RM STORE GENERAL NOTES:-
(1 ) STANDARD NOTES / DRAWINGS SUPPLIED
WITH DRAWINGS SHALL BE FOLLOWED
Schedule of R. C. C. Column ( Use M : 25, Fe : 500 ) THROUGH OUT THE PROJECT.
Column upto Plinth Level Stirrups (2 ) STRUCTURAL DRAWINGS SHALL BE READ
IN ACCORDANCE WITH RELEVANT
Column No ARCHITECTURAL DRAWING / DETAILS.
Size Steel Spacing Type
(3 ) ALL FORM WORK & REINFORCEMENT
D SHALL BE CHECKED & VERIFIED FROM US
3,4,23,24 610 X 1060 26 No 0 16 mm 0 8 @ 100 to 150 c/c BEFORE CONCRETING.
B
(4 ) USE CONCRETE GRADE M20 OR M25 AND
STEEL GRADE Fe415 OR Fe500 AS
2,5,6,7,8,9,10,11,22,25,26, SPECIFIED.
27,28,29,30,31 610 X 1060 26 No 0 16 mm 0 8 @ 100 to 150 c/c B M-15 MIX MEANS 1:2:4
M-20 MIX MEANS 1:1½:3
M-25 MIX MEANS 1:1:2
D
1,12,21,32 400 X 920 16 No 0 16 mm 0 8 @ 100 to 150 c/c (5 ) DO NOT MEASURE THE DRAWING, READ
B THE DIMENSIONS.
D
13,14,19,20 COLUMN & FOUNDATION NOTES:-
450 X 550 14 No 0 16 mm 0 8 @ 100 to 150 c/c B
15,16,17,18
(1 ) THIS STRUCTURE IS DESIGNED FOR
GROUND + UPPER FLOORS.
Schedule of R. C. C. Footing ( Use M : 25 & Fe : 500 ) (2 ) CONSIDERED SOIL BEARING CAPACITY
( S.B.C. ) = 20 T / M ² .
P. C. C. R. C. C. Reinforcement (3 ) COLUMN REDUCTIONS SHALL BE
Column No 125 mm Thk. FOLLOWED IF SHOWN IN DRAWINGS.
Bottom Part
( M :15 ) D // To short span // To long span
LxB (4 ) ALL CONCRETING TO BE DONE USING
CONCRETE MACHINE MIXER &
3,4,23,24 4100 X 3400 3800 X 3100 750 0 16 @ 150 c/c 0 16 @ 150 c/c VIBRATOR ONLY.
2,5,6,7,8,9,10,11,22,25,26, (5 ) STRIPPING TIME OF FORM WORK FOR
4100 X 3400 3800 X 3100 750 0 16 @ 150 c/c 0 16 @ 150 c/c ALL VERTICAL SIDES OF FOOTING &
27,28,29,30,31 COLUMNS SHOULD BE 24 HOURS.
1,12,21,32 4200 X 3450 3900 X 3150 750 0 16 @ 150 c/c 0 16 @ 150 c/c
(6 ) FOOTING DEPTH SHALL BE TO LEVEL OF
13,14,19,20 PERMANENTLY STABILIZED STRATA OF
3500 X 3500 3200 X 3200 600 0 12 @ 150 c/c 0 12 @ 150 c/c HARD MURRUM OR YELLOW SOIL AND IN
15,16,17,18
NO CASE , IT SHALL BE LESS THAN 1.5 MT.
BELOW THE EXISTING GROUND LEVEL.
(7 ) P.C.C. SHALL BE EITHER IN M15 GRADE
CONCRETE ( UNLESS OTHERWISE
TYPICAL DETAIL OF FOOTING SPECIFIED ).
(8 ) CLEAR CONCRETE COVER
( a ) FOOTING BOTTOM & SIDE - 50 MM
Ground Beam ( b ) COLUMN SIDES ( 9” WIDE ) - 40 MM
Column (9 ) LAPPING OF MAIN BARS. COMPRESSION
Ground level BARS = 50 x d ; WHERE, d = BAR'S DIA.
A A TENSION BARS = 60 x d. OR ELSE
SPECIFIED.
L
Stirrups
Steel // L
(10 ) COLUMN BARS SHALL BE GIVEN AN
Bottom Part Steel // B L - BEND OF 45d ( DIAMETER OF BAR )
AND SHALL BE EXTENDED IN TO THE
Steel // B Top Part FOOTING COMPLETELY.
Bottom Part D
P.C.C.(1: 1.5 : 3)
B .E . ( CIVIL ) , MIE , FIV
L
M.E. ( STRUCTURE ) AMIE
B Steel // L Chartered Civil Engineer, Govt. Approved Valuer
7/1434 , Near Purna Mata Temple, Khatriwad, Junathana, Navsari - 396445
TEL : +91 63529 35403, Cell : +91 98252 72401, Email :
[email protected] Plan of Footing Section - AA Date 28/10/20 Title :
Detail Of Column & Footing
Drg. No 02
Drg. by Tarun Owner : Atul Ltd. ( RM STORE ) Scale :
Chkd. by