0% found this document useful (0 votes)
114 views42 pages

Capacitive Proximity Switch

The document discusses proximity switches, which provide contactless position sensing as an alternative to limit switches. It describes the different types of proximity switches including inductive, capacitive, optical, ultrasonic and magnetic, and covers their principles of operation, features, applications, and construction details.

Uploaded by

svaish13
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
114 views42 pages

Capacitive Proximity Switch

The document discusses proximity switches, which provide contactless position sensing as an alternative to limit switches. It describes the different types of proximity switches including inductive, capacitive, optical, ultrasonic and magnetic, and covers their principles of operation, features, applications, and construction details.

Uploaded by

svaish13
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 42

PROXIMITY SWITCHES

INTRODUCTION These switches are totally epoxy potted to meet IP-68


Jayashree Electron has been manufacturing quality grade of protection. The switches are also available in
Proximity Switches since year 1980. As one of the various other shapes such as Rectangular, Slot, Block,
largest manufacturers, we offer over 500 models of Button, and insert type modules. Our Proximity
Inductive, Capacitive, Optical, Ultrasonic & Magnetic Switches meet CE requirements.
Proximity Switches. With continuous induction of latest
ADVANTAGES
technologies, our proximity switches are keeping pace
with time. With over 2000 satisfied customer spread all Non-Contact
l sensing.
over India & abroad, we are committed to maintain high No operating
l force necessary.
standards in Quality and Prompt deliveries. No mechanical
l moving part.

APPLICATION No backlash.
l

Proximity switches provide better alternative to the Bounce-free


l operation.
conventional electro-mechanical limit switches for Operation
l possible from different directions
position sensing. It is a best solution to all linear / rotary Compact
l sizes and versatile sensing arrangement.
counting applications. They find wide application in Works
l in rugged Industrial Environment consisting of
Machine tools, Foundries, Rolling mills, Automobile, dust, water, lubricants and cutting oils.
Textile, Pharmaceutical, Material handling and all
High
l switching frequency.
automation systems in general.
High
l repeat accuracy.
CONSTRUCTION Visual
l LED indications for status of switch
The Proximity switches are generally. available in
Suitable
l for Intrinsically safe operation in Hazardous
tubular enclosures with diameter from 4 mm to 140
areas.
mm. These enclosures are made of Stainless Steel,
Withstands
l vibrations and mechanical shocks
Nickel Plated Brass or Engineering Plastics as required
by the application. Long
l and maintenance free life.

TYPES OF PROXIMITY SWITCHES


A critical element of sensing, automation & control, Proximity Switches are available in Inductive, Capacitive,
Optical, Ultrasonic and Magnetic based on the object Sensing principle.

TYPE SENSING FEATURES APPLICATIONS


PRINCIPLE

INDUCTIVE Damping of Senses only metallic objects Machine Tools / Robotics


oscillations by Useful for medium counting Bulk Material handling
conductive speed For Counting /
materials Short Sensing gaps Position Sensing

CAPACITIVE Senses dielectric Senses non-metallic, Pharmaceuticals / Food Processing


properties of metallic as well as liquid Plastics
object material Low counting speed For Level Sensing / Automation

OPTICAL Infra-red reflection Senses any object Robotics / Automobile / Foundry /


Longer Sensing Distance Plastic / Pharma /
Medium counting speed Food Processing / Engg.
High position sensing For Position / Level sensing / Counting
accuracy / Automation Safety / Instruments

MAGNETIC Magnetic Senses only ferrous Automobile / Process Engg.


reluctance/Reed objects / magnets For High Speed counting
Switch High counting speed Cylinder / Valve sensing applications

ULTRASONIC High Frequency Senses any material. Automobile / Process Engg.


Ultra-Sound Wave Long sensing gaps For Distance measurement
Propagation Level sensing.

1
EXPLANATION OF TECHNICAL TERMS SUPPLY VOLTAGE
For DC switches, a filtered and ripple-free regulated
SENSING DISTANCE power supply should be used and for AC switches the
This is the distance between the target and the sensing supply should be EMI free as far as possible
face at witch the switch operates. This is usually specified
SWITCHING HYSTERISIS
considering a standard object for each type of switch.
This is a differential between “Switch ON” and “Switch
OFF” point of the switch. This is adjusted within limits
5% to 15% of the specified sensing distance

OUTPUT LOGIC
The output switching element (either a Transistor or
Thyristor) can be normally in Closed (ON) or Open
(OFF) condition.
The output logic has to be very carefully selected
considering the application requirement.
For specific applications, the inductive switches above
STANDARD OBJECTS M24 size are available with built-in electromagnetic
For different types of switches following objects are relay to give a potential free output contact for
considered as standard while specifying the sensing gap switching external loads. The output logic in this case
Inductive - MS disc of min. 1 mm thick and size same can be NO, NC and CO (Change-Over) type. Switches
as sensing face. with a specific output logic such as latched type.
Oscillator type are available on request.
Capacitive - Water/MS of min.10mmthick and size
same as sensing face. LOAD CURRENT
Optical - White paper of 100x100 mm size. This is the maximum current, which the switch can
Magnetic - Ferrous Material. either sink or source to the external load.

REPEAT ACCURACY APPLICABLE STANDARDS


This is the accuracy within which the switch operates Following standards are being followed for design and
repeatatively at same point given stable operating manufacture : l IEC-60947-5-2 l UL-508
conditions. For Inductive switches, the accuracy is l CSA 22.2 NO. 14-95
better than +/- 0.2 % l S 13947-5-2

RESPONSE TIME TYPES OF OUTPUT CONNECTIONS


This is the time in which the switch changes its
3-Wire & 4-Wire DC
state after target enters the sensing zone. For DC
SW3051 / 4051 / 5051 / 6051 / 7071
switches the response time can be as low as 0.3
milliseconds but for AC switches this is around 20 These switches operate on DC voltages from 5 volts to
milliseconds. 240 volts. Standard models operate on 10-30 V DC and
can be used with logic circuits, Counters or to drive
FLUSH MOUNTING Relay Coil directly. The output of these switches can be
Switches referred to as flush type (embeded ) can either PNP or NPN or both.
a mounted inside metal body and have only frontal With PNP output, the switching is in the sourcing mode
electromagnetic field. The sensing distance in this and the load must be connected between the Output
case is limited to 0.7 times the sensing distance and the Negative of the supply. Conversely with NPN
specified for a non-flush type switch. output the switching is in sinking mode and the load
must be connected between the output and the
3xd
positive of the supply All 3 wire and 4 wire DC switches
d >d d d
are internally protected against inductive voltage
Metal

Metal

>2 x Sn spikes, spurious line noise. Reverse polarity and short


circuit conditions.

Connection Diagram For


NON-FLUSH MOUNTING 3 Wire DC PNP Switch
These type of switches should necessarily be mounted
with sensing zone in metal free area.

2
GENERAL SPECIFICATIONS (Standard Switch)
Supply Voltage : 10 to 30 V DC Brown
Reverse Polarity Protection : Provided for all models Connection Diagram For
2 Wire DC Switch
Blue
Short Circuit Protection : Provided for
sizes M8 & above
Operating Temperature : -25°C to +70°C
Indication : Red LED GENERAL SPECIFICATIONS
Supply Voltage : 15 to 30 V DC
2-Wire DC (NAMUR)
Indication : Red LED
SW 4052 / 5052
Over Current Protection : Provided
The NAMUR type sensors are Intrinsically safe Proximity Operating Temperature : -25°C to +70°C
Switches designed to work in the hazardous areas.
Cable Length : 10 meter max.
The working voltage & current levels of these switches
are restricted to safe values as per the recommended 2-Wire AC
standards. These sensors are to be used with an SW 4055 / 5055 / 6055
external Power Supply Unit (Amplifier Unit).
The AC Switches are designed for 2 wire
connection and operate on full line voltage. The
Brown loads are to be connected in series with the switch
Connection Diagram For
NAMUR 2 Wire DC Switch in a similar manner to that of a mechanical limit
Blue switch. The external load can be PLC, Contactor,
Relay etc. The operating (OFF state) current of
these switches is less than 2 mA.
GENERAL SPECIFICATIONS
Supply Voltage : 8.5 V DC
Indications : Red LED Brown
Connection Diagram For
Operating Current For `NC’ Type Switch 2 Wire AC Switch
Blue

TARGET Switch Current I mA


Absent 3 < I <5
Present I < 1 mA GENERAL SPECIFICATIONS
Other specifications are as per specifications of Supply Voltage : 24 / 110 / 240 / 20-240 V AC
3 Wire DC Proximity Switches. Quiescent Current : Less than 2 mA
Intrinsically
l Safe as per IS-5780-2004 Load Current : 200-400 mA (max.)
and IS 13346 - 2004 10 mA (min.)
Approved
l by - ERTL / CCOE. Inrush Current : 10 x specified load current
Amplifier
l Unit (Power Supply Unit) for 10 ms.
Type - PSU 4052. Indication : Red LED
Supply Voltage - 110 / 240 V AC Protection : Against surges by MOV
Output contacts - 1NO + 1NC Start-up Delay : 50 ms max.
Contact Rating - 5 A @ 240 V AC Note : The switches require about 8 V for its own
Approved
l by - ERTL / CCOE. working and will always give output voltage less by 8
V than supply voltage.
2-Wire DC
SW 4053 / 5053 / 6053 For PLC
l loads, special low quiescent current models
available.
These Switches are designed to operate external
loads connected in series with the switch. These 2-Wire AC/DC
switches differ from the NAMUR type due to higher SW 4054 / 5054
operating voltage and currents. During operation,
there is a voltage drop of about 6 V across the These switches operates on AC as well as DC from 20
switch & the load connected in series gets the volts to 240V. The load is to be connect in similar
reduced supply voltage accordingly. manner to 2-wire AC switches.

3
SPECIAL FUNCTION SWITCHES
Switches with special function as given below are HIGH TEMPERATURE MODELS
available against specific requirement. Switches operating up to 150°C ambient temp. are
available for specific applications. These switches are
LINEAR OUTPUT generally used with an external amplifier unit. This
Inductive / Capacitive / Optical / Ultrasonic type amplifier unit can be installed up to a distance of 10
sensors are available with linear output signal (4-20 meters at normal ambient temperature.
mA / 0-10 V DC) proportionate to object distance.
Details are given under individual sections. COLOUR BAND / SPECTRUM SENSORS

These sensors are available only is optical category.


FAIL SAFE SWITCHES The Colour Mark Sensor can detect a preset colour
Inductive type switches, used for critical applications band and the output will chnage-over. In spectrum
are available in a special fail safe version. These are sensors, the output voltage or current changes with
three wire DC switches and work with as specially changing colour bands. Details are given under
designed micro-processor control unit.The controller separate heading.
continuously monitors healthiness of sensors and
gives a signal if the sensor is not working. These TEACH TYPE SWITCHES
models are available for normal as well as hazardous Special Inductive / Optical switches are available in
environment. These switches are available in M18 and `Teach’ type version to sense a object within specified
above sizes. distance band. These are available in M18 and above
sizes.
NON-FERROUS SWITCHES

Inductive type switches have maximum sensing gap WELD IMMUNE SWITCHES
defined for ferrous object. The sensing gap reduces for Same model of Inductive switches are available to work
other metals. Special models are available to sense in highly electrical noisy Area such as Welding
only non-ferrous object such as Al, Cu, Gold etc. at Machine.
the same distance as ferrous object. These switches
are available in M18 and above sizes in SW 4051 and HIGH PRESSURE SWITCHES
SW 4055 types. Details are given under
separate heading in later sections. High pressure Inductive Type proximity switches are
available for various applications, especially in the field
SWITCHES WITH BUILT-IN TIMER of hydraulics for pressures up to 500 bar.

Switches above M18 size (DC or AC) provided with ALL METAL PROXIMITY SWITCHES
built-in tier function are available on request. In such
switches, the output will change its state after the set Inductive proximity switches with all body of stainless
time delay (ON Delay) or return to normal state after steel including front cap, to meet special requirement,
time delay (OFF Delay). This feature is available with are available in M12, M18 and M30 sizes.
all types of proximity switches except Magnetic.

LARGER SENSING AREAS

Switches with built-in multiple sensing heads to cover


larger sensing areas for sensing special objects such
as textile and bearing rings, Hollow objects, Pipes
etc. These switches are supplied in custom made
enclosures to suit specific requirement.

4
Inductive Proximity Switches
Series - SW 405 / 415

PRINCIPLE OF OPERATION SENSING DISTANCE (Sn)


Series SW 405 Inductive Proximity Switches, available in This is the distance between the target and the sensing
varied shapes & sizes, are a reliable option for face at which the switch operates. This is usually
applications in Machine tools, Foundries, Rolling mills, specified considering M.S. as target material.
Automobiles, Textiles, Pharmaceuticals and Material
CORRECTION FACTOR
Handling systems.
Targets other than MS actuate the Inductive Switches at
This type of switches work on ‘Damped Oscillator’
relatively less distance with correction factor as given
principle. During operation a frontally radiated
below. However this criteria is not applicable to special
electromagnetic oscillating field is projected from the
“Non-ferrous sensing models”.
sensing face. Any electrically conductive material
entering this field causes damping of the oscillations. CORRECTION FACTOR TABLE
This change is detected by the in-built sensitive &
Object Material Correction Factor
reliable electronic circuit and is converted into an
effective output signal. MS 1
SS 0.8

Coil Brass 0.5


Object
Oscillator Amplifier Switching Al 0.45
Circuit
Cu 0.4

NON-FERROUS INDUCTIVE SWITCHES


Radiated All standard inductive switches sense presence of any
Field
metal but will offer stated sensing distance only for
ferrous materials like MS.

APPLICATIONS The type SW 4051-NF is specially developed to sense


only non-ferrous metals such as Copper, Aluminium,
For Counting / Position Sensing of various objects in
Gold, Tin, Zinc etc. The biggest advantage of this type
Bulk Material handing
l
of switch is that the non-ferrous objects are sensed from
Automobile
l larger distances as compared to standard models.
Steel Plants
l These switches are available in M18 and above sizes.
Fertilizer
l The other operating features are same as those of
Cement
l standard 3 wire DC Switches.

Engineering Industries
l HIGH PRESSURE SWITCHES

SENSING OBJECT MATERIAL Special high pressure type Inductive Proximity Switch
has been developed for direct use in a Hydraulic
The standard Inductive Proximity Switches can sense
cylinder.
any metallic (electrically conductive) object. However,
we have special type of switches to sense either only The switch construction is sturdy and is rated for
ferrous objects or sense only non-ferrous (Cu, Al etc.) pressure upto 500 bar.
objects. The details for the non-ferrous sensing switches These switches are also available in connector version
are described elsewhere. for easy replacement.

SENSING ZONE Sizes & Sensing Distance


this switch has a dome shaped electro-magnetic field These switches are available from 4 mm dia. to 140 mm
present in front of the sensing area. The switch will dia with sensing distance from 0.5mm to 100 mm.
sense the object entering into this domain.

5
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE Ø4 Ø5 M5 Ø6 M6

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. Ø4 Ø5, M5 Ø6, M6
Length (mm) 35, 50, 65 35, 50, 65 35, 50, 65
Sensing Distance Sn. (mm) F - 0.5 F - 0.8 F-1
Enclosure S S S
Load Current (mA) 100 mA 100 mA 100 mA
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 3000 2000 2000
Logic Available PO, PC, NO, NC PO, PC, NO, NC PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4053/4153 DC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

6
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE Ø6.5 M8 M10

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. Ø6.5 M8 M10
Length (mm) 35, 50, 65 35, 50, 65 50, 65
Sensing Distance Sn. (mm) F-1 F - 1.5 NF - 2 F - 1.5 NF - 2
Enclosure S B, S B, S
Load Current (mA) 100 200 100
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 2000 1000 1000
Logic Available PO, PC, NO, NC PO, PC, NO, NC PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. N.A. M8 M10
Length (mm) N.A. 35, 50, 65 50, 65
Sensing Distance Sn. (mm) N.A. F - 1.5 NF - 2 F - 1.5 NF - 2
Enclosure N.A. B.S. B.S.
Load Current (mA) N.A. 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) N.A. D4 D4
Switching Frequency (Hz) N.A. 1000 1000
Logic Available N.A. NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. N.A. M8 M10
Length (mm) N.A. 35, 50, 65 50, 65
Sensing Distance Sn. (mm) N.A. F - 1.5 NF - 2 F - 1.5 NF - 2
Enclosure N.A. B, S B, S
Load Current (mA) N.A. 100 100
Supply Voltage (V DC) N.A. D6 D6
Switching Frequency (Hz) N.A. 1000 1000
Logic Available N.A. NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. M8 M10
Length (mm) N.A. 80 80
Sensing Distance Sn. (mm) N.A. NF - 2 F - 1.5 NF - 2
Enclosure N.A. B.S. B.S.
Load Current (mA) N.A. 200 100
Supply Voltage (V AC) N.A. A1 to A4 A1 to A4
Switching Frequency (Hz) N.A. 15 15
Logic Available N.A. NO, NC NO, NC

7
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE M12 M14 M16

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. M12 M14 M16
Length (mm) 40, 50, 65 40, 50, 65 35, 50, 65
Sensing Distance Sn. (mm) F - 2.5 NF - 4 F - 2.5 NF - 4 F-3 NF - 5
Enclosure B, A, S B, A, S B, S
Load Current (mA) 200 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 1000 1000 1000
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. M12 M14 M16
Length (mm) 40, 50, 65 40, 50, 65 35, 50, 65
Sensing Distance Sn. (mm) F - 2.5 NF - 4 F - 2.5 NF - 4 F-3 NF - 5
Enclosure B, A, S B, A, S B, S
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 1000 1000 1000
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. M12 M14 M16
Length (mm) 40, 50, 65 40, 50, 65 35, 50, 65
Sensing Distance Sn. (mm) F - 2.5 NF - 4 F - 2.5 NF - 4 F-3 NF - 5
Enclosure B, A, S B, A, S B, S
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 1000 1000 1000
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. M12 M14 M16
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 2.5 NF - 4 F - 2.5 NF - 4 F-3 NF - 5
Enclosure B, A, S B, A, S B, S
Load Current (mA) 200 200 200
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. M12 M14 M16
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 2.5 NF - 4 F - 2.5 NF - 4 F-3 NF - 5
Enclosure B, A, S B, A, S B, S
Load Current (mA) 200 200 200
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

8
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE M18 M20 M22

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. M18 Ø20 M22
Length (mm) 35, 50, 65 50, 65 65
Sensing Distance Sn. (mm) F-5 NF - 8 F-7 NF - 10 F-5 NF - 8
Enclosure B, A, S, T A B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 500 500 500
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. M18 Ø20 M22
Length (mm) 35, 50, 65 65 65
Sensing Distance Sn. (mm) F-5 NF - 8 F-7 NF - 10 F-5 NF - 8
Enclosure B, A, S, T A B, S
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 500 500 500
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. M18 Ø20 M22
Length (mm) 35, 50, 65 65 65
Sensing Distance Sn. (mm) F-5 NF - 8 F-7 NF - 10 F-5 NF - 8
Enclosure B, A, S, T A B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 500 500
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. M18 Ø20 M22
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F-5 NF - 8 F-7 NF - 10 F-5 NF - 8
Enclosure B, A, S, T A B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. M18 Ø20 M22
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F-5 NF - 8 F-7 NF - 10 F-5 NF - 8
Enclosure B, A, S, T A B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

9
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE M24 M30 M32

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. M24 M30 M32
Length (mm) 50, 65 50, 65 65
Sensing Distance Sn. (mm) F-8 NF - 10 F - 10 NF - 15 F - 10 NF - 15
Enclosure B, S B, A, S, T B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 500 200 200
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. M24 M30 M32
Length (mm) 50, 65 50, 65 65
Sensing Distance Sn. (mm) F-8 NF - 10 F - 10 NF - 15 F - 10 NF - 15
Enclosure B, S B, A, S, T B, S
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 500 200 200
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. M24 M30 M32
Length (mm) 50, 65 50, 65 65
Sensing Distance Sn. (mm) F-8 NF - 10 F - 10 NF - 15 F - 10 NF - 15
Enclosure B, S B, A, S, T B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 200 200
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. M24 M30 M32
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F-8 NF - 10 F - 10 NF - 15 F - 10 NF - 15
Enclosure B, S B, A, S, T B.S.
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. M24 M30 M32
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F-8 NF - 10 F - 10 NF - 15 F - 10 NF - 15
Enclosure B, S B, A, S, T B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

10
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE ø34 M36 M42

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. Ø34 M36 M42
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 12 NF - 16 F - 13 NF - 16 F - 15 NF - 18
Enclosure A B, S, B, S
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 200 200 200
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. Ø34 M36 M42
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 12 NF - 16 F - 13 NF - 16 F - 15 NF - 18
Enclosure A B, S, B, S
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 200 200 200
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. Ø34 M36 M42
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 12 NF - 16 F - 13 NF - 16 F - 15 NF - 18
Enclosure A B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 200 200
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. Ø34 M36 M42
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 12 NF - 16 F - 13 NF - 16 F - 15 NF - 18
Enclosure A B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. Ø34 M36 M42
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 12 NF - 16 F - 13 NF - 16 F - 15 NF - 18
Enclosure A B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

11
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE M50 M55 M60

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. M50 M55 M60
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 16 NF - 20 F - 16 Nf - 20 F - 20 NF - 25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 200 100 200
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. M50 M55 M60
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 16 NF - 20 F - 16 NF - 20 F - 20 NF - 25
Enclosure B, S B, S B, S
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 200 100 200
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. M50 M55 M60
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F - 16 NF - 20 F - 16 NF - 20 F - 20 NF - 25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 100 200
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. M50 M55 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 16 NF - 20 F - 16 NF - 20 F - 20 NF - 25
Enclosure B, S B, S B. S,
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. M50 M55 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 16 NF - 20 F - 16 NF - 20 F - 20 NF - 25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

12
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE M80 D150 H100*80*45

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. M80 D150 H100*80
Length (mm) 65 185x185x87.5 100x80x45
Sensing Distance Sn. (mm) F - 30 NF - 35 F - 100 NF - 40
Enclosure B, S A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 200 100 100
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. M80 D150 H100*80
Length (mm) 65 185 x 185 x 87.5 100 x 80 x 45
Sensing Distance Sn. (mm) F - 30 NF - 35 F - 100 F-40
Enclosure B, S A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 200 100 100
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. M80 D150 H100*80
Length (mm) 65 185 x 185 x 87.5 100 x 80 x 45
Sensing Distance Sn. (mm) F - 30 NF - 35 F - 100 F-40
Enclosure B, S A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 100 100
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. M80 D150 H100*80
Length (mm) 65 185 x 185 x 87.5 100 x 80 x 45
Sensing Distance Sn. (mm) F - 30 NF - 35 F - 100 F-40
Enclosure B, S A A
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. M80 D150 H100*80
Length (mm) 80 185 x 185 x 87.5 100 x 80 x 45
Sensing Distance Sn. (mm) F - 30 NF - 35 F - 100 F-40
Enclosure B, S A A
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

13
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE DB4 DB8 D17

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. N.A. DB8 D17
Length (mm) 30 x 4 x 4 40 x 8 x 8 30 x 17 x 17
Sensing Distance Sn. (mm) 0.5 1 5
Enclosure B B, S A
Load Current (mA) 100 100 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 1000 1000 500
Logic Available PO, NO PO, NO PO, NO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. N. A. N. A. D17
Length (mm) N. A. N. A. 30 x 17 x 17
Sensing Distance Sn. (mm) N. A. N. A. 5
Enclosure N. A. N. A. A
Load Current (mA) N. A. N. A. 3 to 5 mA
Supply Voltage (V DC) N. A. N. A. D4
Switching Frequency (Hz) N. A. N. A. 500
Logic Available N. A. N. A. NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. N. A. N. A. D17
Length (mm) N. A. N. A. 30 x 17 x 17
Sensing Distance Sn. (mm) N. A. N. A. 5
Enclosure N. A. N. A. A
Load Current (mA) N. A. N. A. 200
Supply Voltage (V DC) N. A. N. A. D4
Switching Frequency (Hz) N. A. N. A. 500
Logic Available N. A. N. A. NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N. A. N. A. N.A.
Length (mm) N. A. N. A. N.A.
Sensing Distance Sn. (mm) N. A. N. A. N.A.
Enclosure N. A. N. A. N.A.
Load Current (mA) N. A. N. A. N.A.
Supply Voltage (V AC/DC) N. A. N. A. N.A.
Switching Frequency (Hz) N. A. N. A. N.A.
Logic Available N. A. N. A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N. A. N. A. N.A.
Length (mm) N. A. N. A. N.A.
Sensing Distance Sn. (mm) N. A. N. A. N.A.
Enclosure N. A. N. A. N.A.
Load Current (mA) N. A. N. A. N.A.
Supply Voltage (V AC) N. A. N. A. N.A.
Switching Frequency (Hz) N. A. N. A. N.A.
Logic Available N. A. N. A. N.A.

14
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE D18 D20 DFS25

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. D18 D20 DFS25
Length (mm) 36 x 18 x 18 38 x 20 x 20 65 x 25 x 25
Sensing Distance Sn. (mm) 8 5 2-9
Enclosure A A A
Load Current (mA) 200 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 500 500 50
Logic Available PO, NO PO, NO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. D18 D20 DFS25
Length (mm) 36 x 18 x 18 38 x 20 x 20 65 x 25 x 25
Sensing Distance Sn. (mm) 8 5 2-9
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 500 500 50
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. D18 D20 DFS25
Length (mm) N.A. 38 x 20 x 20 65 x 25 x 25
Sensing Distance Sn. (mm) N.A. 5 2-9
Enclosure N.A. A A
Load Current (mA) N.A. 200 200
Supply Voltage (V DC) N.A. D6 D6
Switching Frequency (Hz) N.A. 500 50
Logic Available N.A. NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. D18 D20 DFS25
Length (mm) N.A. N.A. 65 x 25 x 25
Sensing Distance Sn. (mm) N.A. N.A. 2-9
Enclosure N.A. N.A. A
Load Current (mA) N.A. N.A. 200
Supply Voltage (V AC/DC) N.A. N.A. A6
Switching Frequency (Hz) N.A. N.A. 15
Logic Available N.A. N.A. NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. D18 D20 DFS25
Length (mm) N.A. N.A. 65 x 25 x 25
Sensing Distance Sn. (mm) N.A. N.A. 2-9
Enclosure N.A. N.A. A
Load Current (mA) N.A. N.A. 200
Supply Voltage (V AC) N.A. N.A. A1 to A5
Switching Frequency (Hz) N.A. N.A. 15
Logic Available N.A. N.A. NO, NC

15
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE D35 DFS40 D40

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. D35 DFS40 D40
Length (mm) 35 x 35 x 48 112.5 x 40 x 40 112.5 x 40 x 40
Sensing Distance Sn. (mm) 15 2-13 15
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D1 to D8 D1 to D8 D1 to D8
Switching Frequency (Hz) 200 100 100
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. D35 DFS40 D40
Length (mm) 35 x 35 x 48 112.5 x 40 x 40 112.5 x 40 40
Sensing Distance Sn. (mm) 15 2-13 15
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 200 100 100
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. D35 DFS40 D40
Length (mm) 35 x 35 x 48 112.5 x 40 x 40 112.5 x 40 40
Sensing Distance Sn. (mm) 15 2-13 15
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 100 100
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. D35 DFS40 D40
Length (mm) 35 x 35 x 48 112.5 x 40 x 40 112.5 X 40 40
Sensing Distance Sn. (mm) 15 2-13 15
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 4055/4155 AC 2 WIRE
Dimension : Dia. D35 DFS40 D40
Length (mm) 35 x 35 x 48 112.5 x 40 x 40 112.5 X 40 40
Sensing Distance Sn. (mm) 15 2-13 15
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

16
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE DV40 D50 G-2

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. DV40 (Veriable Sensing Head) D50 Gap 2
Length (mm) 118 x 40 x 40 120 x 50 x 50 36 x 9.6 x 10
Sensing Distance Sn. (mm) 15 20 2 mm
Enclosure A A A
Load Current (mA) 400 400 200
Supply Voltage (V DC) D1 to D8 D1 to D8 D1 to D6
Switching Frequency (Hz) 100 100 200
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, NO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. DV40 (Veriable Sensing Head) D50 Gap 2
Length (mm) 118 x 40 x 40 120 x 50 x 50 36 x 9.6 x 10
Sensing Distance Sn. (mm) 15 20 2 mm
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 100 100 200
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. DV40 (Veriable Sensing Head) D50 N.A.
Length (mm) 118 x 40 x 40 120 x 50 x 50 N.A.
Sensing Distance Sn. (mm) 15 20 N.A.
Enclosure A A N.A.
Load Current (mA) 400 400 N.A.
Supply Voltage (V DC) D6 D6 N.A.
Switching Frequency (Hz) 100 100 N.A.
Logic Available NO, NC NO, NC N.A.

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. DV40 (Veriable Sensing Head) D50 N.A.
Length (mm) 118 x 40 x 40 120 x 50 x 50 N.A.
Sensing Distance Sn. (mm) 15 20 N.A.
Enclosure A A N.A.
Load Current (mA) 400 400 N.A.
Supply Voltage (V AC/DC) A6 A6 N.A.
Switching Frequency (Hz) 15 15 N.A.
Logic Available NO, NC NO, NC N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. DV40 (Veriable Sensing Head) D50 N.A.
Length (mm) 118 x 40 x 40 120 x 50 x 50 N.A.
Sensing Distance Sn. (mm) 15 20 N.A.
Enclosure A A N.A.
Load Current (mA) 400 400 N.A.
Supply Voltage (V AC) A1 to A5 A1 to A5 N.A.
Switching Frequency (Hz) 15 15 N.A.
Logic Available NO, NC NO, NC N.A.

17
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE G-3.5 G-5 G-10

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. Gap 3.5 Gap 5 Gap 10
Length (mm) 15 x 19 75 x 50 x 72 75 X 50 x 72
Sensing Distance Sn. (mm) 3.5 mm 5 mm 10 mm
Enclosure A A A
Load Current (mA) 100 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D8
Switching Frequency (Hz) 100 200 200
Logic Available PO, NO PO, NO PO, NO

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. Gap 3.5 Gap 5 Gap 10
Length (mm) 15 x 19 75 x 50 x 72 75 X 50 x 72
Sensing Distance Sn. (mm) 3.5 mm 5 mm 10 mm
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 100 200 200
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. Gap 5 Gap 10
Length (mm) N.A. 75 x 50 x 72 75 x 50 x 72
Sensing Distance Sn. (mm) N.A. 5 mm 10 mm
Enclosure N.A. A A
Load Current (mA) N.A. 200 200
Supply Voltage (V AC) N.A. A1 to A5 A1 to A5
Switching Frequency (Hz) N.A. 15 15
Logic Available N.A. PO, NO PO, NO

18
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE G-15 H40*25*12 H50*25*10

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. Gap 15 H402512 H5025
Length (mm) 61 x 30 x 45 40 x 25 x 12 50 x 25 x 10
Sensing Distance Sn. (mm) 15 mm 4 5
Enclosure A A B
Load Current (mA) 200 200 200
Supply Voltage (V DC) D1 to D8 D1 to D6 D1 to D6
Switching Frequency (Hz) 500 300 300
Logic Available PO, NO PO, PC, NO, NC PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. Gap 15 H402512 H5025
Length (mm) 61 x 30 x 45 40 x 25 x 12 50 x 25 x 10
Sensing Distance Sn. (mm) 15 mm 4 5
Enclosure A A B
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 500 300 300
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. Gap 15 H402512 H5025
Length (mm) 61 x 30 x 45 40 x 25 x 12 50 x 25 x 10
Sensing Distance Sn. (mm) 15 mm 4 5
Enclosure A A B
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 300 300
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.?
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.?
Logic Available N.A. N.A. N.A.

19
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE H50*45*12 IN-10 H28*16*10

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. H5022 IN10-4 H2816
Length (mm) 50 x 45 x 22 120 x 102 x 86 28 x 16 x 10
Sensing Distance Sn. (mm) 5 5 1.5
Enclosure B A+B A
Load Current (mA) 200 200 1000
Supply Voltage (V DC) D1 to D6 D1 to D8 D1 to D6
Switching Frequency (Hz) 500 100 200
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. H5022 IN10-4 H2816
Length (mm) 50 x 45 x 22 120 x 102 x 86 28 x 16 x 10
Sensing Distance Sn. (mm) 5 5 1.5
Enclosure B A+B A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 500 100 200
Logic Available NO, NC NO, NC PO, PC, NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. H5022 IN10-4 H2816
Length (mm) 50 x 45 x 22 120 x 102 x 86 28 x 16 x 10
Sensing Distance Sn. (mm) 5 5 1.5
Enclosure B A+B A
Load Current (mA) 200 200 1000
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 100 200
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. H5022 IN10-4 N.A.
Length (mm) 50 X 45 X 22 120 x 102 x 86 N.A.
Sensing Distance Sn. (mm) 5 5 N.A.
Enclosure B A+B N.A.
Load Current (mA) 200 200 N.A.
Supply Voltage (V AC) A1 to A5 A1 to A5 N.A.
Switching Frequency (Hz) 15 15 N.A.
Logic Available NO, NC NO, NC N.A.

20
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE H44*21*16 H54*37*14 H72*16*10

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. H4421 H5437 H7216
Length (mm) 44 x 21 x 16 54 x 37 x 14 72 x 16 x 10
Sensing Distance Sn. (mm) 3 2.5 1.5
Enclosure A A A
Load Current (mA) 200 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 1000 1000 1000
Logic Available PO, PC, NO, NC PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. H4421 H5437 H7216
Length (mm) 44 x 21 x 16 54 x 37 x 14 72 x 16 x 10
Sensing Distance Sn. (mm) 3 2.5 1.5
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 1000 1000 1000
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. H4421 H5437 H7216
Length (mm) 44 x 21 x 16 54 x 37 x 14 72 x 16 x 10
Sensing Distance Sn. (mm) 3 2.5 1.5
Enclosure A A A
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 1000 1000 1000
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

21
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE H45*12*12 H55*35*15 H27*10*10

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. H4512 H5515 H2710
Length (mm) 45 x 12 x 12 55 x 35 x 15 27 x 10 x 10
Sensing Distance Sn. (mm) 2.5 10 2
Enclosure A A A
Load Current (mA) 200 200 100
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 1000 100 1000
Logic Available PO, PC, NO, NC PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. H4512 H5515 H2710
Length (mm) 45 x 12 x 12 55 x 35 x 15 27 x 10 x 10
Sensing Distance Sn. (mm) 2.5 10 2
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 100
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 1000 100 1000
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. H4512 H5515 N.A.
Length (mm) 45 x 12 x 12 55 x 35 x 15 N.A.
Sensing Distance Sn. (mm) 2.5 10 N.A.
Enclosure A A N.A.
Load Current (mA) 200 200 N.A.
Supply Voltage (V DC) D6 D6 N.A.
Switching Frequency (Hz) 1000 100 N.A.
Logic Available NO, NC NO, NC N.A.

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. H5515 N.A.
Length (mm) N.A. 55 x 35 x 15 N.A.
Sensing Distance Sn. (mm) N.A. 10 N.A.
Enclosure N.A. A N.A.
Load Current (mA) N.A. 200 N.A.
Supply Voltage (V AC) N.A. A1 to A5 N.A.
Switching Frequency (Hz) N.A. 15 N.A.
Logic Available N.A. NO, NC N.A.

22
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE H79*30 H38*55 H30*45

1
2
3
4
5
6

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. N.A. H3855 H3045
Length (mm) N.A. 38 x 55 x 16 30 x 45 x 22
Sensing Distance Sn. (mm) N.A. 5 5
Enclosure N.A. A A
Load Current (mA) N.A. 200 200
Supply Voltage (V DC) N.A. D1 to D6 D1 to D6
Switching Frequency (Hz) N.A. 500 500
Logic Available N.A. PO, PC, NO, NC PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. N.A. H3855 H3045
Length (mm) N.A. 38 x 55 x 16 30 x 45 x 22
Sensing Distance Sn. (mm) N.A. 5 5
Enclosure N.A. A A
Load Current (mA) N.A. 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) N.A. D4 D4
Switching Frequency (Hz) N.A. 500 500
Logic Available N.A. NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. H7930 H3855 H3045
Length (mm) 79 x 30 x 24 38 x 55 x 16 30 x 45 x 22
Sensing Distance Sn. (mm) 2 5 5
Enclosure A A A
Load Current (mA) 400 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 200 500 500
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

23
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE H20*63 H100*80*45 R-6

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. N.A. H10080 R6
Length (mm) N.A. 100 x 80 x 45 61 x 37 x 30
Sensing Distance Sn. (mm) N.A. 50 6
Enclosure N.A. A A
Load Current (mA) N.A. 300 200
Supply Voltage (V DC) N.A. D1 to D6 D1 to D6
Switching Frequency (Hz) N.A. 200 100
Logic Available N.A. PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. N.A. H10080 R6
Length (mm) N.A. 100 x 80 x 45 61 x 37 x 30
Sensing Distance Sn. (mm) N.A. 50 6
Enclosure N.A. A A
Load Current (mA) N.A. 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) N.A. D4 D4
Switching Frequency (Hz) N.A. 200 200
Logic Available N.A. NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. H2063 H10080 R6
Length (mm) 20 x 11 x 63 100 x 80 x 45 61 x 37 x 30
Sensing Distance Sn. (mm) 5 50 6
Enclosure A A A
Load Current (mA) 200 300 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 500 200 100
Logic Available PO, PC, NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. H2063 H10080 N.A.
Length (mm) 20 x 11 x 63 100 x 80 x 45 N.A.
Sensing Distance Sn. (mm) 5 50 N.A.
Enclosure A A N.A.
Load Current (mA) 200 300 N.A.
Supply Voltage (V AC/DC) A6 A6 N.A.
Switching Frequency (Hz) 15 15 N.A.
Logic Available PO, PC, NO, NC NO, NC N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. N.A. H10080 R6
Length (mm) N.A. 100 x 80 x 45 N.A.
Sensing Distance Sn. (mm) N.A. 50 N.A.
Enclosure N.A. A N.A.
Load Current (mA) N.A. 300 N.A.
Supply Voltage (V AC) N.A. A1 to A5 N.A.
Switching Frequency (Hz) N.A. 15 N.A.
Logic Available N.A. NO, NC N.A.

24
INDUCTIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

INDUCTIVE R-10 R-22 R-30

SW 4051/4151 DC 3/4 WIRE


Dimension : Dia. R 10 R 22 R 30
Length (mm) 61 x 37 x 30 71 x 41 x 16 73 x 52 x 17
Sensing Distance Sn. (mm) 10 20 30
Enclosure A A A
Load Current (mA) 200 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 100 100 100
Logic Available PO, PC, NO, NC PO, PC, NO, NC PO, PC, NO, NC

SW 4052/4152 DC 2 WIRE NAMUR


Dimension : Dia. R 10 R 22 R 30
Length (mm) 61 x 37 x 30 71 x 41 x 16 73 x 52 x 17
Sensing Distance Sn. (mm) 10 20 30
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 100 100 100
Logic Available NO, NC NO, NC NO, NC

SW 4053/4153 DC 2 WIRE
Dimension : Dia. R 10 R 22 R 30
Length (mm) 61 x 37 x 30 71 x 41 x 16 73 x 52 x 17
Sensing Distance Sn. (mm) 10 20 30
Enclosure A A A
Load Current (mA) 200 200 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 100 100 100
Logic Available NO, NC NO, NC NO, NC

SW 4054/4154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 4055/4155 AC 2 WIRE
Dimension : Dia. R 10 N.A. N.A.
Length (mm) 61 x 37 x 30 N.A. N.A.
Sensing Distance Sn. (mm) 10 N.A. N.A.
Enclosure A N.A. N.A.
Load Current (mA) 200 N.A. N.A.
Supply Voltage (V AC) A1 to A5 N.A. N.A.
Switching Frequency (Hz) 15 N.A. N.A.
Logic Available PO, PC, NO, NC N.A. N.A.

25
ANALOGUE PROXIMITY SWITCHES

INDUCTIVE M18 M30 M36

SW 4051/4151 DC 3 WIRE
Dimension : Dia. M18 M30 M36
Length (mm) 65 65 65
Sensing Distance Sn. (mm) F : 2-5 NF : 2-8 F : 2-10 NF : 3-15 F : 2-10 NF : 3-15
Enclosure A A B,S
Load Current (mA) 20mA 20mA 20mA
Supply Voltage (V DC) D10 D10 D10
Switching Frequency (Hz) 25 25 25
Logic Available LOI, LOV LOI, LOV LOI, LOV

INDUCTIVE M18 M30 M36

SW 4051/4151 DC 3 WIRE
Dimension : Dia. M50 C20 M80
Length (mm) 65 48 65
Sensing Distance Sn. (mm) F : 4-12 F : 5-16 F : 0-9 F : 4-12
Enclosure B,S A A
Load Current (mA) 20mA 20mA 20mA
Supply Voltage (V DC) D10 D10 D10
Switching Frequency (Hz) 25 25 25
Logic Available LOI, LOV LOI, LOV LOI, LOV

Graph for 'LOV'

10
8
VOLTAGE (V)

4
2

2 4 6 8
DIST. (mm)

26
Capacitive Proximity Switches
Series - SW 505

INTRODUCTION
The Series SW 505 Capacitive Proximity Switches are Sensing Distance for

Sensing Distance in mm
designed for sensing wide range of materials. These various materials
switches give a superior performance for detection of 25
20
various non-metallic objects where Inductive type 15
switches can not function. 10
The major applications of Capacitive Switches include 5
0
sensing of;

...
s

r
C

S
Liquid level

rd d
d

Ea

ate
as

/A

M
PV
l

ar
o

l(
Gl

Bo

W
W

Cu

/A
lPlastic granules & parts

Cu
Ca
lSand / Bulk Material Level
Fig.1
lFood / Grain / Confectionary
GENERAL SPECIFICATIONS
lPaper & rubber
Operating Temperature : 55°C Max.
lGlass bottles / Tins in packaging
Response Time : 2 to 5 milliseconds
WORKING PRINCIPLE
Hysteresis : 3% to 15 %
The switch works on the principle of resonant oscillator of actuating point
circuit. A pair of brass/copper disc form the electrodes
Protection Grade : IP-67
of a capacitor & the object acts as a dielectric media.
The change in capacitance value, due to presence of Quiescent Current : 1) DC - 8 mA Max.
object, is sensed by a precision integrated circuit. An 2) AC - 2 mA Max.
effective output signal is generated at a preset value of Indication : LED for object status
capacitance.
Output : 1) To drive a Relay
CONSTRUCTION 2) PLC Compatible
These are offered in tubular threaded housing from size
M12 to M80. The enclosures are made of Brass, SPECIAL MODELS
Stainless Steel or Engineering Plastics. Special shapes, Special High Temperature models of Capacitive
Teflon housings are provided against requirements. switches are available with Operating Temperature upto
Standard models are provided with an integrated 150°C max.
2 meter long cable. Connector type versions are These switches are provided with a teflon front cap and
available with built-in male connectors. with suitable teflon cable.
These switches are to be used with a specially designed
SENSING DISTANCE controller/amplifier unit.
The nominal sensing distance of any size of switch is The permitted operating length between sensor and the
specified with Water as standard object and tested at controller is maximum 5 meters.
25°C.Depending upon the material of the object to be NAMUR type switches are available with
detected, the distance will vary. The sensitivity of the CMRI-Certificate and approved Power Supply Unit with
sensor is adjustable with a trimpot provided usually on built-in Zener barrier circuit.
the rear side of the sensor. Typical Sensing distance
chart for a M30 size sensor, for different objects is PROTECTIONS
shown in Fig-1. All the Capacitive switches are provided with Reverse
polarity, Overload, short circuit and false pulse
EFFECT OF AMBIENT CONDITIONS ON protections.
SENSITIVITY Rugged construction along with IP-67 grade of
The sensing distance is affected by change in ambient protection renders these switches to be very useful for
temperature, humidity, size and material of the object. liquid level monitoring applications.

27
CAPACITIVE PROXIMITY SWITCHES

RECTANGULAR
REED TYPE/ SW 715
TYPE SW 705

CAPACITIVE M12 M18 Ø20

SW 5051/5151 DC 3/4 WIRE


Dimension : Dia. M12 M18 Ø20
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-5 F-2-5 NF-2-10 F-2-7 NF-2-10
Enclosure B, A, S B, A, S, T A
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 5052/5152 DC 2 WIRE NAMUR


Dimension : Dia. M12 M18 Ø20
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-3 F-2-5 NF-2-5 F-2-10 NF-2-7 NF-2-10
Enclosure B, A, S B, A, S, T A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 25 50 50
Logic Available NO, NC NO, NC NO, NC

SW 5053/5153 DC 2 WIRE
Dimension : Dia. M12 M18 Ø20
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-3 F-2-5 NF-2-5 F-2-10 NF-2-7 NF-2-10
Enclosure B, A, S B, A, S, T A
Load Current (mA) 200 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 25 50 50
Logic Available NO, NC NO, NC NO, NC

SW 5054/5154 AC/DC 2 WIRE


Dimension : Dia. M12 M18 Ø20
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-3 F-2-5 NF-2-5 F-2-10 NF-2-7 NF-2-10
Enclosure B, A, S B, A, S, T A
Load Current (mA) 200 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 5055/5155 AC 2 WIRE
Dimension : Dia. M12 M18 Ø20
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-3 F-2-5 NF-2-5 F-2-10 NF-2-7 NF-2-10
Enclosure B, A, S B, A, S, T A
Load Current (mA) 200 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

28
CAPACITIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

CAPACITIVE M24 M30 Ø34

SW 5051/5151 DC 3/4 WIRE


Dimension : Dia. M24 M30 Ø34
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-8 F-2-10 NF-2-10 F-3-15 NF-3-12 NF-3-16
Enclosure B, S B, A, S, T A
Load Current (mA) 400 400 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 50 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 5052/5152 DC 2 WIRE NAMUR


Dimension : Dia. M24 M30 Ø34
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-8 F-2-10 NF-2-10 F-3-15 NF-3-12 NF-3-16
Enclosure B, S B, A, S, T A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC

SW 5053/5153 DC 2 WIRE
Dimension : Dia. M24 M30 Ø34
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-8 F-2-10 NF-2-10 F-3-15 NF-3-12 NF-3-16
Enclosure B, S B, A, S, T A
Load Current (mA) 400 400 200
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC

SW 5054/5154 AC/DC 2 WIRE


Dimension : Dia. M24 M30 Ø34
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-8 F-2-10 NF-2-10 F-3-15 NF-3-12 NF-3-16
Enclosure B, S B, A, S, T A
Load Current (mA) 400 400 200
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 5055/5155 AC 2 WIRE
Dimension : Dia. M24 M30 Ø34
Length (mm) 80 80 80
Sensing Distance Sn. (mm) NF-2-8 F-2-10 NF-2-10 F-3-15 NF-3-12 NF-3-16
Enclosure B, S B, A, S, T A
Load Current (mA) 400 400 200
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

29
CAPACITIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

CAPACITIVE M36 M50 M60

SW 5051/5151 DC 3/4 WIRE


Dimension : Dia. M36 M50 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 3-13 F - 3-16 F - 3-16 NF - 3-20 F - 3-20 NF - 3 - 25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 50 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 5052/5152 DC 2 WIRE NAMUR


Dimension : Dia. M36 M50 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 3-13 F - 3-16 F - 3-16 NF - 3-20 F - 3-20 NF - 3-25
Enclosure B, S B, S B, S
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC

SW 5053/5153 DC 2 WIRE
Dimension : Dia. M36 M50 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 3-13 F - 3-16 F - 3-16 NF - 3-20 F - 3-20 NF - 3-25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC

SW 5054/5154 AC/DC 2 WIRE


Dimension : Dia. M36 M50 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 3-13 F - 3-16 F - 3-16 NF - 3 - 20 F - 3-20 NF - 3-25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 5055/5155 AC 2 WIRE
Dimension : Dia. M36 M50 M60
Length (mm) 80 80 80
Sensing Distance Sn. (mm) F - 3-13 F - 3-16 F - 3-16 NF - 3-20 F - 3-20 NF - 3-25
Enclosure B, S B, S B, S
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

30
CAPACITIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

CAPACITIVE D40 DV40 D50

SW 5051/5151 DC 3/4 WIRE


Dimension : Dia. D40 DV40 (Variable Sensing Head) D50
Length (mm) 112.5 x 40 x 40 118 x 40 x 40 120 x 50 x 50
Sensing Distance Sn. (mm) 3 - 15 3 - 15 3 - 20
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D1 to D8 D1 to D8 D1 to D8
Switching Frequency (Hz) 100 100 100
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 5052/5152 DC 2 WIRE NAMUR


Dimension : Dia. D40 DV40 (Variable Sensing Head) D50
Length (mm) 112.5 x 40 x 40 118 x 40 x 40 120 x 50 x 50
Sensing Distance Sn. (mm) 3 - 15 3 - 15 3 - 20
Enclosure A A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 100 100 100
Logic Available NO, NC NO, NC NO, NC

SW 5053/5153 DC 2 WIRE
Dimension : Dia. D40 DV40 (Variable Sensing Head) D50
Length (mm) 112.5 x 40 x 40 118 x 40 x 40 120 x 50 x 50
Sensing Distance Sn. (mm) 3 - 15 3 - 15 3 - 20
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 100 100 100
Logic Available NO, NC NO, NC NO, NC

SW 5054/5154 AC/DC 2 WIRE


Dimension : Dia. D40 DV40 (Variable Sensing Head) D50
Length (mm) 112.5 x 40 x 40 118 x 40 x 40 120 x 50 x 50
Sensing Distance Sn. (mm) 3 - 15 3 - 15 3 - 20
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V AC/DC) A6 A6 A6
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

SW 5055/5155 AC 2 WIRE
Dimension : Dia. D40 DV40 (Variable Sensing Head) D50
Length (mm) 112.5 x 40 x 40 118 x 40 x 40 120 x 50 x 50
Sensing Distance Sn. (mm) 3 - 15 3 - 15 3 - 20
Enclosure A A A
Load Current (mA) 400 400 400
Supply Voltage (V AC) A1 to A5 A1 to A5 A1 to A5
Switching Frequency (Hz) 15 15 15
Logic Available NO, NC NO, NC NO, NC

31
CAPACITIVE PROXIMITY SWITCHES

RECTANGULAR TYPE

CAPACITIVE H50*25*10 H55*35*15 H120*80

SW 5051/5151 DC 3/4 WIRE


Dimension : Dia. H5025 H5515 H120*80
Length (mm) 50 x 25 x 10 55 x 35 x 15 120 x 80 x 30
Sensing Distance Sn. (mm) 5 10 50
Enclosure B A A
Load Current (mA) 200 200 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 300 100 500
Logic Available PO, PC, NO, NC PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 5052/5152 DC 2 WIRE NAMUR


Dimension : Dia. H5025 H5515 H120*80
Length (mm) 50 x 25 x 10 55 x 35 x 15 120 x 80 x 30
Sensing Distance Sn. (mm) 5 10 50
Enclosure B A A
Load Current (mA) 3 to 5 mA 3 to 5 mA 3 to 5 mA
Supply Voltage (V DC) D4 D4 D4
Switching Frequency (Hz) 300 100 500
Logic Available NO, NC NO, NC NO, NC

SW 5053/5153 DC 2 WIRE
Dimension : Dia. H5025 H5515 H120*80
Length (mm) 50 x 25 x 10 55 x 35 x 15 120 x 80 x 30
Sensing Distance Sn. (mm) 5 10 50
Enclosure B A A
Load Current (mA) 200 200 400
Supply Voltage (V DC) D6 D6 D6
Switching Frequency (Hz) 300 100 500
Logic Available NO, NC NO, NC NO, NC

SW 5054/5154 AC/DC 2 WIRE


Dimension : Dia. N.A. N.A. N.A.
Length (mm) N.A. N.A. N.A.
Sensing Distance Sn. (mm) N.A. N.A. N.A.
Enclosure N.A. N.A. N.A.
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V AC/DC) N.A. N.A. N.A.
Switching Frequency (Hz) N.A. N.A. N.A.
Logic Available N.A. N.A. N.A.

SW 5055/5155 AC 2 WIRE
Dimension : Dia. N.A. H5515 H120*80
Length (mm) N.A. 55 x 35 x 15 120 x 80 x 30
Sensing Distance Sn. (mm) N.A. 10 50
Enclosure N.A. A A
Load Current (mA) N.A. 200 400
Supply Voltage (V AC) N.A. A1 to A5 A1 to A5
Switching Frequency (Hz) N.A. 15 15
Logic Available N.A. NO, NC NO, NC

32
OPTICAL PROXIMITY SWITCHES
Series - SW 605

INTRODUCTION Thru-Beam (TB) type switches have separate transmitter &


The Optical Proximity Switches are a reliable solution for receiver. The object is sensed when the beam is interrupted.
automation where other Proximity Switches have Diffuse Scan (DS) type switches have both transmitter &
limitations. receiver in the same enclosure.
These are Infra-red type sensors incorporating advance The closely focussed beam is reflected back by the object.
and reliable technology. Retro-Reflective (RR) type switches use a special reflector
These switches have a distinct advantage of higher to reflect back the beam. When an object interrupts the
sensing distance over Inductive and Capacitive type of beam, an output signal is generated. These models have
switches. greater sensing distance compared to DS type. The
These can work more reliably in a noisy electro-magnetic receiver does not consider any reflections from other
radiation environment. As an infra-red wavelength light objects or sources.
source is used, it is immune to visible light interference.
EXPLANATION OF TECHNICAL TERMS
APPLICATIONS
STANDARD OBJECT
These switches are very useful for counting and position
The sensing distance specified for DS switch is considered
sensing applications in Pharma, Food, Paper, Plastic &
with a white object having minimum 90% reflectivity.
Automobile industry. They also work effectively in level
sensing applications for solids, grains, sand, ice and other SENSING DISTANCE
non-metallic bulk material. Some typical applications are - This is the maximum specified range of a sensor measured
lComponent positioning sensing in Electronic at 25°C using a standard object.
Industry
CONSTRUCTION
lCounting of bottles, Jars, Containers etc.
These switches are offered in tubular metallic, acrylic &
lGlass sheet position sensing
plastic enclosures. Standard models are available with
lFor security & safety in Machine Tools, Presses etc. integrated 2-meter long cable. Switches with built-in (Male)
lColor sensing applications connectors (International M8/M12 size) for quick
connections are also available.
PRINCIPLE OF OPERATION
These switches incorporate an Infra-red transmitter & SWITCHES WITH OPTICAL FIBRE
receiver device housed in a single enclosure or separate Special model of Optical Switches are available with an
enclosures. The precision pulsed transmitter beam is integrated Optical Fibre cable for flexible mounting and for
interrupted or reflected by the object. The advanced sensing miniature objects / high temperature objects.
electronic circuit generates an effective output signal This switch is of through-beam type and is available in
when the object is sensed. H type enclosures.

Object

Through Beam (TB) Receiver

Diffuse Scan (DS) Object

Retro-Reflective (RR) Reflector

Object

33
OPTICAL PROXIMITY SWITCHES

RECTANGULAR
SW 6051 / 6151TYPE

OPTICAL M12 M18 M30

AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 50 F - 200 F - 1 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 6051 / SW 6055 TB

OPTICAL M12 M18 M30

Transmitter Receiver Transmitter Receiver Transmitter Receiver

AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 2 Mtr. F - 5 Mtr. F - 10 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 6051 / SW 6055 RR

OPTICAL M12 M18 M30

AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 500 F - 1 Mtr. F - 5 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

34
OPTICAL PROXIMITY SWITCHES

RECTANGULAR
SW TYPEDS
6151 / SW 6155

OPTICAL M12 M18 M30

AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 50 F - 200 F - 1 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 6151 / SW 6155 TB

OPTICAL M12 M18 M30

Transmitter Receiver Transmitter Receiver Transmitter Receiver

AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 2 Mtr. F - 5 Mtr. F - 10 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

SW 6151 / SW 6155 RR

OPTICAL M12 M18 M30

AC / DC 2/3/4 Wire
Dimension : Dia. M12 M18 M30
Length (mm) 65, 80 65, 80 65, 80
Sensing Distance Sn. (mm) F - 500 F - 1 Mtr. F - 5 Mtr.
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) 200 400 400
Supply Voltage (V DC) D1 to D6 A1 to A5 D1 to D6 A1 to A5 D1 to D6 A1 to A5
Switching Frequency (Hz) 25 50 50
Logic Available PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO PO, PC, NO, NC, PDO, NDO

35
OPTICAL PROXIMITY SWITCHES

RECTANGULAR TYPE

OPTICAL H28*16 H31*17 H40*25

DC 3 Wire
Enclosure Type H28*16 H31*17 H40*25
Dimension : Length (mm) 28 x 16 x 10 31 x 17 x 12 40 x 25 x 12
Sensing Distance (DS) 20 20 120
(RR) N.A. N.A. 300
(TB) N.A. N.A. 300
Enclosure A A A
Load Current (mA) 100 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 50 50 15
Logic Available PO, NO PO, NO PO, NO

OPTICAL H28*16 H31*17 H40*25

DC 3 Wire
Enclosure Type H60*40 H50*55 H35*35
Dimension : Length (mm) 60 x 40 x 20 50 x 55 x 22 44 x 35 x 18
Sensing Distance (DS) 300 500 100
(RR) N.A. 2 Mtr. N.A.
(TB) N.A. 10 Mtr. N.A.
Enclosure A A A
Load Current (mA) 200 200 100
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 15 50 50
Logic Available PO, NO PO, NO PO, NO

OPTICAL H28*16 H31*17 H40*25

DC 3 Wire
Enclosure Type H50*25 R22 G100
Dimension : Length (mm) 50 x 25 x 15 40 x 40 x 38 128 x 81 x 30
Sensing Distance (DS) 50 N.A. N.A.
(RR) 200 For Water Drop 120
(TB) 1 Mtr. N.A. N.A.
Enclosure A A A
Load Current (mA) 100 200 200
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 10 10 15
Logic Available PO, NO PO, NO PO, NO

36
MAGNETIC PROXIMITY SWITCHES /
SPEED SENSORS
Series SW 705 / SW 715 / MSP 706/MSP /716 MSP 707/MSP 717

The series SW 705 Magnetic Proximity Switches MAGNETIC PICK-UP SENSORS


are available in two broad categories. (Series MSP 706/MSP 716)

Position sensing switches with Reed


l HALL EFFECT SENSORS
(Series MSP 707/MSP 717)
Element.
These sensors can be used only for sensing
2-Wire / 3-Wire Magnetic pick-up
l motion of a ferrous object e.g. Gear Wheel. These
Sensors. incorporate a special high strength ALNICO
Magnet with a properly designed coil. Special high
These switches are available in different shapes frequency sensors incorporate a Hall effect sensor.
and sizes. Tubular models are available in
Brass/SS enclosures in sizes M12, M18 and M30 These switches are available in 2/3-wire design.
and above. The 3-wire type switches have output logics /
operating voltages similar to other types of
SWITCHES WITH REED ELEMENT switches described earlier.

These switches are used only for position sensing The 2-wire switches should be necessarily used
application. These incorporate a hermetically with a special controller / amplifier unit.
sealed sensitive reed element. The object should
necessarily be a magnet. These are provided with APPLICATIONS
2-core built-in cable. The output is a potential free
Turbine high-speed sensor.
l
contact and can switch external load directly.
Bucket Elevator high temperature sensor.
l
The switching voltage and contact rating depends
upon switch size. Special models of latching type
switches are available for direction sensing AUTOMOBILE SENSORS
applications. Special / custom built models are available for
Automobile applications as below;
GENERAL SPECIFICATIONS
Transfer case speed sensor.
l
Sensing Range: 10 to 50 mm depending upon
Strength of object magnet. Wheel Rotation sensor for Fare-meter.
l

Termination : Integrated 2/3-core cable Door close sensor.


l

Load : 500 mA Max. Timing Sensor.


l

Object : Magnet Clutch worn-out sensor.


l

Operating Temp : 70°C / 200°C


Protection Grade : IP-67

APPLICATIONS
Position sensing in hydraulic cylinders,
Roto-meters,
Direction sensing applications
Level sensing of liquids

37
MAGNETIC PROXIMITY SWITCHES

RECTANGULAR
DC SW7051/ ACTYPE
SW7055

MAGNETIC M8 M12 M18

Dimension : Dia. M8 M12 M18


Length (mm) 50, 65 50, 65 50, 65
Sensing Distance Sn. (mm) F - 1.5 F - 1.5 F-3
Enclosure B, S B, A, S B, A, S, T
Load Current (mA) 200 200 400
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 25 25 50
Logic Available NO, NC NO, NC NO, NC

MAGNETIC

Dimension : Dia. H1211 H6520 H2814


Length (mm) 26 x 12 x 11 65 x 16 x 20 28 x 14 x 6
Sensing Distance Sn. (mm) 10 20 3
Enclosure H H A
Load Current (mA) 50 200 50
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC

MAGNETIC

Dimension : Dia. H2526 H5*26 H5*30


Length (mm) 25 x 26 x 6 4 x 5 x 26 5 x 7 x 30
Sensing Distance Sn. (mm) 20 20 10
Enclosure A H A
Load Current (mA) 100 100 100
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC

MAGNETIC

Dimension : Dia. H5625 H7*30 H3822


Length (mm) 110 x 56 x 25 7 x 8 x 30 38 x 22 x 12
Sensing Distance Sn. (mm) 100 10 20
Enclosure A H A
Load Current (mA) 100 100 50
Supply Voltage (V AC/DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 50 50 50
Logic Available NO, NC NO, NC NO, NC

38
MAGNETIC PROXIMITY SWITCHES

RECTANGULAR
DC SW7061 TYPE

MAGNETIC M12 M18 M30

Dimension : Dia. M12 M18 M30


Length (mm) 50, 65 50, 65 50, 65
Sensing Distance Sn. (mm) F - 1.5 F-3 F - 10
Enclosure B, A, S B, A, S, T B, A, S, T
Load Current (mA) N.A. N.A. N.A.
Supply Voltage (V DC) N.A. N.A. N.A.
Switching Frequency (Hz) 5000 5000 5000
Logic Available N.A. N.A. N.A.

DC SW7071
MAGNETIC

Dimension : Dia. M8 M10 M12


Length (mm) 35, 50, 65 50, 65 50, 65
Sensing Distance Sn. (mm) F - 1.5 F - 1.5 F - 1.5
Enclosure B, S B, S B, A, S
Load Current (mA) 50 50 50
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 5000 5000 5000
Logic Available PO, NO PO, NO PO, NO

MAGNETIC

Dimension : Dia. M16 M18 C10.7


Length (mm) 35, 50, 65 50, 65 50
Sensing Distance Sn. (mm) F-3 NF - 5 F-3 F-3
Enclosure B, S B, A, S, T B
Load Current (mA) 50 50 50
Supply Voltage (V DC) D1 to D6 D1 to D6 D1 to D6
Switching Frequency (Hz) 5000 5000 5000
Logic Available PO, NO PO, NO PO, NO

39
ULTRASONIC PROXIMITY SWITCHES
SERIES SW 305 / SW 315

The series SW 305 Ultrasonic Proximity Switches are APPLICATIONS


ideally suitable for level monitoring applications. The lAnti-collision detection for cranes.
Ultrasonic Sensors are available in different enclosures
to detect various types of objects. lLevel controller for liquids and solids.

The sensing range covers from 0.2 m to 20 meters. The lDetection of moving objects.
output signal is either in the form of a switching signal or lOpening / Closing of doors by detecting motion.
a linear output current or voltage signal. These sensors
have the ability to perform in dry and dusty GENERAL SPECIFICATIONS
environments. The performance of these sensors is not
affected by the presence of impeding materials like Ash, Output Signal : Switching/ Linear output
Soot, and Sawdust etc. Protection Grade : IP-67
These sensors are immune to electrical noise level Termination : Integrated 2-meter long cable.
generally present in the typical industrial environment. Sensing Range : 0.4 to 20 meters depending on
model and application.
WORKING PRINCIPLE
FEATURES
These switches incorporate a precise and delicate piezo
Ceramic Ultrasonic transducer pair. The sensors are The Ultrasonic Sensors are provided with programming
available in open as well as sealed type transducers. facility. General features available in programmable
sensors are as below;
The transmitter sends a modulated Ultrasonic Signal,
which is reflected by the object. lOutputs: Push-button "teachable”

A microprocessor-based circuit precisely measures the lMeasurement Rate: 40 per second


time taken to travel the distance from object to sensor. lResponse Time: 50 ms (FAST), 50mm/sec (SLOW)
Effective output signal (either linearly varying or lResolution: 0.086 mm
switching type)
lRepeatability 0.1% target range @ constant temp.
is generated depending upon application.
lWorking Temp: -40°C to +70°C
lRS-232 / RS-485 Communication for calibration
using software.

ULTRASONIC M30 M60 Prog.

SW 3051 DC 3 Wire
Dimension : Dia. M30 M60
Length (mm) 100 100
Sensing Distance Sn. (mm) 0.2 to 2 Mtr. 0.2 to 10 Mtr.
Enclosure A A
Load Current (mA) 20 20
Supply Voltage (V DC) D1 to D6 D6
Switching Frequency (Hz) 10 20
Logic Available PO, NO, LO LO

40
41
SELECTION CHART
While selecting a switch please follow this nomenclature

SW 4 0 5 1 NO D1 B X 18 XX XX

Basic Type Special Feature


3 - Ultrasonic HT - High Temperature
4 - Inductive HP - High Pressure
5 - Capacitive WI - Weld Immune
6 - Optical AM - All Metal
7 - Magnetic

Termination Special Function


0 - Integrated Cable
DS - Diffuse Scan
1 - Built-in Connector
RR - Retro Reflective
TB - Through Beam
Basic Connection NF - Non Ferrous
TD - Built-in Time Delay
1 - 3 Wire/4 Wire DC
CM - Colour Mark Sensor
2 - 2 Wire DC NAMUR
Any Other Function
3 - 2 Wire DC
4 - 2 Wire 20-250 V AC
5 - 2 Wire AC
6 - 2 Wire AC/DC
8 - 4 Wire with Relay O/P
Dimensions
Basic Connection Tubular - Diameter
AC : NO - Normally Open Rectangular - L x W
NC - Normally Closed
RO - Relay Output
DC : PO - PNP-NO
PC - PNP NC Mounting
NO - NPN NO
F - Flush
NC - NPN NC
N - Non Flush
PDO : PNP-NO+NC Dual Output
NDO : NPN-NO+NC Dual Output
LOV : Linear Output Voltage
LOI : Linear Output Current Enclosure
A - Tubular Threaded ABS-Plastic
Supply Voltage B - Tubular Threaded Brass Tube
C - Plain tube (Nickel Plated Brass)
D1 : 10-30 V DC A1 : 24 V AC
D - Plastic Block (ABS)
D2 : 5 V DC A2 : 110 V AC
(DF-Front Sensing DT-Top Sensing
D3 : 5-30 V DC A3 : 240 V AC
DR-Right Sensing DL-Left Sensing
D4 : 8 5 V DC
l
A4 : 90-250 V AC
DV-Variable Sensing Head)
D5 : 10-65 V DC A5 : 20-250 V AC
G - Slot / Gap Type, Plastic
D6 : 24 V DC A6 : 20-250 V AC/DC
H - Rectangular Block (Metal or Plastic)
D7 : 110 V DC
IN - Insert Type Plastic
D8 : 220 V DC
R - Ring Type Plastic
D9 : 48 V DC
S - Stainless Steel
D10 : 15-30 V DC

The Sensing Distance, Load Current, Switch Length, Cable Length, Operating Temperature will be as per
factory standard unless otherwise specifically mentioned.
Example : Inductive Proximity Switch of 3-Wire DC PNP tubular type with 24 mm diameter will have
following type no. SW 4051 PO D1 B24