Manual - WAS100 (R1) Anemometer
Manual - WAS100 (R1) Anemometer
User Manual
Model : AC-WAS100(R1)
-Contents-
1. General
2. Specification
2.1 Technical specification 2.2 Electric specification
3. Configuration
4. Communication
5. Electrical Connections
6. System Configuration
7. Display Window
7.1 Booting 7.2 ANE View
7.3 Plot View 7.4 Data View
7.5 Setup 7.6 Information
8. Data View & Delete, Saving
8.1 Data view 8.2 Data delete
8.3 Data saving
9. Operation ‘Setup’
9.1 ANE Setup 9.2 System Environment
9.3 Date & Time Setup
10. Accessories
11. Caution
12. Troubleshoot
13. Dimensions
13.1 Dimensions 13.2 Cutting hole
-2-
1. General
Wind alarm panel is the equipment to meet Exxon-mobile 2017 rule requirement such as
MESQAC 2017 (Marine Environmental Safety and Quality Assurance Criteria for Tanker Vessels)
ExxonMobil E17/E1a: Vessels MUST be fitted with an anemometer Display /Monitoring Repeater
in the record (paper or digital) wind speed and direction, and designed to be capable of setting
a minimum speed limits with Audible/Visual Alarms in the CCR and on Deck if the set limits are
exceeded.
The equipment for suspension a unloading work with alarming against winding beyond setting
result when anchoring and unloading cargo oil or gas. It gets alarmed from wind alarm panel
in the cargo control room of the vessel inside and the incurred alarm warning is recognized
through the electric horn installed inside and on deck side.
2. Specification
2.1 Technical Specification
ITEM SPECIFICATION
0 – 70 m/s
Wind speed range
0 – 136 Knots
About 5 years
Data storage period
(16Gbyte, 32,000,000 data)
Paper output
Data output
(DATE,TIME,SPEED,DIRECTION)
-3-
2.2 Electric Specification
ELECTRIC SPECIFICATION
Operating Temp. 5 – 55 ℃
Storage Temp. 0 – 60 ℃
Humidity 0 – 95 %
Communication NMEA0183
7 inch LCD(800*480) /
Display & Touch
RESISTIVE TOUCH SCREEN
MACHANICAL SPECIFICATION
Front cover AL
Name Plate PC
-4-
3. Configuration
-5-
4. Communication
NMEA, NMEA 0183 is the standard for transmitting information such as time, location.
NMEA 0183 is determined on National Marine Electronics Association and use a serial bus
communication, ASCII code.
-6-
4.2 ZDA – Local Date & Time
-7-
5. Electrical connections
5.1 AC-WAS100(R1) connection
-8-
6. System Configuration
-9-
7. Display Window
7.1 Booting Display
-10-
7.2 ANE View
In the top menu, when you press the button, the above display is
shown.
User can see the wind speed and direction information from anemometer.
1) The unit / alarm limit / direction mode / vessel statue. Etc, are able to set on
‘Setup’ menu and re-boot, the setting is applied. The details can be found
on Section 9 Operating Setup.
-11-
2) Display example
a. Relative type & Anchorage mode, m/sec, UTC display
-12-
c. True type & Anchorage mode, m/sec, DGPS display(※Option)
-13-
7.3 Plot View
In the top menu, when you press the button, the above display is
shown.
It shows that the wind speed and direction information from Anemometer in
data over time shortly.
1) Yellow bar( ) means wind speed. User can see the data during on 5
mins as plot form, the each point is 1 sec.
2) Green bar( ) means wind direction, User can see the data on right
screen as vertical graph.
-14-
3) Display example
a. Relative type & m/sec, UTC display
-15-
c. True type & m/sec, UTC display(※Option)
-16-
7.4 Data View
If select the certain date, user can see the alarm list occurred alarm on the date.
If there is no alarm on the date, the list is empty as the below picture.
-17-
7.5 Set-Up
-18-
7.6 Information
-19-
8. Data View & Delete, Saving
8.1 Data view
When press button, you can see the Data view display.
If user needs a history of high alarm and high high alarm on certain date, click
the button and select the date.
After 1~2 sec, The list of alarm would be shown in sequence of time.
-20-
Press this button, it is able to check the previous page.
-21-
8.2 Data delete
1). Delete the alarm list that had been occurred before 1 year.
a. Press the button, user can see the below display.
-22-
8.3 Data View Refresh
1). Refresh the History List of Wind Speed Alarm
a. When press , user can see the below display.
Input the password ‘2000’ and press the , Now, the system
starts re-booting.
-23-
9. Operation “Setup”
Input the set value and press OK! Button, And then, press
, it is applied to system,
-24-
3). Set High-high Alarm
In the Setup, press the of
The dialog is shown as below.
Input the set value and press OK! Button, And then, press
it is applied to system,
Input the set value and press OK! Button, And then, press
, it is applied to system,
-25-
9.2 System Environment
2). Manager Mode! : This mode is for modifying DATE, TIME, special set for system.
The details can be found on Section 9.3.
3). Setup Save : It is for saving the change of set. If there is any change on set,
User should press this for applying it to system.
-27-
9.3 Date_Time Update
※ ATTENTION : This mode affects seriously to whole system, so, please
operate this mode only for special situation.
Input the password 2000, and OK! button. Next, user can see the below display.
-28-
2) It is able to change the year, month, date, hour, minute, second when click
each part.
Click the each part of year, month etc, and set value as
3) And please save the set as press the button.
-29-
10. Accessories
Accessories of wind alarm panel are installed outside of the vessel, which has
electric horn that sailors can recognize an alarm for wind speed beyond
setting result. There is a manual for electric horn separately so please refer
to the manual. Two electric horns are installed in PORT and STBD on deck
side each to listen an alarm in both sides.
11. Caution
① Touch screen is easy to be damaged so, do not touch it as anything sharp
and do not give any shock.
-36-
12. Troubleshoot
After checking
communication cable,
reboot with power on-off.
The screen is freezing. Communication cable is not Reboot with power on-off
connection with. after checking
communication cable
connection.
Error program based on Reboot with power on-off.
window.
Printer is not operated. No paper in printer. Exchange a paper with
opening cover of printer.
Disable to print out. Reinstall the paper with
opening cover of printer.
Red LED is lighting. Recommend to repair the
printer or replace it.
Electric horn is not ring. Not connected with terminal Check cable condition.
block electric horn cable.
DC24V is not output when Recommend to repair the
back of alarm panel of wind alarm system.
electric horn’s connection
terminal block is alarmed by
multi tester.
If the horn is not ring when Recommend to check
the DC24V is output electric horn own.
normally from alarm panel.
It’s not work due to error on System error Reboot with power on-off.
screen.
in case it’s not work after
trying reboot, Install the
program again referring to 9.4
Program update
The front of buzzer or buzzer Buzzer or buzzer stop switch Recommend to repair.
stop switch is not work. trouble.
-37-
13. Dimensions
13.1 Dimension
-38-
13.2 Cutting hole
Website: http://www.heriana.com