This document provides information on a current transformer made by Mehru Electrical & Mechanical Engineers Private Limited. It has the following key details: - Rated for 33kV nominal system voltage - Has 2 cores, each with a primary current of 1000A and secondary current of 1A - Rated short time current is 25kA for 1 second - Insulation level is 70/170kV and is suitable for hot line washing - Manufactured in 2018 in India

Uploaded by

sparkCE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
333 views1 page

Name Plate

This document provides information on a current transformer made by Mehru Electrical & Mechanical Engineers Private Limited. It has the following key details: - Rated for 33kV nominal system voltage - Has 2 cores, each with a primary current of 1000A and secondary current of 1A - Rated short time current is 25kA for 1 second - Insulation level is 70/170kV and is suitable for hot line washing - Manufactured in 2018 in India

Uploaded by

sparkCE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MEHRU LIVE TANK CURRENT TRANSFORMER

MADE TO IS: 2705/1992


HIGHEST SYSTEM VOLTAGE 36 kV INSULATION LEVEL 70/170 kV
SUITABLE FOR HOT LINE WASHING
RATED S.T.C 25kA for 1 second RATED FREQUENCY 50Hz
NOMINAL SYSTEM VOLTAGE 33 kV CORE 1 CORE 2
CONNECTION DIAGRAM
PRIMARY (Amp) 1000 1000
P1 P2
RATIO
SECONDARY (Amp) 1 1
PRIMARY
SECONDARY TERMINALS 1S1-1S2 2S1-2S2
RATED BURDEN IN V.A

115 ±10
10 VA 10 VA
ACCURACY CLASS 0.2S 0.2S
ALF / ISF <5 <5
Min Knee point voltage ---- ----
1S1 1S2 2S1 2S2
Max Rct at 75 DEG C ---- ----
Max Iext at VK ---- ---- SECONDARY
Year OF MANUFACTURE 2018 SERIAL NO.
RATED CONT. THERMAL CURRENT 125% OF RATED PRIMARY CURRENT
MADE IN INDIA BY * TOTAL WEIGHT 95 Kgs APPROX., TOTAL OIL QTY.- 15 LITRES APPROX. CAUTION:
* TOTAL CREEPAGE DISTANCE 900 mm (Min) 1. Tan delta Terminal to be earth when CT is Charged.
2. Secondary Terminals must be short circuited before
the burden is disconnected.
E-1247 RIICO INDUSTRIAL AREA , PHASE I , EXT GHATAL , BHIWADI-301 019
195 ±20
MEHRU ELECTRICAL & MECHANICAL
MANUFACTURER :
MEHRU
ENGINEERS PRIVATE LIMITED.
NOTES :- CUSTOMER NLC INDIA LTD
(Formerly Neyveli Lignite Corporation Limited)
1. MIN. THICKNESS OF RATING PLATE :- 1.2 mm EPC
CONTRACTOR LNV TECHNOLOGY PVT.LTD.
ITCOT Consultancy and Services Ltd.
2. MATERIAL :-ALU. ANODISED. CONSULTANT
( Joint Venture of SIDBI, IFCI, SIPCOT, TIIC, SIDCO & Banks )
PROJECT 100 MW (AC) Grid Interactive Solar PV Power Project
3. SERIAL NO. SHALL BE ENGRAVED BEFORE DISPATCH At MARANTHAI VILLAGE, ALANGULAM TALUK, TIRUNELVELI DISTRICT, TAMILNADU.
TITLE NAME PLATE DRAWING FOR 33kV OUT
DOOR OIL COOLED CURRENT TRANSFORMER
RATIO : 1000/1-1A
1. ALL DIMENSIONS IN mm 3 of 4
2. TOLERANCE WHEREVER NOT INDICATED ±5% DRAWN AKASH SPS KESAVAN DATE 24-07-2018 Sheet Size Rev
CHECKED BLS APPROVED GKR / RS SCALE NTS A1 0
DRAWING No. ME-33CT-NP-8662-02
00 FOR APPROVAL 24.07.18 AKASH 24.07.18 BLS 24.07.18 SPS 24.07.18
SUBMISSION NAME DATE NAME DATE NAME DATE
RELEASED FOR
REV. DESCRIPTION DATE
DRAWN CHECKED APPROVED Preliminary Information Tender Approval Construction As built