Introduction
Design criteria
Layout
Hydraulic Calculation
Main Pipe Hydraulic Calculation
Infield Hydraulic Calculation
BOQ
Infield equipments
Mail pipe equipments
Fittings
Report
Drawings
Introdaction
Upper Guder Multi-purpose project covers ~5000 ha of
land.
dissected undulating topographic land features that is
why pressurized irrigation is selected (2068ha surface to
4926ha Pressurized)
The appropriate working papers contain a background
material and references to specific projects have been
given in the main report.
The project area lies between 8O 43’ to 8O 57’ Northing
and 37O 29’ to 37O 49’ Easting in Oromia Regional State
and in two Woredas namely Guder and Dere/Tikur
Inchini
Project area location Map
Design Criteria
Design Criteria preparation was made based on :-
Specific to the project and used for design of
dragline sprinkler,
Due attentions was made to uniformity,
adequacy, efficiency, manageability,
sustainability, and cost-effectiveness
engineering security coefficients and
considerations
Input Data for Drag line Sprinkler
Irrigation
The followings are used for the design work:-
Soil
Climate
Topography
Agronomy
Suitability map
Lateral pipe
Layout of Upper Guder Project-2015.10.20.dwg
Main and sub main pipe line Hydraulic
calculation
Pressure calculation
Discharge calculation
MCP Calculation.xls
POC-1.xls
Infield Hydraulic Design
Pressure calculation
Discharge calculation
A01.xls
Based up on the above facts Sprinkler
Discharge is computed as:-
Fittings