Application
Prothermo NMT532 consists of an intelligent local HART signal converter and average
temperature sensor.
For average temperature measurement, it consists of
precision multi-spot Pt100 (Max.6) elements which have fixed interval (2m or 3m).
NMT532 is a highly capable solution for a variety of tank gauging applications and pro-
vides constant average temperature data via local HART communication.
For accurate inventory measurement, it is best suited
connected to Tank Side Monitor NRF590 with Micropilot radar tank gauge or Proservo
NMS5.
• High Accuracy
• Maintenance Free
Prothermo NMT532
Table of Contents
2 Endress+Hauser
Prothermo NMT532
DANGER DANGER!
This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in
A0011189-EN
serious or fatal injury.
WARNING WARNING!
This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in
A0011190-EN
serious or fatal injury.
CAUTION CAUTION!
This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in
A0011191-EN
minor or medium injury.
NOTICE!
NOTICE
This symbol contains information on procedures and other facts which do not result in
A0011192-EN
personal injury.
Recommendation
Indicates procedures, processes or actions that are recommended.
A0011183
Forbidden
Indicates procedures, processes or actions that are forbidden.
A0011184
Tip
Indicates additional information.
A0011193
Endress+Hauser 3
Prothermo NMT532
Operation Principle
Converter Housing
CPU Module
Flange
Gas Phase
Liquid Phase
System Design
Data Management Field Process
Temperature
Level Gauge
System
Host Application
Field Interface
NXA820
Tankvision NXA83
DCS Liquid /Gas Temperature
PLC Level
Others
Pressure Gauge
Endress+Hauser offers a wide range of solutions to integrate field data into your process management
requirement.
The following diagrams describe some individual solutions according to various Ex concepts. For addi-
tional application requirements, contact local Endress+Hauser representatives.
4 Endress+Hauser
Prothermo NMT532
Ex i HART Loop
(Data Transmission)
FMR Power
(DC, Ex i)
NMT532
Tankvision
sion
FMR 540
Liquid Level
Water Interface
(WB)
NRF590
NMT532 + FMR53x + Temperature and level measurement with data collection and calculations via NRF590 allows for opti-
NRF590 mal inventory control. Basic functionality of NMT532 is displayed and configured on NRF590. Detailed
NMT532 functionality and data access can be performed by FieldCare.
NMT532 receives radar level data from NRF590 and then calculates liquid and gas phase average tem-
perature. Calculated and standard data including temperature element raw data and device status are
transmitted to NRF590.
All gathered data in the interface unit is sent to inventory management software, such as
Endress+Hauser tank vision, Tank computer or directly sent to the customer's specific DCS or PLC.
Endress+Hauser 5
Prothermo NMT532
Ex i HART Loop
(Data Transmission)
NMT532
Power (AC/DC)
Ex d HART Loop
(Data Transmission
& Remote Control)
NMS5
Power (AC/DC)
Liquid Level
NRF560
NMT532 + NMS5+ NRF560 NMT532 is used most effectively with NMS5 to provide average temperature, level, water
interface, and density measurement.
All the necessary configuration and parameter settings for NMT532 are performed via either NMS5 or
FieldCare.
NMT532 receives liquid level data from NMS5, then calculates liquid and gas phase average
temperature. Calculated data and basic information including raw data for each temperature element
and device status are transmitted to NMS5.
Since NMS5 is a multi-functional device (measurement and data transmission), a Promonitor NRF560
can act as a tank side remote data indicator and controller for NMS5.
All gathered data in the interface unit is sent to inventory management software, such as
Endress+Hauser’s Tankvision, Fuelsmanager, Tank computer or directly sent to the customer's specific
DCS or PLC.
6 Endress+Hauser
Prothermo NMT532
Alarm Signal Error information via the following interface and transmission digital protocol. Refer to Operating
Instructions of each device.
• NMS5: BA00401G
• NRF590: BA00256F, BA00257F
Output Signal Temperature data via 2 wire intrinsically safe local HART protocol.
Connection • NMS5
• NRF590
Endress+Hauser 7
Prothermo NMT532
Auxiliary Energy
Load HART Minimum loading for local HART circuit: 250Ω
Overvoltage Protection NMT532 has internal surge arrester which complies with EN/IEC 61000-4-5 (Line to Line 1.0kV).
Connect the metallic housing of the NMT532 to the tank wall or screen directly with an electrically
conductive lead to ensure reliable potential matching.
Cable Entry Wiring of NMT 532 must meet intrinsically safe requirements.
The following cable entries are available:
• Thread NPT 1/2
• Thread M 20
Ui = 30 V
Ii = 120mA Internal capacitance Ci = 7.9 nF
Pi = 1 W Internal inductance Li = 48 H
Grounding NMT532 must be grounded to the tank potential before connection to host gauge. All ground connec-
tions must be compliant with local and company regulations, and checked before the equipment is
commissioned.
8 Endress+Hauser
Prothermo NMT532
Performance Characteristics
Temperature Accuracy ± 0.1°C or better (at reference condition)
*Reference
Accuracy of RTD - Temperature Conversion
Maximum Measured Error Typical statements for reference conditions, include linearity, repeatability, and hysteresis:
• Linearity:
– Temperature: ±0.15°C (0.27°F) + element deviation (based on IEC 60751/DIN EN 60751class A
standard)
New Module NMT 532 employs a completely new electronic module compared to the previous NMT 535.
Endress+Hauser 9
Prothermo NMT532
Degree of Protection • Housing: IP65, NEMA 4X (Converter only, open housing: IP20)
• Probe: IP68
Interference Emission and immunity apply to each standard shown above when installing probes in
metal and concrete tanks and when using coax probes.
WARNING
When the pressure inside the tank exceeds 1 bar (100KPa, 14.5psi), stilling well which does not have
any holes or slits must be installed.
10 Endress+Hauser
Prothermo NMT532
Recommended Installation
Height
NMT532
NOTICE
The required bottom clearance of both the temperature probe and WB sensor varies depending on the
anchoring method. Consider the required bottom clearance when ordering NMT 532. See the recom-
mended bottom clearance in the above illustration and/or consult Endress+Hauser representatives for
further information.
The standard location of the lowest temperature element should be set at 500 mm (20") from the bot-
tom of the tank regardless of probe type.
Endress+Hauser 11
Prothermo NMT532
WARNING
Avoid turbulence in the water so that WB (Water Bottom) sensor will not be damaged.
Datum Plate B
Slotted
300mm or more
Stilling Pipe
Max. 150mm
Max. 150mm
Datum Plate A
Slot-hole
300mm or more
Ø25mm Slotted
Stilling Pipe
Datum Plate
B
A
Installation Equipment Contents of Anchoring Hardware: Based on The Choice of "100: Mounting Attachment"
C: D: F:
A: B:
Anchor Weight Tension Wire + Tension Wire +
No Installation Anchor Weight
(Low Profile, Wire Hook + Wire Hook +
Material (High Profile, D120)
Hexagon H41) NPT1 Top Anchor R1 Top Anchor
Bottom hook Bottom hook Bottom hook Bottom hook Bottom hook
Anchor weight Anchor weight Base plate Base plate
Converter + Temp. Probe Sling wire Sling wire Wire hook Wire hook
NPT1 top anchor R1 top anchor
Tension wire Tension wire
12 Endress+Hauser
Prothermo NMT532
Anchor Weight
Element Position #1
(Bottom Element)
Bottom Hook
Clearance below
Temp. Sensor
500mm
400mm
Tank Floor
Figure 7: Anchor Weight
"High profile anchor weight" is the anchor method designed for converter + temperature probe.
"Low profile anchor weight" is the anchor method designed for small tank nozzle [max. 2 inches (50A)].
Temperature probes with anchor weights methods have a recommended clearance 400mm (16").
Stilling Well
(Min.Ø2")
Element Position #1
(Bottom Element)
Ø26mm
Clearance below
Bottom Hook
500mm
400mm
Tank Floor
Temperature probes with "wire hook + top anchor" and "stilling well" methods have a recommended
clearance 400mm (16").
*Refer to "Accessories" for details of anchor weight, wire hook, and top anchor.
Endress+Hauser 13
Prothermo NMT532
NMT532 - + + + + D/F
NMT532 - + + + + A
NMT532 - + + + + B
NMT532 - + + + + C
100mm
400mm
Electrical Compartment
Flange
Uppermost
Element
Flexible Tube
Element Position #1
Clearance: Bottom of
Tank to Bottom Hook Ø26mm(1.02”)
500mm
400mm
Anchor Weight
Anchor Weight (High Profile)
(Low Profile)
14 Endress+Hauser
Prothermo NMT532
Mounting on Pressurized Pressurized tank is required to install a stilling well to protect the probe from the pressure.
Tank
NMS5
NMT
Ball Valve
Reducer
Measuring Wire
Displacer
Stilling Well
CAUTION
• When the pressure inside the tank exceeds 1 bar (100KPa, 14.5psi), a stilling well which does not
have any holes or slits must be installed.
• NMT532 is installed in the stilling well from the top of the tank nozzle.
• Cover the bottom of the stilling well and weld it to protect the probe from the pressure.
Welding Part
Figure 12: Welding Part of Stilling Well
Endress+Hauser 15
Prothermo NMT532
Ground Terminal
FG
Screened Twisted Pair
Z1 AR1
or Steel armored Wire
Z2 Z3
NMS5 Terminal Since NMT 532 is an intrinsically safe instrument, the terminal connection to
Ex i side on local HART connection is allowed on the NMS terminal housing.
+ + COM +
1 L 4 Non IS HART 10 16 Operation 22 4 ... 20 mA
Power Supply Alarm Contact
L _ to NRF or Others _ HOIST _ Channel 2
ARS AC 85 ... 264V 50/60Hz 5 11 17 Contact 23
or Input
2 N DC 20 ... 62V AC20 ... 55V 6 + Digital Output 12
+ 18 STOP 24 +
Alarm Contact Ex i HART
G _ Rack Bus RS485, _ _ HART
ARS 7 13 19 25
Serial Pulse,or HART
+
3 G 8 14 + 20 + 4 ... 20 mA 26
N Alarm Contact
ARS 9
_ _ Alarm Contact 21
_ Channel 1
15
from NMT539
CAUTION
Do not connect NMT532 HART communication on terminals 4 & 5 on NMS5. These terminals are
designed to connect Ex d HART communication.
16 Endress+Hauser
Prothermo NMT532
NRF590 Terminal
RTD
i.s. Module Wiring
mA
24V
Internaly
HART Interconnected
Sensor as One HART
Fieldbus Loop
For Micropilot
S-series Only!
NOTICE
NRF590 has three sets of IS HART terminals. These three pairs are looped internally.
CAUTION
Do not connect signal HART lines from NMT532 to terminals 30 & 31. These terminals are designed
to supply drive power of FMR 53x series only.Mechanical Construction
Endress+Hauser 17
Prothermo NMT532
Mechanical Construction
NMT532 Dimensions
142.5mm
215mm
SUS304
SUS316
SUS316L
Bottom Hook
SUS316
Ø10
Ø26
18 Endress+Hauser
Prothermo NMT532
Human Interface
Operation Using FieldCare NMT532 can also be operated via FieldCare. These programs support
commissioning, securing of data, signal analysis, and documentation of the instruments.
Endress+Hauser 19
Prothermo NMT532
Ex Approval
Ex Approval Class
External Standards and IEC 61326 Appendix: A, Immunity according to table A-1
Guidelines
EN 60529
Protection class of housing (IP-code)
EN 61326
Emissions (equipment class B), compatibility (appendix A - industrial area)
20 Endress+Hauser
Prothermo NMT532
Order Information
NMT532
010 Approval:
7 FM IS Cl.I Div.1 Gr. C-D
8 CSA IS Cl.I Div.1 Gr. C-D
B ATEX Ex ia IIB T4 - T6
F IEC Ex ia IIB T4 - T6
G NEPSI Ex ia IIB T2-T6
Endress+Hauser 21
Prothermo NMT532
Accessories
Anchor Weight (High Pro- Mounting Attachment Option: B
file, D120) This high profile anchor type is designed for Converter + Temperature Probe Versions.
CAUTION
The lowest measuring element (lowest temperature measurement position) must be set at a position
of approximately 400mm (16") from the bottom of the tank.
Ensure that the opening size of the nozzle is 6 inches (150A) or more when installing the high profile
anchor weight from a nozzle at the top of the tank.
Material:
Weight : JIS SS400 (Mild Carbon Steel)
Ring: JIS SS400 (Mild Carbon Steel)
Weight
42mm (1.65")
Approx. 16kg
222mm (8.74")
180mm (7.09")
120mm (4.72")
Different dimensions, weight, and material for the anchor weight are also available.
Material:
Weight: JIS SS400 (Mild Carbon Steel)
Ring: JIS SS400 (Mild Carbon Steel)
Weight:
Approx. 12kg
1040mm (40.94")
41mm (1.61")
22 Endress+Hauser
Prothermo NMT532
21mm(0.83")
9mm(0.35")
150mm(5.91")
70mm (2.76”)
200mm(7.87”)
Actual tensioning can be completed with SUS316 stranded 3mm diameter tension wire between the
wire hook and the top anchor.
Material
Exterior: ADC (Aluminium)
Internal Parts : SUS316, Carbon Steel
Weight: Approx. 1.2kg
190mm (7.48")
52mm (2.05")
NOTICE
The standard process connection of the top anchor is R1 or NPT1 threaded connection.
Endress+Hauser 23
Prothermo NMT532
Documentation
Technical Information TI00452G
Proservo NMS5
TI00462G
Promonitor NRF560
Safety Instructions
NMT532 ATEX IEC NEPSI FM CSA
24 Endress+Hauser
Prothermo NMT532
Appendix
Stainless Steel Conversion The stainless steel material used in products of Endress + Hauser Japan normally have expressions
Table according to Japanese industrial standards, such as JIS or TIIS. Each country or region may have differ-
ent expressions.
The following conversion table contains the expression of equivalent stainless steel material based on
the chemical composition and mechanical properties.
Italy UNI X5 CrNi 1810 X2 CrNi 1911 X5 CrNiMo 1712 X2 CrNiMo 1712
/ 1713
Spain UNE X6 CrNi 19-10 X2 CrNi 19-10 X6 CrNiMo 17- X2 CrNiMo 17-
12-03 12-03
- ISO 11 10 20 19
NOTICE
Since each standard carries its own mechanical and scientific definition, some expressions may not
have the straight conversion from the Japanese standard. Consult with the local authority or legislature
to ensure the proper comparison with the applied standard prior to determining specification.
Endress+Hauser 25