HIGH PRESSURE BALL VALVES
Ball Valve Locking Devices
Description
In situations where the opening or closing of a ball valve can
cause severe damage or personal injury, HYDAC recommends the
installation of a locking device. Locking devices are available for our
entire range of high pressure ball valves. Two different styles are
available to accommodate the different valve body styles. All HYDAC
high pressure ball valves can be ordered with a locking device.
Locking devices can also be ordered separately using the chart
below.
Material note: All lock plates and lock bars are made of
Zinc plated Steel.
Operation
KHM... KHB..., KHP..., KH3..., KH4..., KHB3K...
(forged valve bodies) (block valve bodies)
C
LO
LO
OPEN CLOSED
SE LO
SE LO
D SE
D SE
C
C
OPEN CLOSED
D O
D
PE
N
O
PE
N
Apply Pad Lock (not supplied) Apply Pad Lock (not supplied) Apply Pad Lock (not supplied) Apply Pad Lock (not supplied)
here to lock in OPEN Postition here to lock in CLOSED Postition here to lock in OPEN Postition here to lock in CLOSED Postition
Apply Pad Lock (not supplied) Apply Pad Lock (not supplied) Apply Pad Lock (not supplied) Apply Pad Lock (not supplied)
here to lock in OPEN Postition here to lock in CLOSED Postition here to lock in OPEN Postition here to lock in CLOSED Postition
Installation
Ordering
To order a ball valve with a locking device, simply add “-L” to the end of the model code. See the model code page for that particular valve to
create a complete code. To order a locking device separately, use the chart below.
Size KHB KHM KHP KH3 & KH4 KHB3K
6 02061169 02061169 N/A 02061172 02061175
10 02061169 02061169 02061169 02061173 02061175
12 N/A N/A N/A 02061173 N/A
16 02061170 02061170 02061170 N/A 02061176
20 02061171 02061171 02061171 02061174 02061177
25 02061171 02061171 02061171 N/A 02061177
32 N/A 02055711 02063434 N/A N/A
40 N/A 02055711 02063434 N/A N/A
50 N/A 02055711 02063434 N/A N/A
A1-22 PN#02080105 / 01.17 / ACC1603-1753
HIGH PRESSURE BALL VALVES
Ball Valve Locking Devices with Limit Switches
Description:
When remote indication of the valve position is required, a limit switch
can be added to the valve assembly.
• A reliable single pole, double throw (SPDT) switch to indicate
either open or closed position of a two-way valve
• Hermetically sealed
• Can be wired as Normally Open (N/O), or Normally Closed (N/C)
• Available for HYDAC valve sizes 20 through 50
• Mounting brackets serve as locking devices
Ordering:
To order a valve with limit switch, add “-LS” to the end of the valve
Model Code, i.e.: KHM-32NPT-1114-16X-LS
Operation
KHB..., KHP..., KH3..., KH4..., KHB3K... (block valve bodies, sizes 20 & 25) Valve Retrofit kit
Part #: 02067694
KHM... (forged valve bodies, sizes 32 through 50)
Valve Retrofit kit
Part #: 02063537
Wiring Details Electrical Specifications
• NEMA 3, 4, 13 and IEC IP 67 Replacement Switch
• 5A- up to 250 VAC, 30 VDC Part #: 02700009
• Temperature range: 14 to 158˚F
• UL listed
PN#02080105 / 01.17 / ACC1603-1753 A1-23