BELL-HOUSING & COUPLING SIZING
A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING
DATA REQUIRED
- Electric motor power/motor size
- Manufacturer and pump type
TO VERIFY:
1 - Pump and motor shaft dimensions (see electric motor data sheet)
2 - Shaft and flange pump (see pump data sheet)
Example:
- Electric motor 2.2 kW - size 100-112
- Atos pump code PFE31 - Shaft 1
Nr.2ø11
9.5
ø82.55
ø28 - key 8 60 57.5 ø106.4
code M05 see page 18
Case A
Solution with monobloc bell-housing series LMC/LDC
Pages 63 ÷ 69 for IEC Electric motor size 100-112 - LMC250
Bell-Housing’s length calculation
LMC 250 bell-housing with height ≥ 135.5 - LMC250AFSQ
- H = 60 + 18 + 57.5 = 135.5 mm (18 = Sp spider - see page 31) The bell-housing code must be completed with pump drilling code (see pages 48-49).
For the specific case:
- Choose type of bell-housing (LMC - LMS): Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
For monobloc bell-housing LMC/LDC series see pages 63 ÷ 69
For Low noise bell-housing LMS/LDS series see pages 71 ÷ 77 Definitive bell-housing code LMC250AFSQ060
For Multi-components 2-3 bell housing series see pages 79 ÷ 99
Case B
Note: Solution with low noise bell-housing series LMS/LDS
The length of bell-housing must be ≥ than the length calculated (135.5 mm)
Pages 71 ÷ 77 for IEC Electric motor size 100-112 - LMS250
The bell-housing code must be completed with pump drilling code (see pages 48-49).
For the specific case:
Spigot hole 82.55 - PCD 106.4 - Nr.2 holes M10 : Drilling code 060
Introduction 10
BELL-HOUSING & COUPLING SIZING
A GUIDE TO SELECT THE CORRECT BELL-HOUSING AND DRIVE COUPLING
Coupling selection
Motor half-coupling (see page 26)
For IEC Electric motor size 100/112, the half-coupling is SGEA21M05060FG
Pump half-coupling
Choose the drilling code - see pages 18-19 for shaft 19.05 - key 4.76 - code: G01
Note: for multi pumps we recommend to use a specific support on the base of the pump’s dimensions and weight.
11 Introduction
BELL-HOUSING & COUPLING SIZING Selection Software
Introduction 12
Selection Software BELL-HOUSING & COUPLING SIZING
Step 5 Push “CLICK HERE TO PROCEED”, then choose best solution for your application.
Step 7
Download PDF
Datasheet and “DXF Drawing” of your selection
194
A
Questo documento e' di proprieta' della MP filtri S.p.A. - Senza autorizzazione scritta della stessa non potra' essere utilizzato per la costruzione dell'oggetto rappresentato ne venire conunicato a terzi . La societa' proprietaria tutela i propri diritti a rigore di legge .
All proprietary rights reserved by MP filtri S.p.A. - This drawing shall not be reproduced, or in any way utilized, for the manufacture of the component or unit herein illustrated and must not be released to other parties, without written consent . Any infringement will be legally pursued .
31
Nr. 4 holes M16
109 26 45
Ø25 - Ch.8
54,5
Ø 4 2 - C h. 12
8 M
Ø350
Ø250
Ø100
Sec. A-A
Ø140 A
Ø 300
Prodotto/Product Disegnato/Drawn. Data/Date Per errori ammissibili di quote
AKMM05Z0007
senza tolleranze e per altre
20/02/2017 prescrizioni generali vedi
Complete kit for: Materiale/Material
Controllato/Checked Data/Date UNI EN 22768-1/1996 - f
Scala/Scale
B.O.M. 1:2
ITEM QTY CODE DESCRIPTION Trattamento/Treatment
13 Introduction
GENERAL INFORMATION NOISE
Noise is a particularly pervasive problem so much so that there have been statutory regulations in place now for some years, designed to limit harmful
occupational exposure.
Many of the machines used in industry today are equipped with oil-hydraulic systems, which happen to be a major source of noise.
BELL-HOUSING
ELECTRIC MOTOR
PUMP
RECEIVER
- Human ear
- Sound level meter
Bell-Housing 46
ASSEMBLY OF MOTOR AND PUMP UNIT
Low noise bell-housing will help to attenuate the transmission of vibrations and the emission of noise generated by the system.
Self-evidently, however, the mere adoption of a low noise bell-housing will achieve little unless the motor and pump are correctly installed on the machine
or on the tank of the hydraulic power unit.
Should be followed in order to achieve best possible results and correct installation:
1 MOTOR AND PUMP UNIT MOUNTED 2 MOTOR AND PUMP UNIT MOUNTED
HORIZONTALLY ON OIL TANK LID HORIZONTALLY ON MACHINE
- The suction pipe attached to the pump must be rigid and fitted using a resilient - As a matter of good practice, the oil tank and motor-pump unit should be
bulkhead flange of the FTA series, which helps to cushion the vibrations mounted on a single supporting frame of strength sufficient to support the load.
propagated between the pipe and the tank lid.
If pipes need to be bent, the radius of curvature must be at least 3 times the - If the hydraulic system is fitted with a side-mounted filter, the suction pipeline
pipe diameter. to the pump must be flexible and long enough to include bends with the
Do not use elbow fittings, as these will significantly increase pressure losses. minimum radius of curvature recommended by the manufacturer.
- The pressure pipeline of the pump must be flexible and long enough to - If the suction filter is not side mounted, the pipeline should be rigid and
include bends with the minimum radius of curvature recommended by the installed in conjunction with a compensating coupling.
manufacturer for the specified operating pressure.
- The pressure pipeline of the pump must be flexible, and long enough to include
- The return pipeline running from the service to the filter must be flexible. bends with the minimum radius of curvature recommended by the manufacturer
Where oil is returned directly to the tank of the hydraulic power unit through for the specified operating pressure.
a rigid pipe, it is advisable to use a resilient bulkhead flange of the FTR series,
which helps to cushion the vibrations propagated between the pipe and - The return pipeline running from the service to the filter must be flexible.
the tank lid. Where oil is returned directly to the tank of the hydraulic power unit through
a rigid pipe, it is advisable to use a resilient bulkhead flange of the FTR series,
- Anti-vibration devices (resilient mounts or damping rods) must be located which helps to cushion the vibrations propagated between the pipe
under the feet of the electric motor or the PDM foot brackets, depending on and the tank lid.
the mounting position of the motor.
- Anti-vibration devices (resilient mounts or damping rods) must be located
- The lids of hydraulic oil tanks must be sturdy enough to support the load under the feet of the electric motor or the PDM foot brackets, depending
they carry. on the mounting position of the motor.
FINAL CONSIDERATION
For best results, in any event, the motor-and-pump unit should be incorporated into the hydraulic system in such a way that no one component is rigidly associated
with another, resulting in the propagation of vibration, and consequently noise.
Note: The above guidelines are indicative only and subordinate to the solutions adopted ultimately by design engineers.
47 Bell-Housing
GENERAL INFORMATION PUMP INTERFACE CODES
56 76.00 M6 4 234 -
hole
85.00 M8 4 ISO3019-2-63-B4
hole
90.00 M8 4 271 -
65 90.00 M8 4 073 -
70 84.00 ø7 4 289 -
Valid configuration for bell-housing 71.8 88.90 M10 4 047 -
from ø450 to ø660 75 102.00 M10 4 139 -
100.00 M8 4 024 ISO3019-2-80-B4
103.20 M8 2 045 ISO3019-2-80-B2
100.00 ø11 4 059 -
100.00 M10 2 061 -
110.00 M10 2 063 -
140.00 M10 2 064 -
115.00 M10 2 065 -
Bell-housing with nr. 2 holes
100.00 M10 4 067 -
at pump interface + 22.5°
PCD
80
compared to through holes at 106.40 M10 2 083 -
motor interface. 130.00 M8 4 087 -
100.00 ø8,5 4 093 -
Spigot
hole
140.00 M8 4 088 -
92
145.00 M10 4 089 -
“-”: configuration out of ISO & SAE Standard
Bell-Housing 48
PUMP INTERFACE CODES GENERAL INFORMATION
Spigot hole D Nr. holes Code Type Spigot hole D Nr. holes Code Type
[mm] PCD [mm] PCD
115.00 M8 4 137 - 130 165.00 M10 4 253 -
95
127.00 M10 4 131 - 160.00 M10 4 151 -
135
98.4 125.00 ø11 4 128 - 175.40 M12 4 220 -
125.00 M10 2 023 ISO3019-2-100-B4 180.00 M14 4 077 ISO3019-2-140-B4
125.00 M10 4 025 ISO3019-2-100-B2 180.00 M12 2 081 -
125.00 ø11 4 031 - 165.00 M10 4 157 -
140
125.00 M5 4 032 - 200.00 M16 4 176 ISO3019-2-140-B2
190.00 ø15 4 038 - 165.00 ø11 4 223 -
125.00 ø13 4 041 - 180.00 M16 2 232 -
100 125.00 M12 2 071 - 150 185.00 M16 4 069 -
140.00 M12 2 072 - 228.60 M16 4 022 -
146.00 M12 2 075 - 228.60 M18 2 090 -
126.00 M10 2 106 - 228.60 M18 4 108 -
120.00 M8 4 122 - 152.4 217.50 ø17 4 118 -
160.00 M10 4 141 - 228.60 M20 2 166 SAE D 152-2
150.00 M10 4 150 - 228.60 M20 4 192 SAE D 152 -4
161.50 M12 4 029 - 190.50 M8 4 207 -
146.00 M12 2 070 SAE B 101-2 200.00 M16 4 027 ISO3019 - 2 -160 B4
101.6 127.00 M12 4 125 - 200.00 ø17 4 035 -
146.00 M10 2 159 - 200.00 M16 2 091 -
127.00 M10 4 224 - 224.00 M20 2 092 ISO3019 - 2 -160 B2
105 146.00 M12 2 076 - 160 200.00 M12 2 107 -
175.00 M10 4 110 - 230.00 M22 4 111 -
130.00 M8 4 154 - 185.00 M12 4 152 -
110 200.00 M10 4 202 - 224.00 M16 4 184 -
135.00 M10 4 219 - 230.00 ø22 4 228 -
145.00 M12 4 273 - 162 188.00 M12 4 263 -
140.00 M12 2 074 - 317.35 M20 4 143 SAE E 165 - 4
112 140.00 M10 2 138 - 317.35 M24 2 145 SAE E 165 - 2
165.1
130.00 M10 4 264 - 229.00 M20 4 201 -
115 180.00 M12 4 198 - 317.35 M18 4 204 -
116 160.00 M14 2 084 - 200.00 M12 4 153 -
175
210.00 M16 2 094 - 230.00 M18 2 185 -
120 145.00 M10 4 155 - 350.00 M24 4 146 SAE F 177 - 4
150.00 ø13 4 267 - 177.8 216.00 M12 4 222 -
160.00 M12 4 026 ISO3019-2-125-B4 350.00 M24 2 203 SAE F 177 - 2
160.00 ø13 4 033 - 216.00 ø13 4 055 -
160.00 M12 2 079 - 216.00 M16 4 078 -
180.00 M16 2 082 ISO3019-2-125-B2 224.00 M16 4 112 ISO3019 - 2 -180 B4
180
155.00 M10 4 102 - 216.00 M12 4 132 -
125 160.00 ø17 4 113 - 215.00 M22 4 148 -
200.00 M12 4 114 - 230.00 M22 4 226 -
181.20 M16 2 136 - 250.00 M20 4 028 ISO3019 - 2 -200 B4
200.00 M16 4 200 - 250.00 ø22 4 095 -
200
180.00 ø20 4 215 - 280.00 M24 2 117 -
170.00 ø18 4 237 - 230.50 M12 4 214 -
161.50 M12 4 021 - 203.2 254.00 M14 4 210 -
127 181.20 M16 2 080 SAE C 127-2 205 240.00 M16 4 133 -
161.50 M14 4 140 - 280.00 M20 4 144 ISO3019 - 2 -224 B4
224
165.00 ø11 4 054 - 280.00 ø22 4 205 -
150.00 M12 4 068 - 310.00 M24 4 238 -
250
130 181.20 M16 2 085 - 315.00 M20 4 282 ISO3019 - 2 -250 B4
165.00 M12 4 124 - 355.00 M16 4 233 -
275
165.00 M14 4 135 - 355.00 ø18 4 281 -
“-”: configuration out of ISO & SAE Standard “-”: configuration out of ISO & SAE Standard
49 Bell-Housing
Bell-Housing 50
Bell-Housing
LMG series
IEC electric motor range from size 63 up to size 225
51 Bell-Housing
LMG GENERAL INFORMATION
Technical data
Materials Temperature
- Bell-housing: Pressure die casting Aluminium From -30 °C to +80 °C
- Center ring: Galvanized Steel
- Gasket: Special paper - Guarnital
Note
Compatibility with fluids For temperatures outside this range, contact
MP Filtri Technical and Sales Department
Modular bell-housing components compatible for use with:
- Mineral oils types HH-LL-HM-HR-HV-HC, to ISO 6743/4 standard
- Water based emulsions types HFAE-HFAS, to ISO 6743/4 standard
- Water glycol type HFC, to ISO 6743/4 standard: ask for anodized version
Special Applications
Any applications not covered by the normal indications
contained in this catalogue must be evaluated and approved
by MP Filtri Technical and Sales Department
Bell-Housing 52
VERSIONS LMG
53 Bell-Housing
LMG
Designation & Ordering code
BELL-HOUSING LMG
Bell-Housing series and size Configuration example: LMG140 M FS200 4E DI
LMG140 LMG250 LMG450
LMG141 LMG251 LMG550
LMG160 LMG300 LMG660
LMG161 LMG350
LMG200 LMG351
LMG201 LMG400
Product revision code
M
Pump flange identification code
FS200 See page 55
Versions
4S 4 through holes + 4 threaded holes, motor interface without coupling removal ring
4E 4 through holes + 4 threaded holes, motor interface with coupling removal ring
8S 8 through holes, motor interface without coupling removal ring
8E 8 through holes, motor interface with coupling removal ring
Options
DI Drain hole + inspection hole
AN Black anodized finish
SA Motor interface with clearance holes
Pxx Customer specification
COUPLING KIT
Motors identification code Configuration example: AKG02 FS200 Z
Size Size
02 63 B3-B5 13 180 B3-B5
03 71 B3-B5 43 63 B14
04 80 B3-B5 44 71 B14
05 90 B3-B5 45 80 B14
07 100/112 B3-B5 46 90 B14
11 132 B3-B5 48 100/112 B14
12 160 B3-B5
Pumps flange identification code
FS200 See page 55
Product revision code
Z
Note:
- Bell-Housings with DI options are supplied complete with threaded closure plug.
- Bell-Housing with 4E/8E version are supplied with center ring mounted.
- For product range codes see pages 58 ÷ 60
Bell-Housing 54
LMG
Dimensions
Spigot
hole Hole
Key
d
55 Bell-Housing
LMG
Dimensions
Bell-housing
IEC - Electric motors Bell-housing Dimensions [mm] On request Weight
Motor size Shaft end [d x l] code D1 D2 D3 D4 H1 H2 F P H3 D6 [kg]
63 - B14 11x23 LMG090 60 75 90 63 60 7 - 6 40 1/2” 0.30
71 - B14 14x30 LMG105 70 85 105 74 67 8 - 7 40 1/2” 0.35
80 - B14 19x14 LMG120 80 100 120 84 87 9 - 7 45 1/2” 0.40
63 - B3/B5 11x23 LMG140 95 115 140 100 60 13 M8 9 40 1/2” 0.35
63 - B3/B5 11x23 LMG141 95 115 140 100 95 13 M8 9 50 1/2” 0.40
71 - B3/B5 14x30 LMG160 110 130 160 110 70 15 M8 9 40 1/2” 0.44
71 - B3/B5 14x30 LMG161 110 130 160 110 105 15 M8 9 50 1/2” 0.50
80 - B3/B5 19x14 LMG200 130 165 200 135 87 18 M10 11 45 3/4” 0.68
90 - B3/B5 24x50 LMG201 130 165 200 135 95 18 M10 11 50 3/4” 0.80
100-112 - B3/B5 28x60 LMG250 180 215 250 185 105 22 M12 14 70 3/4” 1.16
100-112 - B3/B5 28x60 LMG251 (*) 180 215 250 185 126 22 M12 14 70 3/4” 1.80
Bell-Housing 56
LMG
Dimensions
Inspection Hole
Plastic threaded plug mounted
(protection according
to DIN EN 292 part 2)
“Safety of machines”
ø10
Bell-housing
IEC - Electric motors Bell-housing Dimensions [mm] On request Weight
Motor size Shaft end [d x l] code D1 D2 D3 D4 H1 H2 F P H3 D6 [kg]
132 38x80 LMG300 230 265 300 235 145 23 M12 14 80 1” 2.55
160 42x110 LMG351 250 300 350 255 179 31 M16 18 100 1” 4.90
180 48x110 LMG351 250 300 350 255 179 31 M16 18 100 1” 4.90
57 Bell-Housing
LMG TABLE OF COMBINATION
Note:
- For bell-housing dimensions see pages 56-57.
- For coupling dimensions see “Half-couplings” section on pages 26-27.
Bell-Housing 58
TABLE OF COMBINATION LMG
IEC Motors B3/5 - standard gear pump
IEC - Electric motors Pump Components
Motor Shaft end identification Bell-Housing Motor half-coupling Spider Pump half-coupling Complete Complete
size [d x l] code code code code code kit code coupling kit code
FSZGR LMG351MFSZGR4S SGEA51FSZGR AKA12FSZGRZ4S AKG12FSZGRZ
FS200 LMG351MFS2004S SGEA51FS200 AKA12FS200Z4S AKG12FS200Z
FSZFR LMG351MFSZFR4S SGEA51FSZFR AKA12FSZFRZ4S AKG12FSZFRZ
FS25T LMG351MFS25T4S/4E SGEA51FS300 AKA12FS25TZ4S/4E AKG12FS300Z
160 42x110 FS300 LMG351MFS3004S/4E SGEA51M07109FG EGE 5 SGEA51FS300 AKA12FS300Z4S/4E AKG12FS300Z
FS3M0 LMG351MFS3M04S/4E SGEA51FS300 AKA12FS3M0Z4S/4E AKG12FS300Z
FS3T0 LMG351MFS3T04S/4E SGEA51FS300 AKA12FS3T0Z4S/4E AKG12FS300Z
FS35M LMG351MFS35M4S/4E SGEA51FS350 AKA12FS35MZ4S/4E AKG12FS350Z
FS350 LMG351MFS3504S/4E SGEA51FS350 AKA12FS3504ZS/4E AKG12FS350Z
FSZGR LMG351MFSZGR4S SGEA51FSZGR AKA13FSZGRZ4S AKG13FSZGRZ
FS200 LMG351MFS2004S SGEA51FS200 AKA13FS200Z4S AKG13FS200Z
FSZFR LMG351MFSZFR4S SGEA51FSZFR AKA13FSZFRZ4S AKG13FSZFRZ
FS25T LMG351MFS25T4S/4E SGEA51FS300 AKA13FS25TZ4S/4E AKG13FS300Z
180 48x110 FS300 LMG351MFS3004S/4E SGEA51M08109FG EGE 5 SGEA51FS300 AKA13FS300Z4S/4E AKG13FS300Z
FS3M0 LMG351MFS3M04S/4E SGEA51FS300 AKA13FS3M0Z4S/4E AKG13FS300Z
FS3T0 LMG351MFS3T04S/4E SGEA51FS300 AKA13FS3T04ZS/4E AKG13FS300Z
FS35M LMG351MFS35M4S/4E SGEA51FS350 AKA13FS35MZ4S/4E AKG13FS350Z
FS350 LMG351MFS3504S/4E SGEA51FS350 AKA13FS350Z4S/4E AKG13FS350Z
FS200 LMG400MFS2004E SGEA51FS200 AKA16FS200Z4S AKG16FS200Z
FS300 LMG400MFS3004E SGEA51FS300 AKA16FS300Z4E AKG16FS300Z
FS3M0 LMG400MFS3M04E SGEA51FS300 AKA16FS3M0Z4E AKG16FS300Z
200 55x110 FS35M LMG400MFS35M4E SGEA51M09109FG EGE 5 SGEA51FS350 AKA16FS35MZ4E AKG16FS350Z
FS350 LMG400MFS3504E SGEA51FS350 AKA16FS350Z4E AKG16FS350Z
FSZFR LMG400MFSZFR4S SGEA51FSZFR AKA16FSZFRZ4E AKG16FSZFRZ
FSZGR LMG400MFSZGR4S SGEA51FSZGR AKA16FSZGRZ4E AKG16FSZGRZ
FS300 LMG450MFS3004E SGEG60FS300 AKA18FS300Z4E AKG18FS300Z
FS3MO LMG450MFS3MO4E SGEG60FS300 AKA18FS3M0Z4E AKG18FS300Z
225 60x140 FS35M LMG450MFS35M4E SGEG60M10110 EGE 6 SGEG60FS350 AKA18FS35MZ4E AKG18FS350Z
FS350 LMG450MFS3504E SGEG60FS350 AKA18FS350Z4E AKG18FS350Z
FSZGR LMG450MFSZGR4S SGEG60FSZGR AKA18FSZGRZ4E AKG18FSZGRZ
FS300 LMG550MFS3004E SGEG60FS300 AKA20FS300Z4E AKG20FS300Z
FS3MO LMG550MFS3MO4E SGEG60FS300 AKA20FS3M0Z4E AKG20FS300Z
250 65x140 FS35M LMG550MFS35M4E SGEG60M11140 EGE 6 SGEG60FS350 AKA20FS35MZ4E AKG20FS350Z
FS350 LMG550MFS3504E SGEG60FS350 AKA20FS350Z4E AKG20FS350Z
FSZGR LMG550MFSZGR4S SGEG60FSZGR AKA20FSZGRZ4E AKG20FSZGRZ
FS300 LMG550MFS3004E SGEG80FS300 AKA22FS300Z4E AKG22FS300Z
FS3MO LMG550MFS3MO4E SGEG80FS300 AKA22FS3M0Z4E AKG22FS300Z
280 75x140 FS35M LMG550MFS35M4E SGEG80M12140 EGE 8 SGEG80FS350 AKA22FS35MZ4E AKG22FS350Z
FS350 LMG550MFS3504E SGEG80FS350 AKA22FS350Z4E AKG22FS350Z
FSZGR LMG550MFSZGR4S SGEG80FSZGR AKA22FSZGRZ4E AKG22FSZGRZ
FS300 LMG660MFS3004E SGEG80FS300 AKA26FS300Z4E AKG26FS300Z
FS3MO LMG660MFS3MO4E SGEG80FS300 AKA26FS3M0Z4E AKG26FS300Z
315 80x170 FS35M LMG660MFS35M4E SGEG80M13170 EGE 8 SGEG80FS350 AKA26FS35MZ4E AKG26FS350Z
FS350 LMG660MFS3504E SGEG80FS350 AKA26FS350Z4E AKG26FS350Z
FSZGR LMG660MFSZGR4S SGEG80FSZGR AKA26FSZGRZ4E AKG26FSZGRZ
Note:
- For bell-housing dimensions see pages 56-57.
- For coupling dimensions see “Half-couplings” section on pages 26-27.
59 Bell-Housing
LMG TABLE OF COMBINATION
Note:
- For bell-housing dimensions see pages 56-57.
- For coupling dimensions see “Half-couplings” section on pages 26-27.
Bell-Housing 60
ACCESSORIES LMG
Dimensions
CENTER RING
Center ring Dimensions [mm]
code D1 D2 Thk.
ANC01FS100 50 25.4 1.0
ANC01FS1M0 50 30.0 1.0
ANC02FS200 72 36.5 2.0
ANC03FS200 88 36.5 2.0
ANC03FS300 88 50.8 2.5
ANC03FS350 88 60.3 2.5
ANC04FS300 115 50.8 3.5
ANC04FS350 115 60.3 3.5
ANCA001 42 22.0 1.0
ANCD005 85 50.8 2.5
Thk.
GASKET
Spigot
Hole Thk. hole Hole Thk.
61 Bell-Housing