KCA Laboratories +1-833-KCA-LABS Certificate of Analysis
232 North Plaza Drive https://kcalabs.com
Nicholasville, KY 40356 KDA Lic.# P_0058
1 of 1
HHCCC-051922
Sample ID: SA-220525-9449
Batch: Received: 05/25/2022
Type: In-Process Materials Completed: 06/07/2022
Matrix: Concentrate - Distillate
Unit Mass (g):
Summary
Test Date Tested Status
Cannabinoids 06/07/2022 Tested
ND 74.4 % 95.8 % Not Tested Not Tested Yes
Total Δ9-THC (6aR,9R,10aR)-HHC Total Cannabinoids Moisture Content Foreign Matter Internal Standard
Normalization
Cannabinoids by HPLC-PDA, LC-MS/MS, and/or GC-MS/MS
LOD LOQ Result Result
Analyte
(%) (%) (%) (mg/g)
CBC 0.0095 0.0284 ND ND
CBCA 0.0181 0.0543 ND ND
CBCV 0.006 0.018 ND ND
CBD 0.0081 0.0242 ND ND
CBDA 0.0043 0.013 ND ND
CBDV 0.0061 0.0182 ND ND
CBDVA 0.0021 0.0063 ND ND
CBG 0.0057 0.0172 ND ND
CBGA 0.0049 0.0147 ND ND
CBL 0.0112 0.0335 ND ND
CBLA 0.0124 0.0371 ND ND
CBN 0.0056 0.0169 0.177 1.77
CBNA 0.006 0.0181 ND ND
CBT 0.0018 0.0054 0.137 1.37
Δ8-THC 0.0104 0.0312 ND ND
Δ9-THC 0.0076 0.0227 ND ND
Δ9-THCA 0.0084 0.0251 ND ND
Δ9-THCV 0.0069 0.0206 ND ND
Δ9-THCVA 0.0062 0.0186 ND ND
(6aR,9R,10aR)-HHC 0.0067 0.02 74.4 744
(6aR,9S,10aR)-HHC 0.0067 0.02 21.1 211
Total Δ9-THC ND ND
Total CBD ND ND
Total 95.8 958
ND = Not Detected; NT = Not Tested; LOD = Limit of Detection; LOQ = Limit of Quantitation; RL = Reporting Limit; Δ = Delta; Total Δ9-THC = Δ9-THCA * 0.877 + Δ9-THC; Total CBD = CBDA * 0.877 + CBD;
Generated By: Ryan Bellone Tested By: Scott Caudill
Commercial Director Senior Scientist
Date: 06/07/2022 Date: 06/07/2022
This product or substance has been tested by KCA Laboratories using validated testing methodologies and an ISO/IEC 17025:2017 accredited quality system. Values reported relate only to the product or substance
tested. The reported result is based on a sample weight. Unless otherwise stated, results of tests performed on all quality control samples met criteria for acceptance established by KCA Laboratories. KCA
Laboratories makes no claims as to the efficacy, safety or other risks associated with any detected or non-detected amounts of any substances reported herein. This Certificate of Analysis shall not be reproduced
except in full, without the written approval of KCA Laboratories. KCA Laboratories can provide measurement uncertainty upon request.