TECKA Air Cooled Screw Chiller (Heat Pump) Unit - Brochure TECKA202103
TECKA Air Cooled Screw Chiller (Heat Pump) Unit - Brochure TECKA202103
RSA-100~480 R134a
technical standards, and setting more and more milestones. + Steam compression cycle water chiller unit for nuclear power plant
+ Integrated air conditioner package
+ Water source heat pump package
With the development of the construction of an energy saving soci- + Building technical norms for hospital clean surgery department
+ Evaluation standard for renewable energy building application construction
ety, TECKA cold and heat source systems continue to contribute + Ventilation and air conditioning engineering construction norms
value to customers, society and nature. The application of prod- + Air conditioner variable capacity terminal device
+ Design norms of civil buildings HVAC system
ucts and technologies such as air-cooled screw chiller, intelligent ······
energy station, intelligent control, natural cold using chiller, etc.,
enables TECKA to provide smarter and more energy saving solu-
tions with more value shared. 1993
TECKA launched the semi-closed double screw air cooled
heat pump unit, creating a precedent in the field of screw
chiller in the central air-conditioning industry in China.
01 02
Air Cooled Screw Chiller (Heat Pump) Unit
RSA air-cooled screw water chiller (heat pump) unit combines TECKA’s innovative ideas and decades
of air-cooled screw compressor R&D and application experience, and integrates a number of advanced
designs and patented technologies: modular design, high-performance double screw compressor,
Third-generation cyclone-type high-efficiency oil separation technology, E2C high-efficiency heat
exchange tube technology, intelligent on-demand defrosting and asynchronous defrosting technology,
evaporator distribution technology, anti-electromagnetic interference type electric box, intelligent control
technology, etc. With the features of excellent performance, energy saving and reliable.
100%
● The rotor adopts a profile design optimized for the compression process. The new rotor profile ensures that the compressor has capacity of the unit and the user demand load, accurate supply,
a higher speed and a better volumetric efficiency and a low limit of leakage. and ensure that the unit can operate efficiently under full load 75%
● The high-efficiency motor improve the power factor. Adopts a two-in-one optimized motor internal air flow channel design, the 25%
refrigerant surrounds the motor stator to achieve the best heat dissipation effect. It ensures better cooling of the motor, at the same
time, the pressure drop loss of the refrigerant is minimized. 25% 50% 75% 100% Capacity demand
100
High applicability
50
● The design of the high-efficiency air-side heat exchanger 45℃
increases the heat transfer area and reduces the heat transfer
temperature difference, so that the unit can be suitable for
50 50 100 150 200 250 cooling under high temperature conditions of 45℃ in summer
and heating under low temperature conditions of -15℃ in winter.
50 -15℃
100
Easy to install
● The screw rotor is directly driven, with few moving parts and high
mechanical efficiency. ● The standard modular unit is small and light, which is especially
suitable for lifting in tall buildings.
● The new air-side heat exchanger has undergone professional airflow ● The unit does not need to be specially equipped with cooling
field simulation calculations to ensure the uniform air of the inner and towers and dry coolers, saving space and materials.
outer heat exchangers, reduce the lower air side resistance, increase the ● Integrated design for electrical components and host, no need
heat exchange area, and improve the heat exchange capacity. additional electric control box.
03 04
Air Cooled Screw Chiller (Heat Pump)
Features
Low noise & Low vibration Advanced control
● The compressor shell adopts double-layer and special dynamic balance design, which effectively reduce the compressor
Equipped with TECKA intelligent control system, with functions of independent analysis, self-diagnosis, automatic protection, remote
noise.
control, automatic forewarning.
● Interface
+ Timer start-stop, fully automatic unattended operating.
Vacuum chamber
+ Friendly interface, easy to operate.
Double-layer shell + Mode control, parameter design, user parameter setting, historical alarm.
Inner shell + Operating conditions and status check (unit status, inlet and outlet water temperature, system status, suction and exhaust pressure,
suction and exhaust temperature and overheat, electronic expansion valve opening, ambient temperature).
Outer shell
+ Multi-level password to prevent misoperation.
● The α-type balance drum adopts the elastic damping principle to balance the rotor's
fine vibration to avoid rigid impact, reduce wear, and vibration noise.
● The fan impeller is optimized by professional flow field software to ensure that the
impeller has good aerodynamic performance, and ensures that the fan operates with
high static pressure and low noise under the maximum air capacity working condition.
● Protections
99.9%
Detour oil separation
technology
95
Power undervoltage Evaporator
Motor overheat Power
Phase loss and sequence Anti-freezing
Linear oil separation High exhaust
95%
technology
90 temperature
System high pressure Controller failure, sensor pressure
Compressor Compressor oil Pressure
90% pressure differential System low pressure and temperature failure
85 Compressor
overload Fan Fan overload Water flow
05
05
04
06
Air Cooled Screw Chiller (Heat Pump)
Model name
Ambient temperature(℃)
Ambient temperature(℃)
② Model: 45 20
③ Compressor number:
15
④ Refrigerant: A = R134a 40
⑤ Evaporator: D = Dry shell-tube type F = Flooded type
10
⑥ Outlet water temperature: 0 = 12~21℃ 1 = 4~12℃ 2 = -6~5℃ 5 = 5~50℃ 6 = 5~60℃ 7 = Other
35
⑦-⑧ Function: C0 = Cooling-only C1 = Year-round cooling C2 = Natural cold use open type 5
C3 = Natural cold use close type H0 = Heat pump H1 = Heating-only
30
H2 = Low ambient temperature heat pump type H3 = Low ambient temperature heating-only type 0
25 -5
20 -10
Capacity 0 5 10 15 20
Outlet water temperature(℃)
25 20 30 40 50 60
Outlet water temperature(℃)
70
TECKA Air Cooled Screw Chiller adopts a continuous capacity adjustment method to achieve precise control of the chiller unit capacity and
achieve optimal operating energy efficiency.
The capacity adjustment range of the chiller is shown in the following table:
2
25%
12.50%
25%~100%
12.50%~100%
Electrical data
R22 R134a
Max. operating Max. operating
Model Nominal operating current (A) Nominal operating current (A)
current (A) current (A)
Cooling Heating Cooling Heating
Operating
RSA-100-1 - - - 195 194 239
RSA-120-1 - - - 213 211 265
RSA-135-1A - - - 251 249 307
RSA-150-1 - - - 305 302 370
RSA-180-1 - - - 338 335 417
Cooling condition Heating condition
RSA-200-1 - - - 396 392 482
Refrigerant R134a R134a RSA-220-1 - - - 425 422 523
Shell tube heat exchanger (Evaporator) Lowest temp. ℃ Highest temp. ℃ Lowest temp. ℃ Highest temp. ℃ RSA-240-1B - - - - - -
RSA-220-2B - - - - - -
Outlet water temp. ℃ 5 20 35 60
RSA-240-2 - - - 428 424 529
Shell tube heat exchanger (Evaporator) Min. temp. difference ℃ Max. temp. difference ℃ Min. temp. difference ℃ Max. temp. difference ℃ RSA-270-2 - - - 507 503 614
RSA-300-2 - - - 561 556 677
Water inlet/outlet temp. difference ℃ 4 8 4 8
RSA-320-2A - - - 615 609 739
Fin heat exchanger (condenser) Lowest temp. ℃ Highest temp.℃ Lowest temp. ℃ Highest temp. ℃ RSA-340-2 - - - 648 642 786
Ambient temp. ℃ 21 45 -7 21 RSA-370-2 - - - 681 675 833
Note
1. The diameter of the N and ground wire is generally two times smaller than the 4. The chiller configures the cable according to the maximum operating current.
Note: The lowest ambient temperature of the year-round cooling unit is not limited by temperature. power wire (or refer to the general five-core cable standard). 5. The maximum operating current refers to the maximum operating current
2. The wire is selected according to the ambient temperature of 35℃. during cooling or heating within the operating range.
3. Each power inlet should use a special PVC pipe for wiring, and cannot share 6. The power supply voltage fluctuation range is ±10%.
07 08
Air Cooled Screw Chiller (Heat Pump) Unit
Parameters-R134a
Air-cooled screw type-R134a RSA 100-1A 120-1A 135-1A 150-1A 180-1A 200-1A 220-1A 240-2A Air-cooled screw type-R134a
风冷螺杆-R134a RSA 270-2A
240-2A 300-2A 320-2A 300-2A
270-2A 340-2A 370-2A
320-2A 400-2A 440-2A 370-2A
340-2A 480-4A
Nominal cooling capacity kW 372 413 471 555 645 731 797 826 Nominal cooling capacity kW 942 1026 1110 1200 1290 1462 1594 1652
Nominal heating capacity kW 374 413 472 557 646 731 803 826 Nominal heating capacity kW 944 1029 1114 1203 1292 1462 1606 1652
Cooling kW 109.3 120.1 137.8 162.1 184.8 214.0 230.1 240.2 Cooling kW 275.6 299.9 324.2 346.9 369.6 428.0 460.2 480.4
Input power Input power
Heating kW 107.6 118.3 136.1 161.1 183.4 213.1 230.3 236.6 Heating kW 272.2 297.2 322.2 344.5 366.8 426.2 460.6 473.2
Maximum operating current A 239 265 307 370 417 482 523 529 Maximum operating current A 614 677 739 786 833 482×2 523×2 529×2
Power supply / 380V/3Ph/50Hz (Please specify when ordering special voltage) Power supply / 380V/3Ph/50Hz (Please specify when ordering special voltage)
Control Method / PLC programmable controller intelligent control with touch screen Control Method / PLC programmable controller intelligent control with touch screen
Type / Semi-closed screw compressor/VFD type Type / Semi-closed screw compressor/VFD type
Compressor Compressor
Number / 1 1 1 1 1 1 1 2 Number / 2 2 2 2 2 2 2 4
Heat exchanger type / High-efficiency copper tube string hydrophilic aluminum corrugated fin Heat exchanger type / High-efficiency copper tube string hydrophilic aluminum corrugated fin
Fan type / Low noise axial fan (Optional VFD fan and EC fan) Fan type / Low noise axial fan (Optional VFD fan and EC fan)
Air side Air side
heat exchanger Fan qty. / 6 6 8 10 10 12 12 12 heat exchanger Fan qty. / 16 18 20 20 20 24 24 24
Input power kW 10.8 10.8 14.4 18.0 18.0 21.6 21.6 21.6 Input power kW 28.8 32.4 36.0 36.0 36.0 43.2 43.2 43.2
Flooded type heat exchanger with the pressure of 1.0MPa Flooded type heat exchanger with the pressure of 1.0MPa
Heat exchanger type / (please specify when ordering special pressure) Heat exchanger type / (please specify when ordering special pressure)
Water flow m 3/h 64.0 71.0 81.0 95.5 110.9 125.7 137.1 142.1 Water flow m 3/h 162.0 176.5 190.9 206.4 221.9 251.5 274.2 284.1
Water side Water side
heat exchanger Inlet/Outlet heat exchanger Inlet/Outlet
pipe diameter DN 125 125 125 125 150 150 150 200 pipe diameter DN 200 200 200 200 200 150×2 150×2 200×2
Cooling capacity kW 383 425 485 572 664 753 821 851 Cooling capacity kW 970 1057 1143 1236 1329 1506 1642 1702
Machine input power kW 106.0 116.5 133.7 157.2 179.3 207.6 223.2 233.0 Machine input power kW 267.3 290.9 314.5 336.5 358.5 415.2 446.4 466.0
Heat recovery kW 93 103 118 139 161 183 199 207 Heat recovery kW 236 257 278 300 323 366 399 413
Chilled water Chilled water
Partial heat flow m 3/h 65.9 73.2 83.4 98.3 114.3 129.5 141.2 146.3 Partial heat capacity m 3/h 166.9 181.8 196.6 212.6 228.5 259.0 282.4 292.7
recovery parameter Chilled water recovery parameter Chilled water
pressure drop kPa 48 51 53 54 56 55 54 52 pressure drop kPa 55 56 54 55 57 57 56 54
Hot water flow m 3/h 16.0 17.8 20.3 23.9 27.7 31.4 34.3 35.5 Hot water flow m 3/h 40.5 44.1 47.7 51.6 55.5 62.9 68.5 71.0
Hot water Hot water
pressure drop kPa 11 13 14 14 15 14 15 13 pressure drop kPa 15 16 16 17 17 14 15 13
L mm 3575 3575 4700 5825 5825 6950 6950 6950 L mm 9200 10325 11450 11450 11450 13900 13900 13900
Dimensions W mm 2250 2250 2250 2250 2250 2250 2250 2250 Dimensions W mm 2250 2250 2250 2250 2250 2250 2250 2250
H mm 2500 2500 2500 2500 2500 2500 2500 2540 H mm 2540 2540 2540 2540 2540 2500 2500 2540
Shipping weight kg 4500 4650 5550 6580 6800 7760 8070 8900 Shipping weight kg 10700 11730 12760 12980 13200 7760×2 8070×2 8900×2
Weight Weight
Operating weight kg 4590 4750 5700 6800 7100 8080 8420 9250 Operating weight kg 11070 12130 13200 13500 13800 8080×2 8420×2 9250×2
Note: Note:
1. Nominal cooling conditions: the chilled water outlet temperature is 7℃, the water flow is 0.172m3/(h.kW), and the outdoor ambient 1. Nominal cooling conditions: the chilled water outlet temperature is 7℃, the water flow is 0.172m3/(h.kW), and the outdoor ambient
temperature is 35℃. temperature is 35℃.
2. Nominal heating conditions: the hot water outlet temperature is 45℃, the water flow is 0.172m3/(h.kW), the outdoor dry bulb temperature 2. Nominal heating conditions: the hot water outlet temperature is 45℃, the water flow is 0.172m3/(h.kW), the outdoor dry bulb temperature
is 7℃, and the wet bulb temperature is 6℃. is 7℃, and the wet bulb temperature is 6℃.
3. Design working conditions of partial heat recovery units: hot water inlet and outlet temperature is 45℃, chilled water inlet and outlet 3. Design working conditions of partial heat recovery units: hot water inlet and outlet temperature is 45℃, chilled water inlet and outlet
temperature is 7℃, outdoor ambient temperature is 35℃. temperature is 7℃, outdoor ambient temperature is 35℃.
09 10
Air Cooled Screw Chiller (Heat Pump)
Correction coefficient-R134a
Correction coefficient table of cooling capacity (Off-design cooling condition) Correction coefficient table of heatling capacity (Off-design heating condition)
Ambient Outlet temperature (℃) Dry bulb Outlet temperature (℃)
temperature (℃) 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 temperature (℃) 35 36 37 38 39 40 41 42 43 44 45 46 47
21 1.025 1.057 1.090 1.123 1.158 1.193 1.229 1.265 1.302 1.339 1.378 1.416 1.456 1.492 1.532 1.575 -7 0.642 0.641 0.640 0.639 0.638 0.637 0.636 0.635 0.634 0.633 0.632 0.630 0.629
-6 0.665 0.664 0.663 0.662 0.661 0.660 0.659 0.658 0.657 0.655 0.654 0.653 0.651
22 1.021 1.053 1.085 1.118 1.153 1.187 1.223 1.259 1.296 1.333 1.372 1.409 1.449 1.485 1.525 1.567
-5 0.689 0.688 0.687 0.686 0.685 0.683 0.682 0.681 0.680 0.678 0.677 0.676 0.674
23 1.016 1.048 1.080 1.113 1.147 1.182 1.218 1.253 1.290 1.327 1.365 1.403 1.442 1.478 1.518 1.560
-4 0.713 0.712 0.711 0.710 0.709 0.707 0.706 0.705 0.703 0.702 0.701 0.699 0.698
24 1.011 1.043 1.075 1.108 1.142 1.176 1.212 1.247 1.283 1.320 1.358 1.395 1.434 1.471 1.511 1.552 -3 0.738 0.737 0.736 0.735 0.733 0.732 0.731 0.729 0.728 0.726 0.725 0.723 0.722
25 1.006 1.038 1.069 1.102 1.136 1.170 1.206 1.241 1.277 1.313 1.351 1.388 1.426 1.464 1.503 1.544 -2 0.764 0.762 0.761 0.760 0.758 0.757 0.756 0.754 0.753 0.751 0.749 0.748 0.746
26 1.001 1.032 1.063 1.096 1.130 1.164 1.199 1.234 1.270 1.306 1.343 1.380 1.418 1.456 1.495 1.536 -1 0.790 0.789 0.787 0.786 0.784 0.783 0.781 0.780 0.778 0.777 0.775 0.773 0.771
27 0.995 1.026 1.057 1.090 1.123 1.157 1.192 1.227 1.262 1.298 1.335 1.372 1.410 1.448 1.487 1.527 0 0.817 0.815 0.814 0.812 0.811 0.809 0.808 0.806 0.804 0.803 0.801 0.799 0.797
28 0.989 1.020 1.051 1.083 1.116 1.150 1.185 1.220 1.255 1.291 1.327 1.364 1.402 1.439 1.478 1.518 1 0.844 0.843 0.841 0.840 0.838 0.836 0.835 0.833 0.831 0.829 0.827 0.825 0.823
2 0.872 0.871 0.869 0.867 0.866 0.864 0.862 0.860 0.858 0.857 0.855 0.852 0.850
29 0.983 1.014 1.045 1.077 1.110 1.143 1.178 1.212 1.247 1.283 1.319 1.355 1.393 1.430 1.469 1.509
3 0.901 0.899 0.898 0.896 0.894 0.892 0.890 0.888 0.886 0.884 0.882 0.880 0.878
30 0.977 1.007 1.038 1.070 1.102 1.136 1.170 1.204 1.239 1.274 1.310 1.347 1.384 1.421 1.460 1.499
4 0.931 0.929 0.927 0.925 0.923 0.921 0.919 0.917 0.915 0.913 0.911 0.908 0.906
31 0.970 1.000 1.031 1.062 1.095 1.128 1.162 1.196 1.230 1.265 1.301 1.337 1.374 1.412 1.450 1.489 5 0.961 0.959 0.957 0.955 0.953 0.951 0.949 0.947 0.944 0.942 0.940 0.937 0.935
32 0.963 0.993 1.023 1.055 1.087 1.120 1.154 1.188 1.222 1.256 1.292 1.328 1.364 1.402 1.440 1.479 6 0.992 0.990 0.988 0.986 0.984 0.981 0.979 0.977 0.974 0.972 0.970 0.967 0.964
33 0.956 0.986 1.016 1.047 1.079 1.112 1.146 1.179 1.213 1.247 1.283 1.318 1.354 1.392 1.429 1.468 7 1.023 1.021 1.019 1.017 1.015 1.012 1.010 1.008 1.005 1.003 1.000 0.997 0.995
34 0.949 0.978 1.008 1.039 1.071 1.103 1.137 1.170 1.204 1.238 1.273 1.308 1.344 1.382 1.419 1.457 8 1.056 1.053 1.051 1.049 1.047 1.044 1.042 1.039 1.036 1.034 1.031 1.028 1.025
9 1.089 1.086 1.084 1.082 1.079 1.077 1.074 1.071 1.069 1.066 1.063 1.060 1.057
35 0.941 0.970 1.000 1.031 1.062 1.094 1.128 1.161 1.194 1.228 1.263 1.298 1.333 1.371 1.408 1.446
10 1.122 1.120 1.117 1.115 1.112 1.110 1.107 1.104 1.101 1.098 1.095 1.092 1.089
36 0.934 0.962 0.991 1.022 1.053 1.085 1.119 1.151 1.184 1.218 1.253 1.287 1.323 1.360 1.396 1.434
11 1.157 1.154 1.152 1.149 1.146 1.144 1.141 1.138 1.135 1.132 1.128 1.125 1.122
37 0.925 0.954 0.983 1.013 1.044 1.076 1.109 1.141 1.174 1.207 1.242 1.276 1.311 1.348 1.385 1.423
12 1.192 1.189 1.187 1.184 1.181 1.178 1.175 1.172 1.169 1.166 1.162 1.159 1.155
38 0.917 0.945 0.974 1.004 1.035 1.066 1.099 1.131 1.164 1.196 1.231 1.265 1.300 1.337 1.373 1.410 13 1.228 1.225 1.223 1.220 1.217 1.213 1.210 1.207 1.204 1.200 1.197 1.193 1.189
39 0.909 0.936 0.965 0.995 1.025 1.056 1.089 1.121 1.153 1.185 1.220 1.254 1.288 1.325 1.360 1.398 14 1.265 1.262 1.259 1.256 1.253 1.249 1.246 1.243 1.239 1.236 1.232 1.228 1.224
40 0.900 0.927 0.955 0.985 1.016 1.046 1.079 1.110 1.142 1.174 1.209 1.242 1.276 1.312 1.348 1.385 15 1.303 1.300 1.296 1.293 1.290 1.286 1.283 1.279 1.276 1.272 1.268 1.264 1.260
41 0.891 0.918 0.946 0.975 1.005 1.035 1.068 1.099 1.131 1.163 1.197 1.230 1.264 1.300 1.335 1.372 16 1.341 1.338 1.334 1.331 1.327 1.324 1.320 1.316 1.313 1.309 1.305 1.300 1.296
17 1.380 1.377 1.373 1.370 1.366 1.362 1.358 1.354 1.350 1.346 1.342 1.338 1.333
42 0.881 0.909 0.936 0.965 0.995 1.025 1.057 1.088 1.120 1.151 1.185 1.218 1.251 1.287 1.321 1.358
18 1.420 1.417 1.413 1.409 1.405 1.401 1.397 1.393 1.389 1.385 1.380 1.376 1.371
43 0.872 0.899 0.926 0.954 0.984 1.014 1.046 1.076 1.108 1.138 1.173 1.205 1.238 1.274 1.308 1.344
19 1.461 1.457 1.453 1.449 1.445 1.441 1.437 1.433 1.428 1.424 1.419 1.414 1.409
44 0.862 0.889 0.915 0.944 0.973 1.002 1.034 1.064 1.096 1.126 1.160 1.192 1.225 1.260 1.294 1.330 20 1.503 1.499 1.495 1.491 1.486 1.482 1.478 1.473 1.468 1.464 1.459 1.454 1.449
45 0.852 0.878 0.905 0.933 0.962 0.991 1.022 1.052 1.084 1.113 1.147 1.179 1.212 1.246 1.280 1.316 21 1.545 1.541 1.537 1.532 1.528 1.523 1.519 1.514 1.509 1.504 1.499 1.494 1.489
41 16 1.292 1.287 1.283 1.278 1.274 1.269 1.264 1.259 1.254 1.249 1.243 1.238 1.232
1.146 1.159 1.174 1.190 1.204 1.219 1.234 1.249 1.265 1.280 1.293 1.310 1.324 1.336 1.350 0.950
17 1.329 1.324 1.319 1.315 1.310 1.305 1.299 1.294 1.289 1.283 1.278 1.272 1.266
42 1.177 1.190 1.207 1.222 1.237 1.252 1.267 1.284 1.300 1.315 1.329 1.346 1.361 1.375 1.389 0.953
18 1.366 1.361 1.356 1.351 1.346 1.341 1.336 1.330 1.325 1.319 1.313 1.307 1.301
43 1.210 1.222 1.240 1.256 1.271 1.287 1.301 1.319 1.336 1.351 1.366 1.383 1.399 1.415 1.430 0.955
19 1.405 1.399 1.394 1.389 1.384 1.378 1.372 1.367 1.361 1.355 1.349 1.343 1.336
44 1.243 1.256 1.274 1.290 1.305 1.322 1.336 1.355 1.372 1.388 1.404 1.422 1.438 1.456 1.472 0.958 20 1.443 1.438 1.433 1.427 1.422 1.416 1.410 1.404 1.398 1.392 1.385 1.379 1.372
45 1.278 1.290 1.309 1.326 1.341 1.358 1.372 1.392 1.410 1.426 1.443 1.461 1.478 1.499 1.515 0.961 21 1.483 1.478 1.472 1.466 1.460 1.454 1.448 1.442 1.436 1.429 1.422 1.416 1.409
11 12
Air Cooled Screw Chiller (Heat Pump)
Dimensions drawing
Dry bulb Outlet temperature (℃)
temperature (℃) 48 49 50 51 52 53 54 55 56 57 58 59 60
-7 0.741 - - - - - - - - - - - -
-6 0.762 0.771 - - - - - - - - - - -
-5 0.782 0.792 0.801 - - - - - - - - - -
-4 0.803 0.813 0.823 0.832 - - - - - - - - - ● Chiller R134a
-3 0.824 0.834 0.844 0.854 0.864 - - - - - - - -
-2 0.845 0.855 0.866 0.876 0.887 0.897 - - - - - - -
-1 0.866 0.877 0.888 0.899 0.910 0.920 0.931 - - - - - -
0 0.888 0.899 0.910 0.922 0.933 0.944 0.955 0.966 - - - - -
1 0.909 0.921 0.933 0.944 0.956 0.967 0.979 0.990 1.001 - - - -
2 0.931 0.943 0.956 0.968 0.979 0.991 1.003 1.015 1.026 1.038 - - -
3 0.953 0.966 0.978 0.991 1.003 1.015 1.027 1.040 1.051 1.063 1.075 - -
4 0.976 0.989 1.002 1.014 1.027 1.040 1.052 1.065 1.077 1.089 1.101 1.113 -
H
5 0.998 1.012 1.025 1.038 1.051 1.064 1.077 1.090 1.103 1.115 1.128 1.140 1.153
6 1.021 1.035 1.048 1.062 1.076 1.089 1.102 1.116 1.129 1.142 1.155 1.168 1.180
7 1.043 1.058 1.072 1.086 1.100 1.114 1.128 1.141 1.155 1.168 1.182 1.195 1.208
8 1.066 1.081 1.096 1.110 1.125 1.139 1.153 1.167 1.181 1.195 1.209 1.223 1.236
9 1.089 1.105 1.120 1.135 1.150 1.164 1.179 1.194 1.208 1.222 1.237 1.251 1.265
Control box
10 1.113 1.128 1.144 1.159 1.175 1.190 1.205 1.220 1.235 1.250 1.264 1.279 1.293
W L Water inlet Water inlet
11 1.136 1.152 1.168 1.184 1.200 1.216 1.231 1.247 1.262 1.277 1.292 1.307 1.322
12 1.159 1.176 1.192 1.209 1.225 1.241 1.257 1.273 1.289 1.305 1.320 1.336 1.351
13 1.183 1.200 1.217 1.234 1.251 1.267 1.284 1.300 1.317 1.333 1.349 1.365 1.381
R134a
14 1.206 1.224 1.241 1.259 1.276 1.293 1.310 1.327 1.344 1.361 1.377 1.394 1.410
Model
15 1.230 1.248 1.266 1.284 1.302 1.320 1.337 1.355 1.372 1.389 1.406 1.423 1.440
100-1 120-1 135-1 150-1 180-1 200-1 220-1 240-2 270-2 300-2 320-2 340-2 370-2 400-2 440-2 480-4
16 1.253 1.272 1.291 1.309 1.328 1.346 1.364 1.382 1.400 1.417 1.435 1.452 1.470
17 1.277 1.296 1.316 1.335 1.354 1.372 1.391 1.409 1.428 1.446 1.464 1.482 1.500 L 3575 3575 4700 5825 5825 6950 6950 6950 9200 10325 11450 11450 11450 13900 13900 13900
18 1.301 1.321 1.340 1.360 1.379 1.399 1.418 1.437 1.456 1.475 1.493 1.512 1.530
19 1.324 1.345 1.365 1.385 1.405 1.425 1.445 1.465 1.484 1.503 1.523 1.541 1.560 Dimensions W 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250
20 1.348 1.369 1.390 1.411 1.432 1.452 1.472 1.492 1.512 1.532 1.552 1.571 1.591 mm
21 1.372 1.394 1.415 1.436 1.458 1.479 1.500 1.520 1.541 1.561 1.582 1.602 1.622 H 2500 2500 2500 2500 2500 2500 2500 2540 2540 2540 2540 2540 2540 2500 2500 2540
13 14
Air Cooled Screw Chiller (Heat Pump)
W100 D60
A A
A A
Drainage channels
W100 D60
A B C D E F G H I J K L M
Sectional view of anchor bolts
Nut gasket
Machine base
Sectional view of anchor bolts A-A Spring shock absorber
Poured concrete again after
Nut gasket the machine is positioned
Machine base
Roof
A-A Spring shock absorber Anchor bolt
Ground Poured concrete again after
the machine is positioned
The concrete strength is
Anchor bolt not lower than C15
R134a
Model
Note 100-1 120-1 135-1 150-1 180-1 200-1 220-1 240-2 270-2 300-2 320-2 340-2 370-2 400-2 440-2 480-4
1. The base must be fixed on a solid foundation, and it must be able to withstand the weight of the machine during A 1430 1430 1330 1280 1280 1250 1250 1250 1415 1375 1340 1340 1340 1250 1250 1250
operation. B 1430 1430 1330 1280 1280 1250 1250 1250 1415 1375 1340 1340 1340 1250 1250 1250
2. The machine base installation hole diameter is φ18, and the bolts should be prepared by the user. C - - 1330 1280 1280 1250 1250 1250 1415 1375 1340 1340 1340 1250 1250 1250
D - - - 1280 1280 1250 1250 1250 1415 1375 1340 1340 1340 1250 1250 1250
3. The foundation bolt anchor pit should be reserved when making the foundation. The concrete will be poured again
E - - - - - 1250 1250 1250 1415 1375 1340 1340 1340 1250 1250 1250
after the machine is positioned.
Anchor bolt F - - - - - - - - 1415 1375 1340 1340 1340 720 720 720
4. The level difference of the base plane is ≤5mm. fixing and G - - - - - - - - - 1375 1340 1340 1340 1250 1250 1250
5. The above foundation drawing is for reference, the specific installation method is determined by the working site. positioning H - - - - - - - - - - 1340 1340 1340 1250 1250 1250
(mm)
I - - - - - - - - - - - - - 1250 1250 1250
J - - - - - - - - - - - - - 1250 1250 1250
K - - - - - - - - - - - - - 1250 1250 1250
L - - - - - - - - - - - - - - - -
M - - - - - - - - - - - - - - - -
15 16
Air Cooled Screw Chiller (Heat Pump)
Lifting diagram
Lifting rope
1. TECKA Air Cooled Screw Chiller (Heat Pump) Unit could be installed on any convenient place such as roof, balcony,
ground, etc. Do not install the unit in a place where fallen leaves, insects, oily smoke or other contaminants are easy to gather
to prevent blocking the air-side heat exchanger. There should be no flammable or explosive materials near the unit.
2. The chiller unit should be installed on a well concrete foundation or a channel steel structure, the foundation should be
able to bear the weight of the chiller unit during operation. And there should be drainage ditches around the foundation.
Chiller unit installation should comply with relevant regulations.
3. To keep the equipment run quietly and avoid affecting the building, damping measures should be taken between the chiller
unit base and the foundation.
4. Obstruction is not allowed in the chiller air outlet at least 3 meters to avoid the poor air return and affect the chiller unit
performance. The above requirements should be followed when install the canopy.
5. The chilled water pump should be installed on the water inlet pipe of the unit. To ensure the water quality, a water filter of
60 mesh/inch2 must be installed on the water inlet pipe.
6. Soft connection is recommended to avoid transmitting the chiller unit vibration when the chiller unit inlet and outlet pipes
are connected to the system pipeline. The system pipeline should be effectively supported to avoid the weight of the external
pipeline damage the internal pipeline of the chiller.
7. The system pipelines should be installed with anti-shock soft joints, water filters, electronic descaling instruments, check
valves, flow meters, exhaust valves, stop valves and other components according to the regulations. The temperature gauge
Lifting lugs and pressure gauge should be installed on the pipeline to observed the chiller and the air conditioning system better.
8. All the pipelines should be tested strictly for leaking before working to ensure the safety of operation. All the pipelines
should be strictly insulated and waterproofed.
9. The pipeline in the chiller should be cleaned and the impurities in the pipeline should be removed to avoid blockage of the
equipment before the first running. The equipment should be isolated from the system pipeline when clean the pipeline.
10. The power supply and power capacity provided to the equipment should be sufficient, and the power wire should be
configured in strict accordance with the data provided in the equipment power wiring requirements. The equipment should be
reliably grounded as required.
11. The chiller unit shouldn’t be installed in the places with heavy dust, dirt, corrosive gas, and high humidity.
Lifting instructions 12. The unit should be kept as horizontal as possible when moving. Do not tilt it more than 30° to avoid damage the unit.
1. During the lifting and handling process, the equipment can’t be damaged, especially for the components, pipes and frame panels
of the cooling system.
2. The lifting rope should be fixed at the lugs of the base frame, and the dedicated lifting frame should be used for lifting.
3. Move the equipment to the position by pulling or rolling, and the stress part can only be placed on the equipment chassis.
17 18