0% found this document useful (0 votes)
122 views46 pages

14 Temperature Control

The document discusses an air to water heating/cooling pump. It provides details on the product features such as being high efficiency, safe, environmentally friendly, and having advanced control systems. It also explains how the unit works in both heating and cooling modes through four stages involving a compressor, condenser, capillary tube, and evaporator coil.

Uploaded by

Ali Yazji
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views46 pages

14 Temperature Control

The document discusses an air to water heating/cooling pump. It provides details on the product features such as being high efficiency, safe, environmentally friendly, and having advanced control systems. It also explains how the unit works in both heating and cooling modes through four stages involving a compressor, condenser, capillary tube, and evaporator coil.

Uploaded by

Ali Yazji
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 46

14

TEMPERATURE
CONTROL

458 ITALY, GREAT BRITAIN, SPAIN, TURKEY, UAE, INDIA, RUSSIA

V-02
INDEX

01 AIR TO WATER HEATING /COOLING PUMp .............................. 460

02 ELECRO EVOLUTION 2 ALL TITANIUM


ANALOGUE CONTROLLER ............................................................ 476

03 OPTIMA COMPACT POOL HEATER .............................................. 478

04 SFS JOEY .......................................................................................... 480

05 TITAN OPTIMA .................................................................................. 482

06 POOL SMART PLUS .......................................................................... 484

07 HEAT SMART & KOOL SMART PLUS ............................................ 485

08 G2 HEAT EXCHANGER ................................................................... 486

09 SST HEAT EXCHANGER .................................................................. 488

10 PLATE HEAT EXCHANGER ........................................................... 490

11 AQUA POOL DEHUMIDIFIERS WITH HEATING


& COOLING FUNCTION .................................................................. 493

12 WATER TO WATER POOL HEAT PUMP........................................ 498

13 AIR COOLED WATER CHILLER ..................................................... 500

14 INDOOR POOL DEHUMIDIFIER .....................................................502

14

459

V-02
14 TEMPERATURE CONTROL

01 AIR TO WATER
HEATING /
COOLING PUMP
Air/water heating/cooling pump is part of the
AQUA product line, which indicates the swimming
pool and SPA heat pump.
Swimming pool heat pump can be used for heating
or cooling swimming pool, spa or some other open
water system.
Water system pressure should be less than 3 bar.
(Cannot be used for close water system such as air
conditioning,ground source heating and so on.)

PRODUCT FEATURES
HIGH EFFICIENCY
Adopt heat pump for heating and the
energy comes from ambient air. So its COP
can reach 5.5

SAFETY VARIOUS PROTECTIVE MEASURES


Water and electricity are completely • Lack-phase and anti-phase protection
separate. ECO friendly gas, no fire, no • Self memory function when power off
electricity leakage, safer than fuel burner • Overpressure protection
or electrical heater. • Leakage refrigerant protection
ENVIRONMENTALLY FRIENDLY • Water protection for unit
Adopt R407C, R410-A, R22 as refrigerant, • Overcurrent protection
according to the requirements of EU • Temperature over protection
Montreal Protocol.
ADVANCED CONTROL SYSTEM
CORROSION PREVENTION • Displaying operating and trouble status.
The condenser uses titanium metal, its • Checking real-time operation parameters etc.
corrosion resistance is 4-5 times of ordinary • The cable length between controller and the
copper tube, the corrosion ability of the unit unit can be up to 100m for lexible installation.
is significantly improved, while the effective • Keep balance running of compressor
way to prevent fluoride leakage. • Automatically adjusting capacity according
So the medium of heat exchange can to the change of water inlet the temperature.
also contain seawater, mild industrial • Can achieve the perfect docking with BMS.
water, etc. Realizing remote control based on user
requirement for easy management and
INTELLIGENT DEFROSTING maintenance. And can realize multi unit
modular operation
By means of both mechanical and
automatic control, defrosting can be COMPRESSOR
operated in a shorter time to avoid severe AQUA products and the world famous brand
attenuation of heating capacity in winter compressor manufacturers (COPELAND\
and not run when not necessary. GMCC) have good cooperation, so as to
ensure the high quality of the machine.
ANTIFREEZING CONTROL
The unit starts up automatic antifreezing
control when shutdown (no power off),
using of antifreezing heat exchanger, 10
freezing tests, no leakage..

460 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
HOW DOES THE
UNIT WORK?
AS A CHILLER CAPILLARY TUBE
1- STAGE ONE
The temperature of the hot gaseous refrigerant
discharged from the compressor is much higher than
the outside ambient air temperature. When the
outside air passes across the condenser coil, the
gaseous refrigerant transfers its heat to the air and
condenses into liquid.

2- STAGE TWO
The liquid refrigerant passes through the capillary
tube, reducing its pressure and temperature.

3- STAGE THREE
The low temperature refrigerant passes to the heat
exchanger evaporator, where the actual heat transfer
takes place: the refrigerant absorbs heat from the
water pumped into the heat exchanger and
evaporates, whereby the water temperature is
reduced.

4- STAGE FOUR
The gas refrigerant is then sucked to the compressor
and compressed, increasing its pressure and
temperature, ready to start the whole cycle once
again.

AS A HEAT PUMP
1- STAGE ONE
The heat transfer medium (the refrigerant) is colder
than the outside air. As the outside air passes across
the evaporator coil, the liquid refrigerant absorbs
heat from the air and evaporates.

2- STAGE TWO
The gaseous refrigerant then passes to the
compressor and is compressed. When compressed,
the pressure is increased and the temperature of the 14
vapor rises, effectively concentrating the heat.

3- STAGE THREE
The hot gaseous refrigerant passes to the heat
exchanger condenser, where the actual heat transfer
takes place: the intensely hot gaseous refrigerant
transfers its heat to the water pumped into the heat
exchanger and condenses back into a liquid.

4- STAGE FOUR
The liquid refrigerant then passes through an
capillary tube, reducing its pressure and temperature,
ready to start the whole cycle once again.

461

V-02
14 TEMPERATURE CONTROL

GAS TYPE – R410A


PH-02620-R410A PH-02625-R410A PH-02630-R410A

Refrigerant
Power supply V/PH/Hz 220/1/50 220/1/50 220/1/50
kW 9.5 12 14
Heating capacity
BTU/h 32414 40944 47768
YL-H01-Heating:
Power input kW 1.7 2.2 2.5
A24/W26°C
Current A 7.9 9.9 4.6
COP W/W 5.5 5.5 5.5
kW 8.1 10.2 11.9
Heating capacity
BTU/h 27552 34802 40603
YL-H02-Heating:
Power input kW 1.8 2.2 2.6
A15/W26°C
Current A 8.0 10.1 4.6
COP W/W 4.6 4.6 4.6
kW 7 9.0 10
Cooling capacity
BTU/h 23338 29480 34393
YL-C01-Cooling:
Power input kW 1.8 2.3 2.7
A35/W30°C
Current A 8.3 10.6 4.7
EER W/W 3.75 3.70 3.80
kW 5.814 7.3 8.6
Cooling capacity
BTU/h 19837 25058 29234
YL-C02-Cooling:
Power input kW 1.9 2.5 2.8
A46/W30
Current A 8.8 11.3 5.0
EER W/W 3.00 2.96 3.04
Water outlet temp.range C
o
15-40 15-40 15-40
OPERATING
Ambient temp.range C
o
0-53 0-53 0-53
Compressor brand GMCC GMCC COMPLAND
HEAT Compressor type Rotary*1 Scroll*1 Scroll*1
EXCHANGER Controller Micro processor based digital controller with LCD touch screen disply
Noise dB(A) 51 53 53
Power input KW 3 4 5
MAX.
Current A 12 15 7
Type Titanium /PVC Titanium /PVC Titanium /PVC
Standard water flow m3/h 4.1 5.2 6.0
Suggested water flow m /h
3
4-6 5-7 6-8
KEY
Water pressure drop(max) KPa 6 10 11
Water pipe
Water connection mm 50 50 50
Position Verticle Verticle Verticle
FAN Material Plastic Plastic Plastic
Air flow m3/h 2000 2600 3500
DIMENSIONS Net mm 688/696/737 688/696/737 764/686/941
(L x W x H) Shipping mm 736/750/895 736/750/895 795/736/1100
WEIGHT kg 63/77 70/77 95/110
Loading qty 20/40/40hq 63/144/144 63/144/144 42/96/144

462 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
PH-02640-R410A PH-02650-R410A PH-02660-R410A PH-02670-R410A PH-02700-R410A PH-02710-R410A PH-02712-R410A

380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50


17 21 25 31 35 40 45
58004 71652 85300 105772 119420 136480 153540
3.1 3.8 4.6 5.7 6.4 7.3 8.2
5.5 6.8 8.1 10.3 11.4 13.0 14.6
5.5 5.5 5.5 5.4 5.5 5.5 5.5
14.5 17.9 21.3 26.4 29.8 34.0 38.3
49303 60904 72505 89906 101507 116008 130509
3.2 3.9 4.6 5.9 6.5 7.4 8.3
5.6 6.9 8.3 10.5 11.6 13.3 14.9
4.6 4.6 4.6 4.5 4.6 4.6 4.6
12 15 18 22 25 29 32
41763 51589 61416 76156 85982 98266 110549
3.2 4.0 4.7 5.9 6.5 7.5 8.4
5.8 7.2 8.5 10.5 11.7 13.4 15.0
3.80 3.76 3.80 3.80 3.85 3.85 3.85
10.4 12.9 15.3 19.0 21.4 24.5 27.5
35498 43851 52204 64732 73085 83526 93966
3.4 4.3 5.0 6.3 7.0 7.9 8.9
6.1 7.6 9.0 11.2 12.4 14.2 16.0
3.04 3.01 3.04 3.04 3.08 3.08 3.08
15-40 15-40 15-40 15-40 15-40 15-40 5-40
0-53 0-53 0-53 0-53 0-53 0-53 0-53
COMPLAND COMPLAND COMPLAND COMPLAND COMPLAND COMPLAND COMPLAND
Scroll*1 Scroll*1 Scroll*1 Scroll*1 Scroll*1 Scroll*2 Scroll*2
Micro processor based digital controller with LCD touch screen disply
53 54 55 55 58 59 59
6 7 9 11 12 14 16 14
8 10 12 15 17 20 22
Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC
7.3 9.0 10.7 13.3 15.0 17.2 19.3
7-9 9-12 10-14 12-17 15-20 17-23 19-26
12 12 12 12 15 15 15
PPR or PVC PPR or PVC
50 50 50 63 63 63 63
Verticle Verticle Verticle Verticle Verticle Verticle Verticle
Plastic Plastic Plastic Plastic Plastic Plastic Plastic
3500 5500 5500 5500 7500 9000 10000
764/686/941 764/686/941 764/686/941 810/810/1069 860/860/1284 1453/708/1084 1453/708/1084
795/736/1110 795/736/1110 795/736/1100 915/860/1230 932/912/1418 1520/760/1235 1525/760/1235
105/115 106/120 145/155 150/160 203/210 250/270 265/285
42/96/144 42/96/144 42/196/144 42/90/90 10/22/44 10/22/44

463

V-02
14 TEMPERATURE CONTROL

GAS TYPE – R410A


PH-02713-R410A PH-02714-R410A PH-02715-R410A PH-02720-R410A

Refrigerant
Power supply V/PH/Hz 380/3/50 380/3/50 380/3/50 380/3/50
kW 55 65 80 100
Heating capacity
BTU/h 187660 221780 272960 341200
YL-H01-Heating: 10.0 11.8 14.5 18.2
Power input kW
A24/W26°C
Current A 17.9 21.1 26.0 32.5
COP W/W 5.5 5.5 5.5 5.5
kW 46.8 55.3 68.0 85.0
Heating capacity
BTU/h 159511 188513 232016 290020
YL-H02-Heating: 10.2 12.1 15.1 18.5
Power input kW
A15/W26°C
Current A 18.2 21.5 27.0 33.2
COP W/W 4.6 4.6 4.5 4.6
kW 40 47 61 72
Cooling capacity
BTU/h 135115 159682 208132 245664
YL-C01-Cooling: 10.4 12.3 16.1 19.3
Power input kW
A35/W30°C
Current A 18.6 22.0 28.7 34.4
EER W/W 3.80 3.80 3.80 3.74
kW 33.7 39.8 51.9 61.2
Cooling capacity
BTU/h 114848 135729 179812 208814
YL-C02-Cooling: 11.1 13.1 17.1 20.5
Power input kW
A46/W30
Current A 19.8 23.4 30.5 36.6
EER W/W 3.04 3.04 3.04 2.99
Water outlet temp.range o
C 5-40 15-40 15-40 15-40
OPERATING
Ambient temp.range o
C 0-53 0-53 0-53 0-53
Compressor brand COMPLAND COMPLAND COMPLAND COMPLAND

HEAT Compressor type Scroll*2 Scroll*3 Scroll*3 Scroll*4


EXCHANGER Controller Micro processor based digital controller with LCD touch screen disply
Noise dB(A) 59 62 62 62
Power input KW 20 23 29 35
MAX.
Current A 35 41 52 63
Type Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC
Standard water flow m3/h 23.6 27.9 35.3 43.0
Suggested water flow m /h
3 23.6-29 27.9-37 35-46 45-60
KEY
Water pressure drop(max) KPa 16 18 20 20
Water pipe PPR or PVC PPR or PVC PPR or PVC
Water connection mm 63 63 63 110
Position Verticle Verticle Verticle Verticle
FAN Material Plastic Plastic Plastic Plastic
Air flow m /h
3 13000 15000 18000 22000

DIMENSIONS Net mm 1453/708/1284 2145/761/1306 2145/762/1306 1420/1420/1578


(L x W x H) Shipping mm 1520/760/1455 2215/815/1455 2215/815/1455 1472/1472/1758
WEIGHT kg 285/310 400/440 510/570 580/620
Loading qty 20/40/40hq 10/22/22 7/14/14 7/14/14 7/14/14

464 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
PH-02730-R410A PH-02740-R410A PH-02750-R410A PH-02760-R410A PH-02765-R410A PH-02770-R410A PH-02780-R410A

380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50


135 160 180 220 235 250 350
460620 545920 614160 750640 801820 853000 1194200
24.5 29.1 32.7 40.0 42.7 45.5 63.6
43.9 52.0 58.5 71.5 76.4 81.3 113.8
5.5 5.5 5.5 5.5 5.5 5.5 5.5
114.8 136.0 153.0 187.0 199.8 212.5 297.5
391527 464032 522036 638044 681547 725050 1015070
24.9 29.7 33.4 41.6 43.6 46.4 64.9
44.8 53.1 59.7 74.3 77.9 82.9 116.0
4.6 4.6 4.6 4.5 4.6 4.6 4.6
97 115 130 154 169 180 252
331646 393062 442195 525448 557310 614160 859824
25.9 30.9 34.6 40.5 44.5 47.4 66.3
46.4 55.2 61.8 72.4 79.6 84.7 118.5
3.74 3.73 3.75 3.80 3.80 3.80 3.80
82.6 97.9 110.2 130.9 143.8 153.0 214.2
281899 334103 375866 446631 490714 522036 730850
27.6 32.8 36.7 43.1 47.3 50.3 70.5
49.3 58.7 3.00 77.0 84.6 90.0 125.9
2.99 2.98 3.00 3.04 3.04 3.04 3.04
15-40 15-40 15-40 15-40 15-40 15-40 15-40
0-53 0-53 0-53 0-53 0-53 0-53 0-53
COMPLAND COMPLAND COMPLAND COMPLAND COMPLAND COMPLAND COMPLAND
Scroll*5 Scroll*6 or 3 Scroll*7 or 3 Scroll*8 or 4 Scroll*10 or 4 Scroll*10 or 4 Scroll*10 or 4
Micro processor based digital controller with LCD touch screen disply
62 65 65 65 65 68 68
48 57 64 78 83 89 124 14
86 101 114 139 149 158 222
Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC
58.0 68.8 77.4 94.6 101.0 107.5 150.5
58-65 68.91 77-103 90-120 101-125 107-143 150-160
22 23 24 25 25 26 28
PPR or PVC PPR or PVC PVC PVC
110 110 110 110 110 160 160
Verticle Verticle Verticle Verticle Verticle Verticle Verticle
Plastic Plastic Plastic Plastic Plastic Plastic Plastic
33000 33000 39000 44000 44000 60000 77000
2185/1767/1388 2185/1767/1388 2185/1767/1540 2185/1765/1540 2185/1767/1540 2188/2188/2236 3280/2188/2236
2235/1820/1550 2235/1820/1550 2235/1820/1695 2235/1820/1695 2235/1820/1695 2240/2240/2400 3332/2240/2400
820/870 928/960 1180/1230 1044/1080 1276/1320 1420/1470 2050/2180
3/6/6 3/6/6 3/6/6 3/6/6 2/5/5 2/5/5 2/5/5

465

V-02
14 TEMPERATURE CONTROL

SWIMMING POOL HEAT


PUMP -PHFD
PHFD- PHFD- PHFD-
02610-R410A 02615-R410A 02620-R410A
Power supply V/PH/HZ 220-240/1/50
kW 5 7.3 9.8
Heating capacity
BTU/h 17060 24907.6 33437.6
YL-H01-Heating:
Power input kW 0.9 1.3 1.8
A24/W26°C
Current A 4.1 6.0 8.1
COP W/W 5.5 5.5 5.5
kW 4.3 6.2 8.3
Heating capacity
BTU/h 14501 21171.5 28422.0
YL-H02-Heating:
Power input kW 0.9 1.4 1.8
A15/W26°C
Current A 4.2 6.2 8.3
COP W/W 4.6 4.6 4.6
kW 3.2 4.6 6.2
Heating capacity
BTU/h 10748 15691.8 21066.7
YL-H03-Heating:
Power input kW 0.8 1.2 1.7
A7/W26°C
Current A 3.8 5.6 7.5
COP W/W 3.7 3.7 3.7
kW 3.6 5.3 7.1
Cooling capacity
BTU/h 12283.2 17933.5 24075.1
YL-C01-Cooling:
Power input kW 1.0 1.4 1.9
A35/W30°C
Current A 4.4 6.4 8.6
EER W/W 3.8 3.8 3.8
kW 3.1 4.5 6.0
Cooling capacity
BTU/h 10440.7 15243.5 20463.8
YL-C02-Cooling:
Power input kW 1.0 1.5 20
A46/W30°C
Current A 4.6 6.8 9.1
EER W/W 3.0 3.0 3.0
Power input kW 1.4 2 2.7
MAX
Current A 6.2 9 12.1
Water outlet temp.range o
C 15-40 15-40 15-40
OPERATING
Ambient temp.range o
C 0-53 0-53 0-53
Compressor type Rotary Rotary Rotary
KEY
Noise dB(A) 47 50 51
Type Titanium / PVC Titanium / PVC Titanium / PVC
Standard water flow m /h
3
2.1 3.1 4.2
HEAT
Water pressure drop(max) KPa 4 6 6
EXCHANGER
Water pipe
Water connection mm 50 50 50
Position Horizontal Horizontal Horizontal
FAN
Material 1200 2000 2000
DIMENSIONS Net mm 932 x 355 x 515 1003 x 350 x 627 1003 x 350 x 627
(L x W x H) Shipping mm 980 x 335 x 676 1085 x 355 x 770 1085 x 355 x 770
WEIGHT kg 48/55 50/58 50/63

466 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
PHFD- PHFD- PHFD- PHFD- PHFD- PHFD-
02625-R410A 02630-R410A 02630-R410A 02640-R410A 02650-R410A 02660-R410A
220-240/1/50 380-415/3/50
12 14 14 17 21 25
40944 47768 47768 58004 71652 85300
2.2 2.6 2.5 3.1 3.8 4.5
9.9 11.6 4.6 5.5 6.8 8.1
5.5 5.5 5.5 5.5 5.5 5.5
10.2 11.9 11.9 14.5 17.9 21.3
34802.4 40602.8 40602.8 49303.4 60904.2 72505
2.2 2.6 2.6 3.2 3.9 4.6
10.1 11.9 4.6 5.6 6.9 8.3
4.6 4.6 4.6 4.6 4.6 4.6
7.6 8.8 8.8 10.7 13.2 15.8
25794.7 30093.8 30093.8 36542.5 45140.1 53739
2.0 2.4 2.4 2.9 3.5 4.2
9.2 10.8 4.2 5.1 6.3 7.6
3.7 3.7 3.7 3.7 3.7 3.7
8.6 10.1 10.1 12.2 15.1 18
29479.7 34393.0 34393 41762.9 51589.4 61416
2.3 2.7 2.7 3.2 4.0 4.7
10.6 12.4 4.7 5.8 7.2 8.5
3.7 3.7 3.8 3.8 3.8 3.8
7.3 8.6 8.6 10.4 12.9 15.3
25057.7 29234 29234 35498.4 43851.0 52203.6
2.5 2.9 2.8 3.4 4.3 5.0
11.3 13.2 5.0 6.1 7.6 9.0
3.0 3.0 3.0 3.0 3.0 3.04
3.3 3.8 3.8 4.6 5.7 6.8
14.9 17.5 17.4 21.1 25.9 31.0 14
15-40 15-40 15-40 15-40 15-40 15-40
0-53 0-53 0-53 0-53 0-53 0-53
Rotary Rotary Scroll Scroll Scroll Scroll
53 53 53 53 54 55
Titanium / PVC Titanium / PVC Titanium / PVC Titanium / PVC Titanium / PVC Titanium / PVC
5.2 6.0 6.0 7.3 9.0 10.7
10 11 11 12 12 12

50 50 50 50 50 50
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
2600 3500 3500 3500 5500 5500
1003 x 350 x 627 1088 x 388 x 687 1088 x 388 x 687 1088 x 388 x 987 1088 x 388 x 987 1088 x 388 x 1287
1085 x 355 x 770 1130 x 445 x 830 1130 x 445 x 830 1130 x 445 x 1130 1130 x 445 x 1130 1130 x 445 x 1430
63/70 77/97 77/97 95/110 105/115 120/135

467

V-02
14 TEMPERATURE CONTROL

SWIMMING POOL HEAT


PUMP -PHFD
PHFD- PHFD- PHFD-
02670-R410A 02710-R410A 02712-R410A
Power supply V/PH/Hz 380-415/3/50
kW 31 40 45
Heating capacity
BTU/h 105772 136480 153540
YL-H01-Heating:
Power input kW 5.6 7.3 8.2
A24/W26°C
Current A 10.1 13.0 14.6
COP W/W 5.5 5.5 5.5
kW 26.4 34.0 38.3
Heating capacity
BTU/h 89906.2 116008 130509
YL-H02-Heating:
Power input kW 5.7 7.4 8.3
A15/W26°C
Current A 10.3 13.3 14.9
COP W/W 4.6 4.6 4.6
kW 19.5 25.2 28.4
Heating capacity
BTU/h 66636.4 85982 96730.2
YL-H03-Heating:
Power input kW 5.2 6.8 7.6
A7/W26°C
Current A 9.4 12.1 13.6
COP W/W 3.7 3.7 3.7
kW 22.3 28.8 32.4
Cooling capacity
BTU/h 76155.8 98265.6 110548.9
YL-C01-Cooling:
Power input kW 5.9 7.5 8.4
A35/W30°C
Current A 10.5 13.4 15.0
EER W/W 3.8 3.9 3.9
kW 19.0 24.5 27.5
Cooling capacity
BTU/h 64732.5 83525.8 93966.5
YL-C02-Cooling:
Power input kW 6.2 7.9 8.9
A46/W30°C
Current A 11.2 14.2 16.0
EER W/W 3.0 3.1 3.1
Power input kW 8.5 10.9 12.3
MAX
Current A 38.4 49.6 55.8
Water outlet temp.range o
C 15-40 15-40 15-40
OPERATING
Ambient temp.range o
C 0-53 0-53 0-53
Compressor type Scroll Scroll Scroll
KEY
Noise dB(A) 59 59 59
Type Titanium / PVC Titanium / PVC Titanium / PVC
Standard water flow m3/h 13.3 17.2 19.3
HEAT
Water pressure drop(max) KPa 15 15 15
EXCHANGER
Water pipe PPR or PVC PPR or PVC PPR or PVC
Water connection mm 63 63 63
Position Horizontal Horizontal Horizontal
FAN
Material 7000 9000 1000
DIMENSIONS Net mm 1088 x 388 x 1487 1454 x 752 x 1703 1454 x 752 x 1703
(L x W x H) Shipping mm 1130 x 445 x 1630 1505 x 880 x 1845 1505 x 880 x 1845
WEIGHT kg 130/145 250/270 265/285

468 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
PHFD- PHFD- PHFD- PHFD- PHFD- PHFD-
02713-R410A 02714-R410A 02715-R410A 02720-R410A 02730-R410A 02740-R410A
380-415/3/50
55 65 82 105 135 158
187660 221780 279784 358260 460620 539096
10.0 11.8 14.9 19.1 24.5 28.7
17.9 21.1 26.7 34.1 43.9 51.4
5.5 5.5 5.5 5.5 5.5 5.5
46.8 55.3 69.7 89.3 114.8 134.3
159511 188513 237816.4 304521.0 391527 458231.6
10.2 12.1 15.2 19.5 25.0 29.3
18.2 21.5 27.2 34.8 44.8 52.4
4.6 4.6 4.6 4.6 4.6 4.6
34.7 41.0 51.7 66.2 85.1 99.5
118225.8 139721.4 176263.9 225703.8 290190.6 339630.5
9.3 11.0 13.9 17.8 22.8 26.7
16.6 19.6 24.8 31.7 40.8 47.8
3.7 3.7 3.7 3.7 3.7 3.7
39.6 46.8 59 75.6 97.2 113.8
135115.2 159681.6 201444.5 257947.2 331646.4 388149.1
10.4 12.3 15.5 20.2 26.0 30.5
18.6 22.0 27.8 36.1 46.5 54.5
3.8 3.80 3.8 3.7 3.7 3.7
33.7 39.8 50.2 64.3 82.6 96.7
114847.9 135729.4 17122.8 219255.1 281899.4 329926.8
11.1 13.1 16.5 21.5 27.6 32.4
19.8 23.4 29.5 38.4 49.4 57.9
3.0 3.0 3.0 3.0 2.99 3.0
15.0 17.7 22.4 28.6 36.8 43.1
68.2 80.6 101.7 130.2 167.4 195.9
14
15-40 15-40 15-40 15-40 15-40 15-40
0-53 0-53 0-53 0-53 0-53 0-53
Scroll Scroll Scroll Scroll Scroll Scroll
59 62 62 62 62 65
Titanium / PVC Titanium / PVC Titanium / PVC Titanium / PVC Titanium / PVC Titanium / PVC
23.6 27.9 35.3 45.1 58.0 67.9
16 18.0 20 20 22 23
PPR or PVC PPR or PVC PPR or PVC
63 63 63 110 110 110
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
13000 15000 18000 22000 28000 33000
1454 x 752 x 1703 2188 x 752 x 1703 2188 x 752 x 1703 1454 x 752 x 2103 2188 x 860 x 2248 2188 x 860 x 2248
1505 x 880 x 1845 2240 x 880 x 1845 2240 x 880 x 1845 1505 x 880 x 2245 2240 x 990 x 2390 2240 x 990 x 2390
285/310 400 x 440 490/540 540/600 820/870 910/950

469

V-02
14 TEMPERATURE CONTROL

UNIT DIMENSIONS: PH

DIMENSIONS (mm)
CODE
A B C D E F G H
PH-02620
666 445 688 125 696 95 330 737
PH-02625
PH-02630
PH-02640
724 450 764 118 686 106 420 941
PH-02650
PH-02660
PH-02670 800 582 810 114 810 121 380 1069
PH-02700 838 581 860 140 860 158 420 1284

DIMENSIONS (mm)
CODE
A B C D E F G
PH-02710
1453 830 656 708 1084 130 420
PH-02712
PH-02713 1453 830 656 708 1284 130 500

470 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
DIMENSIONS (mm)
CODE
A B C D E F G H
PH-02714
2145 900 690 - 764 1306 169 500
PH-02715

14

DIMENSIONS (mm)
CODE
A B C D E
PH-02720 1420 1100 1420 1578 310

471

V-02
14 TEMPERATURE CONTROL

DIMENSIONS (mm)
CODE
A B E F G H
PH-02730
2185 882 1767 1388 223 500
PH-02740
PH-02750
2185 714 1767 1540 221 500
PH-02760

DIMENSIONS (mm)
CODE
A B C D E F G
PH-02770 2188 2086 2010 1680 297 450 2236
PH-02780 3281 3186 2188 2680 265 380 2236

472 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
UNIT DIMENTIONS: PHFD

DIMENSIONS (mm)
CODE
A B C D E F G
PHFD-02610 932 515 303 355 -- 330 111
PHFD-02615
PHFD-02620 1003 627 303 350 -- 330 111
PHFD-02625

DIMENSIONS (mm)
CODE 14
A B C D E F G
PHFD-02630 1088 388 687 365 650 420 115
PHFD-02640
1088 388 987 368 650 500 115
PHFD-02650

473

V-02
14 TEMPERATURE CONTROL

DIMENSIONS (mm)
CODE
A B C D E F G
PHFD-02660 1287 1088 388 365 650 420 637
PHFD-02670 1487 1088 388 365 650 420 687

DIMENSIONS (mm)
CODE
A B C D E F G
PHFD-02710
PHFD-02712 1703 1454 752 666 654 420 156
PHFD-02713

474 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
DIMENSIONS (mm)
CODE
A B C D E F G
PHFD-02714
2188 1703 752 666 681 420 156
PHFD-02715

DIMENSIONS (mm)
CODE
A B C D E F G
PHFD-02720 1454 2103 752 774 654 500 156

14

DIMENSIONS (mm)
CODE
A B C D E F G
PHFD-02730
2188 2248 860 774 681 500 216
PHFD-02740

475

V-02
14 TEMPERATURE CONTROL

02 ELECRO EVOLUTION 2
ALL TITANIUM

• Ten power options ranging from 1-kW to 24-kW

• Easy installation, fully equipped and pre-wired

• Robust, durable construction

• Ultra-reliable flow switch allows safe operation

• Temperature thermostat and overheating sensor

• Compact, durable design

• Analogue control with 1.2°C differential or


digital control With 0.5°C differential and
selectable multi-lingual display

• Titanium flow tube and titanium heating element

• Can be floor or vertically wall mounted

• Vortex, long life, stay clean heating element


technology

• 100% efficiency throughout the product life

• Silent operation

SPECIFICATIONS

POWER SUPPLY Single phase or three phase


FLOW REQUIREMENTS Minimum flow: 2 kW to 6 kW, 1m³/h / Minimum flow: 9 kW to 24 kW, 4m³/h / Maximum flow: 17m³/h
HEATING ELEMENTS Grade 1 titanium
FLOW TUBE Grade 1 titanium
CONTROL THERMOSTAT Analogue: 0 > 45°C (1.2°C differential) Digital: 0 > 45°C (0.5°C differential)
SAFETY THERMAL CUT OUT 60°C (Manual reset)
FLOW SWITCH Gold tipped reed switch with titanium fulcrum pin
CONTACTOR Siemens 3RT2023 or 3RT2027
SEALS High temperature special formula EPDM ferrules, TPE end fitting gaskets
WATER CONNECTIONS 1.5” BSP female thread supplied with 1½”/50mm stepped ABS unions for rigid pipe
and 1½”/1¼” stepped hose tails for flexible pipe
INGRESS PROTECTION RATING IP 44
FREQUENCY 50/60 Hz
WORKING PRESSURE 4 bar maximum
MOUNTING Floor or wall mounting

476 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
UP TO 6-KW SINGLE PHASE

9 & 12-KW SINGLE PHASE

15 & 18-KW SINGLE PHASE


& ALL 3-PHASE

POWER OUTPUT LOAD DIMENSIONS WEIGHT VOLUME


CODE CURRENT PACKING
kW Amp L kg m3
E2-1-1 1 6 462 1 5.5 0.059
E2-1-2 2 9 462 1 5.5 0.059
E2-1-3 3 13 462 1 5.5 0.059
E2-1-4 4.5 20 462 1 5.5 0.059
220~240V
E2-1-6 6 27 462 1 5.5 0.059
Single phase
E2-1-9 9 40 462 1 5.8 0.059
E2-1-12 12 53 462 1 5.8 0.059
E2-1-15 15 66 462 1 6.6 0.059
E2-1-18 18 79 462 1 6.6 0.059
E2-V-6 6 27/9 592 1 6.6 0.059
230~400V
E2-V-9 9 40/13 592 1 6.6 0.059
Single/3 phase
E2-V-12 12 53/18 592 1 6.6 0.059
E2-V-15 15
400V
22 592 1 6.6 0.059 14
E2-V-18 18 26 592 1 6.6 0.059
3 phase
E2-V-24 24 35 592 1 6.6 0.059
E2D-1-1 1 6 592 1 6.6 0.059
E2D-1-2 2 9 592 1 6.6 0.059
E2D-1-3 3 13 592 1 6.6 0.059
E2D-1-4 4.5 20 592 1 6.6 0.059
220~240V
E2D-1-6 6 27 592 1 6.6 0.059
Single phase
E2D-1-9 9 40 592 1 6.6 0.059
E2D-1-12 12 53 592 1 6.6 0.059
E2D-1-15 15 66 592 1 6.6 0.059
E2D-1-18 18 79 592 1 6.6 0.059
E2D-V-6 6 27/9 592 1 6.6 0.059
230~400V
E2D-V-9 9 40/13 592 1 6.6 0.059
Single/3 phase
E2D-V-12 12 53/18 592 1 6.6 0.059
E2D-3-15 15 22 592 1 6.6 0.059
400V
E2D-3-18 18 26 592 1 6.6 0.059
3 phase
E2D-3-24 24 35 592 1 6.6 0.059

477

V-02
14 TEMPERATURE CONTROL

03 OPTIMA
COMPACT POOL
HEATER
• Nine power options ranging from 2-kW to 24-kW

• Easy installation, fully equipped and pre-wired

• Robust, durable construction

• Ultra-reliable flow switch allows safe operation

• Fitted with temperature thermostat and


overheating sensor

• Compact, durable design

• Touchscreen control with soft-start for power


supply protection

• Titanium flow tube and titanium heating element

• Can be floor or vertically wall mounted

• Vortex, long life, stay clean heating element


technology

• 100% efficiency throughout the product life

• Silent operation

SPECIFICATIONS

POWER SUPPLY Single phase or three phase


FLOW REQUIREMENTS Minimum flow: 2 kW to 6 kW, 1m³/h / Minimum flow: 9 kW to 24 kW, 4m³/h / Maximum flow: 17m³/h
HEATING ELEMENTS Grade 1 titanium
FLOW TUBE Grade 1 titanium
CONTROL THERMOSTAT Touch Screen 0 > 45°C (0.5°C differential)
SAFETY THERMAL CUT OUT 60°C (Manual reset)
FLOW SWITCH Gold tipped reed switch with titanium fulcrum pin
CONTACTOR Siemens 3RT2023 or 3RT2027
SEALS High temperature special formula EPDM ferrules, TPE end fitting gaskets
WATER CONNECTIONS 1.5” BSP female thread supplied with 1½”/50mm stepped ABS unions for rigid pipe
and 1½”/1¼” stepped hose tails for flexible pipe
INGRESS PROTECTION RATING IP 44
FREQUENCY 50/60 Hz
WORKING PRESSURE 4 bar maximum
MOUNTING Floor or wall mounting

478 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
UP TO 6-KW SINGLE PHASE

9 & 12-KW SINGLE PHASE

15 & 18-KW SINGLE PHASE


& ALL 3-PHASE

POWER OUTPUT LOAD WEIGHT VOLUME


CODE CURRENT PACKING
kW Amp kg m3
OCPD-1-2 2 9 1 8.8 0.059
OCPD-1-3 3 13 1 8.8 0.059
OCPD-1-4 4.5 20 1 8.8 0.059
OCPD-1-6 6 27 1 8.8 0.059
220~240V
OCPD-1-9 9 40 1 9.2 0.059
Single phase
OCPD-1-12 12 53 1 9.2 0.059
OCPD-1-15 15 66 1 9.7 0.059
OCPD-1-18 18 79 1 9.7 0.059
OCPD-V-6 6 27/9 1 9.7 0.059
OCPD-V-9 9 40/13 1 9.7 0.059
OCPD-V-12 12
230~400V
53/18 1 9.7 0.059
14
Single/3 phase
OCPD-3-15 15 22 1 9.7 0.059
OCPD-3-18 18 400V 26 1 9.7 0.059
OCPD-3-24 24 3 phase 35 1 9.7 0.059

479

V-02
14 TEMPERATURE CONTROL

04 SFS JOEY

• Various power options ranging from 18-kW


to 120-kW

• Easy installation, fully equipped and pre-wired

• Robust, durable construction

• Ultra-reliable flow switch allows safe operation

• Fitted with temperature thermostat and


overheating sensor

• Compact, durable design

• Analogue control with 1.2°C differential or


digitalcontrol with 0.5°C differential and
selectable multi-lingual display

• Titanium flow tube and titanium heating element

• Can be floor or vertically wall mounted

• Vortex, long life, stay clean heating element


technology

• 100% efficiency throughout the product life

• Silent operation

SPECIFICATIONS

POWER SUPPLY Single phase or three phase


FLOW REQUIREMENTS Minimum flow: 7m³/h / Maximum flow: 15m³/h / Recommended flow: 8m³/h
HEATING ELEMENTS Grade 1 titanium
FLOW TUBE Grade 1 titanium
CONTROL THERMOSTAT Analogue: 0 > 45°C (1.2°C differential)/Digital: 0 > 45°C (0.5°C differential)
SAFETY THERMAL CUT OUT 65°C safety thermal cut out (auto reset) against enclosure over-temperature 60°C safety thermal cut
out (manual reset)
FLOW SWITCH Gold tipped reed switch with titanium fulcrum pin
CONTACTOR Cascade wired dual Siemens 3RT2023 or 3RT2027 for each element bank
SEALS High temperature special formula EPDM ferrules, TPE end fitting gaskets
WATER CONNECTIONS 63mm spigot with 2”/63mm stepped ABS unions
INGRESS PROTECTION RATING IP 44
FREQUENCY 50/60 Hz
WORKING PRESSURE 4 bar maximum
MOUNTING Floor or wall mounting

480 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
18,24,30 & 36-KW

45,54,60 & 72 - KW

96-KW

120-KW

18,24,30 & 36-KW

45 & 54-KW

90 & 72-KW

90-KW

POWER OUTPUT LOAD DIMENSIONS WEIGHT VOLUME


CODE CURRENT PACKING
kW Amp L kg m3
SFS-18 18 26 699 1 26 0.20
SFS-24 24 35 699 1 26 0.20
SFS-30 30 44 699 1 26 0.20
SFS-36 36 53 699 1 26 0.20
SFS-45 45 66 699 1 28 0.20
SFS-54 54 79 699 1 28 0.20 14
SFS-60 60 87 699 1 28 0.20
SFS-72 72 105 699 1 28 0.20
SFS-96 96 139 1042 1 44 0.28
SFS-120 120 400V 174 1042 1 44 0.28
SFSD-18 18 3 phase 46 699 1 26 0.20
SFSD-24 24 61 699 1 26 0.20
SFSD-30 30 76 699 1 26 0.20
SFSD-36 36 91 699 1 26 0.20
SFSD-45 45 114 699 1 28 0.20
SFSD-54 54 136 699 1 28 0.20
SFSD-60 60 151 1042 1 44 0.28
SFSD-72 72 181 1042 1 44 0.28
SFSD-96 96 1042 1 44 0.28
SFSD-120 120

481

V-02
14 TEMPERATURE CONTROL

05 TITAN OPTIMA

• Various power options ranging from 18-kW to


120-kW

• Easy installation, fully equipped and pre-wired

• Robust, durable construction

• Ultra-reliable flow switch allows safe operation

• Supplied with temperature thermostat and


overheating sensor

• Compact, durable design

• Touchscreen control with soft-start for power


supply protection

• Titanium flow tube and titanium heating element

• Can be floor or vertically wall mounted

• Vortex, long life, stay clean heating element


technology

• 100% efficiency throughout the product life

• Silent operation

SPECIFICATIONS

POWER SUPPLY Single phase or three phase


FLOW REQUIREMENTS Minimum flow: 12m³/h / Recommended flow: 30m³/h / Maximum flow: 45m³/h
HEATING ELEMENTS Grade 1 titanium
FLOW TUBE Grade 1 titanium
CONTROL THERMOSTAT Touchscreen 0 > 45°C (0.5°C differential)
SAFETY THERMAL CUT OUT 65°C safety thermal cut out (auto reset) against enclosure over-temperature 60°C safety thermal cut
out (manual reset)
FLOW SWITCH Gold tipped reed switch with titanium fulcrum pin
CONTACTOR Cascade wired dual Siemens 3RT2023 or 3RT2027 for each element bank
SEALS High temperature special formula EPDM ferrules, TPE end fitting gaskets
WATER CONNECTIONS 63mm spigot with 2”/63mm stepped ABS unions
INGRESS PROTECTION RATING IP 44
FREQUENCY 50/60 Hz
WORKING PRESSURE 4 bar maximum
MOUNTING Floor or wall mounting

482 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
18,24,30 & 36-KW

45,54,60 & 72 - KW

96-KW

120-KW

18,24,30 & 36-KW

45 & 54-KW

90 & 72-KW

90-KW

POWER OUTPUT LOAD DIMENSIONS WEIGHT VOLUME


CODE CURRENT PACKING
kW Amp L kg m3
CP-TS-18 18 26 699 1 25.8 0.20
CP-TS-24 24 35 699 1 25.8 0.20
CP-TS-30 30 44 699 1 25.8 0.20 14
CP-TS-36 36 53 699 1 25.8 0.20
CP-TS-45 45 400V 66 699 1 28.0 0.20
CP-TS-54 54 3 phase 79 699 1 28.0 0.20
CP-TS-60 60 87 699 1 28.0 0.20
CP-TS-72 72 105 699 1 28.0 0.20
CP-TS-96 96 139 1042 1 43.8 0.28
CP-TS-120 120 174 1042 1 43.8 0.28

483

V-02
14 TEMPERATURE CONTROL

06 POOL SMART
PLUS

Touchscreen Heating Controller for swimming pools,


comes with flow switch and temperature sensor
for accurate monitoring and maintaining water
temperature.

• Smart touchscreen display

• BMS (Building Management System) Integration


Ready

• Multi-lingual interface

• Programmable 24-hour time clock (4 time zones)

• Flow and temperature sensor ports

• Accurate control to 0.5ºC

• Diagnostic display

253

T-PIECE 50MM AND 1.5 “ REDUCERS


180 55

SPECIFICATIONS

POWER SUPPLY Single phase 100-240V


AVAILABLE MODELS Heating only
CONTROL THERMOSTAT Digital: 0 > 45°C (0.5°C differential)
TEMPERATURE SENSOR 3 metre long (thermistor 103AT-2, R25=10K B=3435K)
FLOW SWITCH 3 metre long with gold tipped reed switch with titanium fulcrum pin
INGRESS PROTECTION RATING IP 44
FREQUENCY 50/60Hz
MOUNTING Wall mounting

WEIGHT VOLUME
CODE DESCRIPTION OUTPUTS ACCESSORIES PACKING
kg m3
3 meter long flow switch
Volt free heating output
Pool heating 3 meter long temperature sensor
PSPC-POOL Volt free filtration pump 1 1.6 0.013
controller T-piece with 50mm and 1.5”
output
reducers

484 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
07 HEAT SMART &
KOOL SMART PLUS

• Smart touchscreen display

• BMS (Building Management System) Integration


Ready

• Multi-lingual interface

• Programmable 24-hour time clock (4 time zones)

• Flow and temperature sensor ports

• Accurate control to 0.5ºC

• Diagnostic display

253

GRUNDFOS FLOW SWITCH AND


BUSTER PUMP TEMPERATURE SENSOR

SPECIFICATIONS

POWER SUPPLY Single phase 100-240V


AVAILABLE MODELS Heating only /Cooling only
CONTROL THERMOSTAT Digital: 0 > 45°C (0.5°C differential)
TEMPERATURE SENSOR 1 metre long (thermistor 103AT-2, R25=10K B=3435K)
FLOW SWITCH Gold tipped reed switch with titanium fulcrum pin 14
INGRESS PROTECTION RATING IP 44
FREQUENCY 50/60Hz
MOUNTING Wall mounting
OPTIONAL ACCESSORIES Grundfos Booster Pump

WEIGHT VOLUME
CODE DESCRIPTION OUTPUTS ACCESSORIES PACKING
kg m3
1 metre long flow switch
Heat exchanger
PSPC-HE Volt free heating output 1 metre long 1 1.6 0.013
controller
Volt free filtration pump temperature sensor
output 220-240V Booster Grundfos Booster Pump
Heat exchanger Pump output
PSPC-HE-GP 1 metre long flow switch 1 3.5 0.021
controller
1 metre long temperature sensor
1 metre long flow switch
Heat exchanger
KSPC-HE 1 metre long 1 1.6 0.013
controller Volt free heating output temperature sensor
Volt free alarm pump
output Grundfos Booster Pump
Heat exchanger
KSPC-HE-GP 1 metre long flow switch 1 3.5 0.021
controller
1 metre long temperature sensor

485

V-02
14 TEMPERATURE CONTROL

08 G2 HEAT
EXCHANGER

• The G2 Heat Exchanger is manufactured from top


quality components and materials.
• Robust, durable construction.
• Titanium tube bundle - salt and sea water safe
• BS 316L Stainless Steel shell with special
polyamide fittings
• Wall mountable (bracket supplied)

DOSING UNIT
CHEMICAL
POOL

UV SYSTEM
• Available with fully equipped Analogue or Digital
control (optional).
• The heat exchanger construction gives a vast heat
transfer surface area, consisting of a densely
populated multi-tubular bundle, secured by the
uniquely designed polyamiderubber tube sheet.
• The heat exchanger shell is constructed from

NON RETURN
BS 316L Stainless Steel enclosed by a rigid

VALVE
PUMP
thermal shell for enhanced insulation of the
primary (HOT) water, enabling even greater heat
transfer; this is capped at each end with primary FILTER
BOILER

and secondary moulded fittings manufactured PUMP HEAT EXCHANGER

from specially formulated polymer alloy material.


• The standard G2 heat exchanger is supplied
complete with:
- 2 x 1” male/male Brass Primary connections.
- 1 x 1” Non-Return Valve.
- Titanium thermostat pocket.
- 1 x Blanking Cap and Gasket (for non-thermostat
side).
• The G2 Heat Exchanger has been designed to
allow the installation engineer to select which
way to plumb the primary and secondary water
to achieve maximum thermal gain; this is
achieved by routing the primary flow in an
opposing direction to the secondary (POOL) water.
• The G2 heat exchanger is installed in the pool
filtration circuit from which water passes
through the tube side of the exchanger. Water
from the primary heating circuit flows counter-
current through the shell side of the exchanger,
heating the swimming pool water. Ideal for use
with gas or oil fired boiler circuits, solar panels,
heat pumps or chillers.
• Tube bundle: Pure titanium.
• Water connections:
- Primary 1” BSP male (brass fittings supplied).
- Secondary (POOL): 1.5” or 50 mm NB adapters for
connection to PVC or ABS pipe.
• Working pressure: 4 bar maximum.

486 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
PRESSURE DROP SECONDARY CIRCUIT
G2-HE-30T

G2-HE-49T

G2-HE-85T

G2-HE-122T

PRESSURE DROP PRIMARY CIRCUIT

G2-HE-30T

G2-HE-49T

G2-HE-85T

G2-HE-122T

L3

131

L2
L1

STANDARD POWER OUTPUT DIMENSIONS WEIGHT VOLUME


CODE PACKING
kW BTU L1 L2 L3 kg m3
G2-HE-30T 30 102K 540 426 247 1 3.9 0.016
G2-HE-49T 49 167K 710 596 417 1 5.0 0.021
G2-HE-85T 85 290K 840 726 547 1 6.3 0.026
G2-HE-122T 122 416K 1000 886 707 1 7.6 0.037 14
PRIMARY PRIMARY SECOND- SECOND-
▲T ▲T ▲T ▲T ▲T ▲T ▲T
(HOT) (HOT) ARY (POOL) ARY (POOL)
CODE 15°C 20°C 30°C 40°C 50°C 60°C 70°C
FLOW HEAD LOSS FLOW HEAD LOSS
m3 kPa m3 m3 kW kW kW kW kW kW kW
1.1 6.1 10 5 9 11 16 20 26 30 33
G2-HE-30T 1.3 6.8 10 5 10 13 18 23 31 34 39
1.3 6.8 14 7 11 15 20 26 34 41 46
1.6 7.7 16 9.2 13 18 25 33 41 50 56
G2-HE-49T 1.8 8.3 16 9.2 14 20 28 38 45 55 62
2.2 9.3 17 9.8 16 22 33 44 52 64 73
2.4 11.3 17 10.6 22 28 40 53 64 75 81
G2-HE-85T 2.7 12.9 17 10.6 26 32 46 60 73 82 89
3.2 14.7 17 10.6 28 34 49 64 77 90 102
3.8 18.3 19 12.6 33 43 68 75 93 108 120
G2-HE-122T 4.2 20 19 12.6 36 48 70 89 108 126 143
4.6 21.1 19 12.6 38 53 73 95 116 137 156

487

V-02
14 TEMPERATURE CONTROL

09 SST HEAT
EXCHANGER

• Four models ranging from 36-kW to 95-kW

• Special formulated polymer

• Coiled titanium primary casing

• Salt and sea water compatible

• 30 bar (primary) and 3 bar (secondary) pressure


tolerance

• Low pressure drop

• With optional Smart Touchscreen Controller &


Booster Pump

• Temperature and flow sensor port

• Floor or wall mountable

PRIMARY CIRCUIT

FLOW TUBE COILED TITANIUM


WATER CONNECTIONS 1” BSP MALE FITTING
FLOW TUBE 30 BAR MAXIMUM

SECONDARY CIRCUIT

FLOW TUBE SPECIAL FORMULATED POLYMER


WATER CONNECTIONS 21/2”/63 MM STEPPED ABS UNIONS FOR RIGID PIPE CONNECTION WITH 1/1/2”/50MM REDUCERS
FLOW TUBE 30 BAR MAXIMUM

488 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
SST-36

SST-50

SST-75

SST-95

SST-36

SST-50

SST-75

SST-95

STANDARD POWER OUTPUT DIMENSIONS WEIGHT VOLUME


CODE PACKING
kW BTU A B C kg m3
SST-36 36 123 290 143 478 1 5.8 0.055
SST-50 50 171 386 240 574 1 6.4 0.055
SST-75 75 256 530 384 718 1 7.6 0.075 14
SST-95 95 324 674 528 862 1 8.7 0.075

SECONDARY
PRIMARY (HOT) PRIMARY (HOT) SECONDARY ▲T ▲T ▲T
(POOL) HEAD
CODE FLOW HEAD LOSS (POOL) FLOW 50°C 60°C 70°C
LOSS
m3 kPa m3 m3 kW kW kW
SST-36 1.1 6.1 12 5.0 26 30 33
SST-50 2.5 6.8 15 5.0 31 34 39
SST-75 2.7 6.8 18 5.0 34 41 46
SST-95 3.2 7.7 18 5.0 41 50 56

489

V-02
14 TEMPERATURE CONTROL

10 PLATE HEAT
EXCHANGER

• High overall heat transfer coefficient

• Compact design gives maximum surface area


to material volume without compromising
mechanical robustness

• High performance with low hold-up volume


Versatile, modular design

• Plate and gasket materials available to suit


most fluid types

• Easy dismantling for rapid cleaning

A E A E
B S F S B S F S

38.42 STAINLESS
45-50 STEEL
G G
G 1 1/4”

C D
POLYPROPLYENE
37-47
C D

DIMENSION (mm) A B C D E F G H S

PHE100-TI 204 86 490 381 116 39.75 DN32 0 14/12


PHE140-TI 204 86 490 381 116 50.35 DN32 0 14/12
PHE180-TI 204 86 490 381 141 66.25 DN32 0 14/12
PHE240-TI 204 86 490 381 191 92.75 DN32 0 14/12
PHE290-TI 204 86 490 381 191 103.35 DN32 0 14/12
PHE330-TI 204 86 490 381 241 129.85 DN32 0 14/12
PHE370-TI 204 86 490 381 291 140.45 DN32 0 14/12
PHE410-TI 204 86 490 381 291 151.05 DN32 0 14/12
PHE450-TI 312 140 963 690 447 66.5 DN65 185 20/20
PHE500-TI 312 140 963 690 447 87.5 DN65 185 20/20
PHE550-TI 312 140 963 690 447 94.5 DN65 185 20/20
PHE610-TI 312 140 963 690 447 101.5 DN65 185 20/20
PHE670-TI 312 140 963 690 447 115.5 DN65 185 20/20
PHE730-TI 312 140 963 690 447 122.5 DN65 185 20/20
PHE780-TI 312 140 963 690 447 129.5 DN65 185 20/20
PHE820-TI 312 140 963 690 447 136.5 DN65 185 20/20

490 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
SPECIFICATIONS

PROCESS DATA (HOT SIDE) PHE100-TI PHE140-TI PHE180-TI PHE240-TI PHE290-TI PHE330-TI PHE370-TI PHE410-TI

TEMP(IN)°C 90 90 90 90 90 90 90 90
TEMP(OUT)°C 70 70 70 70 70 70 70 70
FLOW RATE (M/H) 4.52 6.20 7.88 10.71 12.70 14.70 16.38 18.33
PRESSURE DROP (KPA) 22.11 25.54 24.50 25.04 26.62 25.55 27.18 29.57

PROCESS DATA (COLD SIDE) PHE100-TI PHE140-TI PHE180-TI PHE240-TI PHE290-TI PHE330-TI PHE370-TI PHE410-TI

TEMP(IN)°C 20 20 20 20 20 20 20 20
TEMP(OUT)°C 35 35 35 35 35 35 35 35
FLOW RATE (M/H) 5.88 8.07 10.26 13.94 16.54 19.13 21.32 23.86
PRESSURE DROP (KPA) 42.19 48.65 46.48 47.13 49.91 47.51 50.36 54.59
DELTA T LOG MEAN (C) 52.46 52.46 52.46 52.46 52.46 52.46 52.46 52.46
HEAT EXCHANGES (KW) 102 140 178 242 287 332 370 414

CONSTRUCTION DATA PHE100-TI PHE140-TI PHE180-TI PHE240-TI PHE290-TI PHE330-TI PHE370-TI PHE410-TI

HEAT TRANSFER AREA (M) 0.624 0.816 1.104 1.584 1.776 2.256 2.448 2.640
OVER SURFACING (%) 121.48 118.57 126.71 133.98 128.42 139.15 136.47 132.69
OVERALL K SERVICE(W/MC) 3114.33 3268.79 3071.85 2910.78 3078.84 2803.80 2879.64 2987.76
FOULING F (MC/KW) 0 0 0 0 0 0 0 0
PLATES THICKNESS (MM) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
OVERALL K CLEAN(W/MC) 6897.51 7144.68 6964.29 6813.72 7032.83 6705.26 6809.54 6952.19
WEIGHT EMPTY (KG) 29 30 32 35 36 39 40 41
WEIGHT FULL (KG) 30.778 32.346 34.698 38.618 40.186 44.106 45.674 47.242
VOLUME HOT SIDE (L) 0.714 0.918 1.224 1.734 1.938 2.448 2.652 2.856
VOLUME COLD SIDE (L) 0.714 0.918 1.224 1.734 1.938 2.448 2.62 2.856
NO. SERIES PASS HOT SIDE 1 1 1 1 1 1 1 1
NO. SERIES PASS COLD SIDE 1 1 1 1 1 1 1 1 14
NO. PARALLEL PASSES HOT SIDE 7 9 12 17 19 24 26 28
NO. PARALLEL PASSES COLD SIDE 7 9 12 17 19 24 26 28

491

V-02
14 TEMPERATURE CONTROL

SPECIFICATIONS

PROCESS DATA (HOT SIDE) PHE450-TI PHE500-TI PHE550-TI PHE610-TI PHE670-TI PHE730-TI PHE780-TI PHE820-TI

TEMP(IN)°C 90 90 90 90 90 90 90 90
TEMP(OUT)°C 70 70 70 70 70 70 70 70
FLOW RATE (M/H) 19.74 22.31 24.17 26.96 29.75 32.54 34.40 36.25
PRESSURE DROP (KPA) 23.28 21.45 21.85 22.51 23.26 22.72 23.21 23.73

PROCESS DATA (COLD SIDE) PHE450-TI PHE500-TI PHE550-TI PHE610-TI PHE670-TI PHE730-TI PHE780-TI PHE820-TI

TEMP(IN)°C 20 20 20 20 20 20 20 20
TEMP(OUT)°C 35 35 35 35 35 35 35 35
FLOW RATE (M/H) 25.70 29.04 31.46 35.06 38.72 42.35 44.77 47.19
PRESSURE DROP (KPA) 50.06 45.73 46.43 47.64 48.88 47.53 48.36 49.24
DELTA T LOG MEAN (C) 52.46 52.46 52.46 52.46 52.46 52.46 52.46 52.46
HEAT EXCHANGES (KW) 446 504 546 609 672 735 777 819

CONSTRUCTION DATA PHE450-TI PHE500-TI PHE550-TI PHE610-TI PHE670-TI PHE730-TI PHE780-TI PHE820-TI

HEAT TRANSFER AREA (M) 2.873 3.887 4.225 4.563 5.239 5.577 5.915 6.253
OVER SURFACING (%) 95.43 114.26 114.95 112.11 116.59 114.10 114.62 115.09
OVERALL K SERVICE(W/MC) 2957.66 2470.38 2462.15 2542.82 2443.82 2510.93 2502.74 2495.42
FOULING F (MC/KW) 0 0 0 0 0 0 0 0
PLATES THICKNESS (MM) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
OVERALL K CLEAN(W/MC) 5780.09 5293.03 5293.03 5393.57 5293.03 5375.97 5371.40 5367.30
WEIGHT EMPTY (KG) 150 155 156 158 161 163 164 166
WEIGHT FULL (KG) 157.85 165.20 167.65 170.10 175.00 177.45 179.90 182.35
VOLUME HOT SIDE (L) 3.825 5.100 5.525 5.950 6.800 7.225 7.650 8.075
VOLUME COLD SIDE (L) 3.825 5.100 5.525 5.950 6.800 7.225 7.650 8.075
NO. SERIES PASS HOT SIDE 1 1 1 1 1 1 1 1
NO. SERIES PASS COLD SIDE 1 1 1 1 1 1 1 1
NO. PARALLEL PASSES HOT SIDE 9 12 13 14 16 17 18 19
NO. PARALLEL PASSES COLD SIDE 9 12 13 14 16 17 18 19

492 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
11 AQUA POOL
DEHUMIDIFIERS
WITH HEATING &
COOLING FUNCTION
AQUA Indoor Environmental Control Systems
provide effective control of damaging moisture
common with indoor pool facilities. They maintain
a delicate balance of humidity control and manage
air and water temperatures for maximum comfort
at the lowest cost. This series uses heat pump
technology to dehumidify the space and recycle • Room hygrostat
the waste energy to heat both the air and pool and thermostat.
water. They are available in many sizes and a
variety of configurations for large indoor pools • Automatically switches
found in hotels, schools, natatoriums, aquatic mode from heat to cool.
centers and water parks.
• Optional digital
BUILT FOR THE CORROSIVE POOL ENVIRONMENT controller with display.
AQUA dehumidifiers have many special design
features to minimize maintenance and extend the
life of the unit. All critical components are located
out of the corrosive air stream, and coils are
constructed from all copper and coated aluminum
fins for long life. AQUA uses full-size air/water
condensers for maximum pool and air heating or
cooling. It utilizes a sophisticated controller that
offers high efficient control strategies for more
efficient intelligent pool operation. All units are
constructed of heavy-gauge steel with side and
roof panels galvanized and epoxy powder coated
to resist corrosion. Panel insulation provides
additional energy efficiency along with sound
control for indoor and outdoor installations.

RECYCLED ENERGY LESSENS THE NEED FOR


FOSSIL FUEL HEATING 14
Indoor pools demand large quantities of heat to
maintain space and water comfort
conditions. Rather than relying on fossil fuel as
the primary heat source, AQUA units utilize waste
heat generated during dehumidification to heat
the space and pool water. AQUA units return much
more energy than they use with average recorded
savings ranging from 40% to 60% over
conventional outside air dilution systems. For
every kilowatt of electrical power used to operate
AQUA system, five kilowatts of heat are delivered
to the natatorium and water. friendly interface
- Self diagnosis

493

V-02
14 TEMPERATURE CONTROL

HIGH EFFICIENCY AND ENVIRONMENTALLY


FRIENDLY
All models use R22 or R417A refrigerant and deliver
excellent performance characteristics. Stage
compressor cycling ensures minimum compressor
operation for any given load for greater efficiency,
and also maintains a high quality environment.
The systems can be configured to return condensate
back to the pool, saving the equivalent of the entire
pool’s volume over one year. For improved air quality,
plasma filters an be added.
- Rugged features delivers unrivaled performance
- Scroll compressor, efficient and quiet operation
- Coated evaporator and reheat condenser coils,
long life
- Titanium tube-in-shell water heat exchanger
- Powder coated cabinet, corrosion resistant
- Controller with user friendly interface
- Self diagnosis

494 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
14

495

V-02
14 TEMPERATURE CONTROL

AD-15 AD-20 AD-25 AD-30 AD-40

POWER SUPPLY V/P/Hz 380-415/3/50


COOLING kW/h 25 33 41 51 65
OUTPUT
HEATING kW/h 30 39 47 60 78

DEHUMIDIFICATION CAPACITY kg/h 17 22 26 33 43

APPLICATION POOL
m2 68 88 104 132 172
SURFACE AREA

RATED AIRFLOW m3@ 300 Pa 4000 5000 6000 7500 9000

QTY. 2 2 2 2 2
TYPE CENTRIFUGAL
BLOWER

STATIC PRESSURE RANGE Pa 100-500 100-500 100-500 100-500 100-850

POWER INPUT kW 1.5 1.5 2.2 2.2 3.5


QTY. 1 1 1 2 2
COMPRES-

TYPE
SOR

POWER INPUT kW 5.5 7 8.5 5.4 7


WATER HEAT EXCHANGER

RATED WORKING PRESSURE MPa 1.2 1.2 1.2 1.2 1.2

MAX. WATER
CONDENSER

°C 40 40 40 40 40
TEMPERATURE

RATED WATER FLOW RATE m3 4.7 6.1 7.2 9.4 12.2

WATER CONN. SIZE mm 32 32 38 50 50

QTY. 1 1 1 1 1
RATED CAPACITY kW 30 39 47 60 78
CONDENSER
AIR COOLED

RATED AIRFLOW m3 10000 12000 15000 20000 24000


NO.OF FANS 1 1 1 2 2
FAN MOTOR
kW 0.82 0.82 1.65 0.82 0.82
POWER INPUT
mm 706 1450 1450 1450 1800
OUTDOOR
mm 686 705 705 705 705
DIMENSIONS

CONDENSER
mm 940 1065 1065 1065 1065
mm 3000 3600 3600 3800 4200
INDOOR MAIN UNIT mm 1300 1520 1570 1670 1670
mm 1200 1200 1260 1360 1450

INDOOR MAIN UNIT WEIGHT kg 500 800 900 1200 1500

PACKING 1 1 1 1 1

496 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
AD-50 AD-60 AD-80 AD-100 AD-120 AD-160

380-415/3/50
82 97 131 163 192 241
106 128 170 214 243 280

51 62 84 102 122 160

204 248 336 408 488 640

11000 13000 16600 21000 25000 32000

2 2 2 2 2 2
CENTRIFUGAL

100-850 100-850 100-850 100-850 100-850 100-850

4 5.5 6 7 7.5 11
2 2 2 or 4 2 or 4 2 or 4 2 or 4

8.5 11 7 or 13 8.5 or 16.5 11 or 22 13 or 25

1.2 1.2 1.2 1.2 1.2 1.2

40 40 40 40 40 40

14.5 18.8 24.6 30.6 37.5 48

63 63 75 75 90 100

1 1 2 2 2 2
96 118 150 184 223 278
30000 40000 48000 60000 80000 90000
2 2 4 4 4 4

0.82 0.82 0.82 0.82 1.1 1.1


14
1850 2110 1800 1850 2110 2500
1000 1100 1000 1000 1100 1200
1320 1350 1320 1320 1350 1350
4600 4900 5400 5800 6600 7000
1930 2160 2200 2200 2150 2200
1520 1690 1840 2150 2200 2500

1650 1850 2200 2500 2700 3300

1 1 1 1 1 1

497

V-02
14 TEMPERATURE CONTROL

12 WATER TO WATER
POOL HEAT PUMP

• Standard type (Heating capacity: 13.7kw~171kw)

• Touch design LCD control display and control signal


are easier to be transferred to control system
with BMS.

• Clock & Timing on/off function

• Efficiency

• Titanium heat exchanger

• Quiet Operation

• Environmentally Friendly

• Quality

WATER TO WATER HEAT PUMP – R410A


WN040SV WN050SV WN060SV WN070SV WN100SV

Power supply V/PH/Hz 380-420/50/3


Max Power Input kW 4.6 5.6 6.7 7.8 12.1
Sourcing water inlet Temp: 20°C, User’s side water inlet/outlet @ 26°C/28°C
Heating capacity kW 17.0 21.0 25.0 29.0 45.0
Power input kW 3.0 3.8 4.5 5.2 8.0
COP W/W 5.6 5.6 5.6 5.6 5.6
Sourcing water inlet Temp: 15°C, User’s side water inlet/outlet @ 26°C/28°C
Heating capacity kW 14.5 17.9 21.3 24.7 38.3
Power input kW 3.2 4.0 4.7 5.5 8.3
COP W/W 4.53 4.51 4.52 4.48 4.60
Sourcing water inlet Temp: 10°C, User’s side water inlet/outlet @ 35°C/40°C
Heating capacity kW 10.9 13.6 18.2 21.0 27.1
Power input kW 2.7 3.4 4.6 5.3 6.7
COP W/W 3.98 3.95 3.96 3.96 4.03
Sourcing water inlet Temp: 30°C, User’s side water inlet/outlet @ 30°C/28°C
Cooling capacity 9 11 15 17 22
Power input 2.7 3.4 4.5 5.3 6.6
EER 3.32 3.30 3.31 3.28 3.37
Rated running current A 5.4 6.70 7.98 9.26 14.36
Max. running current A 8 10 12 14 22
Water temp. setting (heating) °C 15~40
Water temp. setting (cooling) °C 15~40
Max outlet water temp. °C 40
Water connection Inch G1 G1 G1 G1-1/2 G1-1/2
Sound pressure level db(A) 41 42 42 43 44
Net weight kg 100 120 120 185 250
Net dimensions (L x W x H) mm 900/760/860 900/760/860 900/760/860 900/760/860 1320/840/1130

498 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
DIAGRAM

WN120SV WN150SV WN200SV WN250SV WN300SV WN400SV WN500SV


380-420/50/3
14.7 17.4 22.5 28.1 33.5 45 56.3
Sourcing water inlet Temp: 20°C, User’s side water inlet/outlet @ 26°C/28°C
55.0 65 84 105 125 168 210
9.8 11.6 15.0 18.8 22.3 30.0 37.5
5.6 5.6 5.6 5.6 5.6 5.6 5.6
Sourcing water inlet Temp: 15°C, User’s side water inlet/outlet @ 26°C/28°C
46.8 55.3 71.4 89.3 106.3 142.8 178.5
10.2 12.2 15.9 19.6 23.6 32.1 39.4
4.56 4.53 4.48 4.56 4.49 4.45 4.53
Sourcing water inlet Temp: 0°C, User’s side water inlet/outlet @ 35°C/40°C
35.4 40 53 71 83 106 136
8.9 10.1 13.5 17.7 21.0 27.2 34.1
4.00 3.98 3.93 4.00 3.94 3.91 3.98 14
Sourcing water inlet Temp: 30°C, User’s side water inlet/outlet @ 30°C/28°C
29 33 44 58 68 87 112
8.7 9.9 13.3 17.4 20.6 26.8 33.6
3.34 3.32 3.28 3.34 3.29 3.26 3.32
17.56 20.7 26.8 33.5 39.9 53.6 67.0
26 31 40 50 60 80 101
15~40
15~40
40
G1-1/2 G2 G2 Dn90 Flange Dn90 Flange Dn110 Flange Dn110 Flange
44 45 49 55 55 56 56
280 360 500 610 720 990 990
1320/840/1130 1320/840/1130 1750/1120/1000 1750/1120/1000 2000/1120/1000 2300/1120/1000 2600/1120/1000

499

V-02
14 TEMPERATURE CONTROL

13 AIR COOLED
WATER CHILLER

• Touch design LCD control display and control


signal are easier to be transferred to control
system with BMS.
• Clock& Timing on/off function
• Phase monitor: Protects the compressor in case
of phase loss or inversion
• High/low pressure protection available
• cooled water temperature

AIR COOLED WATER CHILLER

CH-0110 CH-0120 CH-0130


Power supply V/PH/Hz 220/1/50
kW 5.3 7.0 8.8
Cooling capacity
BTU/h 18084 23884 30026
Cooling: A35/24°C Chilled water production T=20°C Us Gal/h 60 79 100
W/45/25°C Power input kW 1.8 2.5 3.1
Current A 8.3 11.4 14.3
EER W/W 2.90 2.80 2.80
kW 4.5 6.0 7.5
Cooling capacity
BTU/h 15371 20301 25522
Cooling: A35/24°C Chilled water production T=20°C Us Gal/h 51 68 85
W/45/25°C Power input kW 22 3.0 3.7
Current A 9.8 13.4 16.9
EER W/W 2.09 2.02 2.02
kW 4.3 5.7 7.2
Cooling capacity
BTU/h 14829 19585 24621
Cooling: A35/24°C Chilled water production T=20°C Us Gal/h 49 65 82
W/45/25°C Power input kW 2.2 3.0 3.8
Current A 10.0 13.6 17.1
EER W/W 1.98 1.91 1.91
kW 6.4 8.4 10.6
Cooling capacity
BTU/h 21700 28661 36031
Cooling: A35/24°C Chilled water production T=20°C Us Gal/h 36 48 60
W/45/25°C Power input kW 1.5 2.0 2.6
Current A 6.8 9.3 11.7
EER W/W 4.2 4.1 4.1
Power input kW 2.7 3.8 4.7
MAX
Current A 12.5 17.0 21.4
Water outlet temp. range °C 5-40 5-40 5-40
OPERATING
Ambient temp. range °C 0-53 0-53 0-53
Compressor type Rotary Rotary Scroll
KEY
Noise db(A) 52 52 55
Type Titanium /PVC Titanium /PVC Titanium /PVC
Standard water flow (min) Us GPM 2.5 3.3 4.2
HEAT
Standard water flow (mix) Us GPM 8.7 11.5 14.5
EXCHANGER
Water pressure drop(max) kPa 6 7 8
Water connection mm 40 40 40
FAN Fan position Horizontal Horizontal Verticle
DIMENSIONS Net mm
(W x H x D) Shipping mm
WEIGHT kg 60/66 58/64 80/87

500 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
CH-0140 CH-0150 CH-0160 CH-0170 CH-0180
380/3/50
10.5 14.2 17.5 28 34
35826 48450 59710 95536 116008
119 161 199 318 386
3.8 5.1 6.3 10.0 12.1
6.7 9.1 11.2 17.9 21.7
2.80 2.78 2.80 2.80 2.80
8.9 12.1 14.9 23.8 28.9
30452 41183 50754 81206 98607
101 137 169 270 328
4.4 6.0 7.4 11.80 14.3
7.9 10.8 13.2 21.1 25.6
2.02 2.02 2.02 2.02 2.02
8.6 11.6 14.4 23.0 27.9
29377 39729 48962 78340 95127
98 132 163 261 316
4.5 6.1 7.5 12.0 14.6
8.0 11.0 13.4 21.5 26.0
1.91 1.90 1.91 1.91 1.91
12.6 17.0 21.0 33.6 40.8
42991 58140 71652 114643 139210
72 97 119 191 232
3.1 4.2 5.1 8.2 9.9
5.5 7.5 9.1 14.6 17.8
4.1 4.1 4.1 4.1 4.1
5.6 7.7 9.4 15.0 18.2
10.1 13.7 16.8 26.8 32.6
5-40 5-40 5-40 5-40 5-40
0-53 0-53 0-53 0-53 0-53
Scroll Scroll Scroll Scroll Scroll
55 58 58 59 59
Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC Titanium /PVC
5.0 6.7 8.3 13.3 16.1
17.3 23.4 28.8 46.1 56.0
10 11 12 15 15
40 50 50 63 63
Verticle Verticle Verticle Verticle Verticle

14
95/97 95/102 102/112 200/225 230/258

501

V-02
14 TEMPERATURE CONTROL

14 INDOOR POOL
DEHUMIDIFIER

FEATURES
• Portable Dehumidifiers type & Wall mounted

• Absorbing clammy air in house and transferring

• provide you a cool and comfortable environment

• Epoxy fin air exchanger (wall mounted)

• Clock & Timing on/off function(wall mounted )

• Efficiency
PORTABLE
• Fashionable appearance

• Quiet operation

• Environmentally friendly

• Clear Windows, Dry Walls: No more foggy


windows or condensation on walls in the pool
room with AQUA dehumidifiers preserve the
construction integrity and gives a pleasant
feeling to the room occupants.

• Simple Installation: Can be free standing or


remote. It is also duct ready, the control can be
easily made in a 220 volts wiring.

• Quality Construction & Reliability: AQUA


dehumidifier comes in white coated antihumidity WALL MOUNTED
paint or in stainless steel body, Digital LCD
controller & gas pressure gauge. The unit is
covered under a 5 year warrantee.

• Low Electrical Cost: AQUA dehumidifier utilizes a


refrigeration system that requires a smaller
electrical load.

• Humidity Control: Stabilize room conditions


through dehumidification, this reduces the
maintenance cost of the room and gives a very
pleasant environment to the pool room.

• Indoor Pool Room Heating: Recovering energy


from the dehumidification process will often
heat an entire pool room for the cost of
operating the dehumidifier alone.

• Indoor Pool Room Cooling: An optional remote


condenser will allow the DCA system to cool the
pool room during the warm months.

• Easy to Maintain: The AQUA dehumidifier system


is a closed loop system with nothing to oil or
lubricate. Simple return air filter maintenance is
all that is needed.

502 AQUA MIDDLE EAST / POOL, SPA, FOUNTAIN EQUIPMENT & ACCESSORIES CATALOGUE 2020

V-02
INDOOR POOL DEHUMIDIFIER

INDOOR POOL DEHUMIDIFIER WALL MOUNTED PORTABLE

DW02 DW03 DW04 DM02 DM03 DM04 DM06


Power supply 220-240V-/50HZ
Ambient Temp. 30°C, 80% relative humidity
Rated capacity l/h 2.3 3.2 4.5 2.5 3.2 4.5 6
Dehumidification Capacity per
l 55.2 76.8 108 60 76.8 108 144
day
Recommended pool Area m2 42 60 84 42 60 84 112
Air Volume m3/h 450 600 750 450 600 750 900
Noise level db(A) 44 46 50 44 46 50 50
Rated Power Input kW 0.93 1.14 1.73 0.93 1.14 1.73 2.14
Rated Running Current A 4.1 5 7.5 4.1 5 7.5 9.7
Max. Power Input kW 1.02 1.25 1.9 1.40 1.71 2.60 3.21
Max. Running Current A 4.3 5.4 8.2 6.3 7.8 11.8 14.6
Relative Humidity %RH 40-100
Temperature °C 10-36
Dimensions (L /W/H) mm 868/260/720 868/260/720 1268/260/720 400/500/720 400/500/720 480/580/1008 480/580/1008

Net Weight kg 46 51 64 45 50 63 130


Condensation Pipe Diameter mm 16

Note: We reserve the rights to modify the above specifications without notice,
pleasecontact us for updated information.