100% found this document useful (1 vote)
429 views3 pages

Sertifikat Kalibrasi - Timbangan (CAS)

kalibrasi timbangan (cas)

Uploaded by

Sunartomo Ir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
100% found this document useful (1 vote)
429 views3 pages

Sertifikat Kalibrasi - Timbangan (CAS)

kalibrasi timbangan (cas)

Uploaded by

Sunartomo Ir
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
> PT. EASTERN PRO ENGINE! | ioe RESIDENCE Order Number 45.01.2466 ee Received Dato December 27, 2023 Customer PT. Hutama - Adhi- Abipraya, KS |e Address Jalan Poros KKT Kariangau Equipment Name: Timbangan Environment Condition of Calibration Manufacturer cas. Temperature (297 + 08)" Type Swett Humidity (88 + 28) | %RH Serial Number 220886401 Reference EPE.03.02.01.02.01.01 Capacity 30 kg Calibration Date December 27, 2023, Resolution 0.001 kg Calibration Location: Laboratorium Calibration Report 41. Repeatability of Measurement Standard indication] Repeatabiity | Maximum Diference Gee 30.000 0.000 0.000 2. Correction to Balance Reading ‘Standard Indication] Unit Under Test Correction reerainty = eg ce So ia oie sy a 6.000 5.997, 0.003) 0.004 9.000 8.996 0.004 0.005 72,000 11,995 0.005 0.00% 15.000. 14,994 0.006 0.003 18.000. 17.993 0.007 0.001 21,000 70.982 0.008 0.001 24.000 23.590 0.040 0.001 27.000 26.988 0.032 0.001 30,000 23,986 0.014 0.001 3. Off Genter Loading Center Front eg SS 0.000 0.000 4, Limit of Performance 5. Hysteresis Limit of Performance 0015 kg Hysteresis 0.000 kg ‘The Uncertainty is taken at a Confidence Level 95 % For Coverage Factor (k) = 2 Calibrator used Calibrator Name ‘Manufacturer Type Serial Number ‘Traceable to SI Through 1) Mass Standard ‘CROWN FT ‘4190222 LUCOM5.I0N. 2 Mass Standard ‘CROWN, A 4180223 UCO45.10N. 3 Mass Stan EXCELLENT F2 10.10.1994 UC04510N 4 Mass Standard EXCELLENT Fo 09.10.1994 UK-045-10N Cattrated By wi Date of Issued Typist APS Mi ¢ a to qute/reproduce andlor publish par of tis cor a ‘Engineecng. This cerifeated is vaio the registered coriicate please visi, wa sert-eastemproeng Order Number 4501.24-7 Received Date December 27, 2023 Customer PT. Hutama - Adhi - Abipraya, KSO Address Jalan Poros KKT Kariangau Equipment Name: Timbangan Manufacturer cas Type Sw-11 ‘Serial Number 210469683, Capacity 30 kg Resolution 0.001 kg Calibration Report 41. Repeatability of Measurement Environment Condition of Calibration ‘Temperature (297 + 08) | Humility (88 2 28) | %RH Reference EPE.03.02.01.02.01.01 Calibration Date December 27, 2023 Calibration Location _: Leborstorium ‘Standard Indication] Repeatabllty __] Maximum Diference i 0.000 30.000 0.000 0.000 2. Correction to Balance Reading Standatd indication] Unit Under Test Treeranty = (Ce rea ‘9 3.000 7.998 0.001 0.001 6.000) 5.958 0.002 0.001 9.000 3.998 0.002 0.001 12.000. 11.997 0.003; 0.007 15.000 44.997 0.003 0.001 18.000 17.995 0.005 0.005 21,000 20.994 0.006 0.001 74.000 23,993, 0.007 0.001 77.000 26.992 0.008 0.001 30,000 23.99% 0.008 0.001 3. Off Center Loading Front tg) 0.000 4, Limit of Performance Limit of Performance 0.010 “The Uncertainty is taken at a Confisence Level 95 % For Coverage Factor (k) = 2 Manufacturer CROWN 2 Mass Standard GROWN 3. Mass Standard EXCELLENT 4 Mass Standard EXCELLENT Calibrated By wi Typist APS, 5. Hysteresis Serial Number Traceable to SI Through 4100222. LICO45.10N 4190223 LUC O4510N 10.10.1994 LCO4510N 09.10.1984 UK-045-10N ~ || PT. EASTERN PRO ENGINE! || | THEAWANI RESIDENCE Conifeate = y 0181-EPE-00- 4 ~ | Page tof t OrerNumber a5 01245 : Roceved Doe Decor, 2023 Costorer Pr Huta Adi - Abiray, KSO aa patrons Sain Pas Kir Karon Equipmert Name: Tnbangan Environment Condition of Caraton fate” CAS Target (aor 08) |" tie Swit rm rece Sore Number—_2asssn0 Hebets Pe 032010001 01 Capety ot Catraton Dato Desomber 2.2088 Revlon d001 tg Gattrabonocston Labora Calibration Report 41. Repeatability of Measurement “Standard Indication] Repeatabiity —_] Maximum Diference r 0.000. 7.000 730.000 0,000. 0.000 2. Correction to Balance Reading ‘Standard Indication] Unit Under Test Correction Uncertainty = Ya Eee ea pe tg) 398 0.002 Toor 6.000 5.994 0.006 0.001 9.000 8.991 0.009 0.001 12.000 11.588 0.012 0.001 15,000 14.585 0.015 0.001 48.000 17,582 0.018 0.008 21.000 20.975 0.024 0.001 24.000 23.575 0.025 0.008 27.000 26.571 0.029 0.008 30.000 73,964 0.036 0.008 3. Off Genter Loadi Center tg [-“c000" 0.000 4. Limit of Performance 5. Hysteresis Umit of Performance 2 007 ig Hysteresis, 0.000 kg “The Uncertainty i taken at a Confisence Level 95 % For Coverage Factor (k Calibrator used Calibrator Name Manufacturer Type Serial Number Traceable to SI Through 1 Mass Standard CROWN Ft 4190222 LK-O45:10N 2 Mass Standard CROWN fal ‘4190223, UCO4540N 3° Mass Standard EXCELLENT Fa 10.10.1994 UKO45:10N. 4 Mass Standard EXCELLENT Fo 09.10.1908 UCO4510N calrated By wu Typst aps, MY < ~ Uy

You might also like