Company Presentation

DRY CONSTRUCTION CONTRACTORS


INTRODUCTION

Innovative Vastunirman is a trendsetting and transformative dry construction


contractor, offering pan India services. We take pride in our problem-solving
capability that is underpinned by innovative and simplified construction practices.
Our team of consultants and specialists are on a mission to reshape the
construction solutions ecosystem with innovation, vigor, and operational
excellence.
Continuous innovation and novel ideas help us grow fast and provide new and
better products.. We offer end-to-end services i.e. from design, procurement to
installation across the breadth of our product portfolio. Our key services include
but are not limited to drywalls, fire-rated products, toilet cubicles and ceilings.

WWW.INNOVASTU.COM
WHO WE ARE

DNA
Enjoying the creation of simplified construction by Passion and Optimism

Mission
To serve the industry with simplified construction products & solutions to optimize
resources & deliver operational excellence by adding value to all stakeholders of the
industry

Vision
It is our endeavor to become the most preferred world class brand in construction
solution and services

WWW.INNOVASTU.COM
OUR SERVICES

Drywalls Ceilings Fire Rated Services Other Products

Normal Drywall Metal False Fire Rated Toilet Cubicles


Fire Rated Ceiling Ceilings Geofoam
Drywall Grid False Ceiling Fire Rated Drytech Toilet
Acoustic Drywall Gypsum False Drywalls Block
Moisture Ceiling Fire Rated LGSF
Resistant Drywall Secondary Grid Enclosures Skirting For
Impact Resistant Fire Rated Drywalls
Drywall Column Cladding Louvres
Drywall Fire Rated Glass
Enclosures Fire Curtains &
Windows

WWW.INNOVASTU.COM
CASE STUDY – TYRE MANUFACTURING PLANT, CHAKAN

Wall between sub-station & plant, 1 hour fire rated, 2 Hour Fire
Rated Wall
Wall designed within 220 mm thickness
Wall height 18 mtr – 9 mtr & length 100 mtr
Roll up shutter fabrication designed to fit in within wall thickness
Drytech Insulation clip to hold the glasswool in position
Total area done with drywall 32,500 Sqm Within 10 months

WWW.INNOVASTU.COM
HIGH-RISE DRYWALL

WWW.INNOVASTU.COM
HEIGHT OF WALL FROM UP TO 15 MTR & 18 MTR EXPANSION JOINT IN WALL

WWW.INNOVASTU.COM
PERFECTLY FIT GLASS WOOL INSULATION IN POSITION WITH INSULATION CLIP

WWW.INNOVASTU.COM
LENGTH OF WALL FROM PLANT SIDE

WWW.INNOVASTU.COM
2HR FIRE RATED WALL - HEIGHT OF WALL 13.5 MTR & LENGTH OF WALL 165 MTR

WWW.INNOVASTU.COM
CASE STUDY - CUMMINS INDIA, PUNE

Drywall for engine assembly line


180 mtr x 10.3 mtr & 13 mtr x 24 mtr
Completed in 75 days with 2 coats of gypsum top coat
Gantries of 10 tons from both sides of the long wall
All walls designed for 25 kg per sqm lateral pressure
Total wall area 3200 sqm

WWW.INNOVASTU.COM
LONGITUDINAL VIEW - ASSEMBLY PLANT WITH DRYWALLS ON SIDES & GANTRY OF 10 TONS

WWW.INNOVASTU.COM
DOOR OPENING OF RAPID ACTION DOOR SIZE 4 MTR X 4 MTR

WWW.INNOVASTU.COM
WINDOW OPENINGS IN DRYWALLS

WWW.INNOVASTU.COM
CONNECTION BETWEEN STRUCTURAL STEEL & DRYWALL

WWW.INNOVASTU.COM
WORKING WITH ACCESS PLATFORM

WWW.INNOVASTU.COM
VIEW OF THE PAINTED DRYWALL

WWW.INNOVASTU.COM
CASE STUDY : JSW SEVER FIELD INDIA PVT LTD, BELLARY

Wall between plant & plant office area.


Wall is 60 Db sound rated
Wall height 11 mtr - 9 mtr & length 100 mtr
Decision of the wall came in after finishing the Mezzanine floor.
Wall area 1150 sq. mtr. finished in 40 days.

WWW.INNOVASTU.COM
LENGTH OF WALL FROM PLANT SIDE

WWW.INNOVASTU.COM
CASE STUDY: DRYWALL AT GSK ,KOLAR2016-2017

Drywall :
2hr fire rated wall - 3975 sqm
Normal Drwall -10,000 sqm
Moisture resistant Drywall - 539 sqm
Drywall cladding –1778 sqm
Toilet area drywall - 2863 sqm

False Ceiling :
Gypsum Ceiling
Grid Ceiling
Metal Ceiling

Secondary Grid :

WWW.INNOVASTU.COM
CASE STUDY: DRYWALL AT GSK ,KOLAR2016-2017

Louvers :
Scope of work: 1461 SQM
Strip louvers with 40% opening ratio.
Max. height of work is 14mtrs.
Designed for external local wind pressure

Fire Rated Window :


120 MIN. Fire rated integrity (120 EW) Fully Glazed
6mm thk. schott pyran s glass

WWW.INNOVASTU.COM
2HR FIRE RATED WALL

WWW.INNOVASTU.COM
NORMAL GYPSUM DRYWALL

WWW.INNOVASTU.COM
CLADDING DRYWALL

WWW.INNOVASTU.COM
TOILET AREA DRYWALL

WWW.INNOVASTU.COM
GRID CEILING

WWW.INNOVASTU.COM
GRID CEILING

WWW.INNOVASTU.COM
LOUVERS

WWW.INNOVASTU.COM
FIRE RATED WINDOW

WWW.INNOVASTU.COM
CASE STUDY– BKT, BHUJ, GUJARAT

False ceiling with tee grid and PVC laminated gypsum tiles with
bubble insulation on top.
Secondary Grid – 30, 000 sqm (Secondary grid system for services
such as electrical light fittings, and cable trays designed for 25 kg
per sqm dead load)
Drywalls up to height of 11 mtr – Quantity 8000 Sqm
Drywall up to the length of 255 Rmt
Self standing drywalls up to height of 5.5 mtr – Quantity 2500 Sqm

WWW.INNOVASTU.COM
GRID CEILING WITH PVC LAMINATED GYPSUM TILE

WWW.INNOVASTU.COM
LENGTH OF WALL 255 MTR WITH HEIGHT OF 11 MTR

WWW.INNOVASTU.COM
SELF STANDING DRYWALL (WITHOUT TOP SUPPORT) UPTO 5.5 MTR

WWW.INNOVASTU.COM
CASE STUDY – L'OREAL INDIA, CHAKAN

Client wants wall without any support at the top


They did not want any column beam structure of the wall to be seen
Wall should be 2 hour fire rated
We created wall self standing anchored only into RCC Tremix floor
for 12 mtr height & 20 mtr 2 bays of wall, designed based on to
generic documents
Wall area 450 sqm, wall thickness 510 mm
Total work finished in 33 days

WWW.INNOVASTU.COM
FABRICATION OF GI FRAMING IN PROCESS

WWW.INNOVASTU.COM
ERECTED FRAMING IN POSITION

WWW.INNOVASTU.COM
DOUBLE LAYER BOARDING WITH FIRE RATED EXPANSION JOINT

WWW.INNOVASTU.COM
FINISHED WALL WITH PAINTING

WWW.INNOVASTU.COM
CASE STUDY : L'OREAL INDIA 15 MTR HIGH SELF STANDING WALL, CHAKAN

WWW.INNOVASTU.COM
CASE STUDY - SCA HYGEINE, RANJHANGAON

2 hour fire rated wall - Quantity 2150 Sqm


Normal drywall for office area
Length of normal drywall : 100m
Height of normal drywall : 4m

WWW.INNOVASTU.COM
FIRE RATED DRYWALL MAXIMUM HEIGHT OF WALL UP TO 13MTR

WWW.INNOVASTU.COM
NORMAL DRYWALL

WWW.INNOVASTU.COM
CASE STUDY – PHOENIX MARKETCITY, ALL INDIA

Delivered and Installed toilet cubicles all across India


Retained customer since 2011
various colour options and qualities provided

WWW.INNOVASTU.COM
TOILET CUBICLES

WWW.INNOVASTU.COM
URINAL PARTITIONS & PD DOORS

WWW.INNOVASTU.COM
CASE STUDY : EXTERNAL WALL AT NEW HOLLAND, CHAKAN

Client’s Requirement:
Client wants to expand his factory later on in future. So the current
external wall can be used as an Internal wall.
Solution we provided:
We designed the wall currently as External wall of 1750 Sq. Mtr. and
upto height of 14 mtrs. considering the Wind Pressure of 110Kg per
Sq. Mtr. with external colour coated sheet cladding to perform in the
external atmosphere.In future, this sheet cladding can be removed
and wall will be ready as Finished Internal wall, in case of expansion.

WWW.INNOVASTU.COM
EXTERNAL WALL UPTO 14 MTR. HEIGHT SEMI FINISHED DRYWALL WITH EXTERNAL SHEETING

WWW.INNOVASTU.COM
FINISHED EXTERIOR WALL WITH SHEET CLADDING

WWW.INNOVASTU.COM
CASE STUDY: MOISTURE RESISTANT DRYWALL AT ADLER MEDIEQUIP, RATNAGIRI

Client’s Requirement:
Client wanted MS Fabrication with Calcium Silicate Board in partition
with moisture resistance.

Solution we provided:
Drywall of 1100 Sqm upto 5 Mtr height
We converted the requirement of Calcium Silicate Board to the
equivalent product consisting of Moisture resistant Board.

WWW.INNOVASTU.COM
MOISTURE RESISTANT DRYWALL

WWW.INNOVASTU.COM
CASE STUDY : FIRE RATED DRYWALL PARTITION AT ASHOKA HOSPITAL, NASHIK

Client’s Requirement:
Client required Paper less drywall having fire resistance and acoustic
value of 44STC

Solution we provided:
We designed 1hr fire rated wall for 4m height using galvalume and
USG fiber rock board.
Total quantity of work: 5831 sqm

WWW.INNOVASTU.COM
HOSPITAL DDRYWALLS

WWW.INNOVASTU.COM
CASE STUDY : INCLINED & CURVED PROFILE WALLS AT CUMMINS MFH, PUNE

Client’s Requirement:
Client required double skin inclined and curved profile walls

Solution we provided:
We designed 620 sqm of double skin partition of 70° inclined wall
and curved profile wall with drywall system having capacity to take
60kg/m2 loading of screen and LED TV.

WWW.INNOVASTU.COM
INCLINED WALLS

WWW.INNOVASTU.COM
CURVED WALLS

WWW.INNOVASTU.COM
CASE STUDY – NIVEA INDIA PRIVATE LIMITED, GUJARAT

T-grid ceiling with PVC tile - Quantity 5800 sqm


Secondary substructure - Quantity 5800 sqm (Secondary grid
designed for 40 kg per sqm including dead load)
2 Hour Fire Rated Wall

WWW.INNOVASTU.COM
PVC TILE WITH 600X600 GRID

WWW.INNOVASTU.COM
SECONDARY SUBSTRUCTURE

WWW.INNOVASTU.COM
2 HOUR FIRE RATED WALL

WWW.INNOVASTU.COM
CASE STUDY - TATA CUMMINS LIMITED, PHALTAN

2 hour Fire curtain up to maximum opening of 5.5 x 4.2 mtr


2 hour Fire rated window - Quantity 90 Sqm

WWW.INNOVASTU.COM
2 HOUR FIRE RATED WINDOW WITH FIRE RESISTANT DRYWALL

WWW.INNOVASTU.COM
2 HOUR FIRE RATED CURTAIN

WWW.INNOVASTU.COM
CASE STUDY – WESTEND MALL, PUNE

Drytech Geofoam is a light weight fill to reduce dead loads on structures,


solving structural fill challenges. Geofoam is tested under IS 516.

Client’s Requirement:
Client wanted a light weight filling material to fill above the basement slab as it was
not designed for siporex or murum filling.

Solution we provided:
We supplied 20 Kg/m3 density Geofoam which had a compression strength of 4400
kg/m3

WWW.INNOVASTU.COM
GEOFOAM FILLING

WWW.INNOVASTU.COM
CASE STUDY: FIRE RATED CURTAIN AT CUMMINS TECHNICAL CENTRE, PUNE

Client’s Requirement:
Client required 2hr fire rated partition above the existing engine test
cells.
Site constraints:
Lot of labor and material movement at the working location

Solution we provided:
We designed 2hr fire rated curtain (120min integrity only) along with
necessary skeleton fabrication.

WWW.INNOVASTU.COM
2 HOUR FIRE RESISTANT CURTAIN

WWW.INNOVASTU.COM
2 HOUR FIRE RATED WINDOW

WWW.INNOVASTU.COM
CASE STUDY : 3M INDIA PVT LTD, RANJHANGAON

Shop Offices in plant 650 sqm


Cold formed GI steel fabricated skeleton of Light gauge steel
sections installed at site over RCC Tremix floor & structure steel
frame work.
All internal & external walls in wet area gypsum plasterboard.
Drywall is designed for 20 kg/sqm lateral pressure.
All doors and windows in aluminum.

WWW.INNOVASTU.COM
ENCLOSURE WITH STRUCTURAL FRAMING

WWW.INNOVASTU.COM
CASE STUDY : CUMMINS QSK SHOP OFFICES , PHALTAN

Shop Offices in plant- Quantity 720 sqm


Cold formed GI steel fabricated skeleton of Light gauge steel sections installed at
site over RCC Tremix floor.
All internal & external walls in gypsum plasterboard.
External walls and few internal walls are designed as load bearing walls.
Structure is designed for 40 kg/sqm loading for roof with coil coated sheeting as
roof.
Internally mineral fibre false ceiling
All doors and windows in aluminum.
All services done inside such as electrical, HVAC, fire & smoke.

WWW.INNOVASTU.COM
CUMMINS QSK SHOP OFFICES IN THE PLANT

WWW.INNOVASTU.COM
FINISHED SHOP OFFICE

WWW.INNOVASTU.COM
CASE STUDY : DRYTECH TOILET BLOCK AT GOETHE INSTITUTE, PUNE

Client’s Requirement: External Toilet Block

Solution we provided: We executed the work with Light Gauge Steel Structure with
Cement Board Cladding, replacing conventional work in Brick and mortar.

WWW.INNOVASTU.COM
LIGHT GUAGE STEEL FRAMING DRYTECH TOILET BLOCK

WWW.INNOVASTU.COM
FINISHED DRYTECH TOILET BLOCK

WWW.INNOVASTU.COM
CASE STUDY : 19MM THICK SINGLE LAYERED ENCLOSURE AT TCL, PHALTAN

Client’s Requirement:
Client wanted to office enclosure with MS-Framing with double layered boarding
along with Fire and Moisture Resistance.

Solution we provided:
We designed the wall with 19mm thick Single layered shaft liner Board instead of
Double Boarding; providing Fire and Moisture Resistance.

WWW.INNOVASTU.COM
GI FRAMING & BOARDING WITH 19MM THICK SINGLE LAYERED SHAFT LINER BOARD

WWW.INNOVASTU.COM
BOARDING & FINISHED ENCLOSURE

WWW.INNOVASTU.COM
CASE STUDY: G + 1 ENCLOSURE AT HIRSCHVOGEL, RANJHANGAON

Client’s Requirement:
Client required Conventional Enclosure in the plant.

Solution we provided:
We designed Live Load at 500Kg per Sq. mtr. upto a height of 6 mtrs. Office Enclosure
designed and built in LGSF instead of conventional construction

WWW.INNOVASTU.COM
BOARDING IN PROGRESS

WWW.INNOVASTU.COM
FINISHED ENCLOSURE

WWW.INNOVASTU.COM
C
CASE STUDY: NIC, PUNE

Client’s Requirement:
Client required False Flooring for their server room.

Solution we provided:
We supplied and installed False Flooring with the UDL 1600 kg/sqmt.

WWW.INNOVASTU.COM
FALSE FLOORING AT NIC DATA CENTRE

WWW.INNOVASTU.COM
FEW OF OUR CLIENTS

Kasturi Housing - Metal False Ceiling.


Corning Technologies India Pvt. Ltd.– 2 Hour Fire Rated Drywall
Faber India - 2 Hour Fire Rated Drywall
Shimizu Corporation India Pvt. Ltd
Shapoorji Pallonji Co.Ltd
VW India Pvt.Ltd.- 2 Hour Fire Rated Drywall
Delhi International Airport – metal, gypsum & mineral fiber ceilings
Soktas Spinning Mills, Kolhapur – Ceiling & Drywall
Balkrishna Tire Industries - Drywall, Self Standing Drywall, Secondary Grid, PVC
Grid Ceiling

WWW.INNOVASTU.COM
CONTACT US

Innovative Vastunirman Pvt. Ltd.


Address: “Anurag Apartment”, Plot No-79,
Right Bhusari Colony,
Paud Road, Kothrud,
Pune - 411 038.
T: +91 - 20 - 25280115 / 116
M: +91 - 9552523596
E: [email protected] | [email protected]
W: www.innovastu.com

WWW.INNOVASTU.COM

You might also like