ABSOLUTE MAXIMUM RATINGS
Sym bol Conditions m in. typ. m ax. Unit
System
V DClink Operating DC link voltage 750 V DC
Fsw =10 kHz, TJ<125ºC Tamb=40ºC
IU,V,W 32 A RMS
Fo=50 Hz, PF= 0.85, m=1, Vin rms=400V
IGBT 4xLUH100G1204
V CES TJ=25ºC 1200 V
non-contractual image IC TC=25ºC, TJ=175ºC 155 A
TJ Operating junction temperature -40 150 ºC
Diode
V RRM TJ=25ºC 1200 V
GPT-IGBT TC=25ºC, TJ=150ºC 100 A
IFAV
TC=80ºC, TJ=150ºC 300 A
Features TJ junction temperature 40 150 ºC
· Multi-function IGBT converter
· Transparent enclosure to allow
visualization of every part Driver
· Integrated current sensors V iH input signal voltage (high) 5 V
· Integrated voltage sensor V isolPS isolation betw een secondaries 3000 V
· Integrated drive units offering
desaturation fault detection, V isolSS isolation primary to secondary 1000 V
power-supply failure, interlock of dv/dt secondary to primary side TBD kV/us
IGBTs and galvanic isolation of f sw sw itching frequency 5 20 kHz
the user
· Forced-air cooled in a compact
design
Typical applications
· Education / Engineering: T1 T3 T5 T7
One stack can simulate almost all
existing industrial applications: R A
S B
T C
· 3-phase inverter+brake T2 T4 T6 T8
D
chopper (1/2B2I)
· Buck or boost converter
· Single phase inverter
· Single or 3-phase rectifier
DRIVER SYSTEM + SENSOR FEEDBACK
GALVANIC ISOLATION
user control
interface
150122 Rev.:1
Transparent enclosure in anodized Banana type power connections with Neat and intuitive control/sensors
aluminium and polycarbonate. schematic overlay. interface.
Reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notice.
1
PERFORMANCE CURVES
[ºC]
TJ_IGBT vs IOUT (per phase, AC output)
140
120
1kHz
100 5kHz
10kHz
20kHz
80
60
40
0 10 20 30 40 50 60 [Arms]
Condition sym b ol value Units
Ambient temperature TA 40 ºC
Input voltage (each phase) VIN 400 VRMS
Input frequency fin 50 Hz
DC link voltage VDClink 543 VDC
Modulation index m 1
Load power factor PF 0,85
Output frequency fOUT 50 Hz
Reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notice.
2
MECHANICAL DIMENSIONS (All dimensions in mm.)
Reserves the right to change limits, test conditions and dimensions given in this data sheet at any time without previous notice.