0% found this document useful (0 votes)
569 views1 page

3K6 - Service Memo

The document provides suggestions for checking faults in a 3K6 DIGIT amplifier. It lists components on different PCBs that could cause problems if damaged, and recommends replacing them. Common faults include the amplifier not working, fuses burning, and components getting damaged. Replacing suspected faulty components is usually suggested to resolve issues.

Uploaded by

vs055707
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
569 views1 page

3K6 - Service Memo

The document provides suggestions for checking faults in a 3K6 DIGIT amplifier. It lists components on different PCBs that could cause problems if damaged, and recommends replacing them. Common faults include the amplifier not working, fuses burning, and components getting damaged. Replacing suspected faulty components is usually suggested to resolve issues.

Uploaded by

vs055707
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Following are the suggestions while checking the fault DIGIT 3K6, comes from:

1- Components which appears problem on it while the 3K6 production, present by QC people in workshop.
2- Replacing suggestion presented by design engineer.

PCB: AVSQ01401-02A (P.S.U.)


Components Possible fault if it damaged Action
R36 1ohm / 0805 its damage will cut of PSU working as it is used as a fuse here Replace by a 0ohm resistor or just change to direct wiring
a> no Start, LED in mains power switch not light -up
D43,D44 FR104 Change to use MUR160
b> sometimes it will cause IC9 get damaged (not often)
D31,D32,D33,D34 MUR1540 / TO-220 amp not work, burn the Fuse in mains power socket Replace by new one
D1 20A / 1000V amp not work, burn the Fuse in mains power socket Replace by new one
Q1,Q2,Q3,Q4,Q5,Q6 RFP32N50K / TO-24 amp not work, burn the Fuse in mains power socket Replace by new one
D3 MUR1560 / TO-220 used for PFC filting, its damage will burn the Fuse in mains power socket Replace by new one
D13,D14 18V / 0.5W used as Fuse, its damage will stop the PSU working Replace by new one
Control Box PSU not work Replace by new one

PCB: AVSQ01401-02B
IC6, IC7 LM75L15 / LM79L15 both AMP channel not work and will cause D13/D14 burnt Replace by new one

PCB: AVSQ01401-01A / 01B (CH amp pcb)


D11 CH amp not working replace by new one
D2 18V / 0.5W CH amp not working replace by new one
R72 2R2 / 0805 CH amp not working replace by new one
L4,L5 33uH / 0805 CH amp not working replace by new one or just change to direct wiring
IC12 6N137/0198 CH amp not working replace by new one
IC5 LM78L05/SOF89 CH amp not working replace by new one
L2,L3 CH amp not working replace by new one or just change to direct wiring
F1,F2 CH amp not working replace by new one
C28 CH amp not working, even comonents/PCB burnt check soldering situation / replace by new one
Q21,Q24 main power transistor CH amp not working replace by new one
Control Box CH amp not working Replace by new one