0% found this document useful (0 votes)
153 views16 pages

Schneider Electric - Altistart-22 - ATS22C11Q

This product datasheet provides specifications for a soft starter for asynchronous motors called the Altistart 22 ATS22C11Q. The soft starter has a rated supply voltage of 230-440V, controls motors from 39-55kW, and has a factory setting current of 100A. It is intended to be used for pumps and fans and has protections for phase failure, overheating of the motor and starter, and IP20 degree of protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
153 views16 pages

Schneider Electric - Altistart-22 - ATS22C11Q

This product datasheet provides specifications for a soft starter for asynchronous motors called the Altistart 22 ATS22C11Q. The soft starter has a rated supply voltage of 230-440V, controls motors from 39-55kW, and has a factory setting current of 100A. It is intended to be used for pumps and fans and has protections for phase failure, overheating of the motor and starter, and IP20 degree of protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Product datasheet

Specifications

soft starter for asynchronous motor,


Altistart 22, control 230V, 230 to
440V, 39 to 55kW
ATS22C11Q

Main
Range Of Product Altistart 22

Product Or Component Type Soft starter

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product Destination Asynchronous motors

Product Specific Application Pumps and fans

Component Name ATS22

Network Number Of Phases 3 phases

[Us] Rated Supply Voltage 230...440 V - 15...10 %

Motor Power Kw 39 kW 230 V


55 kW 400 V
55 kW 440 V

Factory Setting Current 100 A

Power Dissipation In W 73 W for standard applications

Utilisation Category AC-53A

Type Of Start Start with torque control (current limited to 3.5 In)

Icl Starter Rating 110 A for connection in the motor supply line for standard applications

Ip Degree Of Protection IP20

Complementary
Assembly Style With heat sink

Function Available Internal bypass

Supply Voltage Limits 195…484 V

Supply Frequency 50...60 Hz - 10...10 %

Network Frequency 45...66 Hz

Device Connection In the motor supply line


To the motor delta terminals

[Uc] Control Circuit Voltage 230 V - 15...10 % 50/60 Hz

Control Circuit Consumption 20 W

Discrete Output Number 2

Discrete Output Type Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/
O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/
O

Minimum Switching Current 100 mA at 12 V DC (relay outputs)

Dec 13, 2023 1


AD
Maximum Switching Current 5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs
2 A 250 V AC inductive 0.4 20 ms relay outputs
2 A 30 V DC inductive 7 ms relay outputs

Discrete Input Number 3

Discrete Input Type (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm

Discrete Input Voltage 24 V <= 30 V

Discrete Input Logic Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA

Output Current 0.4...1 Icl adjustable

Ptc Probe Input 750 Ohm

Communication Port Protocol Modbus

Connector Type 1 RJ45

Communication Data Link Serial

Physical Interface RS485 multidrop

Transmission Rate 4800, 9600 or 19200 bps

Installed Device 31

Protection Type Phase failure: line


Thermal protection: motor
Thermal protection: starter

Marking CE

Type Of Cooling Forced convection

Operating Position Vertical +/- 10 degree

Height 356 mm

Width 150 mm

Depth 229.5 mm

Net Weight 18 kg

Motor Power Range Ac-3 30…50 kW at 200…240 V 3 phases


55…100 kW at 380…440 V 3 phases

Motor Starter Type Soft starter

Environment
Electromagnetic Compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5

Standards EN/IEC 60947-4-2

Product Certifications UL
CSA
GOST
C-Tick
CCC

Vibration Resistance 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6


1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6

Shock Resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27

Noise Level 56 dB

Pollution Degree Level 2 conforming to IEC 60664-1

Relative Humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3

2 Dec 13, 2023


AD
Ambient Air Temperature For -10…40 °C (without derating)
Operation 40…60 °C (with current derating 2.2 % per °C)

Ambient Air Temperature For -25…70 °C


Storage
Operating Altitude <= 1000 m without derating
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m

Packing Units
Unit Type Of Package 1 PCE

Number Of Units In Package 1 1

Package 1 Height 25.000 cm

Package 1 Width 33.000 cm

Package 1 Length 41.000 cm

Package 1 Weight 12.744 kg

Unit Type Of Package 2 P06

Number Of Units In Package 2 4

Package 2 Height 75.000 cm

Package 2 Width 60.000 cm

Package 2 Length 80.000 cm

Package 2 Weight 64.472 kg

Contractual warranty
Warranty 18 months

Dec 13, 2023 3


AD
Sustainability
Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-
class environmental performance. Green Premium promises compliance with the latest regulations,
transparency on environmental impacts, as well as circular and low-CO2 products.
Guide to assessing product sustainability is a white paper that clarifies global eco-label
standards and how to interpret environmental declarations.

Well-being performance

 Mercury Free

 Rohs Exemption Information Yes

Reach Regulation REACh Declaration

Eu Rohs Directive Pro-active compliance (Product out of EU RoHS legal scope)

EU RoHS Declaration

China Rohs Regulation China RoHS declaration

Weee The product must be disposed on European Union markets following specific waste
collection and never end up in rubbish bins

4 Dec 13, 2023


AD
Product datasheet ATS22C11Q
Dimensions Drawings

Frame Size C

Dimensions

Dec 13, 2023 5


AD
Product datasheet ATS22C11Q
Mounting and Clearance

Precautions

Standards
The Altistart 22 soft starter is compliant with pollution Degree 2 as defined in NEMA ICS1-1 or IEC 60664-1.
For environment pollution degree 3, install the Altistart 22 soft starter inside a cabinet type 12 or IP54.

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH


ATS22 soft starters are open devices and must be mounted in a suitable enclosure.

Failure to follow these instructions will result in death or serious injury.

Air Circulation
Leave sufficient free space to help the air required for cooling purposes to circulate from the bottom to the top of the
unit.

Overheating
To avoid the soft starter to overheat, respect the following recommendations:

• Mount the Altistart 22 Soft Starter within ± 10° of vertical.


Do not locate the Altistart 22 Soft Starter near heat radiating elements.
• Electrical current through the Altistart 22 Soft Starter will result in heat losses that must be dissipated into the
• ambient air immediately surrounding the soft starter. To help prevent a thermal fault, provide sufficient
enclosure cooling and/or ventilation to limit the ambient temperature around the soft starter.
• If several soft starters are installed in a control panel, arrange them in a row. Do not stack soft starters. Heat
generated from the bottom soft starter can adversely affect the ambient temperature around the top soft
starter.

6 Dec 13, 2023


AD
Product datasheet ATS22C11Q

Mounting

Connection Between the Fan and the Altistart 22 Soft Starter

1 Altistart 22 Soft Starter

2 Fan

Dec 13, 2023 7


AD
Product datasheet ATS22C11Q

Wall mounted or Floor-standing Enclosure with IP 23 Degree of protection

Introduction
To help proper air circulation in the soft starter, grilles and forced ventilation can be installed.

Ventilation Grilles

Forced Ventilation Unit

8 Dec 13, 2023


AD
Product datasheet ATS22C11Q
Connections and Schema

Power Terminal

Bar Style

b 20 mm (0.79 in)

Bar a 5 mm (0.2 in)

Bolt M8 (0.31 in)

Size 95 mm²
Power supply and output to motor
Gauge 250 MCM

Cable and protective cover Protective cover LA9F702

18 N.m
Tightening torque
157.5 lb.in

Power connections, minimum required wiring section


IEC cable UL cable
mm² (Cu 70°C/158°F) (1) AWG (Cu 75°C/167°F) (1)

35 1/0

Dec 13, 2023 9


AD
Product datasheet ATS22C11Q

230 Vac control, logic Inputs (LI) 24 Vdc, 3-wire control

With Line Contactor, Freewheel or Controlled Stop

10 Dec 13, 2023


AD
Product datasheet ATS22C11Q

230 Vac control, logic Inputs (LI) 24 Vdc, 2-wire control,freewheel stop

Dec 13, 2023 11


AD
Product datasheet ATS22C11Q

Connection in the motor delta winding in series with each winding

Wiring
ATS22 soft starters connected to motors with the delta connections can be inserted in series in the motor windings.
The following wiring requieres particular attention. It is documented in the Altistart 22 Soft start - soft stop unit user
manual. Please contact Schneider Electric commercial organisation for further informations.

Example
A 400 V - 110 kW motor with a line current of 195 A (nominal current for the delta connection). The current in each
winding is equal to 195/1.5 or 130 A. The rating is determined by selecting the soft starter with a permanent nominal
current (ICL) just above this current.

12 Dec 13, 2023


AD
Product datasheet ATS22C11Q
Performance Curves

Motor Thermal Protection - Cold Curves

Curves

A Class 10

B Class 20

C Class 30

Trip time for a Standard Application (Class 10)

3.5 ln

32 s

Trip time for a Severe Application (Class 20)

Dec 13, 2023 13


AD
Product datasheet ATS22C11Q

3.5 ln

63 s

Trip time for a Severe Application (Class 30)

3.5 ln

95 s

14 Dec 13, 2023


AD
Product datasheet ATS22C11Q

Motor Thermal Protection - Warm Curves

Curves

A Class 10

B Class 20

C Class 30

Trip time for a Standard Application (Class 10)

3.5 ln

16 s

Trip time for a Severe Application (Class 20)

3.5 ln

Dec 13, 2023 15


AD
Product datasheet ATS22C11Q

32 s

Trip time for a Severe Application (Class 30)

3.5 ln

48 s

16 Dec 13, 2023


AD

You might also like