
15 sqm
48 sqm
30 sqm
275 sqm
415 sqm
375 sqm
163 sqm
218 sqm
375 sqm
155 sqm
Flag question: Question 65
Problem #3: Under Rule VIII Table VIII.1, what is the maximum allowable paved open spaces for this
project?
160 sqm
58 sqm
157 sqm
113 sqm
Problem #3: What is the maximum length of side firewalls allowed for this project?
0% of the side
Task lighting
Accent lighting
Decorative lighting
Ambient lighting
Vinyl planks
Carpeting
Linoleum
Rubber flooring
Problem #3: Which of the following flooring is NOT ideal for the woodworking room?
Ceramic tiles
Polished concrete
Epoxy coated
Resin flooring
Ceramic cornice
Marble baseboard
Gasoline pipes
Fire sprinkler
Problem #3: Using NBCP, what is minimum depth a car parking slot for this project?
5.50 m
5.00 m
2.50 m
6.00 m
Question 73
Living room
Workshop
Carport
Hallway
Question 74
Problem #3: Considering the minimum air space per person, how many estimated persons are allowed
to be in the provided woodworking area if the ceiling height is 3.0 meters?
Question 75
Problem #3: Under NBCP, what is the maximum number of storeys for this project?
Question 76
Problem #3: Which of the following is not involved the work triangle in a kitchen?
Stove
Sink
Dishwater
Refrigerator
Question 77
Problem #3: What is the minimum total length of the optimum kitchen work triangle?
13ft
26ft
5ft
9ft
Question 78
Peninsula
U-shaped
L-shaped
Island
Question 79
Problem #3: What is installed in the faucet to prevent splashing of the water stream?
Angle Valve
Sink plug
Softener
Aerator
Question 80
Problem #3: What is the maximum total length of the optimum kitchen work triangle?
13ft
26ft
5ft
9ft