3.spirit Level
3.spirit Level
Straight edge
2. True running of main spindle:- The test mandrel is placed in the main spindle and
test is conducted on the surface of mandrel. If dial gauge shows any deviation in the
reading then it is said that the main spindle is not running in the proper way. If dial
gauge should not deviate then it is said that the main spindle is running in the proper
way.
3. Parallelism of main spindle to saddle movement:- If the axis of spindle is not
parallel to the saddle movement then it is not possible to get req. dimension of work
piece while doing the operation on lathe. The spindle is moved and the deviations in the
readings of dial gauge are noted.
4. Parallelism of tailstock guide ways to saddle movement:- To check the parallelism
of guide ways with the saddle movement in both vertical and horizontal directions, the
dial indicator is held on the spindle and block is moved simultaneously any deviation in
reading of dial gauge is noted if no deviation in the reading then tail stock guide ways is
parallel to saddle movement otherwise it is not parallel to saddle movement.