0% found this document useful (0 votes)
88 views8 pages

3rp25051aw30 Temporizador Siemens Especificaciones

This document provides specifications for the SIRIUS 3RP2505-1AW30 timing relay. The timing relay has 1 change-over contact, 13 functions across 7 time ranges from 0.05 seconds to 100 hours. It operates on 12-240V AC/DC power with LED indication. Key specifications include 13 timing functions, 5A thermal current, IP20 degree of protection, and operating temperature range.

Uploaded by

Jonathan Cerrano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views8 pages

3rp25051aw30 Temporizador Siemens Especificaciones

This document provides specifications for the SIRIUS 3RP2505-1AW30 timing relay. The timing relay has 1 change-over contact, 13 functions across 7 time ranges from 0.05 seconds to 100 hours. It operates on 12-240V AC/DC power with LED indication. Key specifications include 13 timing functions, 5A thermal current, IP20 degree of protection, and operating temperature range.

Uploaded by

Jonathan Cerrano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Data sheet 3RP2505-1AW30

Timing relay, Multifunction 1 change-over contact, 13 functions 7


time ranges (0.05 s...100 h) 12...240 V AC/DC at 50/60 Hz AC with
LED, Screw terminal

Product brand name SIRIUS


Product designation timing relay
Design of the product 13 functions
Product type designation 3RP25

General technical data


Product component
● Relay output Yes
● semi-conductor output No
Product extension required remote control No
Product extension optional remote control No
Insulation voltage
● for overvoltage category III according to IEC
60664
— with degree of pollution 3 rated value 300 V
Test voltage for isolation test 2.5 kV
Degree of pollution 3
Surge voltage resistance rated value 4 000 V
Protection class IP IP20
Shock resistance

3RP2505-1AW30 Subject to change without notice


Page 1/8 11/27/2019 © Copyright Siemens
● acc. to IEC 60068-2-27 11g / 15 ms
Vibration resistance
● acc. to IEC 60068-2-6 10 ... 55 Hz / 0.35 mm
Mechanical service life (switching cycles)
● typical 10 000 000
Electrical endurance (switching cycles)
● at AC-15 at 230 V typical 100 000
Adjustable time 0.05 s ... 100 h
Relative setting accuracy relating to full-scale value 5%
Thermal current 5A
Minimum ON period 35 ms
Recovery time 250 ms
Reference code acc. to DIN 40719 extended K
according to IEC 204-2 acc. to IEC 750
Reference code acc. to DIN EN 81346-2 K
Reference code acc. to DIN EN 61346-2 K
Relative repeat accuracy 1%

Control circuit/ Control


Type of voltage of the control supply voltage AC/DC
Control supply voltage 1 at AC
● at 50 Hz 12 ... 240 V
● at 60 Hz 12 ... 240 V
Control supply voltage frequency 1 50 ... 60 Hz
Control supply voltage 1
● at DC 12 ... 240 V
Operating range factor control supply voltage rated
value at DC
● initial value 0.8
● Full-scale value 1.1
Operating range factor control supply voltage rated
value at AC at 50 Hz
● initial value 0.85
● Full-scale value 1.1
Operating range factor control supply voltage rated
value at AC at 60 Hz
● initial value 0.85
● Full-scale value 1.1
Inrush current peak
● at 24 V 0.4 A
● at 240 V 5A
Duration of inrush current peak
● at 24 V 0.3 ms
● at 240 V 0.5 ms

3RP2505-1AW30 Subject to change without notice


Page 2/8 11/27/2019 © Copyright Siemens
Switching Function
Switching function
● ON-delay Yes
● ON-delay/instantaneous contact No
● passing make contact Yes
● passing make contact/instantaneous contact No
● OFF delay No
Switching function
● flashing symmetrically starting with No
interval/instantaneous
● flashing symmetrically starting with interval Yes
● flashing symmetrically starting with No
pulse/instantaneous
● flashing symmetrically starting with pulse Yes
● flashing asymmetrically starting with interval No
● flashing asymmetrically starting with pulse No
Switching function
● star-delta circuit with delay time No
● star-delta circuit No
Switching function with control signal
● additive ON delay Yes
● passing break contact Yes
● passing break contact/instantaneous No
● OFF delay Yes
● OFF delay/instantaneous No
● pulse delayed Yes
● pulse delayed/instantaneous No
● pulse-shaping Yes
● pulse-shaping/instantaneous No
● additive ON delay/instantaneous No
● ON-delay/OFF-delay/instantaneous No
● passing make contact Yes
● passing make contact/instantaneous contact No
Switching function of interval relay with control signal
● retrotriggerable with deactivated control No
signal/instantaneous contact
● retrotriggerable with activated control signal Yes
● retrotriggerable with activated control No
signal/instantaneous contact
● retriggerable with deactivated control signal Yes
Design of the control terminal non-floating Yes

3RP2505-1AW30 Subject to change without notice


Page 3/8 11/27/2019 © Copyright Siemens
Short-circuit protection
Design of the fuse link
● for short-circuit protection of the auxiliary switch fuse gL/gG: 4 A
required

Auxiliary circuit
Material of switching contacts AgSnO2
Number of NC contacts
● delayed switching 0
Number of NO contacts
● delayed switching 0
Number of CO contacts
● delayed switching 1
Operating current of auxiliary contacts at AC-15
● at 24 V 3A
● at 250 V 3A
Operating current of auxiliary contacts at DC-13
● at 24 V 1A
● at 125 V 0.2 A
● at 250 V 0.1 A
Operating frequency with 3RT2 contactor maximum 5 000 1/h
Contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching
operations (17 V, 5 mA)
Contact rating of auxiliary contacts according to UL R300 / B300
Influence of the surrounding temperature 1% in the whole temperature range to the set runtime
Power supply influence 1% in the whole voltage range to the set runtime
Switching capacity current with inductive load 0.01 ... 3 A

Inputs/ Outputs
Product function
● at the relay outputs Switchover delayed/without No
delay
● non-volatile No

Electromagnetic compatibility
EMI immunity
● acc. to IEC 61812-1 EN 61000-6-2
Conducted interference
● due to burst acc. to IEC 61000-4-4 2 kV network connection / 1 kV control connection
● due to conductor-earth surge acc. to IEC 2 kV
61000-4-5
● due to conductor-conductor surge acc. to IEC 1 kV
61000-4-5
Field-bound parasitic coupling acc. to IEC 61000-4-3 10 V/m
Electrostatic discharge acc. to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge

3RP2505-1AW30 Subject to change without notice


Page 4/8 11/27/2019 © Copyright Siemens
Safety related data
Protection against electrical shock finger-safe
Type of insulation Basic insulation
Category acc. to EN 954-1 none

Connections/ Terminals
Product function
● removable terminal for auxiliary and control Yes
circuit
Type of electrical connection
● for auxiliary and control current circuit screw-type terminals
Type of connectable conductor cross-sections
● solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
● finely stranded with core end processing 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²)
● at AWG conductors solid 1x (20 ... 12), 2x (20 ... 14)
● at AWG conductors stranded 1x (20 ... 12), 2x (20 ... 14)
Connectable conductor cross-section
● solid 0.5 ... 4 mm²
● finely stranded with core end processing 0.5 ... 4 mm²
AWG number as coded connectable conductor cross
section
● solid 20 ... 12
● stranded 20 ... 14
Tightening torque 0.6 ... 0.8 N·m
Design of the thread of the connection screw M3

Installation/ mounting/ dimensions


Mounting position any
Mounting type screw and snap-on mounting onto 35 mm standard mounting rail
Height 100 mm
Width 17.5 mm
Depth 90 mm
Required spacing
● with side-by-side mounting
— forwards 0 mm
— Backwards 0 mm
— upwards 0 mm
— downwards 0 mm
— at the side 0 mm
● for grounded parts
— forwards 0 mm
— Backwards 0 mm
— upwards 0 mm
— at the side 0 mm

3RP2505-1AW30 Subject to change without notice


Page 5/8 11/27/2019 © Copyright Siemens
— downwards 0 mm
● for live parts
— forwards 0 mm
— Backwards 0 mm
— upwards 0 mm
— downwards 0 mm
— at the side 0 mm

Ambient conditions
Installation altitude at height above sea level
● maximum 2 000 m
Relative humidity
● during operation 10 ... 95 %

Certificates/ approvals
General Product Approval EMC Declaration of
Conformity

Declaration of Test Certific- Marine / Shipping


Conformity ates
Miscellaneous Type Test Certific-
ates/Test Report

Marine / Ship- other


ping
Confirmation

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
www.siemens.com/sirius/catalogs
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RP2505-1AW30
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP2505-1AW30
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RP2505-1AW30

3RP2505-1AW30 Subject to change without notice


Page 6/8 11/27/2019 © Copyright Siemens
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP2505-1AW30&lang=en

91.6

17.5 86.5

S IRIU S
3 RP2 5 0 5 - 1 AW3 0

A2 ( - ) A2 ( - )
1 2 ...2 4 0 V
AC/ DC

A1 ( + ) B1 ( + )
3 RP2 5 0 5 - 1 AW3 0 50
100

1 6 NC 1 8 NO
15C

3 RP2 5 0 5 - 1 AW3 0

3RP2505-1AW30 Subject to change without notice


Page 7/8 11/27/2019 © Copyright Siemens
15 C
A1

B1
3 4 7

-K

1 2 5 6

18 NO
16 NC
A2

A2

last modified: 11/27/2019

3RP2505-1AW30 Subject to change without notice


Page 8/8 11/27/2019 © Copyright Siemens