0% found this document useful (0 votes)
49 views4 pages

Assignment I Solution (2023-2024)

This document provides the solution and marking scheme for a design assignment of a reinforced concrete beam. The summary is: 1) The beam is simply supported with a clear span of 26 feet carrying dead and live loads. Five #10 bars are provided at 16 inches effective depth. 2) Calculations show two bars can be discontinued at 6.01 feet from midspan, meeting the required development length. 3) Checks at the support where moment is zero and bar size are adequate. 4) For the discontinued bars, four #3 stirrups at 4 inches are specified as binder bars within 1.33 feet of the cut ends.

Uploaded by

soesi thu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views4 pages

Assignment I Solution (2023-2024)

This document provides the solution and marking scheme for a design assignment of a reinforced concrete beam. The summary is: 1) The beam is simply supported with a clear span of 26 feet carrying dead and live loads. Five #10 bars are provided at 16 inches effective depth. 2) Calculations show two bars can be discontinued at 6.01 feet from midspan, meeting the required development length. 3) Checks at the support where moment is zero and bar size are adequate. 4) For the discontinued bars, four #3 stirrups at 4 inches are specified as binder bars within 1.33 feet of the cut ends.

Uploaded by

soesi thu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

2023-2024 Academic Year

CE-41024, Design of Reinforced Concrete Structures I


First Semester, Assignment I
Solution and Marking Scheme
Question The beam of Figure-1 is simply supported with clear span of 26 ft and is to carry a
distributed dead load of 0.615 k/ft, not including its own weight, and live load of 1.62 k/ft,
unfactored, in service. Consider the weight of the beam. The reinforcement consists of five
No.10 (No.32) bars at 16 in; effective depth, two of which is to be discontinued where no longer
needed. Material strength specified are fy = 60,000 psi and fc' = 5,000 psi. No.3 (No.10) stirrups
are used with clear cover of 1.5 in at spacing less than ACI Code maximum.
a. Calculate at the point where the two bars can be discontinued.
b. Check to be sure that adequate embedded length is provided for continued and
discontinued bars.
c. Check special requirements at the support, where Mu = 0.
d. If No.3 bars are used for lateral reinforcement, specify special reinforcing details
(binder stirrups) in the vicinity where the No.10 (No.32) bars is cut off.
Hint: 1. Use the effective span = 26 ft because of the lack of support-width.
2. Use Table A-10 of Appendix A to check the development length of the bars. Use
case (a) or (b) in your calculation, so no need to check the case.
3. In your calculations, no need to revise beam size but the required steel area should
be calculated to obtain excess amount of reinforcement.
(25 marks)

Figure-1
Solution
(a) Effective span, L = 26 ft, D = 0.615 kips/ft, L = 1.62 kips/ft
As = 5-No.10 = 6.35 in2
22×19 1
Own weight = 150× × = 0.435 kips/ft
144 1000
ωu = 1.2(0.615+0.435) + 1.6(1.62) = 3.852 kips/ft
3.852×26
R= = 50.076 kips
2

1
2023-2024 Academic Year

ωu L2 3.852×262
Mu = = ×12 = 3905.928 k-in
8 8

2Mu 2×3905.928
a = d-√d2 - =16 -√162 - = 3.23 in
0.765f'c b 0.765×5×22

Mu 3905.928
As(reqd) = a = = 5.03 in2
ϕfy (d- ⁄2) 0.9×60×(16 - 3.23⁄2)

As(provided) = 5-No.10 = 6.35 in2 > 5.03 in2


To check ϕ
As fy 6.35×60
a= = = 4.075 in
0.85f'c b 0.85×5×22
a 4.075
c= = = 5.094 in
β1 0.8
dt - c 16 – 5.094
ϵt = ϵu =0.003× = 0.0064 > 0.005
c 5.094
Thus ϕ = 0.9 is valid.
Two bars is discontinued where no longer needed. C.O % = 40%
From Graph A-2, Theory C.O Pt = 0.18L = 0.18×26 = 4.68 ft (from mid span)
Extension length = d = 16 in
Extension length = 12db = 12×1.27 = 15.24 in
Thus, use extension length = 16 in = 1.33 ft
Actual C.O Pt = 4.68 + 1.33 = 6.01 ft (from mid span)
(b)
ld
From Table A-10, = 42
db
ld = 42db = 42 (1.27) = 53.34 in
As(required) 5.03
Modified ld = 53.34× = 53.34× = 42.252 in = 3.521 ft
As(provided) 6.35
Check ld
For discontinued bar,
Provided length = 6.01 ft > ld = 3.521 ft
For continuing bar,
The continuing bars will be extended to a point 10 in from the support face.
10
Provided length = 13 - 4.68 + = 9.15 ft > ld = 3.521 ft (OK)
12

2
2023-2024 Academic Year

(c) To check the bar size at the point of inflection


The continuing bars = 3-No.10 = 3.81 in2
As fy 3.81×60
a= = = 2.445 in
0.85f'c b 0.85×5×22
a 2.445 1
ϕMn =ϕ As fy (d- ) = 0.9×3.81×60× (16 - ) × = 253.36 k-ft
2 2 12

Mn
ld ≤ 1.3 +l
Vu a
253.36⁄
≤ 1.3 0.9 + 10
50.076 12
≤ 8.14 ft
ld = 3.521 ft < 8.14 ft (OK);
Thus the diameter of the bar is small enough.

(d) Design of binder stirrups


3 3
d = ×16 =12 in (from the cut ends of the discontinued bars)
4 4
As(cutoff) 2⁄5 As
βb = = = 0.4
As(total) As
d 16
The spacing must not exceed = = 5 in (Use 4 in)
8βb 8×0.4
Use four No.3(No.10) stirrups at 4 in.
In addition, the area of added steel within the distance s must not be less than
s 60×22×4
60bw = = 0.088in2
fy 60000
No.3 stirrups area, Av = 0.22 in2 > 0.088 in2

3
2023-2024 Academic Year

Actual C.O
Theo C.O
Mid Span

12"

Binder 4 No.3 @ 4"

0"

1.33' 4.68'
6.01' > ld
9.15' > ld

26'-0"
12" 12"

----------------------------------------------------------------------------------------------------------------
(25 marks)
----------------------------------------------------------------------------------------------------------------