The HPE FlexFabric 5940 Switch Series provides high-performance, low-latency 10GbE and 40GbE top-of-rack switching for large enterprise and medium-sized enterprise data centers. It offers high port density, flexible modular designs, advanced QoS, virtualization support, and high availability features like redundant power and fans. The switches are optimized for virtualized environments, Ethernet and storage convergence, and low-latency server connectivity requirements.

Uploaded by

razor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
306 views27 pages

HPE Networking Comware Switch Series 5940-c05158726

The HPE FlexFabric 5940 Switch Series provides high-performance, low-latency 10GbE and 40GbE top-of-rack switching for large enterprise and medium-sized enterprise data centers. It offers high port density, flexible modular designs, advanced QoS, virtualization support, and high availability features like redundant power and fans. The switches are optimized for virtualized environments, Ethernet and storage convergence, and low-latency server connectivity requirements.

Uploaded by

razor
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 27

QuickSpecs HPE FlexFabric 5940 Switch Series

Overview

HPE FlexFabric 5940 Switch Series


The HPE FlexFabric 5940 Switch Series is a family of high performance and low-latency 10GbE, 40GbE top-of-rack (ToR) data
center switches. The switch series include also 100G uplink technology and also a 2-slot and 4-slot modular form factor providing
ultimate flexibility for an ever-changing Data Center requirements. This entire series is part of the Hewlett Packard Enterprise
FlexFabric data center solution, which is a cornerstone of the FlexNetwork architecture.

The FlexFabric 5940 Switch Series is ideally suited for deployment at the aggregation or server access layer of large enterprise data
centers, or at the core layer of medium-sized enterprises.

With the increase pace of deploying virtualized applications, adopting software-defined networking, and the server-to-server traffic,
many data centers now require spine and ToR switch innovations that will meet their requirements. The HPE FlexFabric 5940 is
optimized to meet the increasing requirements for higher-performance server connectivity, convergence of Ethernet and storage
traffic, the capability to handle virtual environments, and low-latency.

HPE FlexFabric 5940 Switch Series

Models
HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch JH390A
HPE FlexFabric 5940 48XGT 6QSFP28 Switch JH391A
Key features
• VXLAN L2 and L3 and EVPN support for virtualized environments
• OpenFlow support for investment protection and SDN environments
• High-density 10GbE, 40GbE with 40G or 100G uplink and modular for spine-and–leaf deployments
• Unify management of virtual and physical network with VEPA and IMC
• Data center convergence and resiliency with SPB, ISSU, DCB, FC/FCoE, IRF, and TRILL

Page 1
QuickSpecs HPE FlexFabric 5940 Switch Series

Standard Features

Features and benefits


Data center optimized
• Flexible high port density
5940 switch enables customers to scale their server-edge 10/40/100 GbE ToR deployments to new heights with high-
density 48 x 10 GbE ports with 6 ports of 40G, 48 x 10 GbE ports with 6 ports of 100G and 32 x 40 GbE delivered in a
1RU design; the 5940 32 ports of 40G switch can also be configured as a 72 x 10 GbE port device by using a 40G-to-10
GbE splitter cable that turns each 40 GbE port into four 10-GbE ports. The 48 ports models comes in SFP+ or BASE-T
• High-performance switching
Cut-through and nonblocking architecture delivers low latency (~1 microsecond for 10GbE) for very demanding enterprise
applications; the switch delivers high-performance switching capacity and wire-speed packet forwarding
• Higher scalability
Hewlett Packard Enterprise Intelligent Resilient Fabric (IRF) technology simplifies the architecture of server access
networks; up to nine HPE 5940 switches can be combined to deliver unmatched scalability of virtualized access layer
switches and flatter two-tier networks using IRF, which reduces cost and complexity
• Advanced modular operating system
Comware v7 software's modular design and multiple processes bring native high stability, independent process monitoring,
and restart; the OS also allows individual software modules to be upgraded for higher availability and supports enhanced
serviceability functions like hitless software upgrades
• Reversible airflow
Enhanced for data center hot-cold aisle deployment with reversible airflow—for either front-to-back or back-to-front airflow
• Redundant fans and power supplies
Internal redundant and hot-pluggable power supplies and dual fan trays enhance reliability and availability
• Lower OPEX and greener data center
Provide reversible airflow and advanced chassis power management
• Data Center Bridging (DCB) protocols
Provides support for IEEE 802.1Qbb Priority Flow Control (PFC), Data Center Bridging Exchange (DCBX), IEEE 802.1Qaz
Enhanced Transmission Selection (ETS), Explicit Congestion Notification (ECN) for converged FCoE, iSCSI and RoCE
environments
• FCoE support
Provides support for T11 standards-compliant FC-BB-5 Fibre Channel over Ethernet (FCoE), including FCoE initialization
protocol (FIP), FCP, Fiber Channel enhanced port types VE, TE and VF, NPV, NPIV, fabric name server, RSCN, login services,
and name-server zoning, per-VSAN fabric services, FSPF, standard zoning and fiber channel ping
• Jumbo frames
With frame sizes of up to 10,000 bytes on Gigabit Ethernet and 10-Gigabit ports, allows high-performance remote backup
and disaster-recovery services to be enabled
• VXLAN hardware support
VXLAN Layer 2 and Layer 3 gateway support for up to 4k tunnels
• Dynamic VXLAN configuration
OVSDB & ML2 support for dynamic VXLAN configuration
• EVPN
Control plane protocol for VXLAN based on industry standards. It enables Layer-2 and Layer-3 control-plane learning of
end-host reachability information, enabling organizations to scale their VXLAN infrastructure better. Integration with
Openstack Neutron plugin for overlay automation/orchestration
Quality of Service (QoS)
• Powerful QoS features
− Flexible queue scheduling: Including Strict Priority (SP), WRR, WDRR, WFQ, SP+WRR, SP+WDRR, SP+WFQ,
Configurable Buffer, Time range, Queue Shaping, CAR with 8kbps granularity.
− Packet filtering and remarking: Packet filtering at L2 (Layer 2) through L4 (Layer 4); flow classification based on
source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address,
port, protocol, and VLAN.
Provides no blocking, lossless Clos architecture with VOQs and large buffers with the flexibility and scalability for
future growth

Page 2
QuickSpecs HPE FlexFabric 5940 Switch Series

Standard Features

Manageability
• Full-featured console
Provides complete control of the switch with a familiar CLI
• Troubleshooting
− Ingress and egress port monitoring: Enable network problem solving
− Traceroute and ping: Enable testing of network connectivity
• Multiple configuration files
Allow multiple configuration files to be stored to a flash image
• SNMP v1, v2c and v3
Facilitate centralized discovery, monitoring, and secure management of networking devices
• Out-of-band interface
Isolates management traffic from user data plane traffic for complete isolation and total reachability, no matter what
happens in the data plane
• Remote configuration and management
Delivered through a secure command-line interface (CLI) over Telnet and SSH; role-cased access control (RBAC) provides
multiple levels of access; configuration rollback and multiple configurations on the flash provide ease of operation; remote
visibility is provided with sFlow and SNMP v1/v2/v3, and is fully supported in HPE Intelligent Management Center (IMC)
• ISSU and hot patching
In Services Software Upgrade (ISSU) provides hitless software upgrades and hitless patching of the modular operating
system
• Autoconfiguration
Provides automatic configuration via DHCP autoconfiguration
• NTP, SNTP
Synchronizes timekeeping among distributed time servers and clients; support for network time protocol (NTP), secure
network time protocol (SNTP)
Resiliency and high availability
• IRF technology
Enables an Hewlett Packard Enterprise FlexFabric to deliver resilient, scalable, and secured data center networks for
physical and virtualized environments; groups up to nine HPE 5940 switches in an IRF configuration, allowing them to be
configured and managed as a single switch with a single IP address; simplifies ToR deployment and management, reducing
data center deployment and operating expenses
• IEEE 802.1w Rapid Convergence Spanning Tree Protocol
Increases network uptime through faster recovery from failed links
• IEEE 802.1s Multiple Spanning Tree
Provides high link availability in multiple VLAN environments by allowing multiple spanning trees
• Virtual Router Redundancy Protocol (VRRP)
Allows groups of two routers to back each other up dynamically to create highly available routed environments
• Hitless patch upgrades
Allows patches and new service features to be installed without restarting the equipment, increasing network uptime and
facilitating maintenance
• Ultrafast protocol convergence (< 50 ms) with standard-based failure detection—Bidirectional Forwarding
Detection (BFD)
Enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and IRF
• Device Link Detection Protocol (DLDP)
Monitors link connectivity and shuts down ports at both ends if unidirectional traffic is detected, preventing loops in STP-
based networks
• Graceful restart
Allows routers to indicate to others their capability to maintain a routing table during a temporary shutdown and
significantly reduces convergence times upon recovery; supports OSPF, BGP, and IS-IS
Additional information
• Green IT and power
Improves energy efficiency through the use of the latest advances in silicon development; shuts off unused ports and
utilizes variable-speed fans, reducing energy costs
Page 3
QuickSpecs HPE FlexFabric 5940 Switch Series

Standard Features

Layer 3 routing
• Virtual Router Redundancy Protocol (VRRP) and VRRP Extended
Allow quick failover of router ports
• Policy-based routing
Makes routing decisions based on policies set by the network administrator
• Equal-Cost Multipath (ECMP)
Enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth
• Layer 3 IPv4 routing
Provides routing of IPv4 at media speed; supports static routes, RIP and RIPv2, OSPF, BGP, and IS-IS
• Open shortest path first (OSPF)
Delivers faster convergence; uses this link-state routing Interior Gateway Protocol (IGP), which supports ECMP, NSSA, and
MD5 authentication for increased security and graceful restart for faster failure recovery
• Border Gateway Protocol 4 (BGP-4)
Delivers an implementation of the Exterior Gateway Protocol (EGP) utilizing path vectors; uses TCP for enhanced reliability
for the route discovery process; reduces bandwidth consumption by advertising only incremental updates; supports
extensive policies for increased flexibility; scales to very large networks
• Intermediate system to intermediate system (IS-IS)
Uses a path vector Interior Gateway Protocol (IGP), which is defined by the ISO organization for IS-IS routing and extended
by IETF RFC 1195 to operate in both TCP/IP and the OSI reference model (Integrated IS-IS)
• Static IPv6 routing
Provides simple manually configured IPv6 routing
• Dual IP stack
Maintains separate stacks for IPv4 and IPv6 to ease the transition from an IPv4-only network to an IPv6-only network
design
• Routing Information Protocol next generation (RIPng)
Extends RIPv2 to support IPv6 addressing
• OSPFv3
Provides OSPF support for IPv6
• BGP+
Extends BGP-4 to support Multiprotocol BGP (MBGP), including support for IPv6 addressing
• IS-IS for IPv6
Extends IS-IS to support IPv6 addressing
• IPv6 tunneling
Allows IPv6 packets to traverse IPv4-only networks by encapsulating the IPv6 packet into a standard IPv4 packet; supports
manually configured, 6to4, and Intra-Site Automatic Tunnel Addressing Protocol (ISATAP) tunnels; is an important element
for the transition from IPv4 to IPv6
• Policy routing
Allows custom filters for increased performance and security; supports ACLs, IP prefix, AS paths, community lists, and
aggregate policies
• Bidirectional Forwarding Detection (BFD)
Enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and IRF
• Multicast Routing PIM Dense and Sparse modes
Provides robust support of multicast protocols
• Layer 3 IPv6 routing
Provides routing of IPv6 at media speed; supports static routing, RIPng, OSPFv3, BGP4+ for IPv6, and IS-ISv6
Layer 2 switching
• MAC-based VLAN
Provides granular control and security; uses RADIUS to map a MAC address/user to specific VLANs
• Address Resolution Protocol (ARP)
Supports static, dynamic, and reverse ARP and ARP proxy
• IEEE 802.3x Flow Control
Provides intelligent congestion management via PAUSE frames

Page 4
QuickSpecs HPE FlexFabric 5940 Switch Series

Standard Features

• Ethernet Link Aggregation


Provides IEEE 802.3ad Link Aggregation of up to 128 groups of 32 ports; support for LACP, LACP Local Forwarding First,
and LACP Short-time provides a fast, resilient environment that is ideal for the data center
• Spanning Tree Protocol (STP)
Supports STP (IEEE 802.1D), Rapid STP (RSTP, IEEE 802.1w), and Multiple STP (MSTP, IEEE 802.1s)
• VLAN support
Provides support for 4,096 VLANs based on port, MAC address, IPv4 subnet, protocol, and guest VLAN; supports VLAN
mapping
• IGMP support
Provides support for IGMP Snooping, Fast-Leave, and Group-Policy; IPv6 IGMP Snooping provides Layer 2 optimization of
multicast traffic
• DHCP support at Layer 2
Provides full DHCP Snooping support for DHCP Snooping Option 82, DHCP Relay Option 82, DHCP Snooping trust, and
DHCP Snooping item backup
Layer 3 services
• Address Resolution Protocol (ARP)
Determines the MAC address of another IP host in the same subnet; supports static ARPs; gratuitous ARP allows detection
of duplicate IP addresses; proxy ARP allows normal ARP operation between subnets or when subnets are separated by a
Layer 2 network
• Dynamic Host Configuration Protocol (DHCP)
Simplifies the management of large IP networks and supports client and server; DHCP Relay enables DHCP operation
across subnets
• Operations, administration and maintenance (OAM) support
Provides support for Connectivity Fault Management (IEEE 802.1AG) and Ethernet in the First Mile (IEEE 802.3AH);
provides additional monitoring that can be used for fast fault detection and recovery
Security
• Access control lists (ACLs)
Provide IP Layer 3 filtering based on source/destination IP address/subnet and source/destination TCP/UDP port number
• RADIUS/TACACS+
Eases switch management security administration by using a password authentication server
• Secure shell
Encrypts all transmitted data for secure remote CLI access over IP networks
• IEEE 802.1X and RADIUS network logins
Controls port-based access for authentication and accountability
• Port security
Allows access only to specified MAC addresses, which can be learned or specified by the administrator
Convergence
• LLDP-MED (Media Endpoint Discovery)
Defines a standard extension of LLDP that stores values for parameters such as QoS and VLAN to configure automatically
network devices such as IP phones
Management
• USB support
− File copy: Allows users to copy switch files to and from a USB flash drive
• Port mirroring
Enables traffic on a port to be simultaneously sent to a network analyzer for monitoring
• Remote configuration and management
Is available through a CLI
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
Advertises and receives management information from adjacent devices on a network, facilitating easy mapping by network
management applications
Page 5
QuickSpecs HPE FlexFabric 5940 Switch Series

Standard Features

• sFlow (RFC 3176)


Provides scalable ASIC-based wirespeed network monitoring and accounting with no impact on network performance; this
allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and
real-time network monitoring purposes
• Command authorization
Leverages RADIUS to link a custom list of CLI commands to an individual network administrator's login; an audit trail
documents activity
• Dual flash images
Provides independent primary and secondary operating system files for backup while upgrading
• Command-line interface (CLI)
Provides a secure, easy-to-use CLI for configuring the module via SSH or a switch console; provides direct real-time session
visibility
• Logging
Provides local and remote logging of events via SNMP (v2c and v3) and syslog; provides log throttling and log filtering to
reduce the number of log events generated
• Management interface control
Provides management access through a modem port and terminal interface, as well as in-band and out-of-band Ethernet
ports; provides access through terminal interface, Telnet, or secure shell (SSH)
• Industry-standard CLI with a hierarchical structure
Reduces training time and expenses, and increases productivity in multivendor installations
• Management security
Restricts access to critical configuration commands; offers multiple privilege levels with password protection; ACLs provide
Telnet and SNMP access; local and remote syslog capabilities allow logging of all access
• Information center
Provides a central repository for system and network information; aggregates all logs, traps, and debugging information
generated by the system and maintains them in order of severity; outputs the network information to multiple channels
based on user-defined rules
• Network management
HPE IMC centrally configures, updates, monitors, and troubleshoots
• Remote intelligent mirroring
Mirrors ingress/egress ACL-selected traffic from a switch port or VLAN to a local or remote switch port anywhere on the
network
Warranty and support
• 1-year warranty
See http://www.hpe.com/networking/warrantysummary for warranty and support information included with your
product purchase.
• Software releases
To find software for your product, refer to http://www.hpe.com/networking/support; for details on the software releases
available with your product purchase, refer to http://www.hpe.com/networking/warrantysummary

Page 6
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

Build To Order: BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or Rack-Shippable
solution.
Standard Switch Enclosures
Rule # Description SKU
1, 3, 5, 7 HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch JH390A
• 48 SFP+ ports (min=0 \ max=48)
• 6 QSFP28 ports (min=0 \ max=6)
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
• 1U - Height
3, 5, 7, 8 HPE FlexFabric 5940 48XGT 6QSFP28 Switch JH391A
• 48 1/10BaseT GbE ports (min=0 \ max=48)
• 6 QSFP28 ports (min=0 \ max=6)
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
• 1U - Height
Configuration Rules
1 The following SFP+ Transceivers install into this Switch:
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
HPE FlexNetwork X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable JC784C
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
2 The following QSFP+ Transceivers install into this switch:
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
Page 7
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

Rule # Description SKU


3 The following QSFP28 Transceivers install into this switch:
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
4 If this switch is configured for an NFV solution(Q0F04A - HPE NFV System V1.3 3Par Storage
Block), default no less than the quantities specified below for the following components:
Qty 2 - JG553A (min 2)
Qty 2 - JC680A (min 2)
Qty 4 - JD092B (min 4)
Qty 1 - JG326A (min 1)
5 The following SFP Transceivers install into this Switch:
HPE X120 1G SFP RJ45 T Transceiver JD089B
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
6 Localization (Wall Power Cord) required on orders without #B2B, #B2C (PDU Power Cord) . (See
Localization Menu)
NOTE: When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be the Defaulted Power
Cable option on the Switches/Routers.
The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if switch
7
is CTO) - if applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
8 The following 100G Transceivers install into this Switch's QSFP28 Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A
NOTE: Drop down under power supply should offer the following options and results:
Switch/Router to PDU Power Cord - #B2B in NA, Mexico, Taiwan, and Japan or #B2C ROW. (Watson
Default B2B or B2C for Rack Level CTO)
Switch/Router/Power Supply to Wall Power Cord - Localized Option (Watson Default for BTO and
Box Level CTO)

Page 8
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

High Volt Switch/Router/Power Supply to Wall Power Cord - #B2E Option. (Offered only in North
America, Mexico, Taiwan, and Japan)
No Power Cord - #AC3 Option
OCA Only Model Selection Form -
HPE Offering > DataCenter Networking > FlexFabric Switches - Access:
5940 DCN Switch Series

Rack Level Integration CTO Models


CTO Switch Chassis
Rule # Description SKU
1, 3, 4, 6, 7 HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch JH390A
• 48 SFP+ ports (min=0 \ max=48)
• 6 QSFP28 ports (min=0 \ max=6)
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
• 1U - Height
3, 4, 6, 7 HPE FlexFabric 5940 48XGT 6QSFP28 Switch JH391A
• 48 1/10BaseT GbE ports (min=0 \ max=48)
• 6 QSFP28 ports (min=0 \ max=6)
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
• 1U – Height
Configuration Rules
Rule # Description SKU
1 The following SFP+ Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
HPE FlexNetwork X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable JC784C
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
2 The following QSFP+ Transceivers install into this switch:
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
Page 9
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
Rule # Description SKU
3 The following QSFP28 Transceivers install into this switch:
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
4 If HPE CTO Switch Chassis is selected for Rack Level Integration, Then the Switch needs to integrate
(with #0D1) to the Rack.
5 If this switch is configured for an NFV solution(Q0F04A - HPE NFV System V1.3 3Par Storage
Block), default no less than the quantities specified below for the following components:
Qty 2 - JG553A (min 2)
Qty 2 - JC680A (min 2)
Qty 4 - JD092B (min 4)
Qty 1 - JG326A (min 1)
6 The following SFP Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X120 1G SFP RJ45 T Transceiver JD089B
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
7 The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
8 The following 100G Transceivers install into this Switch's QSFP28 Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A

Page 10
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

NOTE: Drop down under power supply should offer the following options and results:
Switch/Router to PDU Power Cord - #B2B in NA, Mexico, Taiwan, and Japan or #B2C ROW. (Watson
Default B2B or B2C for Rack Level CTO)
Switch/Router/Power Supply to Wall Power Cord - Localized Option (Watson Default for BTO and
Box Level CTO)
High Volt Switch/Router/Power Supply to Wall Power Cord - #B2E Option. (Offered only in North
America, Mexico, Taiwan, and Japan)
No Power Cord - #AC3 Option
Clic UNB - If an option is ordered with #0D1/#B01, then the switch must have #0D1 option.
Enter the following menu selections as integrated to the CTO Model X server above if order is factory built.
Switch Options
Rule # Description SKU
System (std 0 // max 2) User Selection (min 0 // max 2)
6, 10 HPE FlexFabric 5950 8-port QSFP28 MACsec Module JH957A
• 8 40G QSFP+ ports (min=0 \ max=8)
6, 8, 9, 10 HPE 5940 2-port QSFP+ and 2-port QSFP28 Module JH409A
• 2 QSFP+ ports (min=0 \ max=2)
• 2 QSFP28 ports (min=0 \ max=2)
1, 6, 7, 8, 14, HPE 5930 24-port SFP+ and 2-port QSFP+ Module JH180A
15
• 24 SFP+ ports (min=0 \ max=24)
• 2 QSFP+ ports (min=0 \ max=2)
6, 7, 8, 11, HPE 5930 24-port SFP+ and 2-port QSFP+ with MACsec Module JH181A
14, 15
• 24 SFP+ ports (min=0 \ max=24)
• 2 QSFP+ ports (min=0 \ max=2)
6, 8 HPE 5930 24-port 10GBASE-T and 2-port QSFP+ with MACsec Module JH182A
• 24 1/10GBase-T ports
• 2 QSFP+ ports (min=0 \ max=2)
2, 8 HPE 5930 8-port QSFP+ Module JH183A
• 8 QSFP+ ports (min=0 \ max=8)
1, 2, 8, 12, HPE 5930 24-port Converged Port and 2-port QSFP+ Module JH184A
13, 14, 15
• 24 Converged SFP+/FC ports (min=0 \ max=24)
• 2 QSFP+ ports (min=0 \ max=2)
Configuration Rules
Rule # Description SKU
1 The following SFP+ Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
Page 11
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

HPE FlexNetwork X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable JC784C
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
Configuration Rules
Rule # Description SKU
2 The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A
6 The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
7 The following 10G Transceivers install into this Module's SFP+ Ports: (Use #0D1 or #B01 if switch is
CTO) - if applicable
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
8 The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
9 The following QSFP28 Transceivers install into this Module's QSFP28 Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A

Page 12
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A


HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
Configuration Rules
Rule # Description SKU
10 The following 40G Cables install into this Module's QSFP+ Ports ONLY: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A
11 The following SFP+ Transceivers install into this Module's SFP+ Ports: (Use #0D1 or #B01 if switch
is CTO) - if applicable
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
HPE FlexNetwork X240 10G SFP+ SFP+ 7m Direct Attach Copper Cable JC784C
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
12 The following FC Transceivers install into this Module's SFP+/FC Ports: (Use #0D1 or BTO if switch
is CTO) - if applicable
HPE StoreFabric 16Gb FC/10GbE 100m SR SFP+ Transceiver H6Z42A
HPE 8Gb Short Wave Fibre Channel SFP+ 1 Pack AJ718A
13 Fibre channel support is 8Gb/4Gb/2Gb on any of the 24 converged ports of the JH184A Module.
Note that a maximum of 8Gb FC is supported regardless of the FC optics used.
14 The following SFP Transceivers install into this Module: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X120 1G SFP RJ45 T Transceiver JD089B
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
HPE X120 1G SFP LC LH100 Transceiver JD103A
15 The following SFP+ Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X130 10G SFP+ LC LH 80km Transceiver JG915A
HPE X130 10G SFP+ LC ER 40km Transceiver JG234A

Page 13
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

Transceivers
Remarks Description SKU
SFP Transceivers
HPE X120 1G SFP RJ45 T Transceiver JD089B
HPE X120 1G SFP LC SX Transceiver JD118B
HPE X120 1G SFP LC LX Transceiver JD119B
HPE X120 1G SFP LC LH100 Transceiver JD103A
NOTE: The SFP Transceivers (JD061A, JD062A) are only supported in ports 1-8 for the JH390A Switch
SFP+ Transceivers
HPE X130 10G SFP+ LC BiDi 10km-Uplink Transceiver JL737A
HPE X130 10G SFP+ LC BiDi 10km-Downlink Transceiver JL738A
HPE X130 10G SFP+ LC BiDi 40km-Uplink Transceiver JL739A
HPE X130 10G SFP+ LC BiDi 40km-Downlink Transceiver JL740A
HPE X130 10G SFP+ LC SR Transceiver JD092B
HPE X130 10G SFP+ LC LR Transceiver JD094B
HPE X130 10G SFP+ LC LH 80km Transceiver JG915A
HPE X130 10G SFP+ LC ER 40km Transceiver JG234A
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable JG081C
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable JL292A
FC SFP+ Transceivers
HPE StoreFabric 16Gb FC/10GbE 100m SR SFP+ Transceiver H6Z42A
HPE 8Gb Short Wave Fibre Channel SFP+ 1 Pack AJ718A
QSFP+ Transceivers
HPE X140 40G QSFP+ MPO SR4 Transceiver JG325B
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver JG709A
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver JG661A
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver JL306A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 1m Direct Attach Copper Cable JG326A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 3m Direct Attach Copper Cable JG327A
HPE FlexNetwork X240 40G QSFP+ QSFP+ 5m Direct Attach Copper Cable JG328A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable JG331A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver JL251A
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver JL286A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable JL289A
NOTE: The QSFP+ Splitter Cables (JG329A, JG330A, JG331A, JH700A) are only supported in ports 5-28
for the JG396A Switch.
The QSFP+ Splitter Cables (JG329A, JG330A, JG331A, JH700A) are only supported on the first 6
ports of the JH183A Module when used in a 4 slot switch (JH398A).
These modules (JH180A, JH181A, JH183A, JH184A, JH182A) do not support the QSFP+ Splitter
Cables (JG329A, JG330A, JG331A, JH700A) when used in a 4 slot switch (JH398A).

Page 14
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

QSFP28 Transceivers
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver JL274A
HPE X150 100G QSFP28 LC BiDi 100m MM Transceiver JQ344A
HPE X150 100G QSFP28 eSR4 300m MM Transceiver JH672A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver JH420A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver JH673A
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver JH419A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable JL273A
Cables
Remarks Description SKU
Multi-Mode Cables
HPE LC to LC Multi-mode OM3 2-Fiber 0.5m 1-Pack Fiber Optic Cable AJ833A
HPE LC to LC Multi-mode OM3 2-Fiber 1.0m 1-Pack Fiber Optic Cable AJ834A
HPE LC to LC Multi-mode OM3 2-Fiber 2.0m 1-Pack Fiber Optic Cable AJ835A
HPE LC to LC Multi-mode OM3 2-Fiber 5.0m 1-Pack Fiber Optic Cable AJ836A
HPE LC to LC Multi-mode OM3 2-Fiber 15.0m 1-Pack Fiber Optic Cable AJ837A
HPE LC to LC Multi-mode OM3 2-Fiber 30.0m 1-Pack Fiber Optic Cable AJ838A
HPE LC to LC Multi-mode OM3 2-Fiber 50.0m 1-Pack Fiber Optic Cable AJ839A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 1m Cable QK732A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 2m Cable QK733A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 5m Cable QK734A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 15m Cable QK735A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 30m Cable QK736A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 50m Cable QK737A
MPO Cables
HPE Multi Fiber Push On to 4 x Lucent Connector 5m Cable K2Q46A
HPE Multi Fiber Push On to 4 x Lucent Connector 15m Cable K2Q47A
HPE Premier Flex MPO/MPO Multi-mode OM4 12 fiber 10m Cable QK729A
HPE Premier Flex MPO/MPO Multi-mode OM4 8 fiber 50m Cable QK731A
HPE Premier Flex MPO/MPO OM4 100m (12ft) Cable H6Z30A

Page 15
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

Internal Power Supplies


Rule # Description SKU
(JH390A, JH391A) System (std 0 // max 2) User Selection (min 1 // max 2)
1, 2, 3 HPE A58x0AF Back (Power Side) to Front (Port Side) Airflow 300W AC Power Supply JG900A
• includes 1 x c13, 300w
HPE A58x0AF Back (Power Side) to Front (Port Side) Airflow 300W AC Power Supply PDU Cable JG900A#B2B
NA/JP/TW
• C15 PDU Jumper Cord (NA/MX/TW/JP)
1, 3 HPE A58x0AF Back (Power Side) to Front (Port Side) Airflow 300W DC Power Supply JG901A
• includes 1 x c13, 300w
1, 2 HPE 58x0AF 650W AC Power Supply JC680A
• includes 1 x c13, 300w
HPE 58x0AF 650W AC Power Supply PDU Cable NA/JP/TW JC680A#B2B
• C15 PDU Jumper Cord (NA/MX/TW/JP)
1, 2 HPE 58x0AF 650W AC Power Supply JC680A
• includes 1 x c13, 300w
HPE 58x0AF 650W AC Power Supply PDU Cable NA/JP/TW JC680A#B2B
• C15 PDU Jumper Cord (NA/MX/TW/JP)
HPE 58x0AF 650W AC Power Supply PDU Cable ROW JC680A#B2C
• C15 PDU Jumper Cord (ROW)
HPE A58x0AF 650W AC Power Supply JC680A#AC3
• No Localized Power Cord Selected
1 HPE FlexFabric Switch 650W 48V Hot Plug NEBS-compliant DC Power Supply JH336A
• includes 1 x c13, 650w
Configuration Rules
1 If 2 power supplies are selected they must be the same SKU number.
2 Localization (Wall Power Cord) required on orders without #B2B, #B2C (PDU Power Cord) . (See
Localization Menu)
NOTE: When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be the Defaulted Power
Cable option on the Switches/Routers.
3 This power supply is only compatible with the following Switches:
HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch JH390A

Page 16
QuickSpecs HPE FlexFabric 5940 Switch Series

Configuration Information

Fan Trays
Rule # Description SKU
(JH390A, JH391A) System (std 0 // max 2) User Selection (min 2 // max 2)
1, 6 HPE 58x0AF Back (Power Side) to Front (Port Side) Airflow Fan Tray JC682A
1, 6 HPE 58x0AF Front (Port Side) to Back (Power Side) Airflow Fan Tray JC683A
1, 2 HPE X711 Front (Port Side) to Back (Power Side) Airflow High Volume Fan Tray JG552A
1, 2 HPE X712 Back (Power Side) to Front (Port Side) Airflow High Volume Fan Tray JG553A
HPE 5930 4-slot Back (Power Side) to Front (Port Side) Airflow Fan Tray JH185A
1 HPE 5930 4-slot Front (Port Side) to Back (Power Side) Airflow Fan Tray JH186A
Configuration Rules
1 Fan Trays cannot be mixed in the same switch enclosure
2 This fan tray is only supported on JH390A, JH391A.
6 This power supply is only compatible with the following Switches:
HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch JH390A
NOTE: If there is any empty space below the switch in a rack when using Back to Front Fan Trays, JG553A,
JH185A and JC682A, the rack will receive an Air Plenum kit that takes up 1U of additional space in
the rack. The Air Plenum kit is not required on fully configured racks. This only applies for CTO Rack
Level Integration. The Air Plenum Kit is a non-saleable SKU, and is brought in automatically for CTO
Factory Rack Level Integration.

Page 17
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch (JH390A)


I/O ports and slots 48 fixed 1000/10000 SFP+ ports
6 QSFP28 100GbE ports
Additional ports and slots 1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 SFP out-of-band management port
1 SFP GbE port
1 USB 2.0
1 Mini USB 2.0
Power supplies 2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray 2 fan tray slots
The customer must order fan trays, as fan trays are not included with the switch. This system requires
two same-direction airflow fan trays to function properly. The system should not be operated with only
one fan tray for more than 24 hours. The system should not be operated without a fan tray for more
than two minutes. The system should not be operated outside of the temperature range of 32°F (0°C)
to 113°F (45°C). Failure to comply with these operating requirements may void the product warranty.
Physical characteristics Dimensions 17.32(w) x 18.11(d) x 1.72(h) in (44 x 46 x 4.36 cm)
Weight 24.25 lb (11 kg) shipping weight
Memory and processor 1 GB flash; Packet buffer size: 16 MB, 4 GB SDRAM
Performance 10 Gbps Latency < 1 µs (64-byte packets)
Throughput up to 1607 Mpps
Routing/Switching 2160 Gbps
capacity
Routing table size 120000 entries (IPv4), 60000 entries (IPv6)
MAC address table size 288000 entries
Environment Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative 10% to 90%, noncondensing
humidity
Acoustic Low-speed fan: 65.7 dB, High-speed fan: 70.6 dB
Electrical characteristics Maximum heat 887 BTU/hr (935.79 kJ/hr)
dissipation
Voltage 100 - 240 VAC, rated
-40 to -60 VDC, rated
(depending on power supply chosen)
Maximum power rating 196 W
Frequency 50/60 Hz
Notes Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure
with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and
all modules populated.
Safety UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part
2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR
Subchapter J; NOM; ROHS Compliance
Emissions VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR
47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Page 18
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

Immunity Generic ETSI EN 300 386 V1.3.3


EN EN 55024:1998+ A1:2001 + A2:2003
ESD EN 61000-4-2; IEC 61000-4-2
Radiated EN 61000-4-3; IEC 61000-4-3
EFT/Burst EN 61000-4-4; IEC 61000-4-4
Surge EN 61000-4-5; IEC 61000-4-5
Conducted EN 61000-4-6; IEC 61000-4-6
Power frequency IEC 61000-4-8; EN 61000-4-8
magnetic field
Voltage dips and EN 61000-4-11; IEC 61000-4-11
interruptions
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management IMC - Intelligent Management Center; Command-line interface; Out-of-band management; SNMP
manager; Telnet; FTP
Notes The customer must order a power supply, as the device does not come with one. At least one
JC680A or JC681A is required.
Services Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.

Page 19
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)


I/O ports and slots 48 1/10GBASE-T ports
6 QSFP28 100GbE ports
Additional ports and slots 1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 SFP out-of-band management port
1 SFP GbE port
1 USB 2.0
1 Mini USB 2.0
Power supplies 2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray 2 fan tray slots
The customer must order fan trays, as fan trays are not included with the switch. This system requires
two same-direction airflow fan trays to function properly. The system should not be operated with only
one fan tray for more than 24 hours. The system should not be operated without a fan tray for more
than two minutes. The system should not be operated outside of the temperature range of 32°F (0°C)
to 113°F (45°C). Failure to comply with these operating requirements may void the product warranty.
Physical characteristics Dimensions 17.32(w) x 25.98(d) x 1.72(h) in (44 x 66 x 4.36 cm)
Weight 28.66 lb (13 kg) shipping weight
Memory and processor 1 GB flash; Packet buffer size: 16 MB, 4 GB SDRAM
Performance 10 Gbps Latency < 1 µs (64-byte packets)
Throughput up to 1607 Mpps
Routing/Switching 2160 Gbps
capacity
Routing table size 120000 entries (IPv4), 60000 entries (IPv6)
MAC address table size 288000 entries
Environment Operating temperature 32°F to 113°F (0°C to 45°C)
Operating relative 10% to 90%, noncondensing
humidity
Acoustic Low-speed fan: 65.7 dB, High-speed fan: 70.6 dB
Electrical characteristics Maximum heat 887 BTU/hr (935.79 kJ/hr)
dissipation
Voltage 100 - 240 VAC, rated
-40 to -60 VDC, rated
(depending on power supply chosen)
Maximum power rating 320 W
Frequency 50/60 Hz
Notes Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure
with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and
all modules populated.
Safety UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part
2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR
Subchapter J; NOM; ROHS Compliance
Emissions VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR
47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)

Page 20
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

Immunity Generic ETSI EN 300 386 V1.3.3


EN EN 55024:1998+ A1:2001 + A2:2003
ESD EN 61000-4-2; IEC 61000-4-2
Radiated EN 61000-4-3; IEC 61000-4-3
EFT/Burst EN 61000-4-4; IEC 61000-4-4
Surge EN 61000-4-5; IEC 61000-4-5
Conducted EN 61000-4-6; IEC 61000-4-6
Power frequency IEC 61000-4-8; EN 61000-4-8
magnetic field
Voltage dips and EN 61000-4-11; IEC 61000-4-11
interruptions
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
Management IMC - Intelligent Management Center; Command-line interface; Out-of-band management; SNMP
manager; Telnet; FTP
Notes The customer must order a power supply, as the device does not come with one. At least one
JC680A or JC681A is required.
Services Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.

Page 21
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

Standards and protocols (applies to all products in series)


BGP
• RFC 1163 Border Gateway Protocol (BGP)
• RFC 1771 BGPv4
• RFC 1997 BGP Communities Attribute
• RFC 2918 Route Refresh Capability
• RFC 3392 Capabilities Advertisement with BGP-4
• RFC 4271 A Border Gateway Protocol 4 (BGP-4)
• RFC 4360 BGP Extended Communities Attribute
• RFC 4456 BGP Route Reflection: An Alternative to Full Mesh Internal BGP (IBGP)
• RFC 4760 Multiprotocol Extensions for BGP-4
• RFC 7432 BGP MPLS-Based Ethernet VPN
Device Management
• RFC 1157 SNMPv1/v2c
• RFC 1305 NTPv3
• RFC 1591 DNS (client)
• RFC 1902 (SNMPv2)
• RFC 1908 (SNMP v1/2 Coexistence)
• RFC 2573 (SNMPv3 Applications)
• RFC 2576 (Coexistence between SNMP V1, V2, V3)
• RFC 2819 RMON
• Multiple Configuration Files
• Multiple Software Images
• SSHv1/SSHv2 Secure Shell
• TACACS/TACACS+
MIBs
• RFC 1213 MIB II
• RFC 1907 SNMPv2 MIB
• RFC 2571 SNMP Framework MIB
• RFC 2572 SNMP-MPD MIB
• RFC 2573 SNMP-Notification MIB
• RFC 2573 SNMP-Target MIB
• RFC 2574 SNMP USM MIB
• RFC 2737 Entity MIB (Version 2)
• RFC 3414 SNMP-User based-SM MIB
• RFC 3415 SNMP-View based-ACM MIB
• LLDP-EXT-DOT1-MIB
• LLDP-EXT-DOT3-MIB
• LLDP-MIB

Page 22
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

General Protocols
• IEEE 802.1ad Q-in-Q
• IEEE 802.1AX-2008 Link Aggregation
• IEEE 802.1D MAC Bridges
• IEEE 802.1p Priority
• IEEE 802.1Q VLANs
• IEEE 802.1s Multiple Spanning Trees
• IEEE 802.1w Rapid Reconfiguration of Spanning Tree
• IEEE 802.3ad Link Aggregation Control Protocol (LACP)
• IEEE 802.3ae 10-Gigabit Ethernet
• IEEE 802.3ag Ethernet OAM
• IEEE 802.3ah Ethernet in First Mile over Point to Point Fiber - EFMF
• IEEE 802.3x Flow Control
• RFC 768 UDP
• RFC 783 TFTP Protocol (revision 2)
• RFC 791 IP
• RFC 792 ICMP
• RFC 793 TCP
• RFC 826 ARP
• RFC 854 TELNET
• RFC 856 TELNET
• RFC 868 Time Protocol
• RFC 896 Congestion Control in IP/TCP Internetworks
• RFC 950 Internet Standard Subnetting Procedure
• RFC 1027 Proxy ARP
• RFC 1058 RIPv1
• RFC 1091 Telnet Terminal-Type Option
• RFC 1141 Incremental updating of the Internet checksum
• RFC 1142 OSI IS-IS Intra-domain Routing Protocol
• RFC 1191 Path MTU discovery
• RFC 1213 Management Information Base for Network Management of TCP/IP-based internets
• RFC 1253 (OSPF v2)
• RFC 1531 Dynamic Host Configuration Protocol
• RFC 1533 DHCP Options and BOOTP Vendor Extensions
• RFC 1534 DHCP/BOOTP Interoperation
• RFC 1541 DHCP
• RFC 1542 Clarifications and Extensions for the Bootstrap Protocol
• RFC 1591 DNS (client only)
• RFC 1624 Incremental Internet Checksum
• RFC 1723 RIP v2
• RFC 1812 IPv4 Routing
• RFC 2030 Simple Network Time Protocol (SNTP) v4
• RFC 2131 DHCP
• RFC 2236 IGMP Snooping
• RFC 2338 VRRP
• RFC 2453 RIPv2
• RFC 2581 TCP Congestion Control
• RFC 2644 Directed Broadcast Control
• RFC 2767 Dual Stack Hosts using BIS
• RFC 2865 Remote Authentication Dial In User Service (RADIUS)

Page 23
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

• RFC 2868 RADIUS Attributes for Tunnel Protocol Support


• RFC 2890 Key and Sequence Number Extensions to GRE
• RFC 2929 DNS IANA Considerations
• RFC 3046 DHCP Relay Agent Information Option
• RFC 3411 An Architecture for Describing Simple Network Management Protocol (SNMP) Management Frameworks
• RFC 3412 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)
• RFC 3413 Simple Network Management Protocol (SNMP) Applications
• RFC 3416 Protocol Operations for SNMP
• RFC 3417 Transport Mappings for the Simple Network Management Protocol (SNMP)
• RFC 3418 Management Information Base (MIB) for the Simple Network Management Protocol (SNMP)
• RFC 3768 Virtual Router Redundancy Protocol (VRRP)
• RFC 4250 The Secure Shell (SSH) Protocol Assigned Numbers
• RFC 4251 The Secure Shell (SSH) Protocol Architecture
• RFC 4252 The Secure Shell (SSH) Authentication Protocol
• RFC 4253 The Secure Shell (SSH) Transport Layer Protocol
• RFC 4254 The Secure Shell (SSH) Connection Protocol
• RFC 4292 IP Forwarding Table MIB
• RFC 4293 Management Information Base for the Internet Protocol (IP)
• RFC 4364 BGP/MPLS IP Virtual Private Networks (VPNs)
• RFC 4419 Diffie-Hellman Group Exchange for the Secure Shell (SSH) Transport Layer Protocol
• RFC 4594 Configuration Guidelines for DiffServ Service Classes
• RFC 4601 Protocol Independent Multicast - Sparse Mode (PIM-SM): Protocol Specification (Revised)
• RFC 4604 Using Internet Group Management Protocol Version 3 (IGMPv3) and Multicast Listener Discovery Protocol
Version 2 (MLDv2) for Source-Specific Multicast
• RFC 4607 Source-Specific Multicast for IP
• RFC 4941 Privacy Extensions for Stateless Address Autoconfiguration in IPv6
• RFC 5340 OSPF for IPv6
• RFC 5905 Network Time Protocol Version 4: Protocol and Algorithms Specification
Network Management
• RFC 2580 Conformance Statements for SMIv2
• RFC 3164 BSD syslog Protocol
OSPF
• RFC 1587 OSPF NSSA
• RFC 2328 OSPFv2
• RFC 3101 OSPF NSSA
• RFC 3137 OSPF Stub Router Advertisement
• RFC 3623 Graceful OSPF Restart
• RFC 4577 OSPF as the Provider/Customer Edge Protocol for BGP/MPLS IP Virtual Private Networks (VPNs)
• RFC 4811 OSPF Out-of-Band LSDB Resynchronization
• RFC 4812 OSPF Restart Signaling
• RFC 4813 OSPF Link-Local Signaling
QoS/CoS
• IEEE 802.1p (CoS)
• RFC 2475 DiffServ Architecture
• RFC 2597 DiffServ Assured Forwarding (AF)
• RFC 3247 Supplemental Information for the New Definition of the EF PHB (Expedited Forwarding Per-Hop Behavior)
• RFC 3260 New Terminology and Clarifications for DiffServ

Page 24
QuickSpecs HPE FlexFabric 5940 Switch Series

Technical Specifications

IPv6
• RFC 2080 RIPng for IPv6
• RFC 2460 IPv6 Specification
• RFC 2461 IPv6 Neighbor Discovery
• RFC 2462 IPv6 Stateless Address Auto-configuration
• RFC 2463 ICMPv6
• RFC 2464 Transmission of IPv6 over Ethernet Networks
• RFC 2473 Generic Packet Tunneling in IPv6
• RFC 2545 Use of MP-BGP-4 for IPv6
• RFC 2563 ICMPv6
• RFC 2711 IPv6 Router Alert Option
• RFC 2740 OSPFv3 for IPv6
• RFC 2767 Dual Stack Hosts using BIS
• RFC 3315 DHCPv6 (client and relay)
• RFC 3484 Default Address Selection for IPv6
• RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6
• RFC 4213 Basic Transition Mechanisms for IPv6 Hosts and Routers
• RFC 4291 IP Version 6 Addressing Architecture
• RFC 4443 ICMPv6
• RFC 4552 Authentication/Confidentiality for OSPFv3
• RFC 4862 IPv6 Stateless Address Auto-configuration
• RFC 5095 Deprecation of Type 0 Routing Headers in IPv6
Security
• RFC 1321 The MD5 Message-Digest Algorithm
• RFC 2818 HTTP Over TLS
• RFC 6192 Partial Support - Protecting the Router Control Plane
• Access Control Lists (ACLs)
• SSHv2 Secure Shell

Page 25
QuickSpecs HPE FlexFabric 5940 Switch Series

Summary of Changes

Date Version History Action Description of Change


04-May-2020 Version 19 Changed Configuration Information and Related Options was updated.
Obsolete SKUs were removed.
16-Dec-2019 Version 18 Changed Configuration Information was updated.
Obsolete SKUs were removed.
03-Sep-2019 Version 17 Changed Configuration Information and Related Options were updated.
Obsolete SKUs were removed.
New SKUs were added.
04-Feb-2019 Version 16 Removed Switch Bundles removed: JH684A, JH685A, JH686A, JH691A, JH692A
SKU removed: JL250A
Removed Box Level CTO SSP Section and logic from menu and configurators
17-Dec-2018 Version 15 Changed Technical Specifications and Configuration section updated
01-Oct-2018 Version 14 Changed Configuration Information section was updated
06-Aug-2018 Version 13 Changed Configuration Information section was updated
04-Jun-2018 Version 12 Removed SKUs removed: JD093B, JL438A
07-May-2018 Version 11 Added SKU added: JH419A
02-Apr-2018 Version 10 Changed Configuration Information section was updated
04-Dec-2017 Version 9 Added SKU added: JH957A, JQ041A, JQ042A, JQ043A, JQ044A
05-Jun-2017 Version 8 Added SKU added: JH673A
03-Apr-2017 Version 7 Changed Configuration Information section was updated
06-Mar-2017 Version 6 Changed SKUs added: JL437A; JL438A; JL439A
Configuration Information section was updated
06-Feb-2017 Version 5 Changed Related Options was updated
09-Jan-2017 Version 4 Added Models added: JH684A, JH685A, JH686A, JH691A, JH692A
SKUs added: JH689A, JH690A, JH409A, JH677A, JH678A, JH679A,
JH680A, JH681A, JH682A, JH683A, JH693A, JH694A, JH695A, JH696A,
JH697A, JH698A, JH699A, JH700A, JH701A, JH702A, JH703A
07-Nov-2016 Version 3 Changed Models added: JH397A; JH398A
Edits made on Configuration and Accessories sections
05-Sep-2016 Version 2 Changed SKUs added: JL273A, JL282A, JL283A, JL284A
Overview and Technical Specifications updated
01-Aug-2016 Version 1 New New QuickSpecs

Page 26
QuickSpecs HPE FlexFabric 5940 Switch Series

Summary of Changes

Sign up for updates


© Copyright 2020 Hewlett Packard Enterprise Development L.P. The information contained herein is
subject to change without notice. The only warranties for Hewlett Packard Enterprise products and
services are set forth in the express warranty statements accompanying such products and services.
Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise
shall not be liable for technical or editorial errors or omissions contained herein.

To learn more, visit: http://www.hpe.com/networking

c05158726 - 15632 - Worldwide - V19 - 04-May-2020

Page 27

You might also like