0% found this document useful (0 votes)
98 views10 pages

Pgcil - CCTV TS

TS-3

Uploaded by

sbt.abhishek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
98 views10 pages

Pgcil - CCTV TS

TS-3

Uploaded by

sbt.abhishek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 10
Dp Power Grid Corporation of India Ltd = Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) 7A 17.2 173 174 3(A).17 Close Circuit Television System (CCTV): The requirements of security system vary as per the requirement along with its geographical location. This document gives overview of CCTV services designed for the proposed Data Center at Manesar. System Objective ‘To enable the important areas of the premises to be remotely monitored. To enable sensitive areas to be scanned from pre-selected position To enable automatic recording by Server on hard disk and to play back the recorded events on selected monitors & back-ups of the events on CD/DVD. System Requirement ‘The CCTV System shall be real — time, true IP- based system consisting of Day Night PTZ Cameras, indoor varifocal dome cameras, indoor varifocal fixed ‘camera, outdoor varifocal dome cameras, outdoor varifocal fixed camera. It should have real time recording & data fetching feature using suitable capacity Network Video Recorder (NVR), switches, interfaces and monitors and all equipment necessary for functioning of the system. Recommended Areas under Surveillance Following spaces shall be provided with cameras: > Corridors Main lift lobby v Data Centre > BMS & CCTV control room > Main lobby & lobby entrance > Main building entrance (outdoor type) > Strategic places inside building > Lift car > Lift lobby on each floor > External Area Monitoring > Campus Entry/Exit > Generator / Transformer Area > ‘Access control Doors > UPS and Battery Area > ‘Any space required by Employer General System Considerations The security console shall be located in the security room. This room shall have no EIGN aT oT PaCRaG OCTANE Page 71 of 254 n Dp Power Grid Corporation of India Ltd ae Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) wesis vl VIL vin windows, Ample space shall be provided to view monitors. A video wall wil be constituted for viewing images & dedicated personnel will be monitoring the same. ‘The images can also be exported through secret network to the nearest police station in case of any emergencies, Care shall be taken to ensure that the number of displays per screen is limited so that “individuals” can be recognized when viewing the display in all areas. The Proposed storage solution is modular enough to ensure compliance to the changes in storage / recording policy, to be evolved upon initial deployment of the system. The storage solution proposed is that the video feeds would be available for 30 days. After 30 days, the video feeds should be transfer to different server and the recoding should be of 60 days after 60 days it should be overwritten unless it is flagged or marked by the Team for investigation or any other purpose. The Recording System, once configured, shall run independently of the Video Management system and continue to operate if the Management system is off-line. The system shall support the use of separate networks or switches for connecting the cameras to the recording system to provide physical network separation from the clients and facilitate the use of static IP addresses for the devices. ‘The system shall support high resolution digital video of using the H.264/ H. 265 or latest compression algorithm video compression. The system shall record the native frame rate and resolution supplied by the camera or as configured by the operator fram the System Administration Server. The system shall allow for the frame rate, bit rate and resolution of each camera to be configured independently for recording. The system shall allow the user to configure groups of cameras with the same frame rate, bit rate and resolution for efficient set-up of multiple cameras simultaneously. The system should support redundant mode. The system shall natively support intelligent video analytics that can be enabled with the software license. The build in intelligent video analytics shall be easily switched between any of the video channels. License For image recording following procedure shall be adopted: ‘= CCTV recording method shall be VMS based. + Utilizing “Watermarking” software to ensure integrity of all image recording ‘+ Memory to maintain a record at 20 fps at 2 MP resolution for 90 days minimum storage time, or as local laws requirements, whichever is a longer. ‘+ Administration functions for user access and system auto recovery as required, ‘*Real time monitoring of all images as required, ‘+n screen display function as a standard requirement EIGN aT oT PaCRaG OCTANE Page 7200f 254 n Dp Power Grid Corporation of ndia Ltd @p sas “IP Powenario Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) ‘> Use of Pan Tit & Zoom (PTZ) cameras shall be reduced to a minimum, 17.5 _ Installation Requirements Cameras located at complex driveways, and parking ramps shall be capable of clearly recording all vehicle license plate numbers and type of vehicles. Colour TV ‘cameras and monitors shall be used in locations where this is perceived as having a particular advantage based on “local” conditions or requirements. However, vehicle monitoring shall utilize colour cameras at all times. Picture quality of all cameras shall have a resolution of 2 Mega Pixel minimum, Camera locations shall insure that picture “glare” is not present at the CCTV monitors in the control room, Cameras located at complex entry, front desk, server racks lift lobbies, and fire exits, and corridors shall be capable of recording an identifiable image of all persons entering the area. Where cameras in corridors are installed, it shall be possible to identify any person entering any room. For public areas, CCTV cameras shall normally be concealed in a dome shape ‘enclosure. Some cameras shall have special protection (Cameras exposed to weatherproof shall be for exterior areas, vandal proof, etc.) depending on their locations. 17.6 Interfaces Power to cameras & all associated equipment shall be supplied by the emergency generators. Telephone provisions shall include ISNN, PSTN & TCP/IP as appropriate. 17.7 Video Management Software. 17.7.1 A. VMS features i. VMS should have quick set up wizard for easy initial configuration ji, All windows should be independently resized to get best possible layout as per user's requirements in VMS ili, A Single click ‘Fit to screen size' support for all windows by VMS iv. VMS should be able to support Multiple monitors. v, Automatic optimization option in server should be there to lower the resources utilization, after the settings are done vi, One click should be able to import and export of all settings for backing up or for replicating the same set up on another computer vii, VMS Should be able to View video channels list as - a list or as thumbnails vil, The System should be able to take automatic daily configuration backup for server application as well as client application, so that configuration is never lost. ix. VMS should work as Watchdog for all applications which need to run 24X7 — server application, client application, failover server application etc x, System notifications for all abnormal conditions should be able to displays the current state of the system. System notifications to be a separate indication EIGN aT oT PaCRaG OCTANE Page 73 of 254 B Dp Power Grid Corporation of ndia Ltd @p sas “IP Powenario Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) window and the notifications to be removed automatically by the software only when the issue is resolved. xi, ‘Screen layout’ feature to be configure and store different layouts with specific cameras. So that any layout can be quickly selected for quick view of specific set of cameras in pre-configured layout. xii, ‘Screen layout sequence’ to be switch between ‘screen layouts’ as per pre- defined switching time — with support for different switching time for each screen layout xiii, System should support following features of Video Capturing. a) Triple stream camera - separate streams should be configured for recording, display and video analytics b) Hybrid system - analog cameras support ©) Support for video Y-flip to manage videos with different co-ordinate systems, in most optimized way d) Low FPS recording in non-alarm condition and full FPS recording on alarm - with pre and post alarm interval setting e) Open architecture — supports video cameras and video sources from several manufacturers f) Supports ONVIF Compliant video sources xiv. VMS should options of overlay video in following way: a. Separate video overlay options for normal viewing screens and high-resolution video windows b. Ability to enable/disable different overlays independently — video time, camera name, camera IP address, bandwidth usage, FPS, resolution etc ¢. Video recording state indicator overlay xv. VMS should be able to Integration with other following security Devices a. Support for integrating other security devices like access control system, fire alarm system etc. b. Ability to associate primary and secondary video channels with any other security device, so that video evidence is available for all alerts generated by the other security devices xvi, VMS software should have ability to manage the following Alarms management i. Alarms stacking / Queuing ii, Displaying live and alarm video both, when alarm is generated ili, Feature to launch playback screen for any alarm, where multiple channels along with alarm generator channel can be played back synchronously iv. Ability to configure ‘send SMS' on alarm, through ‘Phone Network gateway’ v. Ability to configure ‘initiate phone call’ on alarm, through ‘Phone Network gateway’ vi. Ability to launch any EXE / script file / Macro on alarm vii. Ability to configure moving one or more PTZ cameras to pre-defined positions when a specific alarm is generated xvii, VMS should be able to view video at following: EIGN aT oT PaCRaG OCTANE Page 74 of 254 74 Dp Power Grid Corporation of ndia Ltd @p sas “IP Powenario Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) i. Up to 16X rewind and 16 X fast forward options in playback li, Up to 14 live video screens and 14 playback screens can be opened simultaneously and can be configured independently for channels to be displayed, layout and other arrangement options ili, Quick access toolbar for every individual video window iv. Operator screen - single screen video control to view live video, switch to playback and control FF, rewind etc for all channels displayed in the window simultaneously v. Magnification glass on videos - live video as well as playback video vi, Digital auto-tracking vii, On-video digital PTZ vii. Option for "View video in square pixels’ without deformation — maintaining the aspect ratio of the captured video ix. Ability to view original video stream and ‘vibration removed’ video stream together — side by side x. Ability to view original video stream and ‘digital auto tracked’ video stream together — side by side xi, Video panorama / video stitching wii, VMS should be able to configure separate IP addresses for input and output, hence providing ability to fully separate out camera network (input) from clients network (output) and should be able support Remote client with port forwarding on server. xix. VMS should be able show Maps on following bases. i. Map presets ii, Interactive maps - Google maps and Openstreet maps iii, Live video display on map — for both static as well as interactive maps xx. VMS should be able give the create or schedule the Reports on following bases Scheduled daily alarm reports generation Scheduled daily alarm reports e-mails to pre-defined recipients ©. Resources monitoring feature which logs utilization for all resources like CPU usage for each core, memory usage, threads, handles, hard disk space etc and reports generated as graphs. d. Reports can be exported in several formats — TXT, CSV, XML, PDF e. System health report application — which can query one or more server applications and generate combined report for specified duration f, The VMS software should be able to Video export in standard WMV/MP4 format — full resolution video g. Data management in VMS should have following option h. Option to exclude alarm video data during disk recycling and clean up operations. i. Scheduled data archive support — can archive the older data, before the specified number of days, as per the specified schedule j. ‘Start’ and ‘Stop’ thresholds for controlling the recycling process precisely EIGN aT oT PaCRaG OCTANE 75 Dp Power Grid Corporation of ndia Ltd @p sas “IP Powenario Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) 178 179 ‘VMS Analytics features. leo analytics on IR cameras and thermal cameras 2. Support for video analytics on Bullet, PTZ and Dome cameras, while the camera is in ‘Home’ position. Video analytics is automatically disabled when camera moves from the home position and video analytics is automatically starled when camera is moved back to home position 3. Seamless integration of video analytics module as video analytics is not a separate software application. No manual synchronization and maintenance is needed 4. Dedicated video analytics screen to display analyzed videos from multiple cameras, with analytics meta-data overlay. Quick access to video analytics settings for each camera . Independent video analytics settings for every camera . Easy to manage, tightly integrated simple user interface Enhanced algorithms which need only few parameters to be configured to get good results from video analytics in most of the deployment situations. Advanced parameters are available, to handle special situations 8. Availability of wide range of standard analytics features 9. Intrusion detection 10. Wrong direction movement 11. Line crossing / trip-wire 12. Camera tamper / scene change detection 13. Crowd detection 14. Un-attended object detection 15. Asset protection 16. _ Loitering detection 17. Object detection 18. People counting, Vehicles counting 19. Digital auto-tracking 20. Motion detection VMS Client software ‘VMS client software should be able run-on following system and able to operate following features. Smartphone client - windows mobile OS Smartphone client - android OS ‘Automatic time synchronization between server and all connected clients |. Automatic client software upgrade, if required . Multissite monitor client — can connect to multiple servers and view combined data . Windows client software - support for ‘sites book’ which can remember connections to different servers and can be used for quick connection to any of the servers without needing to type all information again 7. Windows client software — ability to reset server application from client user interface, if logged in user has the relevant privileges 8. Windows client software ~ ability to control maximum number of screens and maximum number of cameras that can be displayed in a screen gReNs EIGN aT oT PaCRaG OCTANE Page 76 of 254 76 Dp Power Grid Corporation of ndia Ltd @p sas “IP Powenario Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) 17.10 a, c 9. Windows client software — ability fo set the main screen as live video screen with no playback options 10. Windows client software — automatic download and upgrade option, if server software version does not match with client software version. CCTV CAMERAS The camera shall employ complete solid-state circuitry, ensuring high operational reliability. The cameras being considered for this project shall be coloured with one third or one fourth imager size. The camera shall deliver well defined, clear, high resolution with minimum 2 MP, Colour picture without lag or geometric distortion, ‘The camera shall also possess the following features: Excellent sensitivity for usable picture suited to the ambient light level conditions and its variations. A high sensitive automatic light compensation circuit ensuring constant video signal independent of wide variations in light levels. High resolution Low power consumption Phase adjustable line lock facility or with internal crystal oscillator The camera unit shall be complete with all electronic circuitry, devices, components, standard mount for lenses, mounting assemblies ete. The mounting assemblies of the cameras shall be individually selected depending upon the special requirements as per actual site conditions. Camera should be BIS standard(Indian Standard IS:13252) compliance 17.101 Details of Camera: DOME CAMERA IP Network TON Low-Light IR Dome Camera, 1/3" CMOS, 2 MP @ 25fps or better, triple stream, Min, Ilumination required 0.2 lux @ F1.4 (colour), 120dB' True WDR, Min. Pixels 1920*1080p, triple stream, 3mm - 12 mm motorized focus & zoom lens, Intelligent Video Analytics such as Tripwire, Object Removed, Object Left Behind, etc Backlight Compensation, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with upto 20m IR distance, H.264& MJPEG, Dual channel Audio G711alG.711U/AAC, 128GB SD card support, IP 54 & IK10, Alarm: 1 In & tout, PoE, H.264 High Profile and MJPEG, PoE Class 3/ 12V DC/24VAC, Die-Cast Aluminium Construction, Having Operating temp range : -0°C to 60° C. Certifications ONVIF Profile S & Profile G compliant. Safety Certification UL, CE, EN, FCC &RoHS compliant. Cyber security Certification : UL-CAP, Must support Video Analytical software BO. cal ‘OUTDOOR TP Network TDN Low-Light IR Outdoor Box/Bullet type fixed x Camera, 1/3" CMOS, 2 MP @50fps, triple stream, Min MERA Ilumination required 0.01 lux @ F1.4 (colour), 120dB True WOR, Min, Pixels 1920*1080p, triple stream, 5mm - 50mm variable focus & zoom lens, Intelligent Video Analytics such as Tripwire, Object Removed, Object Left Behind, etc. Backlight ‘Compensation, Highlight Compensation, 3DNR, Privacy Mask, InternaliExternal Smart IR LEDs with upto 50m IR distance, H.264& MJPEG, Dual channel Audio G.711a/G.711W/AAC, 4128GB SD card support, IP 54 & IK10, Alarm: 1 In & tout, PoE, Tey Tal oF Package D-CANE Page 77 of 254 ” Dp Power Grid Corporation of India Ltd Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) Construction, Having Operating temp range : - H264 High Profile and MJPEG, PoE Class 3/ 12V DC/24VAC, Die-Cast Aluminium C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CE, EN, FCC &RoHS compliant. Cyber security Certification : UL CAP, Must support Video Analytical software 17.41 Viewing Methodology: 47.12 Video will be viewed by dedicated monitors or video walls as will be required at detailengineering stage. 58" LED TV 58" LED TV with 1920x1080 full HD resolution and as per specifications attached suitable for mounting on wall including connection etc. 75" LED TV 75" LED TV with 1920x1080 full HD resolution and as per specifications attached suitable for mounting on wall including connection etc. Switches det: 36 port L2 | 36 port L2 Managed switch having port density 36 Nos of Managed 40M/100M/1G RJ45 Port POE /POE+ ports , 2 Nos of GbE switch RJAB/SFP Combo Port , 1X console port , Available POE power 370 W , 52 Gbps switching bandwidth , 8K MAC address support , Support L2 feature STP, RSTP MSTP ‘Support 802.1@ VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE '802.3ad LACP . L3 features - static routing , DHCP feature Device Management system - topology view , floor view . map view , dashboard , traffic monitoring , cable diagnostics.CE,FCC certified 24 port L2 | 24 port L2 Managed switch having port density 24 Nos of Managed 40M/100M/1G RJ45 Port POE /POE+ ports , 2 Nos of GbE. switch RJAB/SFP Combo Port , 1X console port , Available POE power 370 W , 52 Gbps switching bandwidth , 8K MAC address support , Support L2 feature STP, RSTP .MSTP ‘Support 802.10 VLAN , port based VLAN , 4K VLAN entries. | MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP feature , Device Management system - topology view , floor view , map view , dashboard , traffic monitoring , cable diagnosties CE,FCC certified EIGN aT oT PaCRaG OCTANE Page 78 of 254 78 Dp Power Grid Corporation of ndia Ltd @p sas “IP Powenario Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) Access Control System (ACS) EIGN aT oT PaCRaG OCTANE Page 79 of 254 Dp Power Grid Corporation of india Ltd. ae Volume Il- Technical Specification for Construction & Interiors af Greentiols datacenter bulding including Mecharical & Electrical works (Package DC-CAME) 3(A).18 Access Control System (ACS): - The requirements of security system vary as per the requirement along with its geographicallocation. This document gives overview of ACS services designed for the proposed Data Centre at Manesar. 18.1 System Objective + To enable personnel & vehicle entry to campus by recognized/ authorized personnel only. + Toenable material entry to campus by recognized/authorized means. + To enable the important/sensitive areas of the premises to be accessed by respective authorized personnel only. + Toenable sensitive areas to be scanned for restricted entry of material + To enable automatic access depending upon user rights & recording via Recorder on hard disk and to play back the recorded events on selected monitors & back-ups of the events on CD/DVD. + To enable different systems like Access to individual racks, Doors, Individual floors through lifts, Flap barriers, Man traps, Proximity card, Biometric attendance & office hours clocked to be integrated with Access Control System (ACS). 18.2 System Requirement The ACS System shall be real — time, true IP- based system consisting IP Access-controllers. It should have requisite hardware like barriers, EM locks, RFID readers etc. to carry out restricted access. It should provide real time recording & data fetching feature using suitable capacity Recorder, switches, interfaces and monitors and all equipment necessary for functioning of the system. + Recommended Areas under Access Control > Utility Area > Server Halls corridor > Offices > Chillers plant Room + Biometric > Server Halls > Telco Rooms > Media Rooms > NOC and SOC Rooms + _HIDREADERS > Utility Area > BMS > Security > EIGN aT oT PaCRaG OCTANE Page a0 of 254 80

You might also like