1 Input data
Anchor type and diameter: HIT-HY 270 + HAS-U 5.8 M12
Item number: 2223821 HAS-U 5.8 M12x110 (element) / 2092828
HIT-HY 270 (adhesive)
Effective embedment depth: hef,opti = 50.0 mm (hef,limit = 206.0 mm)
Material: 5.8
Evaluation Service Report: ETA-19/0160
Issued I Valid: 8/30/2019 | -
Proof: Design Method EOTA TR054
Stand-off installation: eb = 0.0 mm (no stand-off); t = 8.0 mm
Anchor plate :
R lx x ly x t = 300.0 mm x 300.0 mm x 8.0 mm; (Recommended plate thickness: not calculated)
Profile: IPBi/HEA, IPBI 140 / HE 140 A; (L x W x T x FT) = 133.0 mm x 140.0 mm x 5.5 mm x 8.5 mm
Base material: Brick layout: Double Stretcher; Brick: Mz, 2DF, f=12 (solid brick), Clay, L x W x H: 240.0 mm x 115.0
mm x 113.0 mm;
2 2
fb,v = 12.00 N/mm ; Ewall = 3,131.77 N/mm
Mortar: M2,5 - M9; Vertical joints filled: YES; vertical: 6.0 mm; horizontal: 6.0 mm
Installation/Use: Installation condition: Dry; Use condition: Dry;
Cleaning: compressed air
Temp. short/long: 40/24 °C
R
- The anchor calculation is based on a rigid anchor plate assumption.
Geometry [mm]
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.90
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.90
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:
Anchor forces are calculated based on the assumption of a rigid anchor plate.
s|| [mm] c|| [mm] sETA,|| [mm] cETA,|| [mm] ag,N,|| ec,N,|| [mm] y g,N,||
140.0 330.0 75.0 115.0 1.500 0.0 1.000
s^ [mm] c^ [mm] sETA,^ [mm] cETA,^ [mm] ag,N,^ ec,N,^ [mm] y g,N,^
240.0 430.0 150.0 115.0 2.000 0.0 1.000
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.90
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:
sETA,|| [mm] cETA,|| [mm] VRk,b,ETA,|| [kN] ag,V,|| ec,V,|| [mm] y g,V,|| aj,||
115.0 75.0 5.500 1.600 0.0 1.000 1.000
sETA,^ [mm] cETA,^ [mm] VRk,b,ETA,^ [kN] ag,V,^ ec,V,^ [mm] y g,V,^ aj,^
0.0 0.0 0.000 0.000 0.0 0.000 0.000
gM,m
2.500
b||+^
0.142
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.90
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:
sETA,^ [mm] cETA,^ [mm] VRk,c,ETA,^ [kN] ag,V,^ aj,^ ec,V,^ [mm] y g,V,^
- - - - - - -
gM,m
2.500
b||+^
0.114
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.90
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Only the local load transfer from the anchor(s) to the wall is considered, a further load transfer in the wall is not covered by PROFIS!
• Wall is assumed as being perfectly aligned vertically – checking required(!): Noncompliance can lead to significantly different distribution of
forces and higher tension loads than those calculated by PROFIS. Masonry wall must not have any damages (neither visible nor not visible)!
While installation, the positioning of the anchors needs to be maintained as in the design phase i.e. either relative to the brick or relative to
the mortar joints.
• The effect of the joints on the compressive stress distribution on the plate / bricks was not taken into consideration.
• If no significant resistance is felt over the entire depth of the hole when drilling (e.g. in unfilled butt joints), the anchor should not be set at
this position or the area should be assessed and reinforced. Hilti recommends the anchoring in masonry always with sieve sleeve. Anchors
can only be installed without sieve sleeves in solid bricks when it is guaranteed that it has not any hole or void.
• The accessories and installation remarks listed on this report are for the information of the user only. In any case, the instructions for use
provided with the product have to be followed to ensure a proper installation.
• The compliance with current standards (e.g. EOTA TR054, EOTA TR053) is the responsibility of the user.
• The Young’s modulus of the wall Ewall (not plastered!) is determined in accordance to EN 1996-1-1:2012
• Drilling method (hammer, rotary) to be in accordance with the approval!
• Masonry needs to be built in a regular way in accordance with state-of the art guidelines!
• Please note that, for ETA approved masonry units, the resistance and parameters are only valid for that particular brick (hollow/solid) or for
bricks of the same base material with larger size and larger compressive strength (solid), according to EOTA TR054.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.90
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:
7 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HIT-HY 270 + HAS-U 5.8 M12
Profile: IPBi/HEA, IPBI 140 / HE 140 A; (L x W x T x FT) = 133.0 mm x 140.0 Item number: 2223821 HAS-U 5.8 M12x110 (element) /
mm x 5.5 mm x 8.5 mm 2092828 HIT-HY 270 (adhesive)
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 10 Nm
Plate thickness (input): 8.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 50.0 mm
Drilling method: Drilled in hammer mode Minimum thickness of the base material: 80.0 mm
Cleaning: compressed air
Fastening option: Pre fastening
Hilti HAS-U threaded rod with HIT-HY 270 injection mortar with 50 mm embedment h_ef, M12, Steel galvanized, Hammer drilled installation
per ETA-19/0160
y
150.0 150.0
30.0
3 4
150.0
240.0
x
150.0
1 2
30.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.90
www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan