The TP Series connectors are sealed connectors that meet high safety standards for aquatic environments. They are used in applications like vessels, diving, civil construction, and heavy industry. The connectors feature a large range of shell styles and layouts, and provide a balance of high performance and cost efficiency. They include receptacles, cable receptacles, feedthroughs, inline receptacles, and pressure sealing caps for plugs and receptacles.

Uploaded by

naim dwianansya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views40 pages

TPseries

The TP Series connectors are sealed connectors that meet high safety standards for aquatic environments. They are used in applications like vessels, diving, civil construction, and heavy industry. The connectors feature a large range of shell styles and layouts, and provide a balance of high performance and cost efficiency. They include receptacles, cable receptacles, feedthroughs, inline receptacles, and pressure sealing caps for plugs and receptacles.

Uploaded by

naim dwianansya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 40

TP Series

TP Series
Sealed Connectors
TP Series | Overview

Overview
Presentation

The TP Series connectors meet the highest standards of safety for aquatic environment. It is currently used in many
applications: vessels, civil construction, diving, heavy industry…

The TP Series feature a large range of shell styles and layouts. Derived from the widely recognized marine bronze
M Series, the TP Series are the perfect trade off between high performances and cost efficiency.

Product Details
Contents

Overview Other Series


Typical applications........................................... 6 SWIM Series...................................................... 36
Features & Benefits........................................... 7

Other Series
M Series............................................................. 36
Range overview................................................. 10 U Series............................................................. 37
8810 Series........................................................ 37
Product Details
Technical features ............................................. 14
Ordering information........................................ 16
Contacts............................................................ 18
Contact layouts ................................................. 19
Cable clamp accessories................................... 21
Shell dimensions ............................................... 22
Spare parts........................................................ 31
Tools.................................................................. 32

3
TP Series

© 2016 SOURIAU - SOURIAU is a registratred trademark


TP Series

Overview
Typical applications..................................................................................................... 6

Features & Benefits..................................................................................................... 7

Range overview........................................................................................................... 10

5
6
Vessels
Geophysics
Heavy Industry
Typical applications

© Corlaffra / Fotolia © donvictori0 / Fotolia © M. Simonia / Fotolia


TP Series | Overview

Diving

Water Treatment
© qq47182080 / Fotolia © S. Dubrov / Fotolia
Civil Construction

© O. Sved / Fotolia
TP Series | Overview

Features & Benefits

Used in Aquatic Environment


Oil and gas services: Geophysics, inspection or instrumentation
FIELD Water treatment: Pumps, valves, sewage system
PROVEN Civil construction: Tunnels, dams, buildings
Underwater instrumentation: Buoys, sensors, cameras, lights

Designed for Harsh Environment


Temporary immersion in sea water
ROBUST Prolonged immersion in freshwater and use in presence of mud, sand…
High resistance to cable pull out or transverse forces
Repairable connectors with removable inserts

Overview
High Performance Levels
Waterproof down to 300 meters depth
PERFOR- No stress on O-rings by conical coupling
MANCES Withstanding 500 mating/unmating cycles

Keying and Easy Coupling


Easy coupling/uncoupling operation even with high density layout
EASY 5-key mechanical polarization
COUPLING Scoop proof to prevent contact damage

7
TP Series | Overview

Features & Benefits

Sealed and reliable connectors

 Field proven « Harpoon » contact technology for contact to insert sealing


 O-ring for insert to shell sealing on both receptacle and plug
 Redundancy with 2 O-rings on plug taper seat
 Conical coupling interface to reduce the stress on O-rings

Panel O-ring Plug mating O-rings

Receptacle insert/shell O-ring

Plug insert/shell O-ring

High performance sealing and mechanical retention

 Perfect sealing on cable jacket is achieved with the compression of a pressure gland integrated into the plug’s backshell. Robust
cable clamp ensures the mechanical retention of the cable. A removable protective boot is added on the backshell for additional
sealing and cable support.

TP type cable clamp


set example

Cable clamp Collet clamp Sealing gland Packing block Protective boot

8
TP Series | Overview

Features & Benefits

High grade materials

 Shells are made of nickel plated brass specially designed for industry requirements regarding watertight products in harsh
environment. This material provides a good corrosion resistance in sea environment, a high electrical conductivity along with
good mechanical properties and resistance to biological fouling.

 O-rings are made from Nitrile for excellent fluid compatibility (sea water, mineral oil…) and long durability.

 Contacts are gold over nickel plated brass.

 RoHS compliant. COMPLIANT

Easy wiring and installation

Overview
 Scoop proof: No risk of damaging contacts during the coupling operation when using a female plug and a male receptacle.

 Removable insulators: To allow easy wiring and replacement in case of wiring mistakes or servicing.

 Easy mating: Easy coupling operation thanks to the screw coupling and locking even with a high number of contact

 Equipment protection: No coupling mistake thanks to the polarization key.

9
TP Series | Overview

Range

REC

Receptacles

RER

Cable Receptacles
RECSC

TER

Feedthroughs

TEC

In-Line Receptacles
PCE

Pressure Sealing Cap BEF

for Plug

10
TP Series | Overview

overview

Overview
FED Plugs

BER
Pressure Sealing Cap
for Receptacle

11
TP Series

© 2016 SOURIAU - SOURIAU is a registratred trademark


TP Series

Product Details
Technical features........................................................................................................ 14

Ordering information.................................................................................................. 16

Contacts...................................................................................................................... 18

Layouts........................................................................................................................ 19

Cable clamp accessories............................................................................................. 21

Shell dimensions.......................................................................................................... 22

Spare parts.................................................................................................................. 31

Tools............................................................................................................................ 32

13
TP Series | Product Details

Description
• Sealed connectors

• Screw coupling

• Sealing between plug and receptacles


performed by 2 O-rings

• Sealing on cable thanks to packing washer

Technical features
Mechanical Electrical
• Shell: • Voltage rating (Vrms) • Current rating and contact resistance:
Nickel plated brass
Current Contact
Shell
Contact size rating per resistance
• Insulator: SOURIAU Dielectric size
contact (A) (mΩ)
Voltage recommended Withstanding
PA6/6+MOS2 - Nylatron® (N) Category service voltage Voltage (Vrms
PTFE – Teflon® (T) (on request for reduced 20 7 ≤4
(Vrms 50 Hz) 50Hz)
water absorption and increased pressure 8TP 16 14 ≤3
withstand when unmated) 14 20 ≤ 2.5
Service 1 600 1500 10TP
14TP 12 26 ≤2
• O-rings: Service 2 1000 2300
Nitrile elastomer 20TP 6 65 ≤1
2 115 ≤ 0.6
• Contacts: • Insulation resistance:
Brass Unmated connectors : ≥ 104 MΩ Coaxial 50Ω 20 ≤ 2.5
10TP
Mated connectors : ≥ 5x103 MΩ on 500 Vcc Coaxial 75Ω 7 ≤4
• Contacts: 10TP Triaxial 50Ω
Brass with gold over nickel plated • Shielding: 7 ≤4
20TP Coaxial 50Ω
Connectors mated: Resistance
between the receptacle plate and the 10TP Triaxial 75Ω
4 ≤5
• Packing washers and Protection boot: plug’s cable braid : ≤ 10 mΩ 20TP Coaxial 75Ω
Neoprene® Elastomer Coaxial 50Ω 40 ≤ 1.5
• Endurance: 14TP Triaxial 50Ω 26 ≤2
500 mating/unmating operations Triaxial 75Ω 14 ≤3

• Shock:
Static acceleration of 120g on each axis

• Vibration:
From 1 to 5 Hz: acceleration = 0.1g
From 5 to 22 Hz: amplitude = 1mm
From 22 to 50 Hz: acceleration = 2g
Duration: 1 hour on each axis

14
TP Series | Product Details

Environmental
• Operating temperature range: • Salt spray
- 20°C to + 70°C - 10 x (24h + 24h) alternate salt spray
according to EN60068-2-11
• Watertightness - 500h continuous salt spray according to
NFC93422

Mated Unmated • Fluids Resistance


- Oil, alcohol, petrol, diesel fuel, sea water
- Various gases (natural, butane, propane,
30 bar 5 bar Freon)
- Various acids (acetic, boric, citric)

Product Details

15
TP Series | Product Details

Ordering information

Product builder
N° Criterias Choices Pages

1 Wires type and gauge Minimum contact size 18

2 Number of contact to connect Contacts layout 19

3 Electrical characteristics Layout and shell size 14

4 Cable diameters Size checking 21

5 Shell dimensions Shell type consistency 10-11

Recommendations

Watertightness of the TP Series connectors


Watertightness is achieved through the use of a packing-block and performance will depend on cable quality:
. Hardness (shore A hardness > 70 is recommended)
. Cylindricity and circularity
. Roughness
. Cable outer diameter tolerance (maximum tolerance of 1 mm on outer diameter is recommended)

16
TP Series | Product Details

TP Series connectors part numbers


PCE M 14TP N 04 16 U 095

Shell type
RER: Jam-nut receptacle
REC: Screws mounting receptacle
FED: Straight plug
PCE: In-line receptacle
RECSC: Screws mounting cable connecting receptacle
TER: Jam-nut feedthrough
TEC: Screws mounting feedthrough

Type of contacts
M: Pin contact
F: Socket contacts
1: Pin/Socket (for TEC and TER feedthroughs only)
Shell size
8TP
10TP
14TP
20TP
Insulating material
N: Nylatron® (PA6/6+MOS2)
T: Teflon® (PTFE) (Available on request)

Contact layouts
See layout tables page 19 - 20

Cable clamp code


U: Possible braid or armor termination

Maximum cable outer diameter (in tenth of mm, adjusted at upper five tenth). Example: For a 9.2mm outer diameter cable, the code is 095.
Cable code for coaxial, tri-axial, (Please consult us)

Product Details
Nothing for RER, REC, TER & TEC

Pressure sealing cap part numbers


BER C 10TP

Cap type
BER: For receptacles
BEF: For plugs

Cord set
C: With cord
-: Without cord (no mention)

Shell size
8TP
10TP
14TP
20TP

17
TP Series | Product Details

Contacts - Size 2 to 20
Ø A (mm) Ø F (mm)
Shell size Contact size Active Contact Gauge AWG Section (mm2) Definition
contact OD Termination OD

20 1,02 0,9 26 to 22 0,14 to 0,38


8TP
16 1,59 1,2 24 to 20 0,21 to 0,60 Pin

ØF
ØA
20 1,02 0,9 26 to 22 0,14 to 0,38

16 1,59 1,4 22 to 18 0,38 to 0,93

Socket
14 1,92 1,87 18 to 16 0,93 to 1,34

ØF
10TP
12 2,38 2,3 16 to 14 1,34 to 1,91
14TP

20TP
6 5 6,2 8 to 6 8,98 to 13,4

ØF
Pin

ØA

ØF
2 7 9 4 to 2 21,8 to 34,5 Socket

Contacts - Coaxial, triaxial*


Ø F (mm)
Ø A (mm)
Shell size Contact size Inside the solder Removable contact
Front of contact
bucket

Coaxial 50Ω 1,93 2,4


Pin
10TP
ØA

ØF
Coaxial 75Ω 1,02 1,5 No

Socket
14TP Coaxial 50Ω 3,98 3
ØF

10TP Triaxial 50Ω


0,9 1,2
20TP Coaxial 50Ω Pin
Yes
10TP Triaxial 50Ω
0,7 0,8
20TP Coaxial 75Ω Socket

Triaxial 50Ω 3 2,6


14TP No
Triaxial 75Ω 1,59 1,4

* Please consult us with your cable specification

18
TP Series | Product Details

Contact layouts

Size 8TP Layout caption

0416 0720 Layout ID


for part numbering

4#16 7#20 Number of contacts #Size


Service 2 Service 1 Voltage Service Rating

Size 10TP

TX75* 1C75* 0214 0314 0416 0516


TX50* 1C50*

Product Details
1TX#75 or 1TX#50 1C#75 or1C#50 2#14 3#14 4#16 5#16
Service 1 Service 1 Service 2 Service 2 Service 2 Service 1

0320 0720

3#20 7#20
Service 2 Service 1

Contact Type
20 16 14 2 12
14 20 12 16 6 14 6 2 Coax. Triax.

*Please consult us for coax and triax layouts

19
TP Series | Product Details

Contact layouts

Size 14TP

TX75* 1C50* 0106 0312 0412 0714


TX50*

1TX#75 or 1TX#50 1C#50 1#06 3#12 4#12 7#14


Service 2 Service 2 Service 2 Service 2 Service 2 Service 2

1216 1920

12#16 19#20
Service 2 Service 1

Size 20TP

4C75* 0102 0306 0406 0712 1612


4C50*

4C#50 or 4C75Ω 1#02 3#06 4#06 7#12 16#12


Service 1 Service 2 Service 2 Service 2 Service 2 Service 2

2114 2716 3216 4120

21#14 27#16 32#16 41#20


Service 1 Service 1 Service 1 Service 1

Contact Type
20 16 14 2 12
14 20 12 16 6 14 6 2 Coax. Triax.

*Please consult us for coax and triax layouts

20
TP Series | Product Details

Cable clamp kits


Cable clamp
Grounding Size
code

8TP
10TP
U YES
14TP
20TP

Acceptable cable outer diameter


Cable code Description
8TP 10TP 14TP 20TP

Standard cable clamp with braid or armor


U Ø4 to Ø6,2 Ø5 to Ø11 Ø9 to Ø16 Ø16 to Ø26
termination

CPI Collet clamp RGR Packing block

ESC Cabling spacer JPE Rubber washer

DOS Outer sleeve MDP Protective boot

Product Details

Note: All dimensions are in millimeters (mm)

21
TP Series | Product Details

Shell dimensions

RER - Jam-nut receptacle

B
Panel cut-out
N
ØM
0.1 K

0.2Max. to 45°
ØK +0.1
0
ØG
ØE
ØF

H Max.

On flats J

Shell size 8TP 10TP 14TP 20TP

A 23 37 37 49,5

B 8.5 14 13 17

Ø E (ISO) M17 x 1 M21 x 1 M29 x 1 M41 x 1

Ø F (ISO) M14 x 0.75 M18 x 0.75 M25 x 0.75 M36 x 1

ØG 20 25 34 46

H Max. 5 10 9 12

On flats J 17 22 30 41

Ø K+/-0.1 14.2 18.2 25.2 36.2

M 13.2 16.2 23.2 33.2

N 3 4 4 5

Note: All dimensions are in millimeters (mm)

22
TP Series | Product Details

Shell dimensions

REC - Square flange receptacle

A
B P

ØE
ØF

C Panel cut-out
ØQ D
D

0.2Max. to 45°
ØK +0.1
0
D
C

Product Details
0.1 K
Holes ØL
4 blind threaded holes

Shell size 8TP 10TP 14TP 20TP

A 23 37 37 49.5

B 4 14 13 17

C 23 32 40 52

D 17.5 24 31 42

Ø E (ISO) M17 x 1 M21 x 1 M29 x 1 M41 x 1

ØF 14 18 25 36

ØK +/-0.1
14.2 18.2 25.2 36.2

ØL 3.2 4.3 5.3 6.3

P 3 5 6 8

Ø Q Max. 31.5 42.5 53.5 70.5

R (ISO) M3 M4 M5 M6

Note: All dimensions are in millimeters (mm)

23
TP Series | Product Details

Shell dimensions

TER - Jam-nut feedthrough

B
Panel cut-out
N
0.1 K ØM

0.2Max. to 45°
Use Socket

ØK +0.1
Use Pin

0
plug

plug
ØG
ØE

ØE

H Max.
On flats J

Shell size 8TP 10TP 14TP 20TP

A 50 60 60 82

B 34.5 35.5 34.5 47.5

Ø E (ISO) M17 x 1 M21 x 1 M29 x 1 M41 x 1

ØG 23 28 40 52

H Max. 19 16 13 22

On flats J 20 24 34 46

Ø K+/-0.1 17.2 21.2 29.2 41.2

M 14.2 19.2 27.2 39.2

N 4 4 6 5

Note: All dimensions are in millimeters (mm)

24
TP Series | Product Details

Shell dimensions

TEC - Square flange feedthrough

A
B P
Use socket plug

Use pin plug


ØE

ØE

Panel cut-out
C
ØQ D
D
4 blind threaded holes

0.2Max. to 45°
0.1 K

ØK +0.1
0
D
C

4 holes ØL

Product Details
H Max.

Shell size 8TP 10TP 14TP 20TP

A 50 60 60 82

B 34.5 35.5 34.5 47.5

C 32 40 52 76

D 24 31 42 60

Ø E (ISO) M17 x 1 M21 x 1 M29 x 1 M41 x 1

H Max. 23 20 19 27

ØK +/-0.1
17.2 21.2 29.2 41.2

ØL 4.3 5.3 6.3 8.5

P 4 6 8 9

Ø Q Max. 42.5 53.5 70.5 100.5

R (ISO) M4 M5 M6 M8

Note: All dimensions are in millimeters (mm)

25
TP Series | Product Details

Shell dimensions

RECSC - Square flange cable connecting receptacle

G
A
B P
On flats S

ØE
ØJ1 Max ØJ Max ØF

C Panel cut-out
ØQ D D

0.2Max. to 45°
4 blind threaded holes
0.1 K

ØK +0.1
0
D
C

4 holes ØL

H Max

Shell size 8TP 10TP 14TP 20TP

A 57 82 100 126

B 42 58 76 96

C 32 40 52 76

D 24 31 42 60

ØE M17 x 1 M21 x 1 M29 x 1 M41 x 1

ØF 18 22 29 41

G 83 119 153 198

H Max. 10 12 12 20

Ø J Max. 20 23 32 45

Ø J1 Max. 17 20 27 39

ØK +/-0.1
18.2 22.2 29.2 41.2

ØL 4.3 5.3 6.3 8.5

P 4 8 8 9

Ø Q Max. 42.5 53.5 70.5 100.5

R M4 M5 M6 M8

Note: All dimensions are in millimeters (mm)

26
TP Series | Product Details

Shell dimensions

PCE - In-line receptacle

D
C

Product Details
ØE

ØA On flats J ØB Max

Shell size 8TP 10TP 14TP 20TP

ØA 19 23 31 43

Ø B Max. 20 23 32 45

C 57 82 100 126

D 83 119 153 198

Ø E (ISO) M17 x 1 M21 x 1 M29 x 1 M41 x 1

On flats J 17 20 28 38

On flats S 12 16 20 30

Note: All dimensions are in millimeters (mm)

27
TP Series | Product Details

Shell dimensions

FED - Straight plug

C On flats S

ØA On flats J ØB Max

Shell size 8TP 10TP 14TP 20TP

ØA 20 25 34 46

Ø B Max. 20 23 32 45

C 53 72 90 114

D 79 110 144 186

On flats J 17 22 30 42

On flats S 12 16 20 30

Note: All dimensions are in millimeters (mm)

28
TP Series | Product Details

Shell dimensions

Pressure sealing caps

BEF - Cap for plug BER - Cap for receptacle

A C

ØD
ØB

On flats J
On flats S

240 240

Shell size 8TP 10TP 14TP 20TP

A 30 39 40 51

ØB 20 25 34 46

C 27 34 34 48.5

Product Details
ØD 20 25 34 46

On flats J 17 20 28 38

On flats S 17,46 22 30 42

Mated/Unmated connectors

R = Mated shells overlap

Shell size 8TP 10TP 14TP 20TP

R 11 19 19 25

Note: All dimensions are in millimeters (mm)

29
TP Series | Product Details

Insert + Contacts sub assembly part numbers


Insert + Contacts Sub Assembly BIS 14TP N 04 12 M

Shell type:
8TP, 10TP, 14TP, 20TP

Insert material
N: Nylatron (PA6/6+MOS2)
T: Teflon (Available on request )

Contact layouts
See layout tables pages 19-20
Type of contacts
M: Male contacts
F: Female contacts

Cable clamp kit part numbers


Kit type: See page 21 RAE 14TP U 100
RAE: Full cable clamp kit
RAER: Cable clamp kit sub assembly

Shell size:
8TP, 10TP, 14TP, 20TP

Cable clamp
U: With braid or armor termination

Maximum cable outer diameter (in tenth of mm, adjusted at upper five tenth). Example: For a 9.2mm outer diameter cable, the code is 095.
Cable code for coaxial, tri-axial (consult us for coding)

30
TP Series | Product Details

O-ring part numbers


O-ring Type 8TP 10TP 14TP 20TP

 Panel O-ring (for REC-RER) 09-01 10-01 14-01 20-01

 Insulator/Shell O-ring 09-02 10-02 14-02 20-02

 Taper seat O-ring 09-03 10-03 14-03 20-03

 Panel O-ring (for TEC-TER) 09-04 10-04 14-04 20-04

 Panel O-ring (for RECSC) 10-01 20-02 14-05 20-04

REC-RER Receptacles FED Plug PCE Cable connecting plug

2
1 2 3 2

Product Details
TEC-TER Bulkhead BER Cap RECSC Square flange in-line receptacle

3 2 5
2 4

31
TP Series | Product Details

Tools
Plug wiring tools
These tools are used to maintain correctly plugs during the final
operation of wiring: tightening the tightening sleeve

Plug Size Tool P/N

8TP MA1W6010B5

10TP MA2W6010B5

14TP MA3W6010B5

20TP MA4W6010B5

End wrenches
Used to tighten coupling ring of size 20TP with a torque wrench

P.N : OUT 050W5031B5

20

Plastic jaw plier


This tool is used for holding the cable clamp while tightening the sleeve

P/N : 410.01

Potting tool
Used to fill with resin cabling spacers

Size Tool P/N

10TP OUT330 10M

14TP OUT330 14M

20TP OUT330 20M

The wiring and installation instruction for TP Series connectors can be provided upon request.
Note: All dimensions are in millimeters (mm)

32
TP Series | Product Details

Notes

Product Details

33
TP Series

© 2016 SOURIAU - SOURIAU is a registratred trademark


TP Series

Other Products
SWIM Series................................................................................................................ 36

M Series....................................................................................................................... 36

U Series....................................................................................................................... 37

8810 Series.................................................................................................................. 37

35
TP Series | Other Products

Other Series

SWIM Series
Shallow Water IMmersion

The cost effective and reliable solution for shallow N EW


PRODUCT
water immersion in high performance thermoplastic
construction.

High sealing performances:


. Down to 300 meters depth

Large range:
. 2 sizes: 10PL and 14PL
. Receptacles, plugs and caps
. Signal, power and coax

RoHS compliant COMPLIANT

M Series

Dry mateable connectors for deep immersion.


See specific catalog available online.

High sealing performances:


. Down to 3000 meters depth

Large range:
. 5 shell sizes
. Receptacles, cable receptacles, plugs and feedthroughs.
. Signal, power, high voltage, coax and triax contacts

Robust:
. High corrosion resistant marine bronze shells
. Robust screw coupling mechanism

RoHS compliant COMPLIANT

36
TP Series | Other Products

Other Series

U Series

Connectors similar to M Series with 316L


stainless steel shells and FPM seals.
See specific catalog.

High pressure withstand:


. Down to 300 meters depth

Robust:
. High corrosion resistant stainless steel shell (AISI 316L)
. Robust screw coupling mechanism
. High temperature resistance (up to 170°C with PTFE insulators)
. Nylatron, Teflon or Tefzel insulators
. Radiation withstanding (up to 100 MRads)

RoHS compliant COMPLIANT

8810 Series

Wet/underwater mateable connectors for deep


immersion. See specific catalog available online.

Other Series
High pressure withstand:
. Down to 3000 meters depth

Robust:
. Marine bronze shells
. Robust screw coupling mechanism

RoHS compliant COMPLIANT

37
TP Series | Other Products

Notes

38
Reliable People, Reliable Solutions

All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.
Your local contact

Our contribution to environmental


protection:
This catalog is printed on PEFC
certified paper
Advancement of sustainable
10-31-1299 wood cultivation. www.pefc.org
Promoting sustainable
forest management

www.pefc.org

WCATPWUSEN01 © Copyright SOURIAU Spet 2017 - SOURIAU is a registered trademark

www. esterline-connection-technologies.com
[email protected] (Europe - Asia - Africa)
[email protected] (Americas)

You might also like