Products / 120V

LOW FREQUENCY SOLAR INVERTER MODEL PV36-8048 TLV PV36-10048 TLV PV36-12048 TLV

PV3600 TLV Series Nominal Battery System Voltage


INVERTER OUTPUT
48VDC 48VDC 48VDC

Rated power 8.0KW 10.0KW 12.0KW


8~12KW | 245V | 100A, 200A Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
PV3600 TLV series is a multi-function inverter ,combining functions of inverter
Waveform Pure sine wave / same as input (bypass mode)
and MPPT solar charger controller, solar charger and battery charger to offer
uninterruptible power support. The comprehensive LCD display offers user- Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
configurable and easy-accessible button operation such as battery charging Output frequency 50Hz / 60Hz ± 0.3Hz
current, AC/solar charger priority, and selectable input voltage based on Inverter effciency(peak) >88%
different applications.
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
AC INPUT
■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.) Voltage 220V/230V/240V

■ Built-in MPPT solar charge controller 100A/200A Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
■ MPPT efficiency max 98%
BATTERY
■ Powerful charge rate up to 140Amp
Low battery voltage cutoff 40-48VDC for 48VDC mode
■ Inside BMS function
Low battery voltage recover 42-50VDC for 48VDC mode
■ DC start &Automatic Self-Diagnostic Function High battery voltage cutoff 60VDC for 48VDC mode
■ WIFI / USB monitoring function (wi-fi optional) High battery voltage recover 57VDC for 48VDC mode
■ Supporting AGS, BTS port Idle consumption-search mode <80W when power saver on

■ Compatible to generator AC CHARGER


Output voltage Depends on battery type
Charger AC input breaker rating 80A 80A 80A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Back panel description Maximum charge current 60A 70A 80A
BTS

1 2 3 4 Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
1. BAT- Input voltage waveform Sine wave (grid or generator)
9. BTS port
2. BAT+ Nominal input frequency 50Hz or 60Hz
10. Wifi communication port
3. AC input breaker Overload protection (SMPS Load) Circuit breaker
11. AC input
4. AC output breaker
12. AC outputr Output short circuit protection Circuit breaker
5. Remote control port
13. PV2 input Bypass breaker rating 63A 63A 63A
6. Fan
14. PV1 input Max bypass current 80A
7. USB port
15. Ground SOLAR CHARGER
8. AGS port
Maximum PV charge current 100A/200A
5 6 7 8 9 10 11 12 13 14 15 DC voltage 48V
Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~235VDC
Solar system connection Maximum PV array open circuit voltage 245VDC
Maximum effciency >98%
Standby power consumption <2W
PV1 input MECHANICAL SPECIFICATIONS
Mounting Wall mount
PV2 input TV Fridge Lighting Fans
Solar Panel
Dimensions (W*H*D) 640.5*402.3*212.7mm
Package Dimensions (W*H*D) 818*577.5*415mm
AC Input
OTHER
Operation temperature range 0°C to 50°C
Utility
Storage temperature -15°C to 60°C
BAT input Audible noise 60dB MAX

Generator Display LED+LCD


Inverter CERTIFICATION & STANDARDS
Battery CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011)