0% found this document useful (0 votes)
780 views29 pages

SSR Aoyi

The document discusses solid state relays (SSRs), including their basic characteristics, classifications based on operating mode and components, mounting types, output voltage grades, and factors to consider when selecting an SSR based on the type of load.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
780 views29 pages

SSR Aoyi

The document discusses solid state relays (SSRs), including their basic characteristics, classifications based on operating mode and components, mounting types, output voltage grades, and factors to consider when selecting an SSR based on the type of load.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

2013-2014

CATALOG

Place your
Order now!
And get
20% OFF
20% OFF
the price
Why do you choose
our company?

Shanghai AOYI Electric Company


limtid owns two producing factories
with 20 years production history.

It is dedicated to developing,
producing and marketing Solid State
Relay,SCRPower Regulator,Ampere
or Voltage Meter,Temperature Control
Instrument,etc.

We devote to be the best supplier of


products and services to our global
custormers at the best price.

100%
SATICFACTION
Look what you can buy?
OUR CUSTOMER IN THE WORLD

Some countries in Europe also began using our products,


with top grade products and excellent service,we obtain
accordant appreciation from them

Our products have been sold far to North America. Our products fit Asia maket perfectly, for our products
We have wonn favorable comments from American are very cheap but high quality,especially in China our
customers. products cover every province and city.

We have already entered Africa market, and our prodcuts


are very popular in Africa. We will help them to develop
the economy.

In South America we have hold a few marketing


share, and this will be more and more.
AC Solid State Relay
SSR SSR
AC Solid State Relay

SUMMARY How to select SSR?

Solid state relay is usually called SSR for short. It is a new type of nono-contact switching device First, you should know classification of solid state relay,more details are as following:
SSR is usually a four-terminal active device including two control terminals and two output 1. ON-OFF Mode:zero cross triggering and random triggering
terminals, and input and output terminals adopts reliable isolation.
Solid state relay adopts flame resistant engineering plastic case, epoxy resin encapsulation, Zero cross triggering can be used as “switch”,
screw thread educing terminal connection with high strength structure, impulse resistance,high Random triggering can be used to control shift phase pulse to adjust load voltage.
shock resistance performance, small driving current for input terminal and convenient 2. Output Components:bidirectional SCR output(ordinary type) and anti-paralleled
connection with computer teminal and digital control circuit. two single phase SCR(enhanced type):
Ordinary type is used for low current module or resistive load.
Basic Character of Solid State Relay
Enhanced type is used for high current module or inductive load.
Input signal can make computer terminal and digital logic circuit compatible.
3. Mounting Type: PCB tapered plug type,rail type,bolt type
Optical isolation between input and output loop, 4000VAC dielectric withstanding
voltage Cooling way of PCB tapered plug type is air-cooling,need not to match radiator.
LED indication for working state Rail type is cooled by air or radiator
Built-in RC absorption circuit Bolt type is cooled by radiator.
Dielectric insulating strengh: > 50MΩ 4. Output Voltage Grades:220VAC,380VAC,480VAC,660VAC
Action reponse time:ON > 10mS OFF < 10mS 220VAC voltage grades is used for 220VAC resistive load
380VAC voltage grades is used for 220VAC inductive load and 380VAC resistive load
Wiring Connection Simple High Voltage Thyristor
480/660VAC voltage grades is used for 380VAC inductive load.

-4 1
Second, you should know current of solid state relay,more details are as following:
zero-cross-over triggering loop

OUT
constant current input circuit

ON OFF Load
1.Resistive Load:≥twice load rated current
1 ~ 24~380VAC ~ 2
2.AC Motor Load:≥6-7 times motor rated current
R
3.AC Electromagnet,Intermediate Relay and Inductive Coil Load:≥4 times load rated
3-32VDC

Solid State Relay 24-380VAC

SSR-40DA 40A
current
4 _
INPUT
3~32VDC + 3
4.Power Compensator Capacitor Load:≥5 times load rated current
IN DC3-32V 5.Transformer Load:≥5 times transformer primary rated current
+3 2
6.Special Inductive and Captive:you should enlarge current margin according to
practical experience
Zero-crossing triggering, eliminates the Core adopts:imported components,
surge current completely endure high current and voltage How to protect SSR?
1.Proper radiator adapted to the working requirement of solid state relay should be
New Design Conform to IP Protection Manufacturing Technique
equipped, the allowance should be widened when the load radiating condition is not
so good.You must avoid load short circuit.
2.Over Current Protection:over current and short circuit are the main reasons for
permanent damage of internal SCR ,fast fuse and air switch is one of the methods for
over current protection, fuse is also available for small current.
3.Over Voltage Protection:you can parallel voltage dependent resistor,its thickness
decides the protective voltage value,generally,471/10D voltage dependent resistor
Pretty cap-exterior match safe and high We select high quality SCR, DCB
is suitable for 220V series SSR, 681/10D for 380V series SSR, 821/10D for 480V
quality requirement ceramic substrate and SMT technics.

01 02
Single Phase Solid State Relay
SSR SSR
Single Phase Solid State Relay

Application Three Phase Solid State Relay


Solid state relay is widely used in automatization control fields such as petrochemical A
B
equipment,food machine,packaging machine,textile machine,plastic machine,numerical C
N
control lathe,entertainment facility and so on, which especailly for severe environment
full of corrosion,moisture,explosion-proof and dust-proof or places demanding frequent

Thermocouple
PV

A1 B1 C1
switching. SV R
SSR3-40DA
- THREE PHASE 40A

Generally, our solid state relay are applied with temperature controller to control SOLID STATE RELAY

+
4~32VDC
24~380VAC

AT ON OFF ALM1 ALM2 + +


MADE IN HUANAN


Voltage
temperature of some machine, and different solid state relay should correspond to - 《
_ Pulse
A2 B2 C2


SET Output

different output of temperature controller. The following wiring diagrams are for your R
XMT-2000

reference only,please carry on the revision according to the actual need.

Single Phase Solid State Relay A


B
C
N
DC-AC Solid
DC-ACStateRelay
Solid State Relay AC-AC Solid StateRelay

Thermocouple
PV

A1 B1 C1
SV
Power AC24-380V LOAD Power AC24-380V LOAD R
SSR3-40DA
-
FUSE FUSE THREE PHASE
SOLID STATE RELAY
40A

+
4~32VDC
24~380VAC

AT ON OFF ALM1 ALM2 + +


MADE IN HUANAN


Voltage A2 B2 C2
_ Pulse
- 《


SET Output
Thermocouple

Thermocouple

R
XMT-2000
PV PV
1 ~ 24~380VAC ~ 2
220VAC 1 ~ 24~380VAC ~ 2 220VAC
R
SV R
SV

Solid State Relay


Solid State Relay

+ AT ON OFF ALM1 ALM2 + SSR-40DA 40A + AT ON OFF ALM1 ALM2


Relay
SSR-40AA
INPUT
40A

Voltage INPUT
4 ~ 90~250VAC ~3
_ Pulse 4 _ + 3 Output
- 《
3~32VDC
- 《

SET SET
Output
Above is Y connection,load votage is 220VAC,for three-phase unbalanced
R R
XMT-2000 XMT-2000
load,you should select NO.1 and the center must be zero line.
A
B
C
Manual Solid State Voltage Regulator Random Solid State Voltage Regulator N

Thermocouple
PV

Power AC24-380V LOAD Power AC24-380V Attention


LOAD
SV
A1 B1 C1

R
SSR3-40DA
-
N THREE PHASE
SOLID STATE RELAY
40A

+
4~32VDC
24~380VAC

FUSE AT ON OFF ALM1 ALM2 + +


MADE IN HUANAN

FUSE


Voltage A2 B2 C2
_ Pulse
- 《


Thermocouple

SET Output

500K potentiometer 1 ~ 24~380VAC ~ 2


PV
1 ~ 24~380VAC ~ 2
R
XMT-2000
220VAC
control output% R
SV R

Solid State Relay Solid State Relay


SSR-25VA
+ Voltage SSR-40DA-P
25A
AT ON OFF ALM1 ALM2 40A

INPUT
4 ~ 500KΩ 1/4W ~3 Pulse 4 _ + 3

4~8VDC
SET - Output
R
XMT-2000
Above is △ connection,load voltage is 380VAC,load must be three-phase
balanced. And only three phase high voltage enhanced solid state relay is
suitable for this connection.

03 04
SSR
Single Phase AC Solid State Relay
SSR
Single Phase AC Solid State Relay

Switching Zero cross Switching Zero cross


Output Bidirectional SCR Output Bidirectional SCR
Application:
Control input DC3-32V
Have load over current or short-circuit
Load Voltage 24-380VAC protection. It provides a reliable
Monitoring Output status guarantee for some machines which is
easy to short circuit.

Parameters SSR-380D05 SSR-210B Parameters SSR-40DA-S SSR-F-25/40DA


Special Functions PCB Solid State Relay Miniture Size Special Functions Over-current Protection Built-in Fast Fuse
Input Circuit Input Circuit
Control Voltage DC3-32V DC3-32V Control Voltage DC10-18V,DC20-28V DC4-32V
Control Current DC6-12mA DC6-12mA Control Current ≤12mA DC6-12mA

Output Circuit Output Circuit


Load Voltage Range 24-380VAC 24-380VAC Load Voltage Range 24-380VAC 24-380VAC
Load Current 5A 10A,20A Load Current 40A 25A,40A
Off-state Leakage Current ≤4mA ≤4mA Off-state Leakage Current ≤4mA ≤4mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time ≤10mS ≤10mS On-off Time ≤10mS ≤10mS
General Data General Data
Dielectric Strength 1500VAC 1500VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 100MΩ@ 500VDC 100MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods PCB or Bolt Fixing Bolt Fixing Mounting Methods PCB or Bolt Fixing Bolt Fixing
Work Instructions LED / Work Instructions LED LED
Net Weight 56g 30g Net Weight 157g 118g
Installation Demensions Installation Demensions

05 06
SSR
Single Phase AC Solid State Relay
SSR
Single Phase AC Solid State Relay

Switching Zero cross Switching Zero cross


Output Bidirectional SCR Output Bidirectional SCR
Load Current 10A-90A Load Current 10A-90A
Load Voltage 24-380VAC Load Voltage 90-480VAC
Monitoring Output status Monitoring Output status

Parameters SSR-(10-90)DA SSR-(10-90)DA Parameters SSR-(10-90)DA-H SSR-(10-90)DA-H


Special Functions / Imported SCR Special Functions High Voltage SCR Imported High Voltage SCR
Input Circuit Input Circuit
Control Voltage DC3-32V DC4-32V Control Voltage DC3-32V DC4-32V
Control Current DC6-12mA DC6-12mA Control Current DC6-12mA DC6-12mA

Output Circuit Output Circuit


Load Voltage Range 24-380VAC 24-380VAC Load Voltage Range 90-480VAC 90-480VAC
Load Current 10A,15A,25A,40A,60A,75A,90A 10A,15A,25A,40A,60A,75A,90A Load Current 10A,15A,25A,40A,60A,75A,90A 10A,15A,25A,40A,60A,75A,90A
Off-state Leakage Current ≤4mA ≤4mA Off-state Leakage Current ≤4mA ≤4mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time ≤10mS ≤10mS On-off Time ≤10mS ≤10mS
General Data General Data
Dielectric Strength 2000VAC 2000VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods Bolt Fixing Bolt Fixing Mounting Methods Bolt Fixing Bolt Fixing
Work Instructions LED LED Work Instructions LED LED
Net Weight 105g 110g Net Weight 105g 110g
Installation
Installation Demensions
Demensions 47(mm) 47(mm) Installation
Installation Demensions
Demensions 47(mm) 47(mm)

Type-selection Type-selection
Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

SSR-10DA 220VAC <5A <1.1KW B-50 80X80(mm) SSR-10DA-H 220/380VAC <5A <1.1KW B-50 80X80(mm)
SSR-15DA 220VAC <7.5A <1.6KW B-50 80X80(mm) SSR-15DA-H 220/380VAC <7.5A <1.6KW B-50 80X80(mm)
SSR-25DA 220VAC <12.5A <2.7KW A-50 80X80(mm) SSR-25DA-H 220/380VAC <12.5A <2.7KW A-50 80X80(mm)
SSR-40DA 220VAC <20A <4.4KW A-50,C-55 80X80(mm) SSR-40DA-H 220/380VAC <20A <4.4KW A-50,C-55 80X80(mm)
SSR-60DA 220VAC <30A <6.6KW C-55 80X80(mm) SSR-60DA-H 220/380VAC <30A <6.6KW C-55 80X80(mm)
SSR-75DA 220VAC <37A <8.1KW C-55,E-50 80X80(mm) SSR-75DA-H 220/380VAC <37A <8.1KW C-55,E-50 80X80(mm)
SSR-90DA 220VAC <41A <9.0KW C-55,E-50 80X80(mm) SSR-90DA-H 220/380VAC <41A <9.0KW C-55,E-50 80X80(mm)

07 08
SSR
Single Phase AC Solid State Relay
SSR
Single Phase AC Solid State Relay

Switching Zero cross Switching Zero cross


Output Two anti-paralleled s Output Bidirectional SCR
S s ingle phase SCR Load Current 10A-90A
Load Current 25A-120A Control Voltage 80-250VAC
Load Voltage 24-380VAC/90-660VAC Load Voltage 90-480VAC
Monitoring Output status Monitoring Output status

Parameters SSR-(15-120)DA SSR-(15-120)DA-H Parameters SSR-(10-90)AA SSR-(10-90)AA


Special Functions Enhanced SCR High Voltage Enhaced SCR Special Functions High Voltage SCR Imported High Voltage SCR
Input Circuit Input Circuit
Control Voltage DC4-32V DC4-32V Control Voltage AC80-250V AC80-250V
Control Current DC6-12mA DC6-12mA Control Current ≤2mA ≤2mA

Output Circuit Output Circuit


Load Voltage Range 24-380VAC 90-660VAC Load Voltage Range 24-380VAC 24-380VAC
Load Current 15A,25A,40A,60A,75A,90A,120A 15A,25A,40A,60A,75A,90A,120A Load Current 10A,15A,25A,40A,60A,75A,90A 10A,15A,25A,40A,60A,75A,90A
Off-state Leakage Current ≤4mA ≤4mA Off-state Leakage Current ≤4mA ≤4mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time ≤10mS ≤10mS On-off Time ≤10mS ≤10mS
General Data General Data
Dielectric Strength 2000VAC 2000VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods Bolt Fixing Bolt Fixing Mounting Methods Bolt Fixing Bolt Fixing
Work Instructions LED LED Work Instructions LED LED
Net Weight 120g 120g Net Weight 105g 110g
Installation
Installation Demensions
Demensions 47(mm) 47(mm) Installation
Installation Demensions
Demensions 47(mm) 47(mm)

Type-selection Type-selection
Mode:Load Voltage Mode:Load Voltage Using Current Using Power Reference Reference Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan
Radiator Fan
SSR-10DA: 220VAC SSR-10DA-H: 220/380VAC <6A <1.3KW B-50 80X80(mm) SSR-10AA 220VAC <5A <1.1KW B-50 80X80(mm)
SSR-25DA: 220VAC SSR-25DA-H: 220/380VAC <15A <3.3KW A-50 80X80(mm) SSR-15AA 220VAC <7.5A <1.6KW B-50 80X80(mm)
SSR-40DA: 220VAC SSR-40DA-H: 220/380VAC <24A <5.2KW C-55 80X80(mm) SSR-25AA 220VAC <12.5A <2.7KW A-50 80X80(mm)
SSR-60DA: 220VAC SSR-60DA-H: 220/380VAC <36A <7.9KW C-55,E-50 80X80(mm) SSR-40AA 220VAC <20A <4.4KW A-50,C-55 80X80(mm)
SSR-75DA: 220VAC SSR-75DA-H: 220/380VAC <45A <9.9KW C-55,C-110 80X80(mm) SSR-60AA 220VAC <30A <6.6KW C-55 80X80(mm)
SSR-90DA: 220VAC SSR-90DA-H: 220/380VAC <54A <11.8KW C-110 80X80(mm) SSR-60AA 220VAC <37A <8.1KW C-55,E-50 80X80(mm)
SSR-120DA: 220VAC SSR-120DA-H: 220/380VAC <70A <15.4KW C-110,E-110 80X80(mm) SSR-60AA 220VAC <41A <9.0KW C-55,E-50 80X80(mm)

09 10
SSR
Single Phase AC Solid State Relay
SSR
Single Phase AC Solid State Relay

Switching Zero cross


Switching Zero cross
Output Bidirectional SCR/Two
Input One or two input
anti-paralleled single phase SCR
Output Two Output
Load Current 10A-90A
Control Voltage 4-32VAC
Control Voltage 80-250VAC
Load Voltage 24-380VAC
Load Voltage 90-480VAC/ 90-660VAC
Monitoring Output status
Monitoring Output status

Parameters SSR-(10-90)AA-H SSR-(15-120)AA-H Parameters SSR2-(10-40)DA SSR-(10-40)DA-2K


Special Functions High Voltage SCR High Voltage Enhaced SCR Special Functions One Input, Two Output Two Input, Two Output
Input Circuit Input Circuit
Control Voltage AC80-250V AC80-250V Control Voltage AC80-250V AC80-250V
Control Current ≤2mA ≤2mA Control Current DC12-32mA DC12-32mA

Output Circuit Output Circuit


Load Voltage Range 90-480VAC 90-660VAC Load Voltage Range 24-380VAC 24-380VAC
Load Current 10A,15A,25A,40A,60A,75A,90A 15A,25A,40A,60A,75A,90A,120A Load Current 10A,15A,25A,40A 10A,15A,25A,40A
Off-state Leakage Current ≤4mA ≤4mA Off-state Leakage Current ≤4mA ≤4mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time ≤10mS ≤10mS On-off Time ≤10mS ≤10mS
General Data General Data
Dielectric Strength 2000VAC 2000VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods Bolt Fixing Bolt Fixing Mounting Methods Bolt Fixing Bolt Fixing
Work Instructions LED LED Work Instructions LED LED
Net Weight 105g 120g Net Weight 270g 270g
Installation
Installation Demensions
Demensions 47(mm) 47(mm) Installation
Installation Demensions
Demensions 70(mm) 70(mm)

Type-selection Type-selection
Load Using Using Reference Reference Mode Load Voltage Using Current Using Power Reference Fan
Mode Voltage Current Power Radiator Fan
SSR2-10DA/SSR2-10DA-2K 220VAC <5AX2 <1.1KWX2 80X80(mm)
SSR-(10A-90A)AA-H 220/380VAC Please refer Page 8,AA is identified as DA
SSR2-15DA/SSR2-15DA-2K 220VAC <6.5AX2 <1.4KWX2 80X80(mm)
SSR-(15A-120A)AA-H 220/380VAC Please refer Page 9,AA is identified as DA
SSR2-20DA/SSR2-20DA-2K 220VAC <8AX2 <1.7KWX2 80X80(mm)

SSR2-40DA/SSR2-40DA-2K 220VAC <8AX2 <1.7KWX2 80X80(mm)

11 12
SSR
Single Phase AC Solid State Relay
SSR
Single Phase AC Solid State Relay

Industry Solid State Relay Industry Solid State Relay


Switching Zero cross Switching Zero cross
Output Two anti-paralleled Output Two anti-paralleled
S Single phase SCR S Single phase SCR
Load Voltage 24-440VAC Load Voltage 24-440VAC
Monitoring Output status Monitoring Output status
Withstand Voltage 2500VAC Withstand Voltage 2500VAC

Parameters SSR-60DA SSR-80/100/120DA Parameters SSR-150/200/250/300DA SSR-350DA


Special Functions Very Good Overload Capacity Very Good Overload Capacity Special Functions Very Good Overload Capacity Very Good Overload Capacity
Input Circuit Input Circuit
Control Voltage DC3-32V DC3-32V Control Voltage DC3-32V DC3-32V
Control Current DC7-12mA DC7-12mA Control Current DC7-12mA DC7-12mA

Output Circuit Output Circuit


Load Voltage Range 24-440VAC 24-440VAC Load Voltage Range 24-440VAC 24-440VAC
Load Current 10A,15A,25A,40A,60A,75A,90A 10A,15A,25A,40A,60A,75A,90A Load Current 150A,200A,250A,300A 350A
Off-state Leakage Current ≤4mA ≤4mA Off-state Leakage Current ≤4mA ≤4mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time ≤10mS ≤10mS On-off Time ≤10mS ≤10mS
General Data General Data
Dielectric Strength 2500VAC 2500VAC Dielectric Strength 2500VAC 2500VAC
Insulation Resistance 1000MΩ@ 500VDC 1000MΩ@ 500VDC Insulation Resistance 1000MΩ@ 500VDC 1000MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods Bolt Fixing Bolt Fixing Mounting Methods Bolt Fixing Bolt Fixing
Work Instructions LED LED Work Instructions LED LED
Net Weight 120g 145g Net Weight 230g 560g
Installation
Installation Demensions
Demensions 80(mm) 80(mm) Installation
Installation Demensions
Demensions 80(mm) 92X38(mm)

Type-selection Type-selection
Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

GYSSR-60DA 220/380VAC <36A <7.9KW L-150 for three sets 80X80(mm) GYSSR-150DA 220/380VAC <85A <18.7KW L-200 for three sets 80X80(mm)

GYSSR-80DA <48A <10.5KW L-150 for three sets ~


80X80(mm) GYSSR-200DA <100A <22KW L-200 for three sets 80X80(mm)
220/380VAC 175-250VAC 220/380VAC

GYSSR-100DA 220/380VAC <60A <13.2KW L-150 for three sets 80X80(mm) GYSSR-250DA 220/380VAC <125A <27.5KW L-250 for three sets 80X80(mm)

GYSSR-120DA 220/380VAC <72A <15.8KW L-150 for three sets 80X80(mm) GYSSR-300DA 220/380VAC <150A <33KW L-300 for three sets 80X80(mm)

GYSSR-350DA 220/380VAC <175A <38.5KW L-400 for three sets 80X80(mm)

13 14
SSR
Three Phase AC Solid State Relay
SSR
Three Phase AC Solid State Relay

Switching Zero cross Switching Zero cross


Output Bidirectional SCR Output Bidirectional SCR
Load Current 10A-90A Load Current 10A-90A
Load Voltage 24-380VAC/90-480VAC Load Voltage 24-380VAC/90-480VAC
Monitoring Output status Monitoring Output status

Parameters SSR3-(10-90)DA SSR3-(10-90)DA-H Parameters SSR3-(10-90)AA SSR3-(10-90)AA-H


Special Functions / High Voltage SCR Special Functions / High Voltage SCR
Input Circuit Input Circuit
Control Voltage DC4-32V DC4-32V Control Voltage AC80-250V AC80-250V
Control Current DC12-32mA DC12-32mA Control Current ≤12mA ≤12mA

Output Circuit Output Circuit


Load Voltage Range 24-380VAC 90-480VAC Load Voltage Range 24-380VAC 90-480VAC
Load Current 10A,15A,25A,40A,60A,75A,90A 10A,15A,25A,40A,60A,75A,90A Load Current 10A,15A,25A,40A,60A,75A,90A 10A,15A,25A,40A,60A,75A,90A
Off-state Leakage Current ≤10mA ≤10mA Off-state Leakage Current ≤10mA ≤10mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time ≤10mS ≤10mS On-off Time ≤10mS ≤10mS
General Data General Data
Dielectric Strength 2000VAC 2000VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods Bolt Fixing Bolt Fixing Mounting Methods Bolt Fixing Bolt Fixing
Work Instructions LED LED Work Instructions LED LED
Net Weight 260g 260g Net Weight 260g 260g
Installation
Installation Demensions
Demensions 90X48(mm) 90X48(mm) Installation
Installation Demensions
Demensions 90X48(mm) 90X48(mm)
Type-selection Type-selection
Mode Load Voltage Using Current Using Power Reference Reference Mode Load Voltage Using Current Using Power Reference Reference
Radiator Fan Radiator Fan
SSR3-10DA/SSR3-10DA-H 380VAC <5AX3 <1.1KWX3 G-80 80X80(mm) SSR3-10AA/SSR3-10AA-H 380VAC <5AX3 <1.1KWX3 G-80 80X80(mm)

SSR3-25DA/SSR3-25DA-H 380VAC <12AX3 <2.7KWX3 G-80,D-120 80X80(mm) SSR3-25AA/SSR3-25AA-H 380VAC <12AX3 <2.7KWX3 G-80,D-120 80X80(mm)
SSR3-40DA/SSR3-40DA-H 380VAC <20AX3 <4.4KWX3 C-110 80X80(mm) SSR3-40AA/SSR3-40AA-H 380VAC <20AX3 <4.4KWX3 C-110 80X80(mm)
SSR3-60DA/SSR3-60DA-H 380VAC <30AX3 <6.6KWX3 C-110 80X80(mm) SSR3-60AA/SSR3-60AA-H 380VAC <30AX3 <6.6KWX3 C-110 80X80(mm)
SSR3-75DA/SSR3-75DA-H 380VAC <37AX3 <8.1KWX3 E-110 80X80(mm) SSR3-75AA/SSR3-75AA-H 380VAC <37AX3 <8.1KWX3 E-110 80X80(mm)
SSR3-90DA/SSR3-90DA-H 380VAC <41AX3 <9KWX3 L-150 80X80(mm) SSR3-90AA/SSR3-90AA-H 380VAC <41AX3 <9KWX3 L-150 80X80(mm)

Note:For SSR3-DA,the load adopts Y-connection, and the center of Y should be connected to Note:For SSR3-AA,the load adopts Y-connection, and the center of Y should be connected to
neutralline. For SSR3-DA -H ,the load adopts Y-connection, and the center of Y can be connected neutralline. For SSR3- A A -H ,the load adopts Y-connection, and the center of Y can be connected
to neutra l line or not. to neutra l line or not.

15 16
SSR
Three Phase AC Solid State Relay
SSR
Three Phase AC Solid State Relay

Switching Zero cross Switching Zero cross


Output Two anti-paralleled Output Bidirectional SCR
s single phase SCR Load Current 10A-90A
Load Current 10A-90A Load Voltage 24-380VAC/90-480VAC
Applied for Inductive Load Monitoring Output status
Monitoring Output status

Parameters SCR3-(25-120)DA SCR3-(25-120)DA-H Parameters SCR3-(25-120)AA SCR3-(25-120)AA-H


Special Functions Enhanced SCR High Voltage EnhancedSCR Special Functions Enhanced SCR High Voltage Enhanced SCR
Input Circuit Input Circuit
Control Voltage DC4-32V DC4-32V Control Voltage AC80-250V DC80-250V
Control Current DC12-32mA DC12-32mA Control Current ≤12mA ≤12mA

Output Circuit Output Circuit


Load Voltage Range 24-380VAC 90-660VAC Load Voltage Range 24-380VAC 90-660VAC
Load Current 25A,40A,60A,75A,120A 25A,40A,60A,75A,90A,120A Load Current 25A,40A,60A,75A,120A 25A,40A,60A,75A,90A,120A
Off-state Leakage Current ≤10mA ≤10mA Off-state Leakage Current ≤10mA ≤10mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time ≤10mS ≤10mS On-off Time ≤10mS ≤10mS
General Data General Data
Dielectric Strength 2000VAC 2000VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods Bolt Fixing Bolt Fixing Mounting Methods Bolt Fixing Bolt Fixing
Work Instructions LED LED Work Instructions LED LED
Net Weight 440g 440g Net Weight 440g 440g
Installation
Installation Demensions
Demensions 90X48(mm) 90X48(mm) Installation
Installation Demensions
Demensions 90X48(mm) 90X48(mm)
Type-selection Type-selection
Mode Load Voltage Using Current Using Power Reference Reference Mode Load Voltage Using Current Using Power Reference Reference
Radiator Fan Radiator Fan
SSR3-25DA/SSR3-25DA-H 380VAC <15AX3 <5.7KWX3 G-80,D-120 80X80(mm) SSR3-25AA/SSR3-25AA-H 380VAC <15AX3 <5.7KWX3 G-80,D-120 80X80(mm)

SSR3-40DA/SSR3-40DA-H 380VAC <24AX3 <9.1KWX3 C-110 80X80(mm) SSR3-40AA/SSR3-40AA-H 380VAC <24AX3 <9.1KWX3 C-110 80X80(mm)
SSR3-60DA/SSR3-60DA-H 380VAC <36AX3 <13.6KWX3 C-110 80X80(mm) SSR3-60AA/SSR3-60AA-H 380VAC <36AX3 <13.6KWX3 C-110 80X80(mm)
SSR3-75DA/SSR3-75DA-H 380VAC <45AX3 <17.1KWX3 E-110 80X80(mm) SSR3-75AA/SSR3-75AA-H 380VAC <45AX3 <17.1KWX3 E-110 80X80(mm)
SSR3-90DA/SSR3-90DA-H 380VAC <54AX3 <20.5KWX3 L-150 80X80(mm) SSR3-90AA/SSR3-90AA-H 380VAC <54AX3 <20.5KWX3 L-150 80X80(mm)
SSR3-120DA/SSR3-120DA-H 380VAC <70AX3 <25.4KWX3 L-150 80X80(mm) SSR3-120AA/SSR3-120AA-H 380VAC <70AX3 <25.4KWX3 L-150 80X80(mm)

Note: For SSR3-DA,the load adopts Y-connection or △- connection, and the center of Y should Note: For SSR3-AA,the load adopts Y-connection or △- connection, and the center of Y should
be connected to neutralline. For SSR3-DA -H ,the load adopts Y-connection or △- connection, and be connected to neutralline. For SSR3-AA -H ,the load adopts Y-connection or △- connection, and
the center of Y can be connectedto neutra l line or not. the center of Y can be connectedto neutra l line or not.

17 18
SSR
Three Phase AC Solid State Relay Three Phase AC Motor Reverse Module
SSR
Features Features
High Current, the rane of load current is wide, and with raditor and fan Control voltage of 10-30VDC is wide range.

Auto-protection for over temperature,if over 50℃, the fan will be Two LED tube display motor rotating direction.

started, and if over 70℃,the circuit will be cut This module have a starting the electricity protection,no surge

Input voltage range suitable for around the world impact,strong anti-interference ability.

Control system, power device and auxiliary power integration


This module have interlocking reverse control circuit to
High precision, temperature controlled accurately
effectively prevent reverse SCR conductting simultaneously.

Technical Data ZHSSR3-(90-600)DA Technical Data TSR3-2/3KDA-H/ZF

Rated Current 90A,120A,150A,200A,250A,300A,350A,400A,500A,600A Load Power 2KW,3KW


Load Voltage 380VAC Load Voltage 380VAC
Control Voltage 4-32VDC Control Voltage 10-30VDC
Control Current DC20-95mA Control Current 10-30mA
Mounting Methods Bolt Fixing On-off Time ≥300mS
Weight 520g
Connection Example
A Connection Example
B
C

+ ~ Negative
-
Positive

~ Rotate Rotate
Control Voltage
10-30VDC
Temperature Controller 70℃
+ +
+ ~ -
PV
- ~ A
Rv
SV 70℃
+ +
FUSE
AT ON OFF ALM1 ALM2
~ B
Rv
-


- ~

SET

R
XMTA-2000 FUSE
50℃ Rv
220VAC C
FUSE

Type-selection
Positive Rotate Instruction Negative Rotate Instruction
Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

ZHSSR3-90DA 220VAC <7.5A <1.6KW G-80,D-120 80X80(mm)


ZHSSR3-1200DA 220VAC <12.5A <2.7KW G-80,D-120 80X80(mm) Type-selection
ZHSSR3-150DA 220VAC <20A <4.4KW C-110,D-120 80X80(mm) Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

ZHSSR3-200DA 220VAC <37A <8.1KW C-110 80X80(mm) TSR-2KDA-H/ZF 380VAC Three phase Three phase G-80,D-120 80X80(mm)
<5.3A <2KW
ZHSSR3-250DA 220VAC <40A <8.8KW C-110,E-110 80X80(mm)
Three phase Three phase
ZHSSR3-150DA <20A <4.4KW C-110,D-120 TSR-3KDA-H/ZF 380VAC <7.9A <3KW G-80,D-120 80X80(mm)
220VAC 80X80(mm)
ZHSSR3-200DA 220VAC <37A <8.1KW C-110 80X80(mm)
ZHSSR3-250DA 220VAC <40A <8.8KW C-110,E-110 80X80(mm)

19 20
SSR
Single Phase DC Motor Module
SSR
Single Phase DC Motor Module

DC Motor Module DC Motor Module


Input 5 inputs or 8 outputs Application
Output 5 outputs or 8 outputs Widely used for textile machine, chemical
Mounting C45 rail machinery, food machine and the other
Application 24V solenoid valve occasion which need control on-off state or
stepless speed regulation for DC motor.

Parameters ST5-5DD ST8-5DD Parameters SSR-10/30/75DD DTS-10/25/40DD


Special Functions 5 Inputs, 5 Outputs 8 Inputs, 8 Outputs Special Functions Switch for DC Motor Speeding Regulator for DC Motor
Input Circuit Input Circuit
Control Voltage DC24V Com-anode or com-cathode DC24V Com-anode or com-cathode Control Voltage DC3-32V DC0-5V
Control Current ≤2mA ≤2mA Control Current DC2-15mA DC4-20mA

Output Circuit Voltage Bias / DC12V


Load Voltage Range DC24V DC24V Current Bias / ≤20mA
Load Current 5AX5 5AX5 Output Circuit
Off-state Leakage Current ≤4mA ≤4mA Load Voltage Range DC5-60V,5-300VDC DC0-24V
On-state Voltage ≤1.5V ≤1.5V Load Current 10A,30A,75A 10A,25A,40A
On-off Time ≤10mS ≤10mS Off-state Leakage Current ≤4mA /

General Data On-state Voltage ≤1.5V /

Dielectric Strength 2000VAC 2000VAC On-off Time ≤10mS /

Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC General Data


Ambient Temperature -20~+70℃ -20~+70℃ Dielectric Strength 1500VAC 1500VAC
Mounting Methods C45 Rail C45 Rail Insulation Resistance 500MΩ@ 500VDC 100MΩ@ 500VDC
Work Instructions Ambient Temperature -20~+70℃ -20~+70℃
LED LED
Net Weight 60g 80g Mounting Methods Bolt Fixing Bolt Fixing
Work Instructions LED /
Connection Diagram
Net Weight 105g 145g
Installation
Installation Demensions
Demensions 47(mm) 80(mm)

DTS-10/25/40A-24V Diagram
V IN
Vb voltage
bias +5VDC 4 1 (V)

phase shift trigger circuit


Red
5
Orange
10K/2W Potentiometer
4
+ Yellow +
DC0-24V 3
4-20mA,0-5V
- Green - 2
+ Load
Blue 1
3
mains locking terminal 0 V OUT
12 24
(V)
21 22
SSR
Solid State Voltage Regulator
SSR
Solid State Voltage Regulator

Manual Voltage Regulator


Manual Voltage Regulator
Output Two anti-paralleled
Output Bidirectional SCR
S single phase SCR
Control Mode External Potentiometer
Control Mode External Potentiometer
S to manual adjust voltage
S to manual adjust voltage
Load Voltage 24-380VAC
Load Voltage 90-480VAC

Parameters SSR-(10-90)VA SSR-(10-90)VA Parameters SSR-(10-90)VA-H SSR-(10-90)VA-H


Special Functions / Imported SCR Special Functions Enhanced SCR High Voltage Enhanced SCR
Input Circuit Input Circuit
Control Mode 500KΩ Potentiometer @220V 500KΩ Potentiometer @220V Control Mode 500KΩ@220V 1MΩ@380V 500KΩ@220V 1MΩ@380V

Output Circuit Output Circuit


Load Voltage Range 24-380VAC 24-380VAC Load Voltage Range 90-480VAC 90-480VAC
Load Current 10A,15A,25A,40A,60A,75A,90A 10A,15A,25A,40A,60A,75A,90A Load Current 10A,15A,25A,40A,60A,75A,90A 15A,25A,40A,60A,75A,120A
Off-state Leakage Current ≤4mA ≤4mA Off-state Leakage Current ≤4mA ≤4mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time / / On-off Time / /

General Data General Data


Dielectric Strength 2000VAC 2000VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods PCB or Bolt Fixing Bolt Fixing Mounting Methods PCB or Bolt Fixing Bolt Fixing
Work Instructions / / Work Instructions / /
Net Weight 105g 110g Net Weight 105g 120g
Installation Demensions Type-selection
Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan Load Using Using Reference Reference
Mode Voltage
SSR-10VA 220VAC <5A <1.1KW B-50 80X80(mm) Current Power Radiator Fan
SSR-15VA 220VAC <7.5A <1.6KW B-50 80X80(mm) SSR-(10A-90A)VA-H 220/380VAC Please refer Page 8,AA is identified as DA
SSR-25VA 220VAC <12.5A <2.7KW A-50 80X80(mm)
SSR-(15A-120A)VA-H 220/380VAC Please refer Page 9,AA is identified as DA
SSR-40VA 220VAC <20A <4.4KW A-50,C-55 80X80(mm)
SSR-60VA 220VAC <30A <6.6KW C-55 80X80(mm)
SSR-75VA 220VAC <37A <8.1KW C-55,E-50 80X80(mm)
SSR-90VA 220VAC <41A <9.0KW C-55,E-50 80X80(mm)

23 24
SSR
Solid State Voltage Regulator
SSR
Solid State Voltage Regulator

Single Phase AC Solid State Relay Manual Voltage Regulator Single Phase AC Solid State Relay
Manual Voltage Regulator Board
Integrated design,small size, simple intallation and
Output Bidirectional SCR
wiring connection.
Control Mode Built-in potentiometer
It widely used for room lighting dimming, environment
S to manual adjust voltage
temperature control, electrical switchgear cubicle and
Load Voltage 24-250VAC
the other automation control fields.

Parameters SSR-16VA-A SSR-16VA-B Parameters SSR-10/15VA SSR-15VA


Special Functions Output Voltage is 0V once startup Output Voltage is 24V once startup Special Functions Integrated Design Room Lighting Dimming
Input Circuit Input Circuit
Control Mode Potentiometer:500KΩ/ 2W Potentiometer:500KΩ/ 2W Control Mode Potentiometer:500KΩ/ 2W Potentiometer:500KΩ/ 2W

Output Circuit Output Circuit


Load Voltage Range 24-250VAC 24-250VAC Load Voltage Range 24-380VAC 24-380VAC
Load Current 16A 16A Load Current 10A,15A 15A
Off-state Leakage Current ≤4mA ≤4mA Off-state Leakage Current ≤4mA ≤4mA
On-state Voltage ≤1.5V ≤1.5V On-state Voltage ≤1.5V ≤1.5V
On-off Time / / On-off Time / /

General Data General Data


Dielectric Strength 2000VAC 2000VAC Dielectric Strength 2000VAC 2000VAC
Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ -20~+70℃ Ambient Temperature -20~+70℃ -20~+70℃
Mounting Methods Suken Mounting Suken Mounting Mounting Methods Suken Mounting Suken Mounting
Work Instructions / / Work Instructions / /
Net Weight 72g 72g Net Weight 125g 50g
Output Voltage Waveform Installation Demensions

V OUT V OUT
(V) (V)
220 220
176 176
132 132
88 88
44 44
0 V IN 0 V IN
250KΩ 500KΩ 250KΩ 500KΩ
(V) (V)

Note:These two products is a voltage regulator board plus upper panel, you can Note:Manual voltage regulator for room lighting dimming is a voltage regulator board
customize upper panel according to your preference. plus upper panel, you can customize upper panel according to your preference.

25 26
SSR
Solid State Voltage Regulator
SSR
Solid State Voltage Regulator

Random Solid State Relay Random Solid State Relay


External pulse signal, this module applied with our patented products Rapid response,when the effective control signal is applied across

ZKG-I and DPC-I can be used for temperature control of forming input, the load of SSR-DA-P will be conducted at once.SSR-DA-P can

machine or other resistive load.We have hold very big marketing share control shift phase pulse to adjust load voltage convinently, which be
used for temperature regulation,adjusting luminance and the other
in China and the other nation, and will be more and more.
resistive load or inductive load.

Parameters SSR-(10-90)DV Parameters SSR-25DV


Special Functions Very Good Stabilizing Voltage Function Special Functions Very Good Stabilizing Voltage Function

Input Circuit Input Circuit


Control Mode Temperature controller,voltage regulator Control Mode Temperature controller,voltage regulator

Output Circuit Output Circuit


Load Voltage Range 175-250VAC Load Voltage Range 175-250VAC
Load Current 10A,15A,25A,40A,60A,75A,90A Load Current 10A,15A,25A,40A,60A,75A,90A
Off-state Leakage Current ≤4mA Off-state Leakage Current ≤4mA
On-state Voltage ≤1.5V On-state Voltage ≤1.5V

General Data General Data


Dielectric Strength 2000VAC Dielectric Strength 2000VAC
Insulation Resistance 500MΩ@ 500VDC Insulation Resistance 500MΩ@ 500VDC
Ambient Temperature -20~+70℃ Ambient Temperature -20~+70℃
Mounting Methods Suken Mounting Mounting Methods Suken Mounting
Net Weight 105g Net Weight 105g
Output Voltage Waveform Output Voltage Waveform

SSR-DA-P Series(Temperature controller control output%)

L L
Power AC220V LOAD LOAD
Power AC24-380V
N
FUSE N
FUSE
SCR VOLTAGE REGULATOR
Thermocouple
PV
1 ~ 24~380VAC

~ 2
PV
R 1 ~ 24~380VAC ~ 2
220VAC
SV R
Solid State Relay SV
SSR-25DV

25A
Solid State Relay
INPUT

P 4 G T1 3
AT ON OFF ALM1 ALM2
+ Voltage SSR-40DA-P 40A


ZKG-I INPUT
Pulse 4 _ + 3
G T N L
SET 《 《 - Output
4~8VDC

R
XMT-2000

27 28
SSR
Single Phase SCR Voltage Regulator
SSR
Single Phase SCR Voltage Regulator

Summary
Application
Single phase SCR voltage regulator includes synchronous phase detecting circuit, Forming machine,lamp,temperature
sawtooth wave circuit, input control regulating circuit, reference circuit, phase shift Regulation,industrial s furnace,oven,
compare circuit,output trigger circuit, and stabilized voltage supply which provides electrical switchgear cubicle and the
power to these circuits , etc. When control voltage is changed from low to high, in the other automation control fields.
inner of this module will generate triggering pulse between 180 and 0 relative to Output Voltage: 0-220V/220-0V

network voltage, after photoelectric isolation,then A and G output terminal can trigger
corresponding SCR to realize shift phase voltage regulation. Parameters SSR-10/25/40LA-A/B SSR-10/25/40LA
Features Special Functions 0-5V,4-20mA,10K/2W potentiometer 4-20mA

Input Circuit
Ultra small and thin,adopt SMT technics.
Control Mode 0-5V,4-20mA,10K/2W potentiometer 4-20mA
screw hold-down connection and bolt fixing mounting,very easy to use.
Adopt photoelectric isolation, you can manually control voltage by potentiometer or Voltage Bias A:DC5V B:DC12V /
automatically by voltage signal and current signal. Current Bias ≤30mADC /
The trigger adopts single wide pulse trigger mode, which is suitable for inductive or Off-state Leakage Current / ≤4mA
resistive load. On-state Voltage / ≤1.5V
LED indication for working state
Output Circuit
Built-in RC absorption circuit
Load Voltage Range A:220-0VAC B:0-220VAC 0-220VAC
Waveform Diagram Load Current 10A,15A,25A,40A 10A,15A,25A,40A

About working waveform of single phase SCR voltage regualtor,we take 0-5V input as an General Data
example.When control voltage is changed from 0V to 5V, the module will generate Dielectric Strength 2000VAC 2000VAC
triggering pulse between 180 and 0 relative to network voltage, then this triggering Insulation Resistance 500MΩ@ 500VDC 500MΩ@ 500VDC
pulse make us get different output voltage waveform.
Ambient Temperature -20~+70℃ -20~+70℃
0-Uoff is shutoff area,there is no ouput in main circuit.
Uoff-Uon:basic linear area,load voltage increased linearly with control signal. Mounting Methods Bolt Fixing Bolt Fixing
Uon-5V:fully conducting state, load voltage is grids voltage. Work Instructions / /
Net Weight 115g 115g
Output Voltage Waveform
Pulse Duty Factor
Grids
1
Voltage

Output
Wide 0.5
Pulse
Output Ucon
Voltage Uoff 2.5V Uon 5V
Uoff:0.7 0.2V Uon:4.3 0.2V

29 30
SSR
Single Phase SCR Voltage Regulator
SSR
Single Phase SCR Voltage Regulator

Features Features

Very-hot sale Products,low cost but high qualtiy Enhanced Voltage Regulator, especially for inductive load.

The new modular design meet IP protection stardards, CE certification. The new modular design meet IP protection stardards, CE certification.

Input voltage range suitable for around the world Input voltage range suitable for around the world

Modularized, high voltage resistant, more safe and reliable Modularized, high voltage resistant, more safe and reliable Vacuum

Control system, power device and auxiliary power integration Welding technique, good quality and long service life

High precision, temperature controlled accurately High precision, temperature controlled accurately

Technical Data SCR-(15-90)LA(Active) Technical Data SCR-(25-120)LA-II

Rated Current 15A,25A,40A,75A,90A Rated Current 25A,40A,75A,90A , 120A


Operation Frequency 50Hz/60Hz Operation Frequency 50Hz/60Hz
Rated Voltage Single phase 175-265VAC Rated Voltage Single phase 175-265VAC
Output Mode Phase Output Output Mode Phase Output
Control Signal 4-20mA,0-5V,0-10V,2-10KΩPotentiometer@0-5V Control Signal 4-20mA,0-5V,0-10V
Use Environment Less than 45℃,humidity less than 90%RH Use Environment Less than 45℃,humidity less than 90%RH
Connection Example Connection Example

L 220VAC
LOAD L N
220VAC FUSE
N Temperature Controller
FUSE
PV

SV
4-20mA
Temperature sensor AT ON OFF ALM1 ALM2 0-5VD + INPUT
~ ~
L N



0-10VDC


SET
Single Phase
INPUT SCR Voltage Regulator
Temperature Controller
R
XMTA-2000
175-265VAC
OUT SCR-75LA-II

-
IN 220VAC
~ ~
Single Phase OUTPUT
SCR Voltage Regulator
SCR-75LA PV
0-5V INPUT
4-20mA INPUT SV

+ 5V CON COM
AT ON OFF ALM1 ALM2

LOAD

SET

R
XMTA-2000

Temperature Sensor
4-20mA,0-5VD,0-10VDC
Power work instruction Load work instruction

Type-selection Type-selection
Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

SCR-15LA 220VAC <7.5A <1.6KW G-80,D-120 80X80(mm) SCR-25LA-II 220VAC <15A <3.3KW G-80,D-120 80X80(mm)

SCR-25LA 220VAC <12.5A <2.7KW G-80,D-120 80X80(mm) SCR-40LA-II 220VAC <24A <5.2KW C-110,D-120 80X80(mm)

SCR-40LA 220VAC <20A <4.4KW C-110,D-120 80X80(mm) SCR-75LA-II 220VAC <45A <9.9KW C-110 80X80(mm)

SCR-75LA 220VAC <37A <8.1KW C-110 80X80(mm) SCR-90LA-II 220VAC <52A <11.4KW C-110,E-110 80X80(mm)
SCR-90LA 220VAC <40A <8.8KW C-110,E-110 80X80(mm) SCR-120LA-II 220VAC <60A <13.2KW L-150,E-110 80X80(mm)

31 32
SSR
Single Phase SCR Voltage Regulator
SSR
Single Phase SCR Voltage Regulator

Features Features

High voltage and enhanced voltage regulator, can resist 305-456VAC Heavy current and weak current is partially completely separated,
control safety
The new modular design meet IP protection stardards, CE certification. High voltage and high current resistance

Input voltage range suitable for around the world The new modular design meet IP protection stardards, CE certification.
Input voltage range suitable for around the world
Modularized, high voltage resistant, more safe and reliable Vacuum
Modularized, high voltage resistant, more safe and reliable Vacuum
Welding technique, good quality and long service life
Welding technique, good quality and long service life
High precision, temperature controlled accurately High precision, temperature controlled accurately

Technical Data SCR-(25-120)LA-II Technical Data SCR-(25-120)LA-WY

Rated Current 25A,40A,75A,90A,120A Rated Current 25A,40A,75A,90A , 120A


Operation Frequency 50Hz/60Hz Operation Frequency 50Hz/60Hz
Rated Voltage Single phase 305-456VAC Rated Voltage Single phase 175-265VAC
Output Mode Phase Output Output Mode Phase Output
Control Signal 4-20mA,0-5V,0-10V Control Signal 4-20mA,0-5V,0-10V
Use Environment Less than 45℃,humidity less than 90%RH Use Environment Less than 45℃,humidity less than 90%RH
Connection Example Connection Example

L 380VAC
L 220VAC FUSE
L N
FUSE
Temperature Controller Temperature Controller
PV PV

SV SV

4-20mA + INPUT
AT ON OFF
4-20mA + INPUT
~ ~ AT ON OFF ALM1 ALM2 0-5VD ~ ~

+
ALM1 ALM2
+

0-5VD L N L N



0-10VDC



SET 0-10VDC INPUT


Single Phase
SET
INPUT
Single Phase
SCR Voltage Regulator R
SCR Voltage Regulator
R
XMTA-2000 XMTA-2000

SCR-75LA-WY

-
- SCR-75LA-II -
~ ~
-

~ ~ OUTPUT
OUTPUT

LOAD LOAD

Temperature Sensor
Temperature Sensor
Power work instruction Load work instruction Power work instruction Load work instruction

Type-selection Type-selection
Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan

SCR-15LA-H 380VAC <7.5A <1.6KW G-80,D-120 80X80(mm) SCR-15LA-WY 220VAC <7.5A <1.6KW G-80,D-120 80X80(mm)

SCR-25LA-H 380VAC <12.5A <2.7KW G-80,D-120 80X80(mm) SCR-25LA-WY 220VAC <12.5A <2.7KW G-80,D-120 80X80(mm)

SCR-40LA-H 380VAC <20A <4.4KW C-110,D-120 80X80(mm) SCR-40LA-WY 220VAC <20A <4.4KW C-110,D-120 80X80(mm)

SCR-75LA-H 380VAC <37A <8.1KW C-110 80X80(mm) SCR-75LA-WY 220VAC <37A <8.1KW C-110 80X80(mm)
SCR-90LA-H 380VAC <40A <8.8KW C-110,E-110 80X80(mm) SCR-90LA-WY 220VAC <40A <8.8KW C-110,E-110 80X80(mm)

33 34
SSR
Single Phase SCR Voltage Regulator Single Phase SCR Voltage Regulator
SSR
Features Features

Manually or automatically generate pulse DC voltage which can be Protective cover to prevent electrical shock hazard.

stepless controlled,adjustable range is wide,output precision is high. The radiator and fan make sure a very nice heat emission.

Full isolated design,dielectric withstanding voltage is over 2000VAC High voltage and high current resistant.

This module adopts SMT technics and DCB ceramic substrate,few Modularized, high voltage resistant, more safe and reliable.
peripheral connection. Control system, power device and auxiliary power integration.

Application:electroplating,electrowelding,DC motor,and so on. High precision, temperature controlled accurately.

Technical Data SCR-(25-120)LA-ZLI Technical Data AYSCR-(25-75)LA-DX

Load Current 25A,40A,75A,90A,120A Rated Current 25A,40A,75A


Load Voltage 175-265VAC Rated Voltage Single Phase 220VAC
Control Voltage DC:0-5V,4-20mA,10kΩ/ 2W potentiometer Operation Frequency 50/60Hz
Output Mode Phase Output Output Mode Phase Output
Work Instructions Red Led: power supply Green Led:output voltage variation Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10KΩ
Weight 440g potentiometer, control signal should select 0-5VDC

Connection Example Connection Example


L N
220VAC 220VAC
L
N Pulse Duty Factor
FUSE NBF NBF

1
COM

~ ~ ~ - FU Wiring Instruction
of Control Circuit
0-5V,4-20mA 0.5
CON

Voltage Regulating
Rectifier Module
+ M + -
SCR-40LA-ZL
+5V

+ ~ ~
-
External Signal Input
4-20mA Ucon
DC0-5V
DC0-10V 4mA Uoff 10mA Uon 20mA
M + -
LOAD

Uoff:4mA + 0.5mA
Adjustable Area:Uoff-Uon
Power work instruction Load work instruction
Uon:18-20mA

Type-selection 1.The main circuit adopts single phase 220VAC input.


2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall
Mode Load Voltage Using Current Using Power Reference Radiator Reference Fan
D not be locked tightly, or SCR will be burned by terminal heating.
SCR-15LA-ZL 220VAC <9A <1.9KW G-80,D-120 80X80(mm) 3.During the use of the module, you need to match proper radiator, and heat conducting silicon
D grease should be coated between radiator and SCR backboard. If the module power is very big,
SCR-25LA-ZL 220VAC <15A <3.3KW G-80,D-120 80X80(mm) D please consider wind or water cooling.
SCR-40LA-ZL 220VAC <24A <5.2KW C-110,D-120 80X80(mm) 4.Please use semi-conductive fast fuse for load over current.
5.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to
SCR-75LA-ZL 220VAC <45A <9.9KW C-110 80X80(mm) D maximum output. The adjustable area is about 4.5-18mA, the closed area is 4-4.5mA, the wide-
SCR-90LA-ZL 220VAC <52A <11.4KW C-110,E-110 80X80(mm) D open area is 18-20mA.
SCR-120LA-ZL 220VAC <60A <13.2KW L-150,E-110 80X80(mm)

35 36
Single Phase SCR Voltage Regulator
SSR Single Phase SCR Voltage Regulator
SSR
Features Features

Protective cover to prevent electrical shock hazard. Protective cover to prevent electrical shock hazard.

The radiator and fan make sure a very nice heat emission. The radiator and fan make sure a very nice heat emission.

High voltage and high current resistant. High voltage and high current resistant.

Modularized, high voltage resistant, more safe and reliable. Modularized, high voltage resistant, more safe and reliable.

Control system, power device and auxiliary power integration Control system, power device and auxiliary power integration

High precision, temperature controlled accurately built in fast fuse for over current and short-circuit protection

Technical Data HNSCR-(90-150)LA-DX Technical Data FUSCR-(25-75)LA-DX

Rated Current 90A,120A,150A Rated Current 200A,250A,300A


Rated Voltage Single Phase 220VAC Rated Voltage Single Phase 220VAC
Operation Frequency 50/60Hz Operation Frequency 50/60Hz
Output Mode Phase Output Output Mode Phase Output
Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10KΩ Control Voltage 4-20mA, 0-5VDC, 0-10VDC Manual Adjustment:2-10KΩ
potentiometer, control signal should select 0-5VDC potentiometer, control signal should select 0-5VDC

Connection Example Connection Example


N N
220VAC 220VAC
L L
Pulse Duty Factor Pulse Duty Factor
NBF NBF NBF NBF

1 1

FU Wiring Instruction FU Wiring Instruction


of Control Circuit of Control Circuit
0.5 0.5
M + - M + -

External Signal Input External Signal Input


4-20mA Ucon 4-20mA Ucon
DC0-5V DC0-5V
DC0-10V 4mA Uoff 10mA Uon 20mA DC0-10V 4mA Uoff 10mA Uon 20mA
M + - M + -

Uoff:4mA + 0.5mA Uoff:4mA + 0.5mA


Adjustable Area:Uoff-Uon Adjustable Area:Uoff-Uon
Uon:18-20mA Uon:18-20mA

1.The main circuit adopts single phase 220VAC input. 1.The main circuit adopts single phase 220VAC input. Auxiliary power must be synchronous with
2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall m main power.
D not be locked tightly, or SCR will be burned by terminal heating. 2.SCR is a product with big current, please keep in mind that terminals (R.S.T) and (U.VW) shall
3.During the use of the module, you need to match proper radiator, and heat conducting silicon m not be locked tightly, or SCR will be burned by terminal heating.
D grease should be coated between radiator and SCR backboard. If the module power is very big, 3.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to
D please consider wind or water cooling. m maximum. The adjustable area is about 4.5-18mA, the shutoff area is 4-4.5mA and the fully
4.Please use semi-conductive fast fuse for load over current. m conducting area is 18-20mA.
4.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was
5.When control signal changes from low to high, AC voltage of the load can be adjustable from 0v to
m blown, the yellow LED was showing, right now please check the load circuit short or not or partial
D maximum output. The adjustable area is about 4.5-18mA, the closed area is 4-4.5mA, the wide-
m discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse
D open area is 18-20mA. m of the same rating. Please never hop up the fuse ampere.

37 38
Single Phase SCR Voltage Regulator
SSR Single Phase SCR Voltage Regulator
SSR
Summary
Patented Products for Forming Machine, Blowing Machine,Sheet Machine or Other N N
Power AC220V LOAD Power AC220V LOAD
Resistive Loads
L L
Our products based on single-chip computer as the core are designed to adjust load FUSE FUSE
voltage continuously by phase-shift trigger. Due to the use of deep voltage negative SCR VOLTAGE REGULATOR SCR VOLTAGE REGULATOR

feedback, our products have exceptional stabilized voltage property, well linearity PV
K2
PV
K2

control function, and can minimize the effects of electric network fluctuation. G2 G2

Our products have hold a most marketing share in China and the other nation, and will SV K1 SV K1


G1


G1
become more and more.


P P

Features N L N L

Stabilized voltage property, well linearity control function, can minimize the effects Fig.3 Fig.4

of electric network fluctuation.


Small, light, clear reading and low cost
Have high accuracy, good shock-resistant, good reliability.
Respond quickly to change in set voltage.
Have pushbutton switches which are operationally simple and reliable.

Important Specifications
Adjustment Range 0-220VAC
Working Voltage AC220V 50Hz(the other voltage can be customized)
Control Output Mode Control SSR-DV module
Control one bidirectional SCR Fig.5 Fig.6

Control one SKKT or two anti-paralleled single phase SCR 1.Please connect wire between output, feedback, power, ground wire and load according to
Installing Mode Panel type above Fig. The phase of load must correspond with power of voltage regulator (i.e.
synchronism), or it will lead to damage of voltage regulator.
Environment Conditons Maximum relative humidity 85%, Temperature 0-50℃
2.Press up arrow or down arrow from the panel until required voltage (i.e. “SV” value), then you
Connection Diagram will find it is synchronous changing between “SV” and “PV” value.
L 3.If you press “P” key at any time, our SCR voltage regulator will stop output untill you press “P”
N
Power AC220V LOAD Power AC220V LOAD key again.
L 4.Fig.5 and Fig.6 is integrated output,it is very convinient.But Fig.6 have full power output
N
FUSE FUSE function
SCR VOLTAGE REGULATOR SCR VOLTAGE REGULATOR

PV PV V PV
1 ~ 24~380VAC

~ 2 220V
R

SV SV
Solid State Relay

SSR-25DV SV Value

25A

P
INPUT
110V

P 4 G T1 3 PV Value

G T1 N L
G T1 N L
SV
0V 110V 220V
Electrify Waveform Operating Waveform
Fig.1 Fig.2 Safty Notice
39 40
SSR
Single Phase SCR Voltage Regulator
SSR
Single Phase SCR Voltage Regulator

Product Selection Table Product Selection Table


Opening Connection Opening Connection
Appearance Type Dimensions Load Power Control Type Appearance Type Dimensions Load Power Control Type
Size Diagram Size Diagram

Control two
Any power Control Any power anti-paralleled
ZKG-I 48x48x90 45x45 SSR-DV Fig.1 ZKD-IIIA 72x72x120 67x67 Fig.3 Fig.4
will do will do single phase
Module SCR or a SKKT

Any power Control a Must not be Intergration


ZKG-IIB 48x48x107 45x45 bidirectional Fig.2 ZKG-5 48x48x110 45x45 larger 500W control load Fig.5
will do
SCR directlly,but
SCR can not
be split

Intergration
Any power Must not be control load Fig.5
ZKG-IIIB 48x48x107 45x45 ZKG-62 48x48x112 45x45
will do larger 500W directlly,but
SCR can be
split

Intergration
Any power Control a Must not be control load Fig.5
ZKG-IIA 48x48x75 45x45 Fig.2 ZKG-64 48x48x112 45x45
will do bidirectional larger 500W directlly,but
SCR SCR can be
split

Control two Intergration


Any power anti-paralleled Fig.3 Fig.4 Must not be control load
ZKG-IIIA 48x48x75 45x45
will do single phase DVC-4 48x48x75 45x45 larger 1000W directlly,and Fig.6
SCR or a SKKT have full power
output function

Control a
ZKD-IIA 72x72x120 67x67 Any power Fig.2 ZKC-36 280x160x65 151x199.5 Any power Control 36 way
bidirectional Fig.1
will do will do SSR-DV
SCR

41 42
SSR
Digital Power Control Series Digital Power Control Series
SSR
Features Features

DPC-I adopts zero-cross triggering to control power,which can be used Intergrated output,very convinient,and buitl-in radiator,but the
for temperature control of forming machine, blowing machine or other maximum power is 800W
resistance loads with SSR-DV Be fit for forming machine, blowing machine and the other resistive load
There is no stabilized voltage output There is stabilized voltage output
Have good shock-resistant, small overall dimensions, light weight, high External full-power manual control, you can warm up quickly
performance-price ratio After start-up you can set the time of full power output
Have full power output and you can set the time of full power output Auto memory function, the stored program will never get lost

Technical Data DPC-I-M Technical Data DPC-II-M

Working Voltage 150-220VAC 50/60Hz Working Voltage 150-220VAC 50/60Hz


Adjustment Range 0-99% Adjustment Range 0-99%

Phase-shifting Angle 0-160 Output Stability Coefficient 1.5%

Output Mode Phase Output Phase-shifting Angle 0-160
Use Environment Less than 45℃,humidity less than 85%RH Output Mode Phase Output
Overall Dimensions 52x52x35(mm) Use Environment Less than 45℃,humidity less than 85%RH
Opening Size 46x45(mm) Overall Dimensions 52x52x35(mm)

Connection Example Opening Size 46x45(mm)

Connection Example

N L
Power AC220V LOAD
L N
Load Voltage
FUSE

DPC
OUT 220V
% 218V
1 ~ 24~380VAC

~ 2

Solid State Relay

SSR-25DV 25A
OUT F.P. N L OUT F.P. N L
P 4 G
INPUT

T1 3 OUT F.P. N L OUT F.P. N L

LOAD

LOAD
DIGITAL POWER CONTROL

LOAD

LOAD
G FP N L
FUSE FUSE
Output Power FUSE FUSE

External Switch 0% 99%100%


S1

Remark: Remark:
1.DPC-I have three states,non power output(OF),full power output(HP) and set percentage power 1.DPC-II-M have three states,non power output(OF),full power output(HP) and set percentage
output . These three work state have auto memory function after electrifying the meter and can be power output . These three work state have auto memory function after electrifying the meter and
circularly changed by “P” key. can be circularly changed by “P” key.
2.DPC-I voltage regulator and the load must be power synchronism, if not SCR will be damaged 2.“S1” switch is external manual switch of full power output control. When “SI” is closed, DPC-III-M
3.You can use an external switch to control voltage regulators which are in the same phase. If they output full power, except “OF” and “HP” state. This function can be optional according to practical
are not in the same phase, you can not do that. application.
3.When multi DPC-II-M were used, DPC-II-M in the same phase can share one external control
switch of full power output.

43 44
Digital Power Control Series
SSR SSR
Three Phase SCR Power Regulator

Features
Features
Be fit for forming machine, blowing machine and the other resistive load
Economy three phase thyristor power regulator,enhance the product value.
with our specialized solid state relay SSR-AVA
The new modular design meet IP protection stardards, CE certification.
There is stabilized voltage output
Input voltage range suitable for around the world
External full-power manual control, you can warm up quickly
Latest technology:small size, stable output power, good cooling effect.
After start-up you can set the time of full power output
Input mode:4-20mA/0-5V/0-10V/Potentiometer
Auto memory function, the stored program will never get lost
Output mode: phase output

Technical Data
Technical Data SCR3-LA(Economy Type)
Working Voltage 150-220VAC 50/60Hz
Rated Current 25A,40A,75A,90A,120A
Adjustment Range 0-99%
Operation Frequency 50Hz/60Hz
Output Stability Coefficient 1.5%

Rated Voltage Three phase 380VAC FAN220VAC
Phase-shifting Angle 0-160
Output Mode Phase Output
Output Mode Phase Output
Control Signal 4-20mA/0-5V/0-10V/Potentiometer
Use Environment Less than 45℃,humidity less than 85%RH
Use Environment Less than 45℃,humidity less than 90%RH
Overall Dimensions 52x52x46(mm)
Dimension(mm) 100X110X145(WXLXH)
Opening Size 46x45(mm)
Installation Dimension(mm) 90X80(WXL)
Connection Example
Connection Example
A
N B
Power AC220V LOAD A
L C Three Phase Control S ignal
N B
FUSE 380VAC
C PV
DPC
OUT DPC
FUSE LOAD
DPC
FUSE LOAD
DPC
FUSE LOAD N SV 100%

%
1 ~ 24~380VAC

~ 2
OUT OUT OUT AT ON OFF ALM1 ALM2

4-20mA
% % %


R

《 80%


Solid State Relay 1 ~ 24~380VAC ~ 2 1 ~ 24~380VAC ~ 2 1 ~ 24~380VAC ~ 2 SET
  

P
SSR-25AVA 25A
INPUT
R

Solid State Relay


R

Solid State Relay


R

Solid State Relay


A1 B1 C1 0-5VDC R
XMTA-2000

4 G T1 3

P SSR-25AVA 25A
P SSR-25AVA 25A
P SSR-25AVA 25A SCR3-LA N
0-10VDC
INPUT INPUT INPUT

DIGITAL POWER CONTROL


4 G T1 3 4 G T1 3 4 G T1 3 COM - 60%
DIGITAL POWER CONTROL DIGITAL POWER CONTROL DIGITAL POWER CONTROL CON +
G FP N L
G FP N L G FP N L G FP N L 40%
A2 B2 C2
S1

20%

Temperature 0%
Remark: sensor 4mA 20mA
1.DPC-III-M have three states,non power output(OF),full power output(HP) and set percentage power
output . These three work state have auto memory function after electrifying the meter and you can be Type-selection
circularly changed by “P” key.
2.“S1” switch is external manual switch of full power output control. When “SI” is closed, DPC-III-M Mode Load Voltage Maximum Using Maximum Using Reference Reference
output full power, except “OF” and “HP” state. This function can be optional according to practical
Current Power Radiator Fan
SCR3-25LA 380VAC 12.5AX3 2.7KWX3 G-80,D-120 80X80(mm)
application.
3.When multi DPC-III-M were used, DPC-III-M in the same phase can share one external control SCR3-40LA 380VAC 20AX3 4.4KWX3 C-110 80X80(mm)
switch of full power output. SCR3-75LA 380VAC 37.5AX3 8.2KWX3 C-110,E-110 80X80(mm)
SCR3-90LA 380VAC 45AX3 9.9KWX3 L-150,E-110 80X80(mm)
SCR3-120LA 380VAC 60AX3 13.2KWX3 L-150,L-200 80X80(mm)

45 46
SSR
Three Phase SCR Power Regulator
SSR
Three Phase SCR Power Regulator

Features Features

Simple three phase four-wire thyristor power regulator,simple installation With automatic protective function,built-in fast fuse
and wirre connection Protective cover to prevent electrical shock hazard
The new modular design meet IP protection stardards, CE certification. Input voltage range suitable for around the world
Input voltage range suitable for around the world Vacuum welding technique,good quality and long service life
Latest technology:small size, stable output power, good cooling effect. Latest technology:small size, stable output power, good cooling effect.
Input mode:4-20mA/0-5V/0-10V/Potentiometer Input mode:4-20mA/0-5V/0-10V/Potentiometer
Output mode: phase output Output mode: phase output

Technical Data SCR3-KW-4(Simple Type) Technical Data PRSCR-LA


Rated Current 40A,75A Rated Current 40A,75A
Operation Frequency 50Hz/60Hz Operation Frequency 50Hz/60Hz
Rated Voltage Three phase 380VAC FAN220VAC Rated Voltage Three phase 380VAC FAN220VAC
Output Mode Phase Output Output Mode Phase Output
Control Signal 4-20mA/0-5V/0-10V/Potentiometer Control Signal 4-20mA/0-5V/0-10V/Potentiometer
Use Environment Less than 45℃,humidity less than 90%RH Use Environment Less than 45℃,humidity less than 90%RH
Dimension(mm) 100X140X145(WXLXH) Dimension(mm) 126X130X152(WXLXH)
Installation Dimension(mm) 90X80(WXL) Installation Dimension(mm) 116X90(WXL)

Connection Example Connection Example


A
A B Three Phase
Three Phase Control S ignal
B C 380VAC Control S ignal
380VAC N 100%
C PV
PV
R S T
N SV 100% SV

80%
AT ON OFF ALM1 ALM2 SCR POWER REGULATOR AT ON OFF ALM1 ALM2

4-20mA


80% 《


SET

SET

0-5VDC
R
XMTA-2000
R
XMTA-2000 FU FU FU
60%
LINE AC380V N
0-10VDC
COM - 60%
SCR POWER REGULATOR
CON +
4-20mA 40%
SCR3-KW-4 !
LOAD
MODE:

MAIN SOURCE:
PHASE ANGLE

220VAC
ZERO CROSSING

380VAC
N
N
0-5VDC
-
40% INPUT:

CURRENT:
4-20mA

40A 75A
1-5VDC

90A 120A
INPUT

+ COM - 0-10VDC
U V W CON + 20%
U V W + 5V
20%
0%
Temperature
Temperature 0% sensor 4mA 20mA

sensor 4mA 20mA

Remark:
Remark: 1.The main circuit adopts three-phase four-wire input without requirement for phase sequence.
1.The main circuit adopts three-phase four-wire input without requirement for phase sequence. 2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be
2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be locked tightly, or SCR will be burned by terminals’ heating.
locked tightly, or SCR will be burned by terminals’ heating. 3.There is a fast fuse built in SCR for over current and short circuit protection.Please replace with
3.Module protection:please use semi-conductive fast fuse for over current protection. fuse of equivalent specification when the fast fuse is burned out,and don't use the one with higher
4.When Y connection is used for three-phase load,the center of Y should be connected with zero fusing ampere.
line,if not,relative equilibrium of three-phase is required. 4.When Y connection is used for three-phase load,the center of Y should be connected with zero
5.During use of module, when the load power is more than 15KW, it’s best to be equipped with proper line,if not so,relative equilibrium of the three-phase is required.
radiator, and heatconducting silicon grease should be coated between radiator and SCR backboard 5.During the use of module,when the load power is big or the radiating condition is bad,please
,and cool by wind. consider wind cooling.
47 48
Three Phase SCR Power Regulator
SSR Three Phase SCR Power Regulator
SSR
Features Features

Multipurpose LED indication for working condition Multipurpose LED indication for working condition
With automatic protective function,built-in fast fuse With automatic protective function,built-in fast fuse
Adjustable for maximum and minimum output Adjustable for maximum and minimum output
Input voltage range suitable for around the world Input voltage range suitable for around the world
Input mode:4-20mA/0-5V/0-10V/Potentiometer Input mode:4-20mA/0-5V/0-10V/Potentiometer
Linear phase shift control circuit, with good stability and high precision Linear phase shift control circuit, with good stability and high precision
Modularized, high voltage resistant, more safe and reliable Modularized, high voltage resistant, more safe and reliable

Technical Data AYSCR-LA Technical Data J3-SCR-LA


Rated Current 25A,40A Rated Current 75A,90A,120A
Operation Frequency 50Hz/60Hz Operation Frequency 50Hz/60Hz
Rated Voltage Three phase 380VAC FAN220VAC Rated Voltage Three phase 380VAC FAN220VAC
Output Mode Phase Output Output Mode Phase Output
Control Signal 4-20mA/0-5V/0-10V/Potentiometer Control Signal 4-20mA/0-5V/0-10V/Potentiometer
Use Environment Less than 45℃,humidity less than 90%RH Use Environment Less than 45℃,humidity less than 90%RH
Dimension(mm) 112X135X165(WXLXH) Dimension(mm) 75A,90A:110X230X165(WXLXH) 120A:110X280X165(WXLXH)
Installation Dimension(mm) 101X95(WXL) Installation Dimension(mm) 100X160(WXL )

Connection Example Connection Example


A A
B Three Phase B Three Phase
C 380VAC Control S ignal C 380VAC Control S ignal
R S T PV R S T PV

SV SV

SCR POWER REGULATOR


UP
AT ON OFF ALM1 ALM2
M + - SCR POWER REGULATOR
UP
AT ON OFF ALM1 ALM2
M + -


《 《


MODE: PHASE ANGLE ZERO CROSSING SET MODE: PHASE ANGLE ZERO CROSSING SET
MAIN SOURCE: 220VAC 380VAC
R
BIAS BIAS MAIN SOURCE: 220VAC 380VAC
R
BIAS BIAS
XMTA-2000 XMTA-2000
INPUT: 4-20mA 1-5VDC
Internal Control INPUT: 4-20mA 1-5VDC
Internal Control
CURRENT: 25A 40A 75A 90A
power signal CURRENT: 25A 40A 75A 90A
power signal
Adjust voltage input Adjust Adjust voltage input Adjust
minimum DC5V 4-20mA maximum minimum DC5V 4-20mA maximum
FU FU FU FU FU FU
output DC0-5V output output DC0-5V output
PL
DC0-10V PL
DC0-10V

4-20mA 4-20mA
IN IN

OUT OUT

BIAS
M + -
BIAS
FB

0-5VDC PL Power supply AC380V state BIAS


M + -
BIAS
FB

0-5VDC PL Power supply AC380V state


INPUT
0-10VDC INPUT
0-10VDC
IN Control signal input state IN Control signal input state
U V W U V W

Temperature OUT Output state Temperature OUT Output state


sensor sensor
FB Fast fuse state or phase-missing state FB Fast fuse state or phase-missing state

Remark: Remark:
1.The main circuit adopts three-phase three-wire input without requirement for phase sequence. 1.The main circuit adopts three-phase three-wire input without requirement for phase sequence.
2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be 2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be
locked tightly, or SCR will be burned by terminals’ heating. locked tightly, or SCR will be burned by terminals’ heating.
3.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was 3.There is a fast fuse built in SCR for over current and short-circuit protection. If the fast fuse was
blown, the yellow LED is showing, right now please check the load circuit short or not or partial blown, the yellow LED is showing, right now please check the load circuit short or not or partial
discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse of discharge, etc. After troubleshooting, please open the panel to replace the blown fuse with a fuse of
the same rating. Please never hop up the fuse ampere. the same rating. Please never hop up the fuse ampere.
4.For Y connection load, the center can not be to zero line, or SCR will lose control. 4.For Y connection load, the center can not be to zero line, or SCR will lose control.If three phase is
5.During use of module, when the load power is big or the radiating condition is bad, please consider unbalanced, you can choose my company’s three-phase four-wire products.
wind cooling
49 50
Three Phase SCR Power Regulator
SSR Three Phase SCR Power Regulator
SSR
Features Features

Multipurpose LED indication for working condition Novel structure,high quality


With over temperature protective function With over temperature protective function
Built-in fast fuse with over current protective function Multipurpose LED indication for working condition
Input voltage range suitable for around the world Adjustable for maximum and minimum output
Input mode:4-20mA/0-5V/0-10V/Potentiometer Applied for high power load
Novel structure,high efficiency,high quality Input voltage range suitable for around the world
Modularized, high voltage resistant, more safe and reliable Input mode:4-20mA/0-5V/0-10V/Potentiometer

Technical Data HNSCR-LA Technical Data HNSCR-LA-ZQ

Rated Current 40A,75A,90A Rated Current 75A 90A 120A 150A 200A 250A
Operation Frequency 50Hz/60Hz Dimension(mm) WXLXH 170X260X250 170X310X250 170X360X250

Rated Voltage Three phase 380VAC Installation Dimension(mm) 150X150 ( WXL) 150X200( WXL) 150X250( WXL)

Output Mode Phase Output Operation Frequency 50Hz/60Hz


Control Signal 4-20mA/0-5V/0-10V/Potentiometer Rated Voltage Three phase 380VAC(three-phase three-wire)
Use Environment Less than 45℃,humidity less than 90%RH Output Mode Phase Output
Dimension(mm) 140X200X150(WXLXH) Control Signal 4-20mA/0-5V/0-10V/Potentiometer

Installation Dimension(mm) 130X170(WXL) Use Environment Less than 45℃,humidity less than 90%RH
Connection Example
Connection Example
A A
B Three Phase B Three Phase
C 380VAC C 380VAC
N Control S ignal N Control S ignal
R S T PV R S T PV

UP
SV

A C 1 A C2 M + - E3 E2 E1 UP
SV
A C 1 A C2 M + - E3 E2 E1
AT ON OFF ALM1 ALM2 AT ON OFF ALM1 ALM2
SCR POWER REGULATOR SCR POWER REGULATOR


《 《


SET SET

FU FU FU R
XMTA-2000 FU FU FU R
XMTA-2000
AC220V TIC Input If you do not use
AC220V TIC Input If you do not use Auxiliary power signal potentiometer,E2
Auxiliary power signal potentiometer,E2 and E3 must be shorted
and E3 must be shorted
MODE: PHASE ANGLE ZERO CROSSING MODE: PHASE ANGLE ZERO CROSSING

MAIN SOURCE: 220VAC 380VAC MAIN SOURCE: 220VAC 380VAC

INPUT: 4-20mA 1-5VDC INPUT: 4-20mA 1-5VDC

CURRENT: 25A 40A 75A 90A CURRENT: 25A 40A 75A 90A
PL Auxiliary Power supply AC220V state
CONTROL
PL
IN

OUT

FB
4-20mA PL Auxiliary Power supply AC220V state CONTROL
PL
IN

OUT

FB
4-20mA
+ -
0-5VDC + -
0-5VDC IN Control signal input state
A C 1 A C2

U
M

V
E3 E2

W
E1

0-10VDC IN Control signal input state A C 1 A C2

U
M

V
E3 E2

W
E1

0-10VDC
OUT Output state
OUT Output state
Temperature Temperature FB Phase-missing state
sensor FB Fast fuse state or phase-missing state sensor

Remark: Remark:
1.The main circuit adopts three-phase four-wire input without requirement for phase sequence. The main circuit adopts three-phase four-wire input without requirement for phase sequence.
2.For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be For SCR is a product with a high current, please keep in mind that terminals of R,S,T and U,V,W be
locked tightly, or SCR will be burned by terminals’ heating. locked tightly, or SCR will be burned by terminals’ heating.
3.There is a fast fuse built in SCR for over current and short-circuit protection.Please replace with When Y connection is used for three-phase load,the center of Y should be connected with zero line,if
fuse of equivalent specification when the fast fuse is burned out,and don't use the one with higher not so,relative equilibrium of the three-phase is required.
fusing ampere. When the temperature of radiator exceeds 75 °C,the modules will stop working automatically,and
4.When Y connection is used for three-phase load,the center of Y should be connected with zero
only the power indicating light is bright on the moment.
line,if not so,relative equilibrium of the three-phase is required.

51 52