SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Device: 7UT85 Transf. Prot (2 Wind.)
Product code
Short: P1F426943
Long: 7UT85-DAAA-AA0-0WWWW0-AK0111-12111B-AAA000-000AC0-CC1BA1-CB1
Firmware: Without FW, latest CPU
Housing width: 1/2 x 19''
Housing type: Flush mounting
Binary inputs: 15
Binary outputs: 13 Relays (3 Standard, 10 Fast, 0 High-Speed, 0 Power)
Current transformers: 12 for protection
Voltage transformers: 4 standard
Measuring-transducer inputs: 0 (20 mA or 10 V, fast)
0 (20 mA, standard)
CPU: CP300
Modules in 19" row 1: IO203 , PS201 , IO202
Modules in 19" row 2:
LEDs/Push-buttons: 16 LEDs
Operation Panel: Integrated
Key switch: Without
Display type: Small display
Front Design: Standard
Power Supply: DC 60 V-250 V, AC 100 V-230 V
Redundant Power Supply: No
Communication/Plug-in modules:
Communications encryption: Normal
Integrated Ethernet port J: for DIGSI 5
Plug-in module position E: ETH-BA-2EL: 2x electric Ethernet 100 Mbit/s, RJ45 Communication Protocols:
applicable for DIGSI 5, IEC 61850-8-1 MMS and GOOSE, IEC 60870-5-104,
DNP3 TCP, Modbus TCP, Synchrophasor (IEEE C37.118 - IP), Profinet IO, SUP,
DHCP, SNTP, SNMP, etc. Redundancy protocols: Line Mode, RSTP, HSR, PRP
Plug-in module position F: Port is available but not assembled
Functions:
SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Function points class: Base + 150 function points
Note on function-points class
The function-points class results from the sum of the function points of the selected functions. You can apply these
functions as selected. The device allows also each other selection of functions as long as the sum of the required
function points is within the selected function-points class. With the maximum function-points class of 1400 it is
possible to activate all the functions in the device. The function-points exceeding 1400 are free of charge. In the
engineering phase DIGSI 5 checks that the selected configuration is suitable (capable of running in the device) before
loading it to the device.
Miscellaneous:
Warranty: 5 years
Firmware: Without FW, latest CPU
SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Functional scope 7UT85 Transf. Prot (2 Wind.):
Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
Hardware quantity structure expandable I/O
Process Bus Client Protocol (Note: This PB client x 100 =
function requires at least one dedicated
ETH-BD-2FO plug-in module, with
V8.0)
IEC61850-9-2 Merging Unit stream MU x 200 =
(Note: This function requires a
dedicated ETH-BD-2FO per stream,
with V8.0)
IEC61850-9-2 Merging Unit MU x 295 =
stream 7SS85 CU (Note: Only for
communictation with 7SS85 CU, This
function requires a dedicated ETH-
BD-2FO, with V8.40)
21/21N Distance protection Z<, V< / x 100 =
I>/(V,I)
21T Impedance protection for transformers Z< x 25 =
24 Overexcitation protection V/f x 25 =
25 Synchrocheck, synchronization function Sync x 50 =
27 Undervoltage protection: "3-phase" V< x 5 =
or "positive-sequence system V1" or
"universal Vx"
27R, Rate-of-voltage-change protection (from dV/dt x 5 =
59R V8.30)
Undervoltage-controlled reactive power Q>/V< x 5 =
protection
32, 37 Power protection active/reactive power P<>, x 10 =
Q<>
32R Reverse-power protection - P< 2x x 5 = 2x
37 Undercurrent I<
37 Power-plant disconnection protection -dP x 50 =
38 Temperature supervision >
46 Negative-sequence overcurrent I2> x 5 =
protection
46 Unbalanced-load protection (thermal) I2² t> x 5 =
SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Functional scope 7UT85 Transf. Prot (2 Wind.):
Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
47 Overvoltage protection, negative- V2> x 5 =
sequence system
47 Overvoltage protection, negative- V2/V1> x 5 =
sequence/positive-sequence system
49 Thermal overload protection , I²t
49 Thermal overload protection, user- , I²t
defined characteristic
49H Hot spot calculation h, I²t x 20 =
50/51 Overcurrent protection, phases I> 3x x 30 = 3x
TD
Instantaneous tripping at switch onto SOTF x 10 =
fault
50HS Instantaneous high-current tripping I>>>
50/51 Overcurrent protection with positive- I1>
TD sequence current I1 (from V7.9)
50N/ Overcurrent protection, ground IN>
51N TD
50N/ Overcurrent protection, 1-phase IN>
51N TD
50Ns/ Sensitive ground-current detection INs> x 5 =
51Ns for systems with resonant or isolated
neutral systems incl. a) 3I0>, b)
admittance Y0>, c) 3I0-harm> (from
V7.8)
Ground-fault detection via pulse pattern IN-pulse x 15 =
detection; Note: this stage additionally
requires the function 50Ns/51Ns or
67Ns "Sensitive ground-fault detection
for systems with resonant or isolated
neutral"
Intermittent ground-fault protection Iie> x 20 =
50BF Circuit-breaker failure protection, 3-pole CBFP x 5 =
50EF End-fault protection (Note: Only useable x 5 =
for distributed busbar protection with
7SS85 CU with V8.40)
50RS Circuit-breaker restrike protection CBRS x 20 =
SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Functional scope 7UT85 Transf. Prot (2 Wind.):
Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
51V Overcurrent protection, voltage t=f(I,V) x 10 =
dependent
59, 59N Overvoltage protection: "3-phase" V> x 5 =
or "zero-sequence system V0" or
"universal Vx"
59 Overvoltage protection: "3-phase" V> x 5 =
or "positive-sequence system V1" or
"universal Vx"
60 Voltage-comparison supervision U> x 5 =
67 Directional overcurrent protection, I>, (V,I) x 5 =
phases
67N Directional overcurrent protection, IN>, (V,I) x 15 =
ground
67N Directional overcurrent protection for IN>, (V,I) x 30 =
ground faults in grounded systems
67Ns Dir. sensitive ground-fault detection x 30 =
for systems with resonant or isolated
neutral incl. a) 3I0>, b) V0>, c) Cos-/
SinPhi, d) Transient ground-fault fct., e)
Phi(V,I), f) admittance
Directional stage with a harmonic; (V0h,I0h) x 10 =
Note: this stage additionally requires
the function "67Ns Dir. sensitive
ground-fault detection for systems with
resonant or isolated neutral"
Directional intermittent ground-fault Iie dir> x 20 =
protection
68 Power-swing blocking Z/t x 25 =
74TC Trip-circuit supervision TCS
74CC Closed-circuit supervision (from V7.9) CCS
79 Automatic reclosing, 3-pole AR x 45 =
81 Frequency protection: "f>" or "f<" or "df/ f<>; df/ x 5 =
dt" dt<>
81 AF Abnormal frequency protection fBand x 15 =
81U Underfrequency load-shedding f<(UFLS) x 15 =
Vector-jump protection > x 20 =
SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Functional scope 7UT85 Transf. Prot (2 Wind.):
Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
85/21 Teleprotection for distance protection
85/27 Weak or no infeed: echo and tripping WI
85/67N Teleprotection for directional ground
fault protection
86 Lockout
87T Transformer differential protection I
87T Differential protection for special I x 150 =
transformers
87T Differential protection (Node protection I Node
Node for auto transformer)
87T Transformer differential protection for I x 200 =
phase angle regulating transformer
(single core)
87N T Restricted ground-fault protection IN x 15 =
87M Motor differential protection I
87G Generator differential protection I x 50 =
87L Differential protection for lines with 2 I x 170 =
ends for 7UT8 (communication with
7SD82,85,86, 7SL86,87)
Option for line differential protection I x 40 =
charging-current compensation
87 Stub-fault differential protection (for x 35 =
STUB breaker-and-a-half scheme)
90V Automatic voltage controller for two- x 150 =
winding transformer
90V Automatic voltage controller for two- x 180 =
winding transformer with parallel
operation
Number of two-winding transformers 2x x 5 = 2x
with parallel operation (Note: only
together with the function "Automatic
voltage controller for two-winding
transformer with parallel operation")
90V Automatic voltage controller for three- x 200 =
winding transformer
SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Functional scope 7UT85 Transf. Prot (2 Wind.):
Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
90V Automatic voltage controller for grid x 175 =
coupling transformer
FL Fault locator, single-sided FL-one x 25 =
FL Fault locator plus (from V7.9) FL plus x 45 =
PMU Synchrophasor measurement PMU x 40 =
AFD Arc-protection (only with plug-in module
ARC-CD-3FO)
Measured values - standard
Measured values - extended: Min, Max, x 3 =
Avg
Switching statistic counters
PQ-Basic measured values: THD (Total
Harmonic Distortion) and harmonics
(from V8.01) THD voltage aggregation
values (from V8.40)
PQ-Basic measured values: Voltage x 20 =
unbalance (from V8.40)
PQ-Basic measured values: Voltage x 30 =
variations - voltage dips, swells and
interruptions (from V8.40)
PQ-Basic measured values: TDD - x 10 =
Total Demand Distortion (from V8.40)
CFC (Standard, control)
CFC arithmetic x 40 =
Circuit-breaker wear monitoring Ix, I²t, 2P x 10 =
Switching sequences function x 5 =
Inrush current detection
External trip initiation
Control
PoW Point-on-wave switching (from V7.90) PoW x 425 =
Circuit-breaker 4x x 3 = 4x
Disconnector/Grounding switch 4x x 3 = 4x
SIPROTEC 5
Configuration
Feb 24, 2021 1:02 PM
Functional scope 7UT85 Transf. Prot (2 Wind.):
Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
Fault recording of analog and binary
signals
Monitoring and supervision
Protection interface, serial
Frequency-tracking groups (from V7.8)
Transformer side 7UT85 2x x 70 = 2x
Cyber Security: Role-Based Access x 25 =
Control (from V7.8)
Temperature acquisition via
communication protocol
Cyber Security: IEEE 802.1x based x 10 =
network authentication (from V8.3)
Sum: 0