EN 50600 Standards For Data Centres - and Their International Implementation
EN 50600 Standards For Data Centres - and Their International Implementation
Layer One
Greece
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Mike Gilmore
Standards Activities
EN 50600 standards
for data centres Member
- JTC1 SC25 WG3: “Generic Cabling”
and their
international Member
implementation JTC1 SC39: “Sustainability by and for IT”
Data centres - Design and Resource Efficiency KPIs
Chairman
TC215
Electrotechnical Aspects of Telecommunication Equipment
Convenor
TC215 WG1: Cabling design
Meeting Secretary
Mike Gilmore, FIET
TC215 WG2: Cabling installation - QA and installation practices
Member
Managing Director
TC215 WG3: Facilities and infrastructures (data centres)
e-Ready Building Limited
Member
CEN/CLC/ETSI CG Green Data Centres
Mobile:
+44 (0)786 011 0563 Past-Chairman
e-mail: TCT/7: Telecommunications - Installation Requirements
mike.gilmore Chairman
@ TCT/7/1: Cabling: Infrastructure design, planning and commissioning
e-readybuilding.com Meeting Secretary
TCT/7/2: Cabling; Installation and UK implementation
FIA e-mail: TCT/7/3: Facilities and infrastructures
[email protected]
Layer One
Greece Fibreoptic Industry Association Director
www.fia-online.co.uk standards@fia
6th October 2017
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
The Green Data Centre Coordination Group
CEN CENELEC (CLC) ETSI
EN 50600 standards European Committee European Committee European
for Standardization for Electrotechnical Telecommunications
for data centres Standardization Standardis Insitute
-
and their
international
implementation CEN-CENELEC-ETSI
CO-ORDINATION GROUP
GREEN DATA CENTRES
STATUS REPORT
An in-depth mapping of the
standardisation demands of
energy efficient and sustainable
data centres
BROCHURE
Primary objectives:
A “laymans” guide to
• provide basic definitions
the standardisation
• differentiate types of deliverable
• product, design, operation actions to support the
• define topic boundaries delivery of energy
• map existing deliverables efficient and sustainable
• identify opportunities data centres
• minimise duplication
• within ESOs and ISO/IEC
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
What is a Data Centre?
Data
Data Data
Data
not restricted to
allows data centres inside other types of premises
dedicated premises
not restricted to buildings allows caves, containers etc.
Layer One
Greece
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Standardisation - CENELEC
DESIGN
OPERATION
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Standardisation - CENELEC
Layer One
Greece
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Certification
EN 50600-3-1:2016
Standards bodies are not in a position to judge whether or not an organization offering
certification meets the underlying requirements - that is the role of accreditation specialists.
Some standards such as ISO 9001 and ISO 27001 are written specifically to enable a formal
certification by a 3rd Party body.
Standards in the EN 50600 series do not define the appropriate procedure, leaving this to bilateral
Layer One
contracts or even national or regional legislation to define a process of certification.
Greece
At the time of writing no such process has been defined and there are no accreditation bodies
6th October 2017
associated within standard.
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Why CLC/TR 50600-99-3?
A data centre “owner” under a systems management process (e.g. ISO 27000), who uses EN
50600-3-1 in a management process.
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Data Centre Design Standardisation
Energy efficiency
Availability Physical security
enablement
Protection against
• unauthorised access
• internal fire
• other internal environmental events
• external environmental events
Layer One
Greece
EN 50600-2-x Design standards
6th October 2017
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
International Relationships - Status
EN 50600 standards CLC TC215 WG3 ISO/IEC JTC1 SC39 WG1 AND WG3
for data centres
-
and their
international
implementation EN 50600-1:2012 General concepts ISO/IEC TS 22237-1: 2019
DESIGN
OPERATION
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Key Performance Indicators
TECHNICAL KPIs
EN 50600 standards
for data centres ... assessing energy consumption for a number of specific operating conditions and also across a
- combination of such operating conditions
and their
international Assuming those operating conditions reflect the probable operating environment .. a customer may
implementation make valued judgements in relation to the appropriateness of the Technical KPI
For example, a design of power supply that is more task efficient under high load conditions may be
inappropriate for users who plan to predominantly operate under low load conditions (and vice versa)
OBJECTIVE KPIs
... relate to specific elements of energy management for operational infrastructures including:
energy consumption, task efficiency, energy re-use and renewable energy
... define requirements for the measurement of operational infrastructures i.e. taking into account the
real operating conditions over a defined period of time
GLOBAL KPIs
Objective KPIs... may be combined using a formula appropriate to the specific operational
infrastructure to produce one or more Global operational KPIs which reflects the overall performance
of the operational infrastructures against wider energy management targets
...which may be self-imposed by the operators or externally applied by legislators
Layer One
Greece
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
International Relationships - KPIs
EN 50600 standards CLC TC215 WG3 ISO/IEC JTC1 SC39 WG1 AND WG3
for data centres
- Defining measurement methods - NOT performance requirements
and their
international Influenced by design and operation of data centres
implementation -
but not linked to any standards for design or operation
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Summary
EN 50600 standards
CENELEC TC215
for data centres
- committed to priducing an integrated set of documents
and their (both European Norms and Techncial Reports)
international for the
implementation DESIGN, OPERATION AND RESOURCE EFFICIENCY OF
all types and scales of
DATA CENTRES
50600 SERIES
CONFORMANCE
-
NOT CERTIFICATION
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721
Close
EN 50600 standards
for data centres
-
and their
international
implementation
EN 50600 standards for data centres
-
and their international implementation
Layer One
Greece
www.it-cabling.com www.e-readybuilding.com
© 2017 e-Ready Building Limited P. O. Box MT65, LEEDS, LS17 8YD. United Kingdom Tel: +44 (0) 113 232 3721