Energy Building Duct Layout

The document provides details of the dimensions, lengths, and insulation for various areas in an energy building with 3 basement levels. It includes specifications for lift lobbies, stairwells, fan zones, and other areas. Dimensions include length, width, thickness. Insulation quantities and types are specified for each area. The goal is to optimize energy efficiency and insulation for the building.

Uploaded by

Kaushal Mistry
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views82 pages

Energy Building Duct Layout

The document provides details of the dimensions, lengths, and insulation for various areas in an energy building with 3 basement levels. It includes specifications for lift lobbies, stairwells, fan zones, and other areas. Dimensions include length, width, thickness. Insulation quantities and types are specified for each area. The goal is to optimize energy efficiency and insulation for the building.

Uploaded by

Kaushal Mistry
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

ENERGY BUILDING 1

Sl. Dimensions LENGTH


Description

No. A1 B1 A2 B2 Mts
mm. mm. mm. mm.
BASEMENT 01
1 LIFT LOBBY - LEFT 750 400 5
750 400 15
Diffuser Connection 450 450 1.0

2 LIFT LOBBY - RIGHT 750 400 5


750 400 15
Diffuser Connection 450 450 1.0

1 STR PRESS. 01 900 450 11


2500 500 1
2 STR PRESS. 02 900 450 11
2500 500 1
3 STR PRESS. 03 700 600 16
2500 500 1
4 STR PRESS. 04 700 600 16
hp11:
2500 500 1
Duct assumed 24000 CFM
at 2000 FPM
1 Zone 1 - FA Fan 1100 1100 2
2 Zone 1 - EA Fan 1100 hp11:
1100 2
Duct assumed 24000 CFM
at 2000 FPM
1 Zone 2 - FA Fan 1100 1100 2
2 Zone 2 - EA Fan 1100 hp11:
1100 2
Duct assumed 24000 CFM
at 2000 FPM
1 Zone 3 - FA Fan 1100 1100 2
2 Zone 3 - EA Fan 1100 1100 2

TOTAL
BASEMENT 02
1 LIFT LOBBY - LEFT 750 400 5
750 400 15
Diffuser Connection 450 450 1.0

2 LIFT LOBBY - RIGHT 750 400 5


750 400 15
Diffuser Connection 450 450
hp11: 1.0
Duct assumed 24000 CFM
1 Zone 1 - FA Fan 1100 at 2000 FPM
1100 2
2 Zone 1 - EA Fan 1100 1100
hp11: 2
Duct assumed 24000 CFM
1 Zone 2 - FA Fan 1100 1100
at 2000 FPM 2
2 Zone 2 - EA Fan 1100 1100 2
hp11:
Duct assumed 24000 CFM
1 Zone 3 - FA Fan 1100 1100
at 2000 FPM 2
2 Zone 3 - EA Fan 1100 1100 2
hp11:
Considered tentatively.
2 Bottle wash 50% of 1 wing ofc floor
TOTAL ducting is considered
BASEMENT 03
1 LIFT LOBBY - LEFT 750 400 5
750 400 15
Diffuser Connection 450 450 1.0

2 LIFT LOBBY - RIGHT 750 400 5


750 400 15
Diffuser Connection 450 450 1.0
hp11:
1 Zone 1 - FA Fan 1100 Duct
1100assumed 24000 CFM 2
at 2000 FPM
2 Zone 1 - EA Fan 1100 1100 2
hp11:
1 Zone 2 - FA Fan 1100 1100assumed 24000 CFM
Duct 2
2 Zone 2 - EA Fan 1100 at 2000 FPM
1100 2

1 Zone 3 - FA Fan 1100 hp11:


1100 2
2 Zone 3 - EA Fan 1100 Duct
1100assumed 24000 CFM 2
at 2000 FPM

TOTAL
ENERGY BUILDING 1

Insulation
QTY (Thermal/ MAX AREA AREA(Sq mts.) Accoustic
Accoustic)

Nos (mm) SQ MT 24 G 22 G 20 G 18 G Insulation

1 1.0 750 11.5 11.5 0.0 0.0 0.0 11.5


1 2.0 750 34.5 34.5 0.0 0.0 0.0 0.0
6 2.0 450 10.8 10.8 0.0 0.0 0.0 0.0

1 1.0 750 11.5 11.5 0.0 0.0 0.0 11.5


1 2.0 750 34.5 34.5 0.0 0.0 0.0 0.0
6 2.0 450 10.8 10.8 0.0 0.0 0.0 0.0

1 900 29.7 0.0 29.7 0.0 0.0 0.0


1 2500 6.0 0.0 0.0 0.0 6.0 0.0
1 900 29.7 0.0 29.7 0.0 0.0 0.0
1 2500 6.0 0.0 0.0 0.0 6.0 0.0
1 700 41.6 41.6 0.0 0.0 0.0 0.0
1 2500 6.0 0.0 0.0 0.0 6.0 0.0
1 700 41.6 41.6 0.0 0.0 0.0 0.0
1 2500 6.0 0.0 0.0 0.0 6.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

196.8 270.6 0.0 24.0 23.0

1 1.0 750 11.5 11.5 0.0 0.0 0.0 11.5


1 2.0 750 34.5 34.5 0.0 0.0 0.0 0.0
6 2.0 450 10.8 10.8 0.0 0.0 0.0 0.0

1 1.0 750 11.5 11.5 0.0 0.0 0.0 11.5


1 2.0 750 34.5 34.5 0.0 0.0 0.0 0.0
6 2.0 450 10.8 10.8 0.0 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

0 0.0 378 90 0.0 0.0 0.0


491.4 300.9 0.0 0.0 23.0

1 1.0 750 11.5 11.5 0.0 0.0 0.0 11.5


1 2.0 750 34.5 34.5 0.0 0.0 0.0 0.0
6 2.0 450 10.8 10.8 0.0 0.0 0.0 0.0

1 1.0 750 11.5 11.5 0.0 0.0 0.0 11.5


1 2.0 750 34.5 34.5 0.0 0.0 0.0 0.0
6 2.0 450 10.8 10.8 0.0 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

4 1100 35.2 0.0 35.2 0.0 0.0 0.0


4 1100 35.2 0.0 35.2 0.0 0.0 0.0

113.6 211.2 0.0 0.0 23.0


Thermal Sl. Dimensions
Description

Insulation No. A1 B1 A2
mm. mm. mm.
BASEMENT 01
0.0 1 LIFT LOBBY - LEFT 750 400
34.5 750 400
10.8 Diffuser Connection 450 450

0.0 2 LIFT LOBBY - RIGHT 750 400


34.5 750 400
10.8 Diffuser Connection 450 450

0.0 1 STR PRESS. 01 900 450


0.0 2500 500
0.0 2 STR PRESS. 02 900 450
0.0 2500 500
0.0 3 STR PRESS. 03 700 600
0.0 2500 500
0.0 4 STR PRESS. 04 hp11:
700 600
tentative
0.0 2500 500

0.0 1 Kitchen BOH


0.0
1 Zone 4 - FA Fan 1100 1100
0.0 2 Zone 4 - EA Fan 1100 1100
0.0
1 Zone 5 - FA Fan 1100 1100
0.0 2 Zone 5 - EA Fan 1100 1100
0.0
1 Zone 6 - FA Fan 1100 1100
90.6 2 Zone 6 - EA Fan 1100 1100
hp11:
Duct assumed 24000 CFM at
0.0 TOTAL 2000 FPM
34.5 BASEMENT 02
10.8 1 LIFT LOBBY - LEFT hp11: 750 400
Duct assumed 24000 CFM at
750 400
2000 FPM
0.0 Diffuser Connection 450 450
34.5 hp11:
Duct assumed 24000 CFM at
2000 FPM
hp11:
Duct assumed 24000 CFM at
2000 FPM

hp11:
10.8 2 LIFT LOBBY - RIGHT Duct assumed
750 24000400
CFM at
2000 FPM
750 400
0.0 Diffuser Connection 450 450
0.0
1 Zone 4 - FA Fan 1100 1100
0.0 2 Zone 4 - EA Fan 1100 1100
0.0
1 Zone 5 - FA Fan 1100 1100
0.0 2 Zone 5 - EA Fan 1100 1100
0.0
1 Zone 6 - FA Fan 1100 1100
0.0 2 Zone 6 - EA Fan 1100 1100
90.6

0.0 TOTAL
34.5 BASEMENT 03
10.8 1 LIFT LOBBY - LEFT 750 400
750 400
0.0 Diffuser Connection 450 450
34.5
10.8 2 LIFT LOBBY - RIGHT hp11: 750 400
Duct assumed 24000 CFM at
750
2000 FPM
400
0.0 Diffuser Connection 450 450
0.0 hp11:
1 Zone 4 - FA Fan Duct assumed
1100 24000 CFM at
1100
2000 FPM
0.0 2 Zone 4 - EA Fan 1100 1100
0.0 hp11:
1 Zone 5 - FA Fan 1100 24000
Duct assumed 1100
CFM at
0.0 2 Zone 5 - EA Fan 2000 FPM
1100 1100
0.0
1 Zone 6 - FA Fan 1100 1100
90.6 2 Zone 6 - EA Fan 1100 1100

TOTAL

hp11:
Duct assumed 24000 CFM at
2000 FPM

hp11:
hp11:
Duct assumed 24000 CFM at
2000 FPM

hp11:
Duct assumed 24000 CFM at
2000 FPM

hp11:
Duct assumed 24000 CFM at
2000 FPM
ENERGY BUILDING 2

Insulation
nsions LENGTH QTY (Thermal/ MAX AREA AREA(Sq mts.)
Accoustic)

B2 Mts Nos (mm) SQ MT 24 G 22 G 20 G


mm.

5 1 1.0 750 11.5 11.5 0.0 0.0


15 1 2.0 750 34.5 34.5 0.0 0.0
1.0 6 2.0 450 10.8 10.8 0.0 0.0

5 1 1.0 750 11.5 11.5 0.0 0.0


15 1 2.0 750 34.5 34.5 0.0 0.0
1.0 6 2.0 450 10.8 10.8 0.0 0.0

11 1 900 29.7 0.0 29.7 0.0


1 1 2500 6.0 0.0 0.0 0.0
11 1 900 29.7 0.0 29.7 0.0
1 1 2500 6.0 0.0 0.0 0.0
16 1 700 41.6 41.6 0.0 0.0
1 1 2500 6.0 0.0 0.0 0.0
16 1 700 41.6 41.6 0.0 0.0
1 1 2500 6.0 0.0 0.0 0.0

64.4 16.1

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

261.2 286.7 0.0

5 1 1.0 750 11.5 11.5 0.0 0.0


15 1 2.0 750 34.5 34.5 0.0 0.0
1.0 6 2.0 450 10.8 10.8 0.0 0.0
5 1 1.0 750 11.5 11.5 0.0 0.0
15 1 2.0 750 34.5 34.5 0.0 0.0
1.0 6 2.0 450 10.8 10.8 0.0 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

113.6 211.2 0.0

5 1 1.0 750 11.5 11.5 0.0 0.0


15 1 2.0 750 34.5 34.5 0.0 0.0
1.0 6 2.0 450 10.8 10.8 0.0 0.0

5 1 1.0 750 11.5 11.5 0.0 0.0


15 1 2.0 750 34.5 34.5 0.0 0.0
1.0 6 2.0 450 10.8 10.8 0.0 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

2 4 1100 35.2 0.0 35.2 0.0


2 4 1100 35.2 0.0 35.2 0.0

113.6 211.2 0.0


Sq mts.) Accoustic Thermal Sl. Dimensions
Description

18 G Insulation Insulation No. A1


mm.
BASEMENT 01
0.0 11.5 0.0 1 LIFT LOBBY - LEFT 750
0.0 0.0 34.5 750
0.0 0.0 10.8 Diffuser Connection 450

0.0 11.5 0.0 2 LIFT LOBBY - RIGHT 750


0.0 0.0 34.5 750
0.0 0.0 10.8 Diffuser Connection 450

0.0 0.0 0.0 1 STR PRESS. 01 900


6.0 0.0 0.0 2500
0.0 0.0 0.0 2 STR PRESS. 02 900
6.0 0.0 0.0 2500
0.0 0.0 0.0 3 STR PRESS. 03 700
6.0 0.0 0.0 2500
0.0 0.0 0.0 4 STR PRESS. 04 700
6.0 0.0 0.0 2500

10.0 80.5 1 Zone 7 - FA Fan 1100


2 Zone 7 - EA Fan 1100
0.0 0.0 0.0
0.0 0.0 0.0 1 Zone 8 - FA Fan 1100
2 Zone 8 - EA Fan 1100
0.0 0.0 0.0
0.0 0.0 0.0 TOTAL
BASEMENT 02
0.0 0.0 0.0 1 LIFT LOBBY - LEFT 750
0.0 0.0 0.0 750
Diffuser Connection 450
24.0 33.0 171.1
2 LIFT LOBBY - RIGHT 750
hp11:
0.0 11.5 0.0 750
Duct assumed 24000 CFM
0.0 0.0 34.5 Diffuser Connection at 2000 FPM
450
0.0 0.0 10.8
hp11:
1 Zone 7 - FA Fan 1100
Duct assumed 2
hp11: at 2000 FPM
Duct assumed 24000 CFM
at 2000 FPM
hp11:
Duct assumed 2
0.0 11.5 0.0 2 Zone 7 - EA Fan hp11: 1100 at 2000 FPM
0.0 0.0 34.5 Duct assumed 24000 CFM
at 2000 FPM hp11:
0.0 0.0 10.8 1 Zone 8 - FA Fan 1100 Duct assumed 2
2 Zone 8 - EA Fan 1100 at 2000 FPM
0.0 0.0 0.0
0.0 0.0 0.0 TOTAL
BASEMENT 03
0.0 0.0 0.0 1 LIFT LOBBY - LEFT 750
0.0 0.0 0.0 750
Diffuser Connection 450
0.0 0.0 0.0
0.0 0.0 0.0 2 LIFT LOBBY - RIGHT 750
750
Diffuser Connection 450
0.0 23.0 90.6
hp11:
1 Zone 7 - FA Fan 1100
Duct assumed 2
0.0 11.5 0.0 2 Zone 7 - EA Fan 1100 at 2000 FPM
0.0 0.0 34.5
hp11:
0.0 0.0 10.8 1 Zone 8 - FA Fan 1100
Duct assumed 2
2 Zone 8 - EA Fan 1100 at 2000 FPM
0.0 11.5 0.0
0.0 0.0 34.5 TOTAL
0.0 0.0 10.8

0.0 0.0 0.0


0.0 0.0 0.0

0.0 0.0 0.0


0.0 0.0 0.0

0.0 0.0 0.0


0.0 0.0 0.0

0.0 23.0 90.6


ENERGY BUILDING 3

Insulation
Dimensions LENGTH QTY (Thermal MAX AREA AREA(Sq mts.)
/
Accoustic)

B1 A2 B2 Mts Nos (mm) SQ MT 24 G 22 G


mm. mm. mm.

400 5 1 1.0 750 11.5 11.5 0.0


400 15 1 2.0 750 34.5 34.5 0.0
450 1.0 6 2.0 450 10.8 10.8 0.0

400 5 1 1.0 750 11.5 11.5 0.0


400 15 1 2.0 750 34.5 34.5 0.0
450 1.0 6 2.0 450 10.8 10.8 0.0

450 11 1 900 29.7 0.0 29.7


500 1 1 2500 6.0 0.0 0.0
450 11 1 900 29.7 0.0 29.7
500 1 1 2500 6.0 0.0 0.0
600 16 1 700 41.6 41.6 0.0
500 1 1 2500 6.0 0.0 0.0
600 16 1 700 41.6 41.6 0.0
500 1 1 2500 6.0 0.0 0.0

1100 2 4 1100 35.2 0.0 35.2


1100 2 4 1100 35.2 0.0 35.2

1100 2 4 1100 35.2 0.0 35.2


1100 2 4 1100 35.2 0.0 35.2

196.8 200.2

400 5 1 1.0 750 11.5 11.5 0.0


400 15 1 2.0 750 34.5 34.5 0.0
450 1.0 6 2.0 450 10.8 10.8 0.0

400 5 1 1.0 750 11.5 11.5 0.0


1:
400 15 1 2.0 750 34.5 34.5 0.0
assumed 24000 CFM
00 FPM 450 1.0 6 2.0 450 10.8 10.8 0.0

hp11:
1100 2 4 1100 35.2 0.0 35.2
Duct assumed 24000 CFM
1: at 2000 FPM
assumed 24000 CFM
00 FPM
hp11:
Duct assumed 24000 CFM
1: 1100
at 2000 FPM 2 4 1100 35.2 0.0 35.2
assumed 24000 CFM
00 FPM hp11:
1100
Duct assumed 24000 CFM
2 4 1100 35.2 0.0 35.2
1100
at 2000 FPM 2 4 1100 35.2 0.0 35.2

113.6 140.8

400 5 1 1.0 750 11.5 11.5 0.0


400 15 1 2.0 750 34.5 34.5 0.0
450 1.0 6 2.0 450 10.8 10.8 0.0

400 5 1 1.0 750 11.5 11.5 0.0


400 15 1 2.0 750 34.5 34.5 0.0
450 1.0 6 2.0 450 10.8 10.8 0.0

hp11:
1100 2 4 1100 35.2 0.0 35.2
Duct assumed 24000 CFM
1100
at 2000 FPM 2 4 1100 35.2 0.0 35.2

hp11:
1100 2 4 1100 35.2 0.0 35.2
Duct assumed 24000 CFM
1100
at 2000 FPM 2 4 1100 35.2 0.0 35.2

113.6 140.8
AREA(Sq mts.) Accoustic Thermal

20 G 18 G Insulation Insulation

0.0 0.0 11.5 0.0


0.0 0.0 0.0 34.5
0.0 0.0 0.0 10.8

0.0 0.0 11.5 0.0


0.0 0.0 0.0 34.5
0.0 0.0 0.0 10.8

0.0 0.0 0.0 0.0


0.0 6.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 6.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 6.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 6.0 0.0 0.0

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0

0.0 24.0 23.0 90.6

0.0 0.0 11.5 0.0


0.0 0.0 0.0 34.5
0.0 0.0 0.0 10.8

0.0 0.0 11.5 0.0


0.0 0.0 0.0 34.5
0.0 0.0 0.0 10.8

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0

0.0 0.0 23.0 90.6

0.0 0.0 11.5 0.0


0.0 0.0 0.0 34.5
0.0 0.0 0.0 10.8

0.0 0.0 11.5 0.0


0.0 0.0 0.0 34.5
0.0 0.0 0.0 10.8

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0

0.0 0.0 23.0 90.6


ENERGY BUILDING 01
VOLUME CONTROL DAMPERS
SIZE IN mm
SL.NO Location QTY AREA
W D Nos SQ.MT
BASEMENT 01
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30

TOTAL
BASEMENT 02
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30
hp11:
Considered tentatively.
1 Bottle Wash 50% of 1 wing ofc floor
ducting is considered
TOTAL
BASEMENT 03
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30

TOTAL

ENERGY BUILDING 02
VOLUME CONTROL DAMPERS
SIZE IN mm QTY AREA
SL.NO Location
W D Nos SQ.MT
BASEMENT 01
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30

TOTAL
BASEMENT 02
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30
hp11:
Considered tentatively.
50% of 1 wing ofc floor
ducting is considered
hp11:
Considered tentatively.
50% of 1 wing ofc floor
ducting is considered
TOTAL
BASEMENT 03
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30

TOTAL

ENERGY BUILDING 03
VOLUME CONTROL DAMPERS
SIZE IN mm
SL.NO Location QTY AREA
W D Nos SQ.MT
BASEMENT 01
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30

TOTAL
BASEMENT 02
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30
hp11:
Considered tentatively.
50% of 1 wing ofc floor
ducting is considered
TOTAL
BASEMENT 03
1 LIFT LOBBY - LEFT 750 400 1 0.30
2 LIFT LOBBY - RIGHT 750 400 1 0.30

TOTAL
MOTORIZED FIRE DAMPERS
Billing SL.NO LOCATION TERMINAL QTY
Area
SQ.MT WIDTH HEIGHT Nos
BASEMENT 01
0.30 1 STR PRESS. 01 900 450 1
0.30 2 STR PRESS. 02 900 450 1
3 STR PRESS. 03 700 600 1
1 4 STR PRESS. 04 700 600 1

0.30 BASEMENT 01
0.30 1 EXHAUST FAN -ZONE 01 1100 1100 2
2 EXHAUST FAN -ZONE 02 1100 1100 2
2.50 3 EXHAUST FAN -ZONE 03 1100 1100 2
TOTAL
3 BASEMENT 02
1 EXHAUST FAN -ZONE 01 1100 1100 2
0.30 2 EXHAUST FAN -ZONE 02 1100 1100 2
0.30 3 EXHAUST FAN -ZONE 03 1100 1100 2
TOTAL
1 BASEMENT 03
1 EXHAUST FAN -ZONE 01 1100 1100 2
2 EXHAUST FAN -ZONE 02 1100 1100 2
3 EXHAUST FAN -ZONE 03 1100 1100 2
TOTAL

Billing MOTORIZED FIRE DAMPERS


Area SL.NO LOCATION TERMINAL QTY
SQ.MT WIDTH HEIGHT Nos
BASEMENT 01
0.30 1 STR PRESS. 01 900 450 1
0.30 2 STR PRESS. 02 900 450 1
3 STR PRESS. 03 700 600 1
1 4 STR PRESS. 04 700 600 1

0.30 BASEMENT 01
0.30 1 EXHAUST FAN -ZONE 04 1100 1100 2
2 EXHAUST FAN -ZONE 05 1100 1100 2
3 EXHAUST FAN -ZONE 06 1100 1100 2
TOTAL
1 BASEMENT 02
1 EXHAUST FAN -ZONE 04 1100 1100 2
0.30 2 EXHAUST FAN -ZONE 05 1100 1100 2
0.30 3 EXHAUST FAN -ZONE 06 1100 1100 2
TOTAL
1 BASEMENT 03
1 EXHAUST FAN -ZONE 04 1100 1100 2
2 EXHAUST FAN -ZONE 05 1100 1100 2
3 EXHAUST FAN -ZONE 06 1100 1100 2
TOTAL

MOTORIZED FIRE DAMPERS


Billing SL.NO LOCATION TERMINAL QTY
Area
SQ.MT WIDTH HEIGHT Nos
BASEMENT 01
0.30 1 STR PRESS. 01 900 450 1
0.30 2 STR PRESS. 02 900 450 1
3 STR PRESS. 03 700 600 1
1 4 STR PRESS. 04 700 600 1

0.30 BASEMENT 01
0.30 1 EXHAUST FAN -ZONE 07 1100 1100 2
2 EXHAUST FAN -ZONE 08 1100 1100 2

TOTAL
1 BASEMENT 02
1 EXHAUST FAN -ZONE 07 1100 1100 2
0.30 2 EXHAUST FAN -ZONE 08 1100 1100 2
0.30
TOTAL
1 BASEMENT 03
1 EXHAUST FAN -ZONE 07 1100 1100 2
2 EXHAUST FAN -ZONE 08 1100 1100 2

TOTAL
S PRESSURE RELIEF DAMPERS
Billing
AREA SL.NO LOCATION TERMINAL QTY
Area
SQ.MT SQ.MT WIDTH HEIGHT Nos
TERRACE
0.4 0.4
0.4 0.4
0.4 0.4 1 STAIRCASE 1-4 700 700 4
0.4 0.4
TOTAL

1.2 2.4
1.2 2.4
1.2 2.4
9

1.2 2.4
1.2 2.4
1.2 2.4
7

1.2 2.4
1.2 2.4
1.2 2.4
7

S PRESSURE RELIEF DAMPERS


AREA Billing SL.NO LOCATION TERMINAL QTY
Area
SQ.MT SQ.MT WIDTH HEIGHT Nos
TERRACE
0.4 0.4
0.4 0.4
0.4 0.4 1 STAIRCASE 1-4 700 700 4
0.4 0.4
TOTAL

1.2 2.4
1.2 2.4
1.2 2.4
7
1.2 2.4
1.2 2.4
1.2 2.4
7

1.2 2.4
1.2 2.4
1.2 2.4
7

S PRESSURE RELIEF DAMPERS


Billing
AREA SL.NO LOCATION TERMINAL QTY
Area
SQ.MT SQ.MT WIDTH HEIGHT Nos
TERRACE
0.4 0.4
0.4 0.4
0.4 0.4 1 STAIRCASE 1-4 700 700 4
0.4 0.4
TOTAL

1.2 2.4
1.2 2.4

1.2 2.4
1.2 2.4

1.2 2.4
1.2 2.4

5
RS
Billing
AREA
Area
SQ.MT SQ.MT

0.5 2.0

1.96

RS
AREA Billing
Area
SQ.MT SQ.MT

0.5 2.0

1.96
RS
Billing
AREA
Area
SQ.MT SQ.MT

0.5 2.0

1.96
4 WAY - DIFFUSERS
Billing
SL.NO LOCATION SUPPLY QTY AREA
Area
WIDTH HEIGHT Nos SQ.MT SQ.MT
BASEMENT 01
1 LIFT LOBBY - LEFT 450 450 6 0.2 1.2
2 LIFT LOBBY - RIGHT 450 450 6 0.2 1.2
3
BASEMENT 02
1 LIFT LOBBY - LEFT 450 450 6 0.2 1.2
2 LIFT LOBBY - RIGHT 450 450 6 0.2 1.2
3
BASEMENT 03
1 LIFT LOBBY - LEFT 450 450 6 0.2 1.2
2 LIFT LOBBY - RIGHT 450 450 6 0.2 1.2
3
ERS 15 Deg. Sin
Billing
RETURN QTY AREA SL.NO LOCATION SUPPLY
Area
WIDTH HEIGHT Nos SQ.MT SQ.MT WIDTH
BASEMENT 01
450 450 6 0.2 1.2 1 STR PRESS. 01 1800
450 450 6 0.2 1.2 2 STR PRESS. 02 1800
3 3 STR PRESS. 03 600
4 STR PRESS. 04 600
450 450 6 0.2 1.2 E1 - Bottle wash - B2
450 450 6 0.2 1.2 4
3
TOTAL
450 450 6 0.2 1.2
450 450 6 0.2 1.2
3
15 Deg. Single way deflection GRILLES
Billing Billing
SUPPLY QTY AREA RETURN QTY AREA
Area Area
HEIGHT Nos SQ.MT SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

600 1 1.1 1.1


600 1 1.1 1.1
450 1 0.3 0.3
450 1 0.3 0.3

2.7

3
LOUVERS
Billing
SL.NO LOCATION SUPPLY QTY AREA RETURN
Area
WIDTH HEIGHT Nos SQ.MT SQ.MT WIDTH
BASEMENT 01

1 BATTERY ROOM - FA 0.4


2 BATTERY ROOM - EA 0.4

1 BOTTLE WASH 2.3

3
Billing
RETURN QTY AREA
Area
HEIGHT Nos SQ.MT SQ.MT
Sl. Dimensions
Description

No. A1 B1 VCD B2
mm. mm. mm. mm.
LEFT WING AHU
1 MAIN 600 550 1 0.33 0.33
2 MAIN 600 550
3 MAIN 600 550
4 VAV 07 - BRANCH 300 400 1 0.12 0.20
5 SUB BRANCH 400 300
6 300 150
10 COLLAR 600 150

6 VAV 01 - BRANCH 300 250 1 0.08 0.20


7 BRANCH 400 250
8 SUB BRANCH 600 150
9 SUB BRANCH 300 150
10 COLLAR 600 150

11 VAV - 02 BRANCH 400 250 1 0.10 0.20

12 SUB BRANCH 300 200


13 SUB BRANCH 300 250
14 SUB BRANCH 300 200

15 VAV - 03 BRANCH 300 300 1


0.09 0.20
16 400 300

17 VAV - 04 BRANCH 300 300 1 0.09 0.20


18 400 300
19 SUB BRANCH 300 200
10 COLLAR 600 150

20 VAV - 05 BRANCH 300 300 1 0.09 0.20


21 400 300
22 SUB BRANCH 300 200
10 COLLAR 600 150
23 VAV - 06 BRANCH 300 300 1 0.09 0.20
24 400 250
22 SUB BRANCH 300 200
10 COLLAR 600 150

25 ELEC ROOM 600 150 1 0.09 0.20

26 MAIN 1200 550 1 0.66 0.66


27 MAIN 1200 550
28 MAIN 1200 550
29 MAIN 750 550
29 MAIN 600 550
30 MAIN 300 300 1 0.09 0.20
31 VAV 08
32 BRANCH 400 350
33 SUB BRANCH 500 300
34 SUB BRANCH 300 200
35 COLLAR 1200 150

VAV - 9 BRANCH 400 350 1 0.14 0.20


400 350
300 200
COLLAR 1200 150

44 VAV - 10 BRANCH 400 350 1 0.14 0.20


300 200
COLLAR 1200 150

44 VAV - 11 BRANCH 400 350 1 0.14 0.20


300 200
COLLAR 1200 150

44 VAV - 12 BRANCH 400 350 1 0.14 0.20


300 200
COLLAR 1200 150

44 VAV - 13 BRANCH 400 350 1 0.14 0.20


300 200
COLLAR 1200 150

44 VAV - 14 BRANCH 400 350 1 0.14 0.20


300 200
300 300
COLLAR 1200 150

44 VAV - 15 BRANCH 400 350 1 0.14 0.20


300 200
300 300
COLLAR 1200 150

47 MAIN 600 550 1 0.33 0.33


48 MAIN 600 550
49 MAIN 600 550
50 VAV - 38 BRANCH 300 350 1 0.11 0.20
51 BRANCH 600 550
52 SUB BRANCH 300 250
COLLAR 750 150
53 BRANCH 400 300
54 DIFFUSER 450 150
COLLAR 450 450
55 DIFFUSER 450 150

56 VAV - 39 BRANCH 350 550 1 0.19 0.20


57 SUB BRANCH 250 250
58 SUB BRANCH 200 200
59 DIFFUSER 450 150
60 DIFFUSER 450 150
COLLAR 450 450
61 SUB BRANCH 250 350 1 0.09 0.20
62 SUB BRANCH 200 200 0.00 0.00
COLLAR 1200 150
62 SUB BRANCH 200 200 1 0.04 0.20
63 DIFFUSER 450 150
COLLAR 450 450

LEFT WING MEETING RM


1 MAIN 600 400 1 0.24 0.24
1 MAIN 600 400
2 MAIN 350 400
3 VAV - 19 BRANCH 400 300 1 0.12 0.20
4 300 150

5 VAV - 17 BRANCH 400 350 1 0.14 0.20


6 300 150

7 VAV - 18 BRANCH 400 350 1 0.14 0.20


6 300 150

8 VAV - 16 BRANCH 400 350 1 0.14 0.20


6 300 250
6 300 150

RETURN AIR
RA Bell Mouth in OFC 1050 550
1200 550
600 450
400 250

RA Bell Mouth in Conf RMs hp11:


600 450
Tentative
400 consideration.
250
Sizes are same as
repective supply ducts
Cabin RA Duct 600 550 1 0.33 0.33
600 550
hp11:
600 550
2300
RA collars per
400cabin 1 0.12 0.20
Considered

COLLAR 600 150

TOILET
1 SUPPLY 400 350
2 SUPPLY 250 250 1 0.06 0.20
3 COLLAR 250 100

1 EXHAUST 400 350


2 EXHAUST 250 150 1 0.04 0.20
3 EXHAUST 250 150 1 0.04 0.20
4 EXHAUST 250 150 1 0.04 0.20
5 EXHAUST 250 150 1 0.04 0.20

TFAD
1 SUPPLY 500 350 1 0.18 0.20
2 SUPPLY 500 250 1 0.13 0.20
2 SUPPLY 300 150 1 0.05 0.20
3 SUPPLY 1000 500 0.00 0.00

LIFT LOBBY
1 SUPPLY 450 350 1 0.16 0.20
2 COLLAR 550 200
GRAND TOTAL FOR LEFT WING OFFICE

GRAND TOTAL FOR RIGHT WING OFFICE

ENERGY BUILDING 02 - KITCHEN (CHAPATHI MAKING)

Sl. Dimensions LENGTH


Description
No. A1 B1 VCD B2 Mts
mm. mm. mm. mm.
TERRACE - LEFT WING

1 1800 CFM 800 300 17.0


2 1500 CFM 800 300 17.0
Insulation
LENGTH QTY (Thermal/ MAX AREA AREA(Sq mts.)
Accoustic)

Mts Nos (mm) 24 G 22 G 20 G 18 G

5.0 1 1.0 600 11.5 0.0 0.0 0.0


5.0 1 2.0 600 11.5 11.5 0.0 0.0 0.0
30.0 1 2.0 600 69.0 69.0 0.0 0.0 0.0
6.5 1 2.0 400 9.1 9.1 0.0 0.0 0.0
5.0 1 2.0 400 7.0 7.0 0.0 0.0 0.0
1.0 1 2.0 300 0.9 0.9 0.0 0.0 0.0
0.6 2 2.0 600 1.8 1.8 0.0 0.0 0.0

1.5 1 2.0 300 1.7 1.7 0.0 0.0 0.0


1.0 1 2.0 400 1.3 1.3 0.0 0.0 0.0
0.8 1 2.0 600 1.2 1.2 0.0 0.0 0.0
3.0 1 2.0 300 2.7 2.7 0.0 0.0 0.0
0.6 1 2.0 600 0.9 0.9 0.0 0.0 0.0

3.0 1 2.0 400 3.9 3.9 0.0 0.0 0.0

1.7 1 2.0 300 1.7 1.7 0.0 0.0 0.0


4.0 1 2.0 300 4.4 4.4 0.0 0.0 0.0
3.0 1 2.0 300 3.0 3.0 0.0 0.0 0.0

2.0 1 2.0 300 2.4 0.0 0.0 0.0


2.4
1.0 1 2.0 400 1.4 0.0 0.0 0.0
1.4

1.5 1 2.0 300 1.8 1.8 0.0 0.0 0.0


1.5 1 2.0 400 2.1 2.1 0.0 0.0 0.0
3.0 1 2.0 300 3.0 3.0 0.0 0.0 0.0
0.6 1 2.0 600 0.9 0.9 0.0 0.0 0.0

3.2 1 2.0 300 3.8 3.8 0.0 0.0 0.0


1.2 1 2.0 400 1.7 1.7 0.0 0.0 0.0
3.0 1 2.0 300 3.0 3.0 0.0 0.0 0.0
0.6 1 2.0 600 0.9 0.9 0.0 0.0 0.0
2.5 1 2.0 300 3.0 3.0 0.0 0.0 0.0
4.5 1 2.0 400 5.9 5.9 0.0 0.0 0.0
1.0 1 2.0 300 1.0 1.0 0.0 0.0 0.0
0.6 2 2.0 600 1.8 1.8 0.0 0.0 0.0

4.5 1 2.0 600 6.8 6.8 0.0 0.0 0.0

5.0 1 1.0 1200 17.5 0.0 0.0 0.0


5.0 1 2.0 1200 17.5 0.0 17.5 0.0 0.0
16.0 1 2.0 1200 56.0 0.0 56.0 0.0 0.0
14.0 1 2.0 750 36.4 36.4 0.0 0.0 0.0
6.0 1 2.0 600 13.8 13.8 0.0 0.0 0.0
4.5 1 2.0 300 5.4 5.4 0.0 0.0 0.0

8.5 1 2.0 400 12.8 12.8 0.0 0.0 0.0


2.5 1 2.0 500 4.0 4.0 0.0 0.0 0.0
3.5 2 2.0 300 7.0 7.0 0.0 0.0 0.0
1.0 4 2.0 1200 10.8 0.0 10.8 0.0 0.0

1.5 1 2.0 400 2.3 2.3 0.0 0.0 0.0


11.0 1 2.0 400 16.5 16.5 0.0 0.0 0.0
10.0 1 2.0 300 10.0 10.0 0.0 0.0 0.0
1.0 5 2.0 1200 13.5 0.0 13.5 0.0 0.0

6.0 1 2.0 400 9.0 9.0 0.0 0.0 0.0


3.8 1 2.0 300 3.8 3.8 0.0 0.0 0.0
1.0 4 2.0 1200 10.8 0.0 10.8 0.0 0.0

11.0 1 2.0 400 16.5 16.5 0.0 0.0 0.0


3.0 2 2.0 300 6.0 6.0 0.0 0.0 0.0
1.0 5 2.0 1200 13.5 0.0 13.5 0.0 0.0

6.0 1 2.0 400 9.0 9.0 0.0 0.0 0.0


3.0 1 2.0 300 3.0 3.0 0.0 0.0 0.0
1.0 4 2.0 1200 10.8 0.0 10.8 0.0 0.0

6.0 1 2.0 400 9.0 9.0 0.0 0.0 0.0


3.0 1 2.0 300 3.0 3.0 0.0 0.0 0.0
1.0 4 2.0 1200 10.8 0.0 10.8 0.0 0.0

8.0 1 2.0 400 12.0 12.0 0.0 0.0 0.0


5.0 1 2.0 300 5.0 5.0 0.0 0.0 0.0
7.0 1 2.0 300 8.4 8.4 0.0 0.0 0.0
1.0 4 2.0 1200 10.8 0.0 10.8 0.0 0.0

13.0 1 2.0 400 19.5 19.5 0.0 0.0 0.0


5.0 1 2.0 300 5.0 5.0 0.0 0.0 0.0
7.0 1 2.0 300 8.4 8.4 0.0 0.0 0.0
1.0 3 2.0 1200 8.1 0.0 8.1 0.0 0.0

5.0 1 1.0 600 11.5 0.0 0.0 0.0


5.0 1 2.0 600 11.5 11.5 0.0 0.0 0.0
12.0 1 2.0 600 27.6 27.6 0.0 0.0 0.0
1.7 1 2.0 350 2.2 2.2 0.0 0.0 0.0
9.0 1 2.0 600 20.7 20.7 0.0 0.0 0.0
6.0 1 2.0 300 6.6 6.6 0.0 0.0 0.0
1.0 2 2.0 750 3.6 3.6 0.0 0.0 0.0
14.0 1 2.0 400 19.6 19.6 0.0 0.0 0.0
2.5 1 2.0 450 3.0 3.0 0.0 0.0 0.0
0.4 3 2.0 450 2.2 2.2 0.0 0.0 0.0
0.6 2 2.0 450 1.4 1.4 0.0 0.0 0.0

3.6 1 2.0 550 6.5 6.5 0.0 0.0 0.0


8.0 1 2.0 250 8.0 8.0 0.0 0.0 0.0
4.0 1 2.0 200 3.2 3.2 0.0 0.0 0.0
1.5 1 2.0 450 1.8 1.8 0.0 0.0 0.0
0.6 2 2.0 450 1.4 1.4 0.0 0.0 0.0
0.4 3 2.0 450 2.2 2.2 0.0 0.0 0.0
8.0 1 2.0 350 9.6 9.6 0.0 0.0 0.0
6.0 1 2.0 200 4.8 4.8 0.0 0.0 0.0
1.0 2 2.0 1200 5.4 0.0 5.4 0.0 0.0
3.0 1 2.0 200 2.4 2.4 0.0 0.0 0.0
1.5 3 2.0 450 5.4 5.4 0.0 0.0 0.0
1.0 2 2.0 450 3.6 3.6 0.0 0.0 0.0

6 1 1.0 600 11.0 0.0 0.0 0.0


6 1 2.0 600 11.0 11.0 0.0 0.0 0.0
15 1 2.0 400 22.5 22.5 0.0 0.0 0.0
3.8 1 2.0 400 5.3 5.3 0.0 0.0 0.0
1.0 2 2.0 300 1.8 1.8 0.0 0.0 0.0

16.0 1 2.0 400 24.0 24.0 0.0 0.0 0.0


1 4 2.0 300 4.7 4.7 0.0 0.0 0.0

10.0 1 2.0 400 15.0 15.0 0.0 0.0 0.0


1 4 2.0 300 3.6 3.6 0.0 0.0 0.0

9.0 1 2.0 400 13.5 13.5 0.0 0.0 0.0


5 2 2.0 300 10.1 10.1 0.0 0.0 0.0
0.5 6 2.0 300 2.7 2.7 0.0 0.0 0.0

1.0 2 2.0 1050 6.4 0.0 6.4 0.0 0.0


1 1 2.0 1200 3.5 0.0 3.5 0.0 0.0
5 1 2.0 600 10.5 10.5 0.0 0.0 0.0
1 6 2.0 400 7.8 7.8 0.0 0.0 0.0

5 1 2.0 600 10.5 10.5 0.0 0.0 0.0


1 3 2.0 400 3.9 3.9 0.0 0.0 0.0

5.0 1 1.0 600 11.5 0.0 0.0 0.0


5.0 1 2.0 600 11.5 11.5 0.0 0.0 0.0
30.0 1 2.0 600 69.0 69.0 0.0 0.0 0.0
6.5 1 2.0 400 9.1 9.1 0.0 0.0 0.0

1.0 14 2.0 600 21.0 21.0 0.0 0.0 0.0

10 1 2.0 400 15.0 15.0 0.0 0.0 0.0


8 1 2.0 250 8.0 8.0 0.0 0.0 0.0
1 6 2.0 250 3.4 3.4 0.0 0.0 0.0

14 1 2.0 400 21.0 21.0 0.0 0.0 0.0


2 1 2.0 250 1.6 1.6 0.0 0.0 0.0
4 1 2.0 250 3.2 3.2 0.0 0.0 0.0
4 1 2.0 250 3.2 3.2 0.0 0.0 0.0
4 1 2.0 250 3.2 3.2 0.0 0.0 0.0

3 1 2.0 500 5.1 5.1 0.0 0.0 0.0


10 1 2.0 500 15.0 15.0 0.0 0.0 0.0
8 1 2.0 300 7.2 7.2 0.0 0.0 0.0
1 1 2.0 1000 1.5 0.0 1.5 0.0 0.0

2 1 450 3.2 3.2 0.0 0.0 0.0


1 1 550 1.5 1.5 0.0 0.0 0.0
WING OFFICE 880.5 179.4 0.0 0.0

T WING OFFICE 880.5 179.4 0.0 0.0

Insulation Accoust
QTY (Thermal/ MAX AREA AREA(Sq mts.) ic
Accoustic)
Insulati
Nos (mm) SQ MT 24 G 22 G 20 G 18 G on
2 800 74.8 0.0 74.8 0.0 0.0 0.0
2 800 74.8 0.0 74.8 0.0 0.0 0.0
Accoustic Thermal Sl. Dimensions
Description

Insulation Insulation No. A1 B1


mm. mm.
LEFT WING - RISER
11.5 0.0 1 TFAD AHU RM - LEFT WING 1500 650
0.0 11.5 2 SED - LEFT WING 1350 650
0.0 69.0 3 TFAD CORRIDOR - LEFT WING 1050 400
0.0 9.1 4 MAKE UP AIR - LEFT WING 1350 650
0.0 7.0 5 TFAD CORRIDOR - LEFT WING 1200 600
0.0 0.9 6 TOILET EXHAUST 1200 600
0.0 1.8
RIGHT WING - RISER
0.0 1.7 1 TFAD AHU RM - RIGHT WING 1500 650
0.0 1.3 2 SED - RIGHT WING 1350 650
0.0 1.2 3 TFAD CORRIDOR - RIGHT WING 1050 400
0.0 2.7 4 MAKE UP AIR - RIGHT WING 1350 650
0.0 0.9 5 TFAD CORRIDOR - RIGHT WING 1200 600
6 TOILET EXHAUST 1200 600
0.0 3.9
GRAND TOTAL
0.0 1.7
0.0 4.4
0.0 3.0

TERRACE DUCTING WITH EXPOSED THERMAL INSULATION

0.0 2.4 Sl. Dimensions


Description
0.0 1.4 No. A1 B1
mm. mm.
0.0 1.8
0.0 2.1 TERRACE - LEFT WING
0.0 3.0
0.0 0.9 1 DOAS - LEFT WING 900 900
2 TFAD AHU RM - LEFT WING 1500 650
0.0 3.8 3 29400 CFM 1800 950
0.0 1.7 4 1050 400
0.0 3.0 5 1200 600
0.0 0.9 6 TOILET EXHAUST 1200 600
7 MAKE UP AIR - LEFT WING 1000 500
0.0 3.0
0.0 5.9 TERRACE - RIGHT WING
0.0 1.0
0.0 1.8 1 DOAS - LEFT WING 900 900
2 TFAD AHU RM - LEFT WING 1500 650
0.0 6.8 3 29400 CFM 1800 950
4 1050 400
17.5 0.0 5 1200 600
0.0 17.5 6 TOILET EXHAUST 1200 600
0.0 56.0 7 MAKE UP AIR - LEFT WING 1000 500
0.0 36.4
0.0 13.8 TERRACE - COMMON
0.0 5.4 1 PASSENGER 01 900 600
2 PASSENGER 02 900 600
0.0 12.8 3 PASSENGER 03 900 600
0.0 4.0 4 PASSENGER 04 900 600
0.0 7.0 5 PASSENGER 05 900 600
0.0 10.8 6 PASSENGER 06 900 600
7 PASSENGER 07 900 600
0.0 2.3 8 PASSENGER 08 900 600
0.0 16.5 9 PASSENGER 09 900 600
0.0 10.0 10 PASSENGER 10 900 600
0.0 13.5 11 PASSENGER 11 900 600
12 PASSENGER 12 900 600
0.0 9.0 13 PASSENGER LIFT LOBBY 01 900 600
0.0 3.8 14 LIFT LOBBY PRESS. 600 650
0.0 10.8 15 SERVICE LIFT WELL 01 900 600
16 SERVICE LIFT WELL 02 900 600
0.0 16.5 17 SERVICE LIFT WELL 03 900 600
0.0 6.0
0.0 13.5 2F TERRACE
1 STR 05 900 600
0.0 9.0 1 SERVICE LIFT WELL 04 900 600
0.0 3.0 1 SERVICE LIFT WELL 05 900 600
0.0 10.8
GRAND TOTAL
0.0 9.0
0.0 3.0
0.0 10.8

0.0 12.0
0.0 5.0
0.0 8.4
0.0 10.8

0.0 19.5
0.0 5.0
0.0 8.4
0.0 8.1

11.5 0.0
0.0 11.5
0.0 27.6
0.0 2.2
0.0 20.7
0.0 6.6
0.0 3.6
0.0 19.6
0.0 3.0
0.0 2.2
0.0 1.4

0.0 6.5
0.0 8.0
0.0 3.2
0.0 1.8
0.0 1.4
0.0 2.2
0.0 9.6
0.0 4.8
0.0 5.4
0.0 2.4
0.0 5.4
0.0 3.6

11.0 0.0
0.0 11.0
0.0 22.5
0.0 5.3
0.0 1.8

0.0 24.0
0.0 4.7

0.0 15.0
0.0 3.6

0.0 13.5
0.0 10.1
0.0 2.7

0.0 6.4
0.0 3.5
0.0 10.5
0.0 7.8

0.0 10.5
0.0 3.9

11.5 0.0
0.0 11.5
0.0 69.0
0.0 9.1

0.0 21.0

0.0 15.0
0.0 8.0
0.0 3.4

0.0 21.0
0.0 1.6
0.0 3.2
0.0 3.2
0.0 3.2

0.0 5.1
0.0 15.0
0.0 7.2
0.0 1.5

0.0 0.0
0.0 0.0
63.0 1055.2

63.0 1055.2

Thermal

Insulation
0.0
0.0
Insulation
Dimensions LENGTH QTY (Thermal/ MAX AREA AREA(Sq mts.)
Accoustic)

VCD B2 Mts Nos (mm) SQ MT 24 G 22 G


mm. mm.

75.0 1 2.0 1500 322.5 0.0 322.5


3.0 PDA:
1 Masonary Shaft 1350 12.0 0.0 12.0
Considered
75.0 1 2.0 1050 217.5 0.0 217.5
3.0 PDA:
1 Masonary Shaft 1350 12.0 0.0 12.0
Considered
75.0 1 2.0 1200 270.0 0.0 270.0
75.0 1 2.0 1200 270.0 0.0 270.0

75.0 1 2.0 1500 322.5 0.0 322.5


3.0 PDA:
1 Masonary Shaft 1350 12.0 0.0 12.0
Considered
75.0 1 2.0 1050 217.5 0.0 217.5
3.0 PDA:
1 Masonary Shaft 1350 12.0 0.0 12.0
Considered
75.0 1 2.0 1200 270.0 0.0 270.0
75.0 1 2.0 1200 270.0 0.0 270.0

GRAND TOTAL 0.0 2208.0

Insulation
Dimensions LENGTH QTY (Thermal/ MAX AREA AREA(Sq mts.)
Accoustic)

VCD B2 Mts Nos (mm) SQ MT 24 G 22 G


mm. mm.

2.0 1 2.0 900 7.2 0.0 7.2


Y 16.0 1 2.0 1500 68.8 0.0 68.8
3.0 1 2.0 1800 16.5 0.0 0.0
Y 8.0 1 2.0 1050 23.2 0.0 23.2
Y 23.0 1 2.0 1200 82.8 0.0 82.8
Y 23.0 1 2.0 1200 82.8 0.0 82.8
Y 5.0 1 1000 15.0 0.0 15.0
2.0 1 2.0 900 7.2 0.0 7.2
Y 16.0 1 2.0 1500 68.8 0.0 68.8
3.0 1 2.0 1800 16.5 0.0 0.0
Y 8.0 1 2.0 1050 23.2 0.0 23.2
Y 23.0 1 2.0 1200 82.8 0.0 82.8
Y 23.0 1 2.0 1200 82.8 0.0 82.8
Y 5.0 1 1000 15.0 0.0 15.0

Y 2.0 1 900 6.0 0.0 6.0


Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0
75.0 1 650 187.5 187.5 0.0
5.0 1 900 15.0 0.0 15.0
2.0 1 900 6.0 0.0 6.0
2.0 1 900 6.0 0.0 6.0

Y 2.0 1 900 6.0 0.0 6.0


Y 2.0 1 900 6.0 0.0 6.0
Y 2.0 1 900 6.0 0.0 6.0

GRAND TOTAL 187.5 682.6


EXPOSED THERMAL INSULATION

AREA(Sq mts.) Accoustic Thermal ROUND DUCT - B1

20 G 18 G Insulation Insulation
RETURN SL.NO Dia. in mm

GROUND FLOOR
0.0 0.0 0.0 322.5 1 450
0.0 0.0 0.0 0.0
0.0 0.0 0.0 217.5 TOTAL
0.0 0.0 0.0 0.0
0.0 0.0 0.0 270.0 ROUND DUCT - PODIUM
0.0 0.0 0.0 270
SL.NO Dia. in mm

GROUND FLOOR
0.0 0.0 0.0 322.5 1 1150
0.0 0.0 0.0 0.0
0.0 0.0 0.0 217.5 TOTAL
0.0 0.0 0.0 0.0
0.0 0.0 0.0 270.0 SINGLE SKIN ROUND DUCT - GUEST TO
0.0 0.0 0.0 270
SL.NO Dia. in mm

0.0 0.0 0.0 1620.0 540.0 GROUND FLOOR


1 150

TOTAL

AREA(Sq mts.) Accoustic Thermal

20 G 18 G Insulation Insulation

0.0 0.0 0.0 7.2


0.0 0.0 0.0 68.8
16.5 0.0 0.0 16.5
0.0 0.0 0.0 23.2
0.0 0.0 0.0 82.8
0.0 0.0 0.0 82.8 82.8
0.0 0.0 0.0 0.0
0.0 0.0 0.0 7.2
0.0 0.0 0.0 68.8
16.5 0.0 0.0 16.5
0.0 0.0 0.0 23.2
0.0 0.0 0.0 82.8 82.8
0.0 0.0 0.0 82.8
0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0


0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0

33.0 0.0 0.0 562.6


UND DUCT - B1 Sl. Dimensions
Description

No. A1 B1 VCD
Qty in No.s Rmt Sqmt
mm. mm. mm.
MS KITCHEN EXHAUST
2 18 51 1 Horizantal At floor 2235.2 1372
2 Vertical Riser 2235.2 1372
2 18 51 3 unit connection at terrace 2235.2 1372

D DUCT - PODIUM GRAND TOTAL


Qty in No.s Rmt Sqmt
ROUND FLOOR
1 180 650

1 180 650

OUND DUCT - GUEST TOILET

Qty in No.s Rmt Sqmt


ROUND FLOOR
1 30 14

1 30 14
Insulation
imensions LENGTH QTY (Thermal MAX AREA AREA(Sq mts.) Accoustic Thermal
/
Accoustic)

B2 Mts Nos (mm) SQ MT 24 G 22 G 20 G 18 G Insulation Insulation


mm.

150.0 1 2.0 2235.2 1082.0 0.0 0.0 0.0 1082.0 0.0 1082.0
75.0 1 2235.2 541.0 0.0 0.0 0.0 541.0 0.0 0.0
10.0 2 2235.2 144.3 0.0 0.0 0.0 144.3 0.0 0.0

RAND TOTAL 0.0 0.0 0.0 1767.3 0.0 1082.0


VOLUME CONTROL DAMPERS - TYP FLOOR
SIZE IN mm
SL.NO Location QTY AREA
W D Nos SQ.MT
LEFT WING AHU
1 MAIN 600 550 1 0.33
2 VAV 07 - BRANCH 300 400 1 0.12
3 VAV 01 - BRANCH 300 250 1 0.08
4 VAV - 02 BRANCH 400 250 1 0.10
5 VAV - 03 BRANCH 300 300 1 0.09
6 VAV - 04 BRANCH 300 300 1 0.09
7 VAV - 05 BRANCH 300 300 1 0.09
8 VAV - 06 BRANCH 300 300 1 0.09
hp11: VCD QTY
9 ELEC ROOM 600
removed 150 0.00
10 MAIN 1200 550 1 0.66
11 VAV - 08 BRANCH 300 300 1 0.09
12 VAV - 9 BRANCH 400 350 1 0.14
13 VAV - 10 BRANCH 400 350 1 0.14
14 VAV - 11 BRANCH 400 350 1 0.14
15 VAV - 12 BRANCH 400 350 1 0.14
16 VAV - 13 BRANCH 400 350 1 0.14
17 VAV - 14 BRANCH 400 350 1 0.14
18 VAV - 15 BRANCH 400 350 1 0.14
19 MAIN 600 550 1 0.33
20 VAV - AHU Corridor 400 300 1 0.12
21 VAV - 38 BRANCH 300 350 1 0.11
22 VAV - 39 BRANCH 350 550 1 0.19
23 SUB BRANCH 250 350 1 0.09
24 SUB BRANCH 200 200 1 0.04
25 Meeting RM 300 150 1 0.05

TFAD
1 SUPPLY 500 350 1 0.18
2 SUPPLY 500 250 1 0.13
3 SUPPLY 300 150 1 0.05

LIFT LOBBY
1 SUPPLY 450 350 1 0.16

LEFT WING MEETING RM


1 MAIN 600 400 1 0.24
2 VAV - 19 BRANCH 400 300 1 0.12
3 VAV - 17 BRANCH 400 350 1 0.14
4 VAV - 18 BRANCH 400 350 1 0.14
5 VAV - 16 BRANCH 400 350 1 0.14
6 SUB BRANCH 300 250 1 0.08

TOILET
1 SUPPLY 400 350 1 0.14
2 EXHAUST 250 150 4 0.15
LEFT WING GRAND TOTAL

RIGHT WING GRAND TOTAL


VOLUME CONTROL DAMPERS - TERRACE
Billing SIZE IN mm
Area SL.NO Location QTY AREA
SQ.MT W D Nos SQ.MT
TERRACE - LEFT WING
0.33
0.20 1 TFAD AHU RM - LEFT WING 1500 650 1 0.98
0.20 2 1050 400 1 0.42
0.20 3 1200 600 1 0.72
0.20 4 TOILET EXHAUST 1200 600 1 0.72
0.20
0.20 LEFT WING GRAND TOTAL
0.20 TERRACE - RIGHT WING
0.00
0.66 1 TFAD AHU RM - LEFT WING 1500 650 1 0.98
0.20 2 1050 400 1 0.42
0.20 3 1200 600 1 0.72
0.20 4 TOILET EXHAUST 1200 600 1 0.72
0.20
0.20 RIGHT WING GRAND TOTAL
0.20
0.20
0.20
0.33
0.20
0.20
0.20
0.20
0.20
0.20

0.20
0.20
0.20

0.20

0.24
0.20
0.20
0.20
0.20
0.20

0.20
0.80
9

9
MOTORISED FIRE DAMPERS - TYP FLOOR
Billing SIZE IN mm
Area SL.NO Location QTY
SQ.MT W D Nos
LEFT WING AHU
1 SED 1200 550 1
0.98 2 SMOKE MAKE UP 2000 600 1
hp11:
0.42 3 AHU 1000
Tentative 1000 1
0.72 4 TFAD 1000 500 1
0.72 5 TFAD 500 350 1
6 TFAD 500 250 1
3 7 RAD 1050 550 2
8 RAD 1200 550 1
9 TOI - supply 400 350 1
0.98
0.42 RIGHT WING AHU
0.72 1 SED 1200 550 1
0.72 2 SMOKE MAKE UP 2000 600 1
hp11:
3 AHU 1000
Tentative 1000 1
3 4 TFAD 1500 600 1
5 TFAD 500 350 1
6 TFAD 500 250 1
7 RAD 1800 550 2
8 RAD 1500 550 1
9 TOI - supply 400 350 1

LIFT LOBBY
1 PRESS. 450 350 1

GRAND TOTAL PER FLOOR

MOTORISED FIRE DAMPERS - TERRACE


SIZE IN mm QTY
SL.NO Location
W D Nos
TERRACE - LEFT WING
1 SED 1350 650 1
2 TFAD AHU RM - LEFT WING 1500 650 1
3 TFAD AHU RM - LEFT WING 1050 400 1
4 TFAD AHU RM - LEFT WING 1200 600 1
5 TOILET EXHAUST 1200 600 1

LEFT WING GRAND TOTAL

TERRACE - RIGHT WING


1 SED 1350 650 1
2 TFAD AHU RM - LEFT WING 1500 650 1
3 TFAD AHU RM - LEFT WING 1050 400 1
4 TFAD AHU RM - LEFT WING 1200 600 1
5 TOILET EXHAUST 1200 600 1

RIGHT WING GRAND TOTAL


TERRACE - COMMON
13 PASSENGER LIFT LOBBY 01 900 600 1

COMMON GRAND TOTAL


FLOOR NON RETURN DAMPERS
Billing SL.NO LOCATION TERMINAL
AREA Area
SQ.MT SQ.MT WIDTH HEIGHT
LEFT WING TOILET
0.66 0.66 27 EXHAUST 400 300
1.20 1.20
1.00 1.00 RIGHT WING TOILET
0.50 0.50 27 EXHAUST 400 300
0.18 0.20
0.13 0.20 GRAND TOTAL PER FLOOR
1.16 1.16
0.66 0.66
0.14 0.20

0.66 0.66
1.20 1.20
1.00 1.00
0.90 0.90
0.18 0.20
0.13 0.20
1.98 1.98
0.83 0.83
0.14 0.20

0.16 0.20

13.14

RRACE Billing
AREA Area
SQ.MT SQ.MT

0.88 0.88
0.98 0.98
0.42 0.42
0.72 0.72
0.72 0.72

3.7

0.88 0.9
0.98 1.0
0.42 0.4
0.72 0.7
0.72 0.7

3.7

0.54 0.5

0.5
DAMPERS PRESSURE RELIEF DAMPERS
Billing
QTY AREA SL.NO LOCATION TERMINAL
Area
Nos SQ.MT SQ.MT WIDTH
TERRACE
1 0.1 0.2 1 PASSENGER LIFT WELL 1000
2 SERVICE LIFT WELL 1000
3 STAIRCASE 5 700
1 0.1 0.2
TOTAL
LOOR 0.40
URE RELIEF DAMPERS SOUN
Billing
TERMINAL QTY AREA
Area SL.NO
HEIGHT Nos SQ.MT SQ.MT

1000 12 1.0 12.0 1


1000 5 1.0 5.0 2
700 1 0.5 0.5 3
4
17.49

1
2
3
4
SOUND ALT - TYP FLOOR
SIZE IN mm Billing
Location QTY AREA Area
W D Nos SQ.MT SQ.MT
LEFT WING AHU
AHU 600 550 1 0.33 0.33
AHU 1200 550 1 0.66 0.66
AHU 600 550 1 0.33 0.33
CS - AHU 600 550 1 0.33 0.33
1.65
RIGHT WING AHU
AHU 600 550 1 0.33 0.33
AHU 1200 550 1 0.66 0.66
AHU 600 550 1 0.33 0.33
CS - AHU 600 550 1 0.33 0.33
1.65

TOTAL PER FLOOR 3.63


2 way SUPPLY / RETURN GRILLES - OFFICE - 1
SL.NO LOCATION SUPPLY QTY AREA
WIDTH HEIGHT Nos SQ.MT
OFFICE
1 GF 1200 150 116 0.180
1 1F 1200 150 122 0.180
1 2F 1200 150 116 0.180
1 3F - 15F 1200 150 1157 0.180

GRAND TOTAL / FLOOR

2 way - SUPPLY / RETURN GRILLES - MEETING RM


SL.NO LOCATION SUPPLY QTY AREA
WIDTH HEIGHT Nos SQ.MT
LEFT WING
1 SUPPLY 600 150 6 0.09
2 SUPPLY 300 150 2 0.05
3 SUPPLY 300 150 8 0.05

RIGHT WING
1 SUPPLY 600 150 6 0.09
2 SUPPLY 300 150 2 0.05
3 SUPPLY 300 150 8 0.05

GRAND TOTAL / FLOOR

1 way - SUPPLY GRILLES -TREATED FRESH AIR -


SL.NO LOCATION SUPPLY QTY AREA
WIDTH HEIGHT Nos SQ.MT
LEFT WING
MAKE UP AIR DUCT 2000 600 1 1.2
ELEC RM 600 150 1 0.1
TFA 1000 1000 1 1.0

LEFT WING
MAKE UP AIR DUCT 2000 600 1 1.2
ELEC RM 600 150 1 0.1
TFA 1000 1000 1 1.0
GRAND TOTAL / FLOOR

1 way - FRESH AIR - PRESS. GRILLES - 15 D


SL.NO LOCATION SUPPLY QTY AREA
WIDTH HEIGHT Nos SQ.MT
STR 05 - PRESS
1 SUPPLY 1000 500 3 0.500
GRAND TOTAL / FLOOR

1 way - CURVED. GRILLES - 15 DEG D


SL.NO LOCATION SUPPLY QTY AREA
WIDTH HEIGHT Nos SQ.MT
RECEPTION
1 CURVED GRILLES 7000 150 1 1.1
GRAND TOTAL / FLOOR
RN GRILLES - OFFICE - 15 DEG DEF
Billing Billing
RETURN QTY AREA SL.NO
Area Area
SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

23.2 1200 150 165 0.180 33.0 1


24.4 1200 150 183 0.180 36.6 2
23.2 1200 150 175 0.180 35.0 3
231.4 1200 150 2220 0.180 444.0 4

0 0 1
2
3
GRILLES - MEETING RMs - 15 DEG DEF 4
Billing RETURN QTY AREA Billing
Area Area
SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT
GRA
1.2 19600 150 1 2.9 2.9
0.4 2000 150 2 0.3 0.6
1.6 3000 150 4 0.5 1.8

3 5

1.2 19600 150 1 2.9 2.9


0.4 2000 150 2 0.3 0.6
1.6 3000 150 4 0.5 1.8

3 5
6 11

-TREATED FRESH AIR - 15 DEG DEF


Billing Billing
RETURN QTY AREA
Area Area
SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

1.2
0.2
1.0
2 0

1.2
0.2
1.0
2 0
4.8 #REF!

PRESS. GRILLES - 15 DEG DEF


Billing Billing
RETURN QTY AREA
Area Area
SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

1.5 0.000 0.0


1.5 0.0

D. GRILLES - 15 DEG DEF


Billing Billing
RETURN QTY AREA
Area Area
SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

1.1 0.000 0.0


1.1 0.0
4 WAY - DIFFUSERS
LOCATION SUPPLY QTY AREA RETURN QTY
WIDTH HEIGHT Nos SQ.MT WIDTH HEIGHT Nos
LEFT WING
AHU CORRIDOR 300 300 2
BREAK OUT 300 300 6 0.5 300 300 6
RECEPTION 300 300 3 0.3 300 300 3
LIFT LOBBY 450 450 2 0.2
1.0
RIGHT WING
AHU CORRIDOR 300 300 2
BREAK OUT 300 300 6 0.5 300 300 6
RECEPTION 300 300 3 0.3 300 300 3
LIFT LOBBY 450 450 2 0.2
1.0

GRAND TOTAL / FLOOR 2.0


TOILET GRILLES
AREA SL.NO LOCATION SUPPLY QTY AREA
SQ.MT WIDTH HEIGHT Nos SQ.MT
TOILET - LEFT WING
0.2 1 SUPPLY 100 100 7 0.010
0.5 2 EXHAUST 100 100 9 0.0
0.3
TOILET - RIGHT WING
1.0 1 SUPPLY 100 100 7 0.010
2 EXHAUST 100 100 9 0.0
0.2
0.5 GRAND TOTAL / FLOOR
0.3

1.0

2.0
OILET GRILLES
Billing Billing
RETURN QTY AREA SL.NO
Area Area
SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

1.4 100 100 7 0.010 1.4


1.8 100 100 9 0.0 1.8
3 3

1.4 100 100 7 0.010 1.4


1.8 100 100 9 0.0 1.8
3 3
6 6
ACOUSTIC INSULATION
LOCATION SUPPLY QTY AREA RETURN
WIDTH HEIGHT Nos SQ.MT WIDTH
LEFT WING
False ceiling Acoustic Insulation 4 2 1 8.0
Wall Acoustic Insulation (Above False Ceiling) 11.5 0.6 1 6.9
Billing
RETURN QTY AREA
Area
HEIGHT Nos SQ.MT SQ.MT
Sl. Dimensions LENGTH
Description
No. A1 B1 VCD B2 Mts
mm. mm. mm. mm.
AHU 01
1 SUPPLY 1400 750 Y 7.0
2 SUPPLY 1400 750 7.0
3 RETURN 1500 750 Y 15.0
AHU 02
1 SUPPLY 1400 750 Y 5.5
2 SUPPLY 1400 750 5.5
3 RETURN 1500 750 Y 22.0
AHU 03
1 SUPPLY 1400 750 Y 7.0
2 SUPPLY 1400 750 20.0
3 RETURN 1500 750 Y 12.0
AHU 04
1 SUPPLY 1400 750 Y 7.0
2 SUPPLY 1400 750 15.0
3 RETURN 1500 750 Y 15.0
AHU 05
1 SUPPLY 1400 750 Y 5.0
2 SUPPLY 1400 750 5.0
3 RETURN 1500 750 Y 26.0
AHU 06
1 SUPPLY 1400 750 Y 7.0
2 SUPPLY 1400 750 9.0
3 RETURN 1500 750 Y 9.0
AHU 07
1 SUPPLY 1400 750 Y 7.0
2 SUPPLY 1400 750 9.0
3 RETURN 1500 750 Y 9.0
AHU 08
1 SUPPLY 1400 750 Y 7.0
2 SUPPLY 1400 750 15.0
3 RETURN 1500 750 Y 15.0
GRAND TOTAL FOR LEFT WING OFFICE
Insulation
QTY (Thermal/ MAX AREA AREA(Sq mts.) Accoustic
Accoustic)

Nos (mm) SQ MT 24 G 22 G 20 G 18 G Insulation

1 1.0 1400 30.1 0.0 0.0 0.0 30.1


1 2.0 1400 30.1 0.0 30.1 0.0 0.0 0.0
1 2.0 1500 67.5 0.0 67.5 0.0 0.0 0.0

1 1.0 1400 23.7 0.0 0.0 0.0 23.7


1 2.0 1400 23.7 0.0 23.7 0.0 0.0 0.0
1 2.0 1500 99.0 0.0 99.0 0.0 0.0 0.0

1 1.0 1400 30.1 0.0 0.0 0.0 30.1


1 2.0 1400 86.0 0.0 86.0 0.0 0.0 0.0
1 2.0 1500 54.0 0.0 54.0 0.0 0.0 0.0

1 1.0 1400 30.1 0.0 0.0 0.0 30.1


1 2.0 1400 64.5 0.0 64.5 0.0 0.0 0.0
1 2.0 1500 67.5 0.0 67.5 0.0 0.0 0.0

1 1.0 1400 21.5 0.0 0.0 0.0 21.5


1 2.0 1400 21.5 0.0 21.5 0.0 0.0 0.0
1 2.0 1500 117.0 0.0 117.0 0.0 0.0 0.0

1 1.0 1400 30.1 0.0 0.0 0.0 30.1


1 2.0 1400 38.7 0.0 38.7 0.0 0.0 0.0
1 2.0 1500 40.5 0.0 40.5 0.0 0.0 0.0

1 1.0 1400 30.1 0.0 0.0 0.0 30.1


1 2.0 1400 38.7 0.0 38.7 0.0 0.0 0.0
1 2.0 1500 40.5 0.0 40.5 0.0 0.0 0.0

1 1.0 1400 30.1 0.0 0.0 0.0 30.1


1 2.0 1400 64.5 0.0 64.5 0.0 0.0 0.0
1 2.0 1500 67.5 0.0 67.5 0.0 0.0 0.0
FFICE 0.0 921.2 0.0 0.0 225.7
Thermal Thermal ROUND DUCT

Insulation ra Insulation
SL.NO Dia. in mm Qty in No.s Rmt Sqmt

GROUND FLOOR
0.0 1 1150 1 180 650
30.1 TOTAL 1 180 650
67.5 67.5

0.0
23.7
99.0 99.0

0.0
86.0
54.0 54.0

0.0
64.5
67.5 67.5

0.0
21.5
117.0

0.0
38.7
40.5 40.5

0.0
38.7
40.5 40.5

0.0
64.5
67.5 67.5
921.2 436.5 484.7
VOLUME CONTROL DAMPERS
SIZE IN mm
SL.NO Location QTY AREA
W D Nos SQ.MT
AHU 01
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1 1.13


AHU 02 0.00
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1 1.13


AHU 03 0.00
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1 1.13


AHU 04 0.00
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1


1.13
AHU 05 0.00
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1 0.00


AHU 06 0.00
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1 1.13


AHU 07 0.00
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1 1.13


AHU 08
1 SUPPLY 1400 750 1 1.05

3 RETURN 1500 750 1 1.13


GRAND TOTAL
LOUVERS
Billing SL.NO LOCATION SUPPLY QTY
Area
SQ.MT WIDTH HEIGHT Nos

1.05 AHU 01 1000 300 4


AHU 02 1000 300 6
1.13 AHU 03 1000 300 4
0.00 AHU 04 1000 300 6
1.05 AHU 05 1000 300 4
AHU 06 1000 300 5
1.13 AHU 07 1000 300 4
0.00 AHU 08 1000 300 6
1.05

1.13
0.00
1.05
SUPPLY GRILLES - BOTTOM GR
SL.NO LOCATION SUPPLY QTY
1.13
0.00 WIDTH HEIGHT Nos
1.05 OFFICE
1 SUPPLY 100 300 36
1.13 GRAND TOTAL / FLOOR
0.00
1.05

1.13
0.00
1.05

1.13

1.05

1.13
17
LOUVERS
Billing Billing
AREA RETURN QTY AREA
Area Area
SQ.MT SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

0.3 1.2 ARCHITECTURE


0.3 1.8
0.3 1.2
0.3 1.8
0.3 1.2
0.3 1.5
0.3 1.2
0.3 1.8

13 0

UPPLY GRILLES - BOTTOM GRILLE - 15 DEG DEF


Billing Billing
AREA Area RETURN QTY AREA Area
SQ.MT SQ.MT WIDTH HEIGHT Nos SQ.MT SQ.MT

0.030 7.2
7 0
MOTORIZED FIRE DAMPERS
SIZE IN mm Billing
SL.NO Location QTY AREA Area
W D Nos SQ.MT SQ.MT
AHU 01
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1 1.13 1.13


AHU 02 0.00 0.00
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1 1.13 1.13


AHU 03 0.00 0.00
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1 1.13 1.13


AHU 04 0.00 0.00
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1


1.13 1.13
AHU 05 0.00 0.00
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1 1.13 1.13


AHU 06 0.00 0.00
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1 1.13 1.13


AHU 07 0.00 0.00
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1 1.13 1.13


AHU 08
1 SUPPLY 1400 750 1 1.05 1.05

3 RETURN 1500 750 1 1.13 1.13


GRAND TOTAL 17
Sl. Dimensions
Description
No. A1 B1 VCD B2

mm. mm. mm. mm.


ELE YARD
1 PANEL ROOM 1300 500 0.00
2 PANEL ROOM 1300 500 0.00
3 WORKSHOP 800 400 0.00
4 HT PANEL ROOM 800 400 0.00

HVAC PLANT RM
1 25500 CFM 1500 1100 0.00
2 1200 1100 0.00
3 1200 800 0.00
4 800 800 0.00

8500 CFM 1000 500

1000 500

10000 CFM (cowl) 1000 800

GRAND TOTAL FOR LEFT WING OFFICE

GRILLES - 0 DEG 1 w DEF


Billing
SL.NO LOCATION SUPPLY QTY AREA
Area
WIDTH HEIGHT Nos SQ.MT SQ.MT
ELE YARD
PANEL ROOM
PANEL ROOM
WORKSHOP
HT PANEL ROOM

1 25500 CFM 600 350 8 0.210 1.7

8500 CFM 1000 500 1 0.500 0.5

10000 CFM

GRAND TOTAL / FLOOR 2.2


GRILLES - 15 deg Single way DEF
1 25500 CFM 600 350 16 0.210 3.4

GRAND TOTAL / FLOOR 3.36


Insulation
LENGTH QTY (Thermal/ MAX AREA AREA(Sq mts.)
Accoustic)

Mts Nos (mm) 24 G 22 G 20 G 18 G

19.0 1 1300 68.4 68.4 0.0 0.0


19.0 1 0.0 1300 68.4 0.0 68.4 0.0 0.0
12.0 1 0.0 800 28.8 0.0 28.8 0.0 0.0
12.0 1 0.0 800 28.8 0.0 28.8 0.0 0.0

13.0 1 1500 67.6 67.6 0.0 0.0


10.0 1 1200 46.0 46.0 0.0 0.0
10.0 1 1200 40.0 40.0 0.0 0.0
8.0 1 800 25.6 25.6 0.0 0.0

8.0 1 1000 24.0 0.0 0.0


24.0
2.0 1 1000 6.0 6.0 0.0 0.0

5.0 3 1000 54.0 54.0 0.0 0.0

WING OFFICE 0.0 457.6 0.0 0.0

DEG 1 w DEF
Billing
RETURN QTY AREA
Area
WIDTH HEIGHT Nos SQ.MT SQ.MT

2.2537175
2.2537175
0.6273234
0.5

1000 500 1 0.500 0.5

6.1
g Single way DEF
0
Accoustic Thermal VOLUME CONTROL DAMPERS

Insulation Insulation SIZE IN mm


SL.NO Location QTY
W D Nos

0.0 0.0 1 PANEL ROOM 1300 500 1


0.0 0.0 PANEL ROOM 1300 500 1
0.0 0.0 WORKSHOP 800 400 1
0.0 0.0 HT PANEL ROOM 800 400 1

25500 CFM 1500 1100 1


0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
LOUVERS
0.0 0.0 SIZE IN mm
SL.NO Location QTY
0.0 0.0 W D Nos

0.0 0.0 1 8500 CFM 1000 500 1


10000 CFM 1200 800 1
0.0 0.0 6000 CFM 800 800 1

PHE PUMP RM FA 800 800 2


PHE PUMP RM EA 800 800 2
hp11:
PHE PUMP RM EA 600 600 1
5100 CFM

9700 CFM 1200 800 2


MPERS

Billing
AREA Area
SQ.MT SQ.MT

0.65 0.65
0.65 0.65
0.32 0.32
0.32 0.32

1.65 1.65
3.6

Billing
AREA Area
SQ.MT SQ.MT

0.50 0.50
0.96 0.96
0.64 0.64

1.28 1.28
1.28 1.28
0.36 0.36

1.92 1.92

6.9