E.I.H. TELE INFRA PVT. LTD.
An ISO 9001:2015 Certified
SOIL TESTING, CONSTRUCTION MATERIAL TESTING LAB (ROAD & BUILDING)
& STRUCTURAL CONSULTANT
GEO-TECHNICAL INVESTIGATIONREPORT FOR THE
PROPOSED CONSTRUCTION OF TELECOM TOWER
Report No.: 20230303PIP2092 Date of Sampling: 13-03-2023
ULR No. TC902520000002081F Date of Report Issue: 19-03-2023
Type of Sample: Soil Sample District: SAHARANPUR
Location Mark: Latitude: 29.909765 Longitude: 77.374677
Client
M/s BSNL
Submitted to
M/s DINESH ENGINEERS LIMITED
O-2, 2nd Floor, Neighborhood Shopping Complex
Sector – 4, Nerul West, Raigad, Maharastra, 400706
Testing Agengy : M/s E I H TeleinfraPvt Ltd
Laboratory Agency: Pranvi Infra Projects and Quality Control Pvt Ltd
Village Name Village Code Site Id
BHURI BANSH 02240 UPW-RMR-SAI-116406
Registered Office:- K-2/2239, Shastri Nagar, Meerut
Address:- F-21, ShukhShant Complex, Mangal Pandey Nagar, Behind Sale Tax Office, Tejgarhi, Meerut
Contact:- 0121-3550219, 7017231183 | email:-
[email protected] ACKNOWLEDGEMENT
WE ARE GRATEFUL TO M/S. BSNL LTD FOR
PROVIDING US THE OPPORTUNITY TO CARRY OUT
THE SOIL INVESTIGATION FOR DETERMINATION OF
SAFE BEARING PRESSURE FOR THE PROPOSED
CONSTRUCTION OF TELECOM TOWER AT SITE–
BHURI BANSH, SUB-DISTRICT– NAKUD, DISTRICT–
SAHARANPUR IN UTTAR PRADESH.
Table of Contents
1. INTRODUCTION.................................................................................4
2. OBJECTIVES OF INVESTIGATION......................................................4
3. SCOPE OF WORK...............................................................................4
4. GROUND WATER...............................................................................5
5. SEISMIC ZONE..................................................................................5
6. SITE STRATIGRAPHY.........................................................................6
7. RECOMMENDATIONS:.......................................................................7
8. BEARING CAPACITY CALCULATION...................................................8
I. BEARING CAPACITY CALCULATIONS AS PER IS: 6403-1981.......................8
II. SETTLEMENT CALCULATIONS AS PER IS 8009- 1976 PART 1.....................9
9. TEST RESULT..................................................................................10
10. LIST OF REFFERED IS CODES........................................................11
11. BORELOG CHART............................................................................12
12. SITE SURVEY REPORT &SITE LAYOUT..………….………………..…………13-14
13. WORKING PHOTOS…………………………………………………………………15-17
1. INTRODUCTION
M/s. BSNL LTD has proposal for the construction of Telecom Tower at site –BHURI BANSH,
Sub-District -NAKUD, District- SAHARANPUR in UTTAR PRADESH. For the purpose of
construction, it is required to have the soil investigation data to identify the geology of the soil and
to identify the type of proposed foundation based on the reports. The work of geotechnical
investigation for the above said project was entrusted to M/s. E I H TeleinfraPvt Ltd, Aligarh,
Uttar Pradesh by M/s Dinesh Engineers Limited. The work of lab testing and report preparation
is entrusted to M/s Pranvi Infra Projects and Quality Control Pvt Ltd, Meerut, Uttar Pradesh
(An NABL accredited laboratory as per ISO/IEC 17025:2017)
The report presented herein deals with the analysis of field and laboratory test results, type and
depth of foundation and recommendations based on the type of soil and its safe bearing capacity of
soil.
2. OBJECTIVES OF INVESTIGATION
The purpose and objectives of investigation was to obtain the sub surface conditions at the site so
as to evaluate the soil parameter which are required for evaluating the safebearing capacity of soil
for the design and suitability of the foundation for the proposedstructure. The knowledge of
general geotechnical subsoil characteristics, compressibilityand information about ground water
table is an essential requirement for the geotechnical engineer, which would assist the designer to
design the foundation system.
3. SCOPE OF WORK
The detailed scope of work of geotechnical investigation for the project was limited to the
following:
Mobilization of equipment and personnel to the project site, setting up the equipment and carrying
out the field investigation and demobilization of the same after completion of fieldwork.
Drilling of one bore hole (BH-1) 150mm diameter of boring at specifiedlocation mentioned. As
per the work order it was requested to go with the manual boring upto a depth of 10.0 m bore or
N>100 achieved, whichever occurs earlier.
Conducting standard penetration test at regular depth intervals of 1.50m or at everychange of
strata whichever illustrates earlier and collect samples for further testing.
Collectionoftheundisturbedsoilsamplesateverychangeof thestrata.
Recording the depth of ground water table (If observed).
Conducting all necessary and relevant laboratory tests on representative soil
samplelimitedtofollowing:
i. Natural Moisture Content
ii. Grain Size Analysis (Sieve)
iii. Liquid and Plastic Limits
iv. Specific Gravity
v. Bulk and Dry Density
vi. Shear parameters (c & ø)
Laboratory testing for evaluating SBC as per latest IS codes. Submission of soil testing
reportwhich includes interpretation of test results and suggesting recommendations for net
safebearingcapacityofsoil.
4. GROUND WATER
Based on our measurement in the completed bore hole, water table was not encountered a
during exploration but there is a water pond nearby the structure and during rainy the
pond water may percolate in the influence soil strata below the foundation. Fluctuations
may take place due to surface evaporation rates and variation in seasonal rainfall. So, water
table rise is not adopted and water table correction is not taken for the calculations of desired
bearing capacity and settlement criteria.
5. SEISMIC ZONE
District SAHARANPUR falls under high Risk Zone-IV as per IS-1893 (Part-I) : 2016.
6. SITE STRATIGRAPHY
Based on our investigation in field and laboratory, it is revealed that the soil at site is:
BH-1: Consists of cohesive soil for up to 3.0 m from the borehole explored and than
followed by Non-cohessive strata. Detailed soil description is presented in the summery
of test results report which is attached in the annexure.
Disturbed samples were collected from the split spoon after conducting SPT. The samples are
preserved in transparent polythene bags. UDS were collected by driving 75 mm diameter thin
walled tubes using a 63.5kg hammer in accordance with IS:2132.
The tubes are sealed with wax at both ends to minimize loss of moisture. All samples were
transported to our laboratory for further examination and testing.
7. RECOMMENDATIONS:
Depth of SizeofFooting Net SafeBearing
TypeofStructure Foundation TypeofFooting Length Width Capacity
Below G.L.
(m) (m) (m) Tonne/sqm
2.00 3.00 3.00 6.0
ISOLATED SQUARE
2.50 FOOTING 3.00 3.00 7.0
TELECOM
TOWER
2.00 8.00 8.00 7.0
RAFT SQUARE
FOOTING SQUA
2.50 8.00 8.00 8.0
DECLARATION
1. The recommendations are based on the field investigation data results and laboratory tests results which are assumed by our
experience in this regards as there was no sample collected from the test locations because of refusal at that particular point
or location.
2. All the test results which are obtained by testing the samples collected in the laboratory and laboratory is not responsible if
any discrepancy is observed regarding the strata and properties of soil at the site in future.
3. Sample bearing capacity calculation and settlements are attached in Annexure-II
4. The above foundation recommendations are based on the consideration of soil replacement of atleast 0.5 m thickness
below the foundation, hence it is required to replace the soil strata of atleast 0.5 m thickness below the footing using
well graded GSB or any suitable fill.
5. If the actual sub-soil conditions during excavation for the foundations differ from that has been reported, are ference should
be made to us for suggestions.
6. Further, the recommendations are based on the assumptions as mentioned in the report and the designer of the structure should
take into consideration all the factors required as per codes.
7. There commendations should be taken as guidelines for the designer.
8. All loosesoils/debris/human waste/chemical waste material should be removed and the exposed foundation bearing surface
should be watered and compacted properly using rammers/rollers.
9. Thesurfaceshouldthenbeprotectedfromtoconstructionactivitiessothatthefoundations may be aronthenaturalundisturbed ground.
10. For open foundations, weopineplacementof100 mmthick“bindinglayer”ofleanconcretetofacilitateplacementofreinforcing steel
and to protect the soils from disturbance and also to ensure stable bed to facilitate placement of reinforcement steel.
S. Mohammad Abdul Ravish Rajput Yatendra Sharma
Technical Manager Quality Manager
Director
M.TECH (GEOTECH.) (Auth. Sign) (EIH TeleinfraPvt Ltd)
(EIH TeleinfraPvtLtd ) (Pranvi Infra Projects &
Quality Control Pvt Ltd)
8. BEARING CAPACITY CALCULATION
The Safe Bearing Capacity of the foundation of a building / structure without any
distressorfailurecanbedeterminedfromtheconsiderationofthefollowingtwocriteria.
(a) ShearFailure Criteria
Thesoilbeneaththefoundationshallbesafefromrisk ofshearfailure.
(b) SettlementFailureCriteria
The foundation shall not settle or deflect to an extent causing damage to the structure
orimpairitsusefulness.
The Bearing Capacity calculations for a foundation on shallow footing shall be governedby
I.S. 1904:1986, I.S. 6403:1981 and I.S. 8009:1976 on the basis of availableinformation
regarding the proposed design and have been done in the followingparagraphs.
Reference for the angle of internal friction taken from IS 6403:1981
9. LIST OF REFFERED IS CODES
A) FIELD INVESTIGATION
1 IS: 1498-1970 For classification and identification of soils for general
engineering purposes
2 IS: 1892-1979 Code of practice for subsurface investigations for foundations
3 IS: 2131-1981 Method of standard penetration tests for soils
4 IS: 2132-1986 Code of practice for thin walled tube sampling of soils
5 IS: 4968-1976(part-3) Method of subsurface sounding for soils: static cone
penetration test
6 IS: 4968-1976(part-1) Method of subsurface sounding for soils: dynamic cone
penetration test
B) LABORATORY TESTS
1 IS: 2720-1983 (part-1) Method of test for soil-preparation of dry soil sample for
various tests
2 IS: 2720-1980 (part-2) Method of test for soil-determination of water content
3 IS: 2720-1980 (part-3)-section-1 Method of test for soil-determination of
specific gravity of fine grained soil
4 IS: 2720-1980 (part-3)-section-2 Method of test for soil-determination of
specific gravity of coarse grained soil
5 IS: 2720-1985 (part-4) Method of test for soil-grain size analysis
6 IS: 2720-1985 (part-5) Method of test for soil-determination of liquid limits and
plastic limits
7 IS: 2720-1986 (part-15) Method of test for soil-determination of consolidation
properties
C) ANALYSIS OF BEARING CAPACITY
1 IS: 6403-1981 Code of practice for determination of bearing capacity of shallow
foundation
2 IS: 8009-1976-part-1 Code of practice for calculation of settlement of
foundation-shallow foundation