0% found this document useful (0 votes)
19 views8 pages

Drafts - Masonry - Jan 25, 2024

This document provides an analysis of anchor installation in masonry using Hilti anchors. It includes input data on the anchor type, material properties, and load cases. It then provides calculations of tension load, steel strength, pullout strength, and brick breakout capacity to evaluate the anchor system.

Uploaded by

Abdul khaliqu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views8 pages

Drafts - Masonry - Jan 25, 2024

This document provides an analysis of anchor installation in masonry using Hilti anchors. It includes input data on the anchor type, material properties, and load cases. It then provides calculations of tension load, steel strength, pullout strength, and brick breakout capacity to evaluate the anchor system.

Uploaded by

Abdul khaliqu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Hilti PROFIS Engineering 3.0.

90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 270 + HAS-U 5.8 M12
Item number: 2223821 HAS-U 5.8 M12x110 (element) / 2092828
HIT-HY 270 (adhesive)
Effective embedment depth: hef,opti = 50.0 mm (hef,limit = 206.0 mm)
Material: 5.8
Evaluation Service Report: ETA-19/0160
Issued I Valid: 8/30/2019 | -
Proof: Design Method EOTA TR054
Stand-off installation: eb = 0.0 mm (no stand-off); t = 8.0 mm

Anchor plate :
R lx x ly x t = 300.0 mm x 300.0 mm x 8.0 mm; (Recommended plate thickness: not calculated)

Profile: IPBi/HEA, IPBI 140 / HE 140 A; (L x W x T x FT) = 133.0 mm x 140.0 mm x 5.5 mm x 8.5 mm
Base material: Brick layout: Double Stretcher; Brick: Mz, 2DF, f=12 (solid brick), Clay, L x W x H: 240.0 mm x 115.0
mm x 113.0 mm;
2 2
fb,v = 12.00 N/mm ; Ewall = 3,131.77 N/mm
Mortar: M2,5 - M9; Vertical joints filled: YES; vertical: 6.0 mm; horizontal: 6.0 mm
Installation/Use: Installation condition: Dry; Use condition: Dry;
Cleaning: compressed air
Temp. short/long: 40/24 °C

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

Geometry [mm] & Loading [kN, kNm]

1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Load case: Design loads N = 1.500; Vx = 0.000; Vy = -1.000; no no 47
Mx = 0.000; My = 0.000; Mz = 0.000;

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

2 Load case/Resulting anchor forces y


3 4

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.375 0.250 0.000 -0.250
2 0.375 0.250 0.000 -0.250 x
3 0.375 0.250 0.000 -0.250
4 0.375 0.250 0.000 -0.250

max. compressive strain: - [‰]


max. compressive stress: - [N/mm ]
2
1 2
resulting tension force in (x/y)=(0.0/0.0): 0.000 [kN]
resulting compression force in (x/y)=(0.0/0.0): 0.000 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

3 Tension load (EOTA TR054, Section 4.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 0.375 28.133 2 OK
Pullout Strength* 0.375 1.200 32 OK
Brick breakout** 1.500 3.600 42 OK
Pullout of one brick** 1.500 9.743 16 OK

* highest loaded anchor **anchor group (anchors in tension)

3.1 Steel Strength

NRk,s [kN] gM,s NRd,s [kN] NEd [kN] A-ID


42.200 1.500 28.133 0.375 4

3.2 Pullout Strength

NRk,p [kN] aj g M,m NRd,p [kN] NEd [kN] A-ID


3.000 1.000 2.500 1.200 0.375 4

3.3 Brick breakout

s|| [mm] c|| [mm] sETA,|| [mm] cETA,|| [mm] ag,N,|| ec,N,|| [mm] y g,N,||
140.0 330.0 75.0 115.0 1.500 0.0 1.000

s^ [mm] c^ [mm] sETA,^ [mm] cETA,^ [mm] ag,N,^ ec,N,^ [mm] y g,N,^
240.0 430.0 150.0 115.0 2.000 0.0 1.000

NRk,b,ETA [kN] NRk,b [kN] cj [mm] cj,min,ETA [mm] aj


3.000 9.000 101.0 50.0 1.000

gM,m NRd,b [kN] NEd [kN]


2.500 3.600 1.500

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

3.4 Pullout of one brick


H 2 V 2 2 2
Aact [mm ] Aact [mm ] fvko [N/mm ] s d [N/mm ]
165,600 77,970 0.20 0.00

NRk,pb [kN] gM,m NRd,pb [kN] NEd [kN]


24.357 2.500 9.743 1.500

4 Shear load (EOTA TR054, Section 4.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 0.250 16.880 2 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Local brick failure* - - 15 OK
Brick edge failure in direction x-** - - 12 OK
Pushing out of one brick in direction ** N/A N/A N/A N/A

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)

VRk,s [kN] gM,s VRd,s [kN] VEd [kN] A-ID


21.100 1.250 16.880 0.250 4

4.2 Local brick failure

A1-ID A2-ID s [mm] c [mm]


3 4 140.0 330.0

sETA,|| [mm] cETA,|| [mm] VRk,b,ETA,|| [kN] ag,V,|| ec,V,|| [mm] y g,V,|| aj,||
115.0 75.0 5.500 1.600 0.0 1.000 1.000

sETA,^ [mm] cETA,^ [mm] VRk,b,ETA,^ [kN] ag,V,^ ec,V,^ [mm] y g,V,^ aj,^
0.0 0.0 0.000 0.000 0.0 0.000 0.000

gM,m
2.500

VRk,b,|| [kN] VRd,b,|| [kN] VEd,|| [kN] b||


8.800 3.520 0.500 0.142

VRk,b,^ [kN] VRd,b,^ [kN] VEd,^ [kN] b^


0.000 0.000 0.000 -

b||+^
0.142

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

4.3 Brick edge failure in direction x-

A1-ID A2-ID s [mm] c [mm]


3 1 240.0 430.0

sETA,|| [mm] cETA,|| [mm] VRk,c,ETA,|| [kN] ag,V,|| aj,||


150.0 75.0 5.500 2.000 1.000

sETA,^ [mm] cETA,^ [mm] VRk,c,ETA,^ [kN] ag,V,^ aj,^ ec,V,^ [mm] y g,V,^
- - - - - - -

gM,m
2.500

VRk,c,|| [kN] VRd,c,|| [kN] VEd,|| [kN] b||


11.000 4.400 0.500 0.114

VRk,c,^ [kN] VRd,c,^ [kN] VEd,^ [kN] b^


- - - -

b||+^
0.114

5 Combined tension and shear loads (EOTA TR054, Section 4.2.3)


bN bV a Utilization bN,V [%] Status
0.417 0.142 1.000 47 OK

(bN + bV) / 1.2 £ 1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Only the local load transfer from the anchor(s) to the wall is considered, a further load transfer in the wall is not covered by PROFIS!
• Wall is assumed as being perfectly aligned vertically – checking required(!): Noncompliance can lead to significantly different distribution of
forces and higher tension loads than those calculated by PROFIS. Masonry wall must not have any damages (neither visible nor not visible)!
While installation, the positioning of the anchors needs to be maintained as in the design phase i.e. either relative to the brick or relative to
the mortar joints.
• The effect of the joints on the compressive stress distribution on the plate / bricks was not taken into consideration.
• If no significant resistance is felt over the entire depth of the hole when drilling (e.g. in unfilled butt joints), the anchor should not be set at
this position or the area should be assessed and reinforced. Hilti recommends the anchoring in masonry always with sieve sleeve. Anchors
can only be installed without sieve sleeves in solid bricks when it is guaranteed that it has not any hole or void.
• The accessories and installation remarks listed on this report are for the information of the user only. In any case, the instructions for use
provided with the product have to be followed to ensure a proper installation.
• The compliance with current standards (e.g. EOTA TR054, EOTA TR053) is the responsibility of the user.
• The Young’s modulus of the wall Ewall (not plastered!) is determined in accordance to EN 1996-1-1:2012
• Drilling method (hammer, rotary) to be in accordance with the approval!
• Masonry needs to be built in a regular way in accordance with state-of the art guidelines!
• Please note that, for ETA approved masonry units, the resistance and parameters are only valid for that particular brick (hollow/solid) or for
bricks of the same base material with larger size and larger compressive strength (solid), according to EOTA TR054.

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

7 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HIT-HY 270 + HAS-U 5.8 M12
Profile: IPBi/HEA, IPBI 140 / HE 140 A; (L x W x T x FT) = 133.0 mm x 140.0 Item number: 2223821 HAS-U 5.8 M12x110 (element) /
mm x 5.5 mm x 8.5 mm 2092828 HIT-HY 270 (adhesive)
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 10 Nm
Plate thickness (input): 8.0 mm Hole diameter in the base material: 14.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 50.0 mm
Drilling method: Drilled in hammer mode Minimum thickness of the base material: 80.0 mm
Cleaning: compressed air
Fastening option: Pre fastening

Hilti HAS-U threaded rod with HIT-HY 270 injection mortar with 50 mm embedment h_ef, M12, Steel galvanized, Hammer drilled installation
per ETA-19/0160

y
150.0 150.0

30.0
3 4
150.0
240.0

x
150.0

1 2
30.0

80.0 140.0 80.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -70.0 -120.0 430.0 470.0 880.0 1,120.0
2 70.0 -120.0 570.0 330.0 880.0 1,120.0
3 -70.0 120.0 430.0 470.0 1,120.0 880.0
4 70.0 120.0 570.0 330.0 1,120.0 880.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.90

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Masonry - Jan 25, 2024 Date: 1/25/2024
Fastening point:

8 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior
to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you
put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by
you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with
regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to
interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability
for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like