R
ASSEMBLY INSTRUCTION
NE8MC6 | etherCON Cable Connector CAT 6
A A Slide the boot onto the cable.
B Terminate RJ45 connector on the cable.
See following pages.
Press the locking latch of the RJ45 and place the
C two adapters onto the RJ45.
B Pay attention: Hold the brackets together.
Put chuck onto the cable.
D Attention: Pay attention to the guiding key.
C Slide RJ45 and chuck together into the housing.
E Pay attention to the plug latch which has to be on the
opposite side of the key.
Finish the assembly by turning the bushing onto the
F connector. Screw bushing fully up to the end.
E Key
Suitable cables:
AWG 22 to 28 soldid or stranded conductors with an
insulation. O.D. 0.037” / 0.95 mm to 0.047” / 1.07 mm.
Jacket: O.D. 0.22” / 5.5 mm to 0.25” / 6.5 mm
NEUTRIK AG LI T: +423 / 237 24 24 F: +423 / 232 53 93 NEUTRIK Vertriebs GmbH DE / NL / AT T: +49 8131 / 280 890 F: +49 8131 / 280 830
NEUTRIK Zürich AG CH T: +41 44 / 736 5010 F: +41 44 / 736 5011 NEUTRIK France FR T: +33 1 / 4131 6750 F: +33 1 / 4131 0511
NEUTRIK USA Inc. USA T: +1 732 / 901 9488 F: +1 732 / 901 9608 NEUTRIK Tokyo Ltd. JP T: +81 3 / 3663 4733 F: +81 3 / 3663 4796
NEUTRIK (UK) Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439 NEUTRIK Hong Kong Ltd. HK T: +852 / 2687 6055 F: +852 / 2687 6052
Draft. Nr.: BDA 194 / 3102M1581 I Update: 20.05.2010 I Data subject to change without prior notice. ©2010 NEUTRIK® . ALL RIGHTS RESERVED.
www.neutrik.com
R
ASSEMBLY INSTRUCTION I etherCON CAT 6
B Terminate RJ45 connector on the cable.
1 White-Green
2 Green Consider cable end termination usually straight - thru
3 White-Orange
4
5
Blue
White-Blue
cable acc. TIA 568A.
6 Orange
7 White-Brown
8 Brown
1 Assembly of wire, load bar and plug.
2
Strip outer jacket 20 mm long.
3 Separate pairs in bundles.
4 Straighten and separate into individual leads.
5 Organize leads into proper order and trim edge to be
even.
6 Wire lead ends shown organized and trimmed.
BDA 194 I 20.05.2010 -2-
R
ASSEMBLY INSTRUCTION I etherCON CAT 6
7 Insert Load Bar and load Wires into open end.
8 Slide Load Bar into position against Jacket.
9
Trim leads so Jacket is 8.64 mm / 0.34” from edge.
8.64 mm
[0.34”]
10 Inser Wires and Load Bar into Plug and push ful forward.
Terminate Plug with Hand Terminator MOLEX #62202-
0500 or any other suitable crimp tool.
11
In the case of using shielded cable crimp shield to
connector.
BDA 194 I 20.05.2010 -3-