Capacitive Proximity Switch
Capacitive Proximity Switch
APPLICATION No backlash.
l
1
EXPLANATION OF TECHNICAL TERMS SUPPLY VOLTAGE
For DC switches, a filtered and ripple-free regulated
SENSING DISTANCE power supply should be used and for AC switches the
This is the distance between the target and the sensing supply should be EMI free as far as possible
face at witch the switch operates. This is usually specified
SWITCHING HYSTERISIS
considering a standard object for each type of switch.
This is a differential between “Switch ON” and “Switch
OFF” point of the switch. This is adjusted within limits
5% to 15% of the specified sensing distance
OUTPUT LOGIC
The output switching element (either a Transistor or
Thyristor) can be normally in Closed (ON) or Open
(OFF) condition.
The output logic has to be very carefully selected
considering the application requirement.
For specific applications, the inductive switches above
STANDARD OBJECTS M24 size are available with built-in electromagnetic
For different types of switches following objects are relay to give a potential free output contact for
considered as standard while specifying the sensing gap switching external loads. The output logic in this case
Inductive - MS disc of min. 1 mm thick and size same can be NO, NC and CO (Change-Over) type. Switches
as sensing face. with a specific output logic such as latched type.
Oscillator type are available on request.
Capacitive - Water/MS of min.10mmthick and size
same as sensing face. LOAD CURRENT
Optical - White paper of 100x100 mm size. This is the maximum current, which the switch can
Magnetic - Ferrous Material. either sink or source to the external load.
Metal
2
GENERAL SPECIFICATIONS (Standard Switch)
Supply Voltage : 10 to 30 V DC Brown
Reverse Polarity Protection : Provided for all models Connection Diagram For
2 Wire DC Switch
Blue
Short Circuit Protection : Provided for
sizes M8 & above
Operating Temperature : -25°C to +70°C
Indication : Red LED GENERAL SPECIFICATIONS
Supply Voltage : 15 to 30 V DC
2-Wire DC (NAMUR)
Indication : Red LED
SW 4052 / 5052
Over Current Protection : Provided
The NAMUR type sensors are Intrinsically safe Proximity Operating Temperature : -25°C to +70°C
Switches designed to work in the hazardous areas.
Cable Length : 10 meter max.
The working voltage & current levels of these switches
are restricted to safe values as per the recommended 2-Wire AC
standards. These sensors are to be used with an SW 4055 / 5055 / 6055
external Power Supply Unit (Amplifier Unit).
The AC Switches are designed for 2 wire
connection and operate on full line voltage. The
Brown loads are to be connected in series with the switch
Connection Diagram For
NAMUR 2 Wire DC Switch in a similar manner to that of a mechanical limit
Blue switch. The external load can be PLC, Contactor,
Relay etc. The operating (OFF state) current of
these switches is less than 2 mA.
GENERAL SPECIFICATIONS
Supply Voltage : 8.5 V DC
Indications : Red LED Brown
Connection Diagram For
Operating Current For `NC’ Type Switch 2 Wire AC Switch
Blue
3
SPECIAL FUNCTION SWITCHES
Switches with special function as given below are HIGH TEMPERATURE MODELS
available against specific requirement. Switches operating up to 150°C ambient temp. are
available for specific applications. These switches are
LINEAR OUTPUT generally used with an external amplifier unit. This
Inductive / Capacitive / Optical / Ultrasonic type amplifier unit can be installed up to a distance of 10
sensors are available with linear output signal (4-20 meters at normal ambient temperature.
mA / 0-10 V DC) proportionate to object distance.
Details are given under individual sections. COLOUR BAND / SPECTRUM SENSORS
Inductive type switches have maximum sensing gap WELD IMMUNE SWITCHES
defined for ferrous object. The sensing gap reduces for Same model of Inductive switches are available to work
other metals. Special models are available to sense in highly electrical noisy Area such as Welding
only non-ferrous object such as Al, Cu, Gold etc. at Machine.
the same distance as ferrous object. These switches
are available in M18 and above sizes in SW 4051 and HIGH PRESSURE SWITCHES
SW 4055 types. Details are given under
separate heading in later sections. High pressure Inductive Type proximity switches are
available for various applications, especially in the field
SWITCHES WITH BUILT-IN TIMER of hydraulics for pressures up to 500 bar.
Switches above M18 size (DC or AC) provided with ALL METAL PROXIMITY SWITCHES
built-in tier function are available on request. In such
switches, the output will change its state after the set Inductive proximity switches with all body of stainless
time delay (ON Delay) or return to normal state after steel including front cap, to meet special requirement,
time delay (OFF Delay). This feature is available with are available in M12, M18 and M30 sizes.
all types of proximity switches except Magnetic.
4
Inductive Proximity Switches
Series - SW 405 / 415
Engineering Industries
l HIGH PRESSURE SWITCHES
SENSING OBJECT MATERIAL Special high pressure type Inductive Proximity Switch
has been developed for direct use in a Hydraulic
The standard Inductive Proximity Switches can sense
cylinder.
any metallic (electrically conductive) object. However,
we have special type of switches to sense either only The switch construction is sturdy and is rated for
ferrous objects or sense only non-ferrous (Cu, Al etc.) pressure upto 500 bar.
objects. The details for the non-ferrous sensing switches These switches are also available in connector version
are described elsewhere. for easy replacement.
5
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
INDUCTIVE Ø4 Ø5 M5 Ø6 M6
SW 4053/4153 DC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.
6
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. N.A. M8 M10
Length (mm) N.A. 35, 50, 65 50, 65
Sensing Distance Sn. (mm) N.A. F - 1.5 NF - 2 F - 1.5 NF - 2
Enclosure N.A. B, S B, S
Load Current (mA) N.A. 100 100
Supply Voltage (V DC) N.A. D6 D6
Switching Frequency (Hz) N.A. 1000 1000
Logic Available N.A. NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. M8 M10
Length (mm) N.A. 80 80
Sensing Distance Sn. (mm) N.A. NF - 2 F - 1.5 NF - 2
Enclosure N.A. B.S. B.S.
Load Current (mA) N.A. 200 100
Supply Voltage (V AC) N.A. A1 to A4 A1 to A4
Switching Frequency (Hz) N.A. 15 15
Logic Available N.A. NO, NC NO, NC
7
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. M12 M14 M16
Length (mm) 40, 50, 65 40, 50, 65 35, 50, 65
Sensing Distance Sn. (mm) F - 2.5 NF - 4 F - 2.5 NF - 4 F-3 NF - 5
Enclosure B, A, S B, A, S B, S
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 1000 1000 1000
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. M12 M14 M16
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 2.5 NF - 4 F - 2.5 NF - 4 F-3 NF - 5
Enclosure B, A, S B, A, S B, S
Load Current (mA) 200 200 200
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
8
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. M18 Ø20 M22
Length (mm) 35, 50, 65 65 65
Sensing Distance Sn. (mm) F-5 NF - 8 F-7 NF - 10 F-5 NF - 8
Enclosure B, A, S, T A B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 500 500
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. M18 Ø20 M22
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F-5 NF - 8 F-7 NF - 10 F-5 NF - 8
Enclosure B, A, S, T A B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
9
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. M24 M30 M32
Length (mm) 50, 65 50, 65 65
Sensing Distance Sn. (mm) F-8 NF - 10 F - 10 NF - 15 F - 10 NF - 15
Enclosure B, S B, A, S, T B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 200 200
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. M24 M30 M32
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F-8 NF - 10 F - 10 NF - 15 F - 10 NF - 15
Enclosure B, S B, A, S, T B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
10
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. Ø34 M36 M42
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 12 NF - 16 F - 13 NF - 16 F - 15 NF - 18
Enclosure A B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 200 200
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. Ø34 M36 M42
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 12 NF - 16 F - 13 NF - 16 F - 15 NF - 18
Enclosure A B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
11
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. M50 M55 M60
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 16 NF - 20 F - 16 NF - 20 F - 20 NF - 25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 100 200
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. M50 M55 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 16 NF - 20 F - 16 NF - 20 F - 20 NF - 25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
12
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. M80 D150 H100*80
Length (mm) 65 185 x 185 x 87.5 100 x 80 x 45
Sensing Distance Sn. (mm) F - 30 NF - 35 F - 100 F-40
Enclosure B, S A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 100 100
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. M80 D150 H100*80
Length (mm) 80 185 x 185 x 87.5 100 x 80 x 45
Sensing Distance Sn. (mm) F - 30 NF - 35 F - 100 F-40
Enclosure B, S A A
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
13
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. N. A. N. A. D17
Length (mm) N. A. N. A. 30 x 17 x 17
Sensing Distance Sn. (mm) N. A. N. A. 5
Enclosure N. A. N. A. A
Load Current (mA) N. A. N. A. 200
Supply Voltage (V DC) N. A. N. A. D4
Switching Frequency (Hz) N. A. N. A. 500
Logic Available N. A. N. A. NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N. A. N. A. N.A.
Length (mm) N. A. N. A. N.A.
Sensing Distance Sn. (mm) N. A. N. A. N.A.
Enclosure N. A. N. A. N.A.
Load Current (mA) N. A. N. A. N.A.
Supply Voltage (V AC) N. A. N. A. N.A.
Switching Frequency (Hz) N. A. N. A. N.A.
Logic Available N. A. N. A. N.A.
14
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. D18 D20 DFS25
Length (mm) N.A. 38 x 20 x 20 65 x 25 x 25
Sensing Distance Sn. (mm) N.A. 5 2-9
Enclosure N.A. A A
Load Current (mA) N.A. 200 200
Supply Voltage (V DC) N.A. D6 D6
Switching Frequency (Hz) N.A. 500 50
Logic Available N.A. NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. D18 D20 DFS25
Length (mm) N.A. N.A. 65 x 25 x 25
Sensing Distance Sn. (mm) N.A. N.A. 2-9
Enclosure N.A. N.A. A
Load Current (mA) N.A. N.A. 200
Supply Voltage (V AC) N.A. N.A. A1 to A5
Switching Frequency (Hz) N.A. N.A. 15
Logic Available N.A. N.A. NO, NC
15
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. D35 DFS40 D40
Length (mm) 35 x 35 x 48 112.5 x 40 x 40 112.5 x 40 40
Sensing Distance Sn. (mm) 15 2-13 15
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 100 100
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. D35 DFS40 D40
Length (mm) 35 x 35 x 48 112.5 x 40 x 40 112.5 X 40 40
Sensing Distance Sn. (mm) 15 2-13 15
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
16
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. DV40 (Veriable Sensing Head) D50 N.A.
Length (mm) 118 x 40 x 40 120 x 50 x 50 N.A.
Sensing Distance Sn. (mm) 15 20 N.A.
Enclosure A A N.A.
Load Current (mA) 400 400 N.A.
Supply Voltage (V DC) D6 D6 N.A.
Switching Frequency (Hz) 100 100 N.A.
Logic Available NO, NC NO, NC N.A.
SW 4055/4155 AC 2 WIRE
Dimension : Dia. DV40 (Veriable Sensing Head) D50 N.A.
Length (mm) 118 x 40 x 40 120 x 50 x 50 N.A.
Sensing Distance Sn. (mm) 15 20 N.A.
Enclosure A A N.A.
Load Current (mA) 400 400 N.A.
Supply Voltage (V AC) A1 to A5 A1 to A5 N.A.
Switching Frequency (Hz) 15 15 N.A.
Logic Available NO, NC NO, NC N.A.
17
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. Gap 5 Gap 10
Length (mm) N.A. 75 x 50 x 72 75 x 50 x 72
Sensing Distance Sn. (mm) N.A. 5 mm 10 mm
Enclosure N.A. A A
Load Current (mA) N.A. 200 200
Supply Voltage (V AC) N.A. A1 to A5 A1 to A5
Switching Frequency (Hz) N.A. 15 15
Logic Available N.A. PO, NO PO, NO
18
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. Gap 15 H402512 H5025
Length (mm) 61 x 30 x 45 40 x 25 x 12 50 x 25 x 10
Sensing Distance Sn. (mm) 15 mm 4 5
Enclosure A A B
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 300 300
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.?
Logic Available N.A. N.A. N.A.
19
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. H5022 IN10-4 H2816
Length (mm) 50 x 45 x 22 120 x 102 x 86 28 x 16 x 10
Sensing Distance Sn. (mm) 5 5 1.5
Enclosure B A+B A
Load Current (mA) 200 200 1000
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 100 200
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. H5022 IN10-4 N.A.
Length (mm) 50 X 45 X 22 120 x 102 x 86 N.A.
Sensing Distance Sn. (mm) 5 5 N.A.
Enclosure B A+B N.A.
Load Current (mA) 200 200 N.A.
Supply Voltage (V AC) A1 to A5 A1 to A5 N.A.
Switching Frequency (Hz) 15 15 N.A.
Logic Available NO, NC NO, NC N.A.
20
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. H4421 H5437 H7216
Length (mm) 44 x 21 x 16 54 x 37 x 14 72 x 16 x 10
Sensing Distance Sn. (mm) 3 2.5 1.5
Enclosure A A A
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 1000 1000 1000
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.
21
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. H4512 H5515 N.A.
Length (mm) 45 x 12 x 12 55 x 35 x 15 N.A.
Sensing Distance Sn. (mm) 2.5 10 N.A.
Enclosure A A N.A.
Load Current (mA) 200 200 N.A.
Supply Voltage (V DC) D6 D6 N.A.
Switching Frequency (Hz) 1000 100 N.A.
Logic Available NO, NC NO, NC N.A.
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. H5515 N.A.
Length (mm) N.A. 55 x 35 x 15 N.A.
Sensing Distance Sn. (mm) N.A. 10 N.A.
Enclosure N.A. A N.A.
Load Current (mA) N.A. 200 N.A.
Supply Voltage (V AC) N.A. A1 to A5 N.A.
Switching Frequency (Hz) N.A. 15 N.A.
Logic Available N.A. NO, NC N.A.
22
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
1
2
3
4
5
6
SW 4053/4153 DC 2 WIRE
Dimension : Dia. H7930 H3855 H3045
Length (mm) 79 x 30 x 24 38 x 55 x 16 30 x 45 x 22
Sensing Distance Sn. (mm) 2 5 5
Enclosure A A A
Load Current (mA) 400 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 500 500
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.
23
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. H2063 H10080 R6
Length (mm) 20 x 11 x 63 100 x 80 x 45 61 x 37 x 30
Sensing Distance Sn. (mm) 5 50 6
Enclosure A A A
Load Current (mA) 200 300 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 200 100
Logic Available PO, PC, NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. H10080 R6
Length (mm) N.A. 100 x 80 x 45 N.A.
Sensing Distance Sn. (mm) N.A. 50 N.A.
Enclosure N.A. A N.A.
Load Current (mA) N.A. 300 N.A.
Supply Voltage (V AC) N.A. A1 to A5 N.A.
Switching Frequency (Hz) N.A. 15 N.A.
Logic Available N.A. NO, NC N.A.
24
INDUCTIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 4053/4153 DC 2 WIRE
Dimension : Dia. R 10 R 22 R 30
Length (mm) 61 x 37 x 30 71 x 41 x 16 73 x 52 x 17
Sensing Distance Sn. (mm) 10 20 30
Enclosure A A A
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 100 100 100
Logic Available NO, NC NO, NC NO, NC
SW 4055/4155 AC 2 WIRE
Dimension : Dia. R 10 N.A. N.A.
Length (mm) 61 x 37 x 30 N.A. N.A.
Sensing Distance Sn. (mm) 10 N.A. N.A.
Enclosure A N.A. N.A.
Load Current (mA) 200 N.A. N.A.
Supply Voltage (V AC) A1 to A5 N.A. N.A.
Switching Frequency (Hz) 15 N.A. N.A.
Logic Available PO, PC, NO, NC N.A. N.A.
25
ANALOGUE PROXIMITY SWITCHES
SW 4051/4151 DC 3 WIRE
Dimension : Dia. M18 M30 M36
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F : 2-5 NF : 2-8 F : 2-10 NF : 3-15 F : 2-10 NF : 3-15
Enclosure A A B,S
Load Current (mA) 20mA 20mA 20mA
Supply Voltage (V DC) D10 D10 D10
Switching Frequency (Hz) 25 25 25
Logic Available LOI, LOV LOI, LOV LOI, LOV
SW 4051/4151 DC 3 WIRE
Dimension : Dia. M50 C20 M80
Length (mm) 65 48 65
Sensing Distance Sn. (mm) F : 4-12 F : 5-16 F : 0-9 F : 4-12
Enclosure B,S A A
Load Current (mA) 20mA 20mA 20mA
Supply Voltage (V DC) D10 D10 D10
Switching Frequency (Hz) 25 25 25
Logic Available LOI, LOV LOI, LOV LOI, LOV
10
8
VOLTAGE (V)
4
2
2 4 6 8
DIST. (mm)
26
Capacitive Proximity Switches
Series - SW 505
INTRODUCTION
The Series SW 505 Capacitive Proximity Switches are Sensing Distance for
Sensing Distance in mm
designed for sensing wide range of materials. These various materials
switches give a superior performance for detection of 25
20
various non-metallic objects where Inductive type 15
switches can not function. 10
The major applications of Capacitive Switches include 5
0
sensing of;
...
s
r
C
S
Liquid level
rd d
d
Ea
ate
as
/A
M
PV
l
ar
o
l(
Gl
Bo
W
W
Cu
/A
lPlastic granules & parts
Cu
Ca
lSand / Bulk Material Level
Fig.1
lFood / Grain / Confectionary
GENERAL SPECIFICATIONS
lPaper & rubber
Operating Temperature : 55°C Max.
lGlass bottles / Tins in packaging
Response Time : 2 to 5 milliseconds
WORKING PRINCIPLE
Hysteresis : 3% to 15 %
The switch works on the principle of resonant oscillator of actuating point
circuit. A pair of brass/copper disc form the electrodes
Protection Grade : IP-67
of a capacitor & the object acts as a dielectric media.
The change in capacitance value, due to presence of Quiescent Current : 1) DC - 8 mA Max.
object, is sensed by a precision integrated circuit. An 2) AC - 2 mA Max.
effective output signal is generated at a preset value of Indication : LED for object status
capacitance.
Output : 1) To drive a Relay
CONSTRUCTION 2) PLC Compatible
These are offered in tubular threaded housing from size
M12 to M80. The enclosures are made of Brass, SPECIAL MODELS
Stainless Steel or Engineering Plastics. Special shapes, Special High Temperature models of Capacitive
Teflon housings are provided against requirements. switches are available with Operating Temperature upto
Standard models are provided with an integrated 150°C max.
2 meter long cable. Connector type versions are These switches are provided with a teflon front cap and
available with built-in male connectors. with suitable teflon cable.
These switches are to be used with a specially designed
SENSING DISTANCE controller/amplifier unit.
The nominal sensing distance of any size of switch is The permitted operating length between sensor and the
specified with Water as standard object and tested at controller is maximum 5 meters.
25°C.Depending upon the material of the object to be NAMUR type switches are available with
detected, the distance will vary. The sensitivity of the CMRI-Certificate and approved Power Supply Unit with
sensor is adjustable with a trimpot provided usually on built-in Zener barrier circuit.
the rear side of the sensor. Typical Sensing distance
chart for a M30 size sensor, for different objects is PROTECTIONS
shown in Fig-1. All the Capacitive switches are provided with Reverse
polarity, Overload, short circuit and false pulse
EFFECT OF AMBIENT CONDITIONS ON protections.
SENSITIVITY Rugged construction along with IP-67 grade of
The sensing distance is affected by change in ambient protection renders these switches to be very useful for
temperature, humidity, size and material of the object. liquid level monitoring applications.
27
CAPACITIVE PROXIMITY SWITCHES
RECTANGULAR
REED TYPE/ SW 715
TYPE SW 705
SW 5053/5153 DC 2 WIRE
Dimension : Dia. M12 M18 Ø20
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-3 F-2-5 NF-2-5 F-2-10 NF-2-7 NF-2-10
Enclosure B, A, S B, A, S, T A
Load Current (mA) 200 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 25 50 50
Logic Available NO, NC NO, NC NO, NC
SW 5055/5155 AC 2 WIRE
Dimension : Dia. M12 M18 Ø20
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-3 F-2-5 NF-2-5 F-2-10 NF-2-7 NF-2-10
Enclosure B, A, S B, A, S, T A
Load Current (mA) 200 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
28
CAPACITIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 5053/5153 DC 2 WIRE
Dimension : Dia. M24 M30 Ø34
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-8 F-2-10 NF-2-10 F-3-15 NF-3-12 NF-3-16
Enclosure B, S B, A, S, T A
Load Current (mA) 400 400 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC
SW 5055/5155 AC 2 WIRE
Dimension : Dia. M24 M30 Ø34
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-8 F-2-10 NF-2-10 F-3-15 NF-3-12 NF-3-16
Enclosure B, S B, A, S, T A
Load Current (mA) 400 400 200
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
29
CAPACITIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 5053/5153 DC 2 WIRE
Dimension : Dia. M36 M50 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 3-13 F - 3-16 F - 3-16 NF - 3-20 F - 3-20 NF - 3-25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC
SW 5055/5155 AC 2 WIRE
Dimension : Dia. M36 M50 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 3-13 F - 3-16 F - 3-16 NF - 3-20 F - 3-20 NF - 3-25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
30
CAPACITIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 5053/5153 DC 2 WIRE
Dimension : Dia. D40 DV40 (Variable Sensing Head) D50
Length (mm) 112.5 x 40 x 40 118 x 40 x 40 120 x 50 x 50
Sensing Distance Sn. (mm) 3 - 15 3 - 15 3 - 20
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 100 100 100
Logic Available NO, NC NO, NC NO, NC
SW 5055/5155 AC 2 WIRE
Dimension : Dia. D40 DV40 (Variable Sensing Head) D50
Length (mm) 112.5 x 40 x 40 118 x 40 x 40 120 x 50 x 50
Sensing Distance Sn. (mm) 3 - 15 3 - 15 3 - 20
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC
31
CAPACITIVE PROXIMITY SWITCHES
RECTANGULAR TYPE
SW 5053/5153 DC 2 WIRE
Dimension : Dia. H5025 H5515 H120*80
Length (mm) 50 x 25 x 10 55 x 35 x 15 120 x 80 x 30
Sensing Distance Sn. (mm) 5 10 50
Enclosure B A A
Load Current (mA) 200 200 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 300 100 500
Logic Available NO, NC NO, NC NO, NC
SW 5055/5155 AC 2 WIRE
Dimension : Dia. N.A. H5515 H120*80
Length (mm) N.A. 55 x 35 x 15 120 x 80 x 30
Sensing Distance Sn. (mm) N.A. 10 50
Enclosure N.A. A A
Load Current (mA) N.A. 200 400
Supply Voltage (V AC) N.A. A1 to A5 A1 to A5
Switching Frequency (Hz) N.A. 15 15
Logic Available N.A. NO, NC NO, NC
32
OPTICAL PROXIMITY SWITCHES
Series - SW 605
Object
Object
33
OPTICAL PROXIMITY SWITCHES
RECTANGULAR
SW 6051 / 6151TYPE
AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 50 F - 200 F - 1 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO
SW 6051 / SW 6055 TB
AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 2 Mtr. F - 5 Mtr. F - 10 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO
SW 6051 / SW 6055 RR
AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 500 F - 1 Mtr. F - 5 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO
34
OPTICAL PROXIMITY SWITCHES
RECTANGULAR
SW TYPEDS
6151 / SW 6155
AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 50 F - 200 F - 1 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO
SW 6151 / SW 6155 TB
AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 2 Mtr. F - 5 Mtr. F - 10 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO
SW 6151 / SW 6155 RR
AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 500 F - 1 Mtr. F - 5 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO
35
OPTICAL PROXIMITY SWITCHES
RECTANGULAR TYPE
DC 3 Wire
Enclosure Type H28*16 H31*17 H40*25
Dimension : Length (mm) 28 x 16 x 10 31 x 17 x 12 40 x 25 x 12
Sensing Distance (DS) 20 20 120
(RR) N.A. N.A. 300
(TB) N.A. N.A. 300
Enclosure A A A
Load Current (mA) 100 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 50 50 15
Logic Available PO, NO PO, NO PO, NO
DC 3 Wire
Enclosure Type H60*40 H50*55 H35*35
Dimension : Length (mm) 60 x 40 x 20 50 x 55 x 22 44 x 35 x 18
Sensing Distance (DS) 300 500 100
(RR) N.A. 2 Mtr. N.A.
(TB) N.A. 10 Mtr. N.A.
Enclosure A A A
Load Current (mA) 200 200 100
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 15 50 50
Logic Available PO, NO PO, NO PO, NO
DC 3 Wire
Enclosure Type H50*25 R22 G100
Dimension : Length (mm) 50 x 25 x 15 40 x 40 x 38 128 x 81 x 30
Sensing Distance (DS) 50 N.A. N.A.
(RR) 200 For Water Drop 120
(TB) 1 Mtr. N.A. N.A.
Enclosure A A A
Load Current (mA) 100 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 10 10 15
Logic Available PO, NO PO, NO PO, NO
36
MAGNETIC PROXIMITY SWITCHES /
SPEED SENSORS
Series SW 705 / SW 715 / MSP 706/MSP /716 MSP 707/MSP 717
These switches are used only for position sensing The 2-wire switches should be necessarily used
application. These incorporate a hermetically with a special controller / amplifier unit.
sealed sensitive reed element. The object should
necessarily be a magnet. These are provided with APPLICATIONS
2-core built-in cable. The output is a potential free
Turbine high-speed sensor.
l
contact and can switch external load directly.
Bucket Elevator high temperature sensor.
l
The switching voltage and contact rating depends
upon switch size. Special models of latching type
switches are available for direction sensing AUTOMOBILE SENSORS
applications. Special / custom built models are available for
Automobile applications as below;
GENERAL SPECIFICATIONS
Transfer case speed sensor.
l
Sensing Range: 10 to 50 mm depending upon
Strength of object magnet. Wheel Rotation sensor for Fare-meter.
l
APPLICATIONS
Position sensing in hydraulic cylinders,
Roto-meters,
Direction sensing applications
Level sensing of liquids
37
MAGNETIC PROXIMITY SWITCHES
RECTANGULAR
DC SW7051/ ACTYPE
SW7055
MAGNETIC
MAGNETIC
MAGNETIC
38
MAGNETIC PROXIMITY SWITCHES
RECTANGULAR
DC SW7061 TYPE
DC SW7071
MAGNETIC
MAGNETIC
39
ULTRASONIC PROXIMITY SWITCHES
SERIES SW 305 / SW 315
The sensing range covers from 0.2 m to 20 meters. The lDetection of moving objects.
output signal is either in the form of a switching signal or lOpening / Closing of doors by detecting motion.
a linear output current or voltage signal. These sensors
have the ability to perform in dry and dusty GENERAL SPECIFICATIONS
environments. The performance of these sensors is not
affected by the presence of impeding materials like Ash, Output Signal : Switching/ Linear output
Soot, and Sawdust etc. Protection Grade : IP-67
These sensors are immune to electrical noise level Termination : Integrated 2-meter long cable.
generally present in the typical industrial environment. Sensing Range : 0.4 to 20 meters depending on
model and application.
WORKING PRINCIPLE
FEATURES
These switches incorporate a precise and delicate piezo
Ceramic Ultrasonic transducer pair. The sensors are The Ultrasonic Sensors are provided with programming
available in open as well as sealed type transducers. facility. General features available in programmable
sensors are as below;
The transmitter sends a modulated Ultrasonic Signal,
which is reflected by the object. lOutputs: Push-button "teachable”
SW 3051 DC 3 Wire
Dimension : Dia. M30 M60
Length (mm) 100 100
Sensing Distance Sn. (mm) 0.2 to 2 Mtr. 0.2 to 10 Mtr.
Enclosure A A
Load Current (mA) 20 20
Supply Voltage (V DC) D1 to D6 D6
Switching Frequency (Hz) 10 20
Logic Available PO, NO, LO LO
40
41
SELECTION CHART
While selecting a switch please follow this nomenclature
SW 4 0 5 1 NO D1 B X 18 XX XX
The Sensing Distance, Load Current, Switch Length, Cable Length, Operating Temperature will be as per
factory standard unless otherwise specifically mentioned.
Example : Inductive Proximity Switch of 3-Wire DC PNP tubular type with 24 mm diameter will have
following type no. SW 4051 PO D1 B24
42